RF Exposure

FCC ID: SK9PLC-1

RF Exposure Info

Download: PDF
FCCID_1153665

                   Certification Exhibit



                        FCC ID: SK9PLC-1
                          IC: 864G-PLC1

              FCC Rule Part: 15.247
    IC Radio Standards Specification: RSS-210

           ACS Report Number: 09-0246-15C

      Manufacturer: Itron Electricity Metering, Inc.
                  Model: C2SOD-P




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: C2SOD-P                             FCC ID: SK9PLC-1                                    IC: 864G-PLC1


General Information:
Applicant:               Itron Electricity Metering, Inc.
ACS Project:             09-0246
Device Category:         Mobile
Environment:             General Population/Uncontrolled Exposure

Technical Information:
Antenna Type: PCB (Quarter Wave Embedded Slot)
Antenna Gain: 4.4dBi
Maximum Transmitter Conducted Power: 17.37 dBm (55mW)
Maximum System EIRP: 21.77 dBm, 150 mW
Exposure Conditions: Greater than 20 centimeters

MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4R 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                               MPE Calculator for Mobile Equipment
                      Limits for General Population/Uncontrolled Exposure*
  Transmit     Radio         Power        Radio    Antenna Antenna                          Power
                                                                      Distance
 Frequency     Power Density Limit        Power      Gain      Gain                         Density
                                                                        (cm)
   (MHz)       (dBm)      (mW/Cm2)        (mW)       (dBi)   (mW eq.)                     (mW/cm^2)
     2405       17.37         1.00         54.58      4.4      2.754     20                  0.030

Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




  ACS Report: 09-0246-15C                    Advanced Compliance Solutions                           Page 2



Document Created: 2009-08-10 11:45:00
Document Modified: 2009-08-10 11:45:00