RF Exposure

FCC ID: SK9PMCR1

RF Exposure Info

Download: PDF
FCCID_1057722

                   Certification Exhibit


                       FCC ID: SK9PMCR1
                        IC: 864G-PMCR1

          FCC Rule Part: 15.247, 15.249
    IC Radio Standards Specification: RSS-210

             ACS Report Number(s): 08-0454


       Manufacturer: Itron Electricity Metering Inc.
           Model(s): Cell Relay Pole, GSM




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model(s): Cell Relay Pole, GSM                FCC ID: SK9PMCR1                             IC: 864G-PMCR1


General Information:
Applicant:               Itron Electricity Metering Inc.
ACS Project:             08-0454
FCC ID:                  SK9PMCR1
Device Category:         Mobile
Environment:             General Population/Uncontrolled Exposure
Exposure Conditions:     Greater than 20 centimeters
Simultaneous Tx:         Yes

Technical Information:
                                                                                           GPRS Modem
                                          2.4GHz Zigbee         2.4GHz Zigbee                Module
     Radio           900 MHz LAN
                                          (Register PCB)       (Cell Relay PCB)1        FCC ID: N7NMC8790
                                                                                         IC:2417C-MC8790
                                                                                          Mobile low profile
Antenna Type            phantom            omnidirectional        omnidirectional
                                                                                               vertical
                                                                                           GSM850: 3dBi
Antenna Gain              3dBi                  0dBi                   0dBi
                                                                                           GSM1900: 3dBi
Conducted                                                                               GSM850: 31.8dBm
                        18.99dBm             17.21dBm                0.19dBm
Power                                                                                   GSM1900: 28.7dBm
                                                                                         GSM850: 3.019W
Maximum EIRP             0.158W                0.053W               0.0015mW
                                                                                         GSM1900: 1.479W
                                                                                         GSM850: 1.840W
Maximum ERP              0.096W                0.032W               0.0006mW
                                                                                         GSM1900: 0.901W

Note 1: The Cell Relay 2.4GHz low power Zigbee contribution to the overall MPE calculation is negligible
and therefore will not be included in the power density calculations below.

MPE Calculation:
        Power Density
        The Power Density (mW/cm2) is calculated as follows:
              PG
        S=
             4πR 2
        Where:
        S = power density (in appropriate units, e.g. mW/cm2)
        P = power input to the antenna (in appropriate units, e.g., mW)
        G = power gain of the antenna in the direction of interest relative to an isotropic radiator
        R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

        Source Based Time Averaging of GPRS/EDGE Modem
        The GPRS Modem is a Class 12 modem with a 50% source-based time averaged duty cycle.
        The measured level was reduced by a factor 3dB to account for the duty cycle of the Modem. The
        duty cycle correction factor is determined using the formula: 10log (0.50) = 3dB.

        Corrected Level 850 = 31.8 – 3.0 = 28.8dBm
        Corrected Level 1900 = 28.7 – 3.0 = 25.7dBm




                5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model(s): Cell Relay Pole, GSM                 FCC ID: SK9PMCR1                             IC: 864G-PMCR1


                                   MPE Calculator for Mobile Equipment
                          Limits for General Population/Uncontrolled Exposure*
  Transmit       Radio          Power         Radio     Antenna Antenna
                                                                           Distance Power Density
 Frequency       Power      Density Limit     Power      Gain     Gain (mW
                                                                             (cm)    (mW/cm^2)
   (MHz)         (dBm)       (mW/Cm2)         (mW)       (dBi)       eq.)
   902.25         18.99          0.60          79.25        3       1.995      20      0.031
    2405          17.21          1.00          52.60        0       1.000      20      0.010
    824            28.8          0.55         758.58        3       1.995      20      0.301
    1850           25.7          1.00         371.54        3       1.995      20      0.147

Summation of Power Densities – Simultaneous Transmissions
This device contains multiple transmitters which can operate simultaneously and therefore the maximum
RF exposure is determined by the summation of power densities.

The maximum power density as calculated by a summation of power densities for each simultaneous
transmission combination as follows:

        GPRS Modem Operating in the 800MHz Cellular Band:
        900MHz LAN:        0.031 (mW/cm^2)
        2.4GHz Zigbee:     0.010 (mW/cm^2)
        GSM 850 (GPRS):    0.301 (mW/cm^2)
        TOTAL:             0.342 (mW/cm^2)

        GPRS Modem Operating in the 1900MHz PCS Band:
        900MHz LAN:        0.031 (mW/cm^2)
        2.4GHz Zigbee:     0.010 (mW/cm^2)
        GSM 1900 (GPRS):   0.147 (mW/cm^2)
        TOTAL:             0.188 (mW/cm^2)


Installation Guidelines:
The installation manual shall contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

“RF Exposure (Intentional Radiators Only)
In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element
shall be installed such that a minimum separation distance of 20cm is maintained from the general
population.”

Conclusion:
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




                 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598



Document Created: 2009-01-12 12:41:09
Document Modified: 2009-01-12 12:41:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC