RF Exposure

FCC ID: SMH-35051

RF Exposure Info

Download: PDF
FCCID_2906812

Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ151023008-00RX

FCC §15.247 (i) & §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions
of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in
excess of the communication guidelines.

                                Limits for General Population/Uncontrolled Exposure

                               Limits for General Population/Uncontrolled Exposure
             Frequency           Electric Field     Magnetic Field        Power           Averaging
               Range                Strength           Strength          Density            Time
               (MHz)                 (V/m)              (A/m)           (mW/cm2)          (Minutes)
               0.3-1.34               614                1.63           *(100)                 30
                                                                                  2
               1.34-30               824/f              2.19/f         *(180/f )               30
                30-300                27.5              0.073               0.2                30
               300-1500                   /               /             f/1500                 30
           1500-100,000                   /               /                 1.0                30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:

Predication of MPE limit at a given distance

                                                         PG
                                                   S=
                                                        4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


                                                  Turn-up          Evaluation           Power
   Frequency              Antenna Gain                                                               MPE Limit
                                               Conducted Power      Distance           Density
     (MHz)                                                                                           (mW/cm2)
                    (dBi)       (numeric)     (dBm)      (mW)        (cm)             (mW/cm2)
    2410.875          2            1.58       17.10      51.29         20              0.016             1.0

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
      from nearby persons.

Result: Compliance



FCC Part 15.247                                                                                     Page 8 of 36



Document Created: 2017-11-18 15:43:15