                   Installation Guide




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


R300S2 Transmitter Module Installation Manual




These instructions describe the process of installing the R300S2 transmitter module in the SENTINEL meter.
At the completion of this installation process, the SENTINEL meter will be able to transmit data via a wireless radio.


Compliance with FCC and Industry Canada Regulations

FCC Part 15, Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:

    •      Reorient or relocate the receiving antenna.
    •      Increase the separation between the equipment and receiver.
    •      Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    •      Consult the dealer or an experienced radio/TV technician for help

RF Exposure
In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be
installed such that a minimum separation distance of 20 cm.

Industry Canada ICES-003, Class B
This Class B digital apparatus complies with Industry Canada ICES-003.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.

Cet appareillage numérique de la classe B est conforme a la norme NMB-003 du Canada. L'opération est sujette aux deux
conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe
quelle interference reçue, y compris l'interférence quipeut causer l'opération peu désirée.

Changes or modifications to this device not expressly approved by Itron, Inc. could void the
user’s authority to operate the equipment.


R300S2 Instructions




    Installation Procedure

                                             To install the R300 option board in a SENTINEL meter, perform the
                                             following steps:

                                             1   Prior to taken meter out of service, download all pertinent data from
                                                 the meter.
                                             2   Remove power from meter.
                                             3   To install the R300S2, remove the meter outer cover and inner cover
                                                 exposing the circuit board As shown in Figure 1.


     Figure 1: Removal of Outer and Inner
                   Covers



                                             4   Connect the R300S2 ribbon cable connecter to the meter as shown in
                                                 Figure 2. Press the connector into the built-in guide of the lower
                                                 housing and firmly slide it onto the register board connector until it
                                                 snaps in place.




    Figure 2: R300 Ribbon Cable Connection



                                             5   Place the R300S2 inside of the meter as shown in Figure
                                                 3. The R300S2 board will fit securely on the left and right posts.
                                                 Press back on the tab located in the center of the inner cover. Make
                                                 sure the R300S2 board is placed beneath the tab. Once this is done,
                                                 release the tab to hold the R300S2 board in place.
                                             6   Close the meter. Place the FCC label in a visible location on the
                                                 meter nameplate and install the meter cover.




        Figure 3: R300 Module in Meter



                                             The R300S2 is now installed.

                                             You will now need to re-program your meter with these additional
                                             features to enable them.




2                                                    R300S2


                  R300S2 Instructions

Notes:




         R300S2                         3


    Itron, Inc.                                           Itron, Inc.
    Corporate Headquarters              Oconee Electricity Metering
    2818 North Sullivan Road              313-B North Highway 11
    Spokane, WA 99216                      West Union, SC 29696
    U.S.A.                                                    U.S.A.
    Tel: (509) 924-9900                       Tel: (864) 638-8300
    Fax: (509) 891-3355                      Fax: (864) 638-4950
    www.itron.com




4                              R300S2



Document Created: 2009-01-08 11:46:23
Document Modified: 2009-01-08 11:46:23

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC