Test Report

FCC ID: SK9M2LG2

Test Report

Download: PDF
FCCID_2931667

                                               Certification Test Report

                                                            FCC ID: SK9M2LG2
                                                             IC: 864G-M2LG2

                                           FCC Rule Part: 15.247
                                 IC Radio Standards Specification: RSS-247

                                       ACS Report Number: 15-0513.W06.1B


                                    Manufacturer: Itron Electricity Metering, Inc.
                                              Model: M2 Gateway2

                                            Test Begin Date: December 1, 2015
                                             Test End Date: January 29, 2016

                                              Report Issue Date: March 7, 2016




                                  FOR THE SCOPE OF ACCREDITATION UNDER Certificate Number: AT-2021

 This report must not be used by the client to claim product certification, approval, or endorsement by ANAB, NIST, or any agency of
                                                       the Federal Government.




                                                Reviewed by:
                                                                   Kirby Munroe
                                                         Director, Wireless Certifications
                                                                     ACS, Inc.

This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report
                                                        are representative of the sample(s) submitted for evaluation.
                                                            This report contains 25 pages


                           5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                                          TABLE OF CONTENTS
1      GENERAL ............................................................................................................................................ 3
    1.1       PURPOSE.......................................................................................................................................... 3
    1.2       PRODUCT DESCRIPTION ................................................................................................................... 3
    1.3       TEST METHODOLOGY AND CONSIDERATIONS ................................................................................. 4
2      TEST FACILITIES .............................................................................................................................. 5
    2.1     LOCATION ....................................................................................................................................... 5
    2.2     LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS ................................................ 5
    2.3     RADIATED EMISSIONS TEST SITE DESCRIPTION .............................................................................. 6
       2.3.1    Semi-Anechoic Chamber Test Site .......................................................................................... 6
       2.3.2    Open Area Tests Site (OATS) ................................................................................................. 7
    2.4     CONDUCTED EMISSIONS TEST SITE DESCRIPTION ........................................................................... 8
3      APPLICABLE STANDARD REFERENCES.................................................................................... 8

4      LIST OF TEST EQUIPMENT ............................................................................................................ 9

5      SUPPORT EQUIPMENT ...................................................................................................................10

6      EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ..........................................................10

7      SUMMARY OF TESTS ......................................................................................................................11
    7.1     ANTENNA REQUIREMENT – FCC: SECTION 15.203 ........................................................................11
    7.2     POWER LINE CONDUCTED EMISSIONS – FCC 15.207, IC: RSS-GEN 8.8 ........................................11
       7.2.1    Measurement Procedure ........................................................................................................11
       7.2.2    Measurement Results .............................................................................................................11
    7.3     PEAK OUTPUT POWER - FCC 15.247(B)(2) IC: RSS-247 5.4(1) .....................................................15
       7.3.1    Measurement Procedure (Conducted Method)......................................................................15
       7.3.2    Measurement Results .............................................................................................................15
    7.4     CHANNEL USAGE REQUIREMENTS .................................................................................................16
       7.4.1    Carrier Frequency Separation – FCC 15.247(a)(1) IC: RSS-247 5.1(2) ..............................16
           7.4.1.1       Measurement Procedure ................................................................................................................... 16
           7.4.1.2       Measurement Results ....................................................................................................................... 16
       7.4.2          Number of Hopping Channels – FCC 15.247(a)(1)(i) IC: RSS-247 5.1(3) ...........................17
           7.4.2.1       Measurement Procedure ................................................................................................................... 17
           7.4.2.2       Measurement Results ....................................................................................................................... 17
       7.4.3          Channel Dwell Time – FCC 15.247(a)(1)(i) IC: RSS-247 5.1(3) ..........................................18
           7.4.3.1       Measurement Procedure ................................................................................................................... 18
           7.4.3.2       Measurement Results ....................................................................................................................... 18
       7.4.4          20dB / 99% Bandwidth - FCC 15.247(a)(1)(i) IC: RSS-247 5.1(3)......................................19
           7.4.4.1       Measurement Procedure ................................................................................................................... 19
           7.4.4.2       Measurement Results ....................................................................................................................... 19
    7.5     BAND-EDGE COMPLIANCE AND SPURIOUS EMISSIONS ...................................................................21
       7.5.1   Band-Edge Compliance of RF Conducted Emissions - FCC 15.247(d); IC RSS-247 5.5 .....21
           7.5.1.1       Measurement Procedure ................................................................................................................... 21
           7.5.1.2       Measurement Results ....................................................................................................................... 21
       7.5.2          RF Conducted Spurious Emissions - FCC 15.247(d); IC RSS-247 5.5 .................................22
           7.5.2.1       Measurement Procedure ................................................................................................................... 22
           7.5.2.2       Measurement Results ....................................................................................................................... 22
       7.5.3          Radiated Spurious Emissions - FCC 15.205, 15.209; RSS-Gen 8.9/8.10 ..............................23
           7.5.3.1       Measurement Procedure ................................................................................................................... 23
           7.5.3.2       Measurement Results ....................................................................................................................... 23
           7.5.3.3       Sample Calculation: ......................................................................................................................... 24
8      CONCLUSION ....................................................................................................................................25




                    5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


      Model: M2 Gateway2               FCC ID: SK9M2LG2                  IC: 864G-M2LG2

1     GENERAL

1.1    Purpose

The purpose of this report is to demonstrate compliance with Part 15 Subpart C of the FCC’s
Code of Federal Regulations and Industry Canada’s Radio Standards Specification RSS-247
Certification for limited modular approval.

1.2    Product description

The Itron M2 Gateway2 is an electricity metering module which includes a 902.4 MHz to 927.6
MHz transmitter as well as a Zigbee transmitter that operates in the 2405 MHz to 2475 MHz
band. The module operates on alternating current voltage which is supplied by a host device.

The M2 Gateway2 is designed to be integrated into 1S, 2S and 12S electric utility meter forms.
This report addresses the 900MHz radio only.

Technical Information:
          Detail                                  Description
Frequency Range                                902.4 – 927.6 MHz
Number of Channels                                     64
Modulation Format                                     FSK
Operating Voltage                                120Vac/60Hz
Antenna Type / Gain                  ¼ Wave Embedded Slot Antenna / 2.2dBi gain

Manufacturer Information:
Itron Electricity Metering, Inc.
313 North Highway 11
West Union, SC 29696

EUT Serial Numbers: ACS #4 (Radiated), ACS #3 (RF Conducted)

Test Sample Condition: The test samples were provided in good working order with no visible
defects.




ACS Report: 15-0513.W06.1B             Advanced Compliance Solutions                  Page 3


   Model: M2 Gateway2                  FCC ID: SK9M2LG2                   IC: 864G-M2LG2


1.3   Test Methodology and Considerations
All modes of operation, including all available data rates, were evaluated for each mode. The
data presented in this report represents the worst case where applicable.

For radiated emissions the EUT was evaluated in three Electric Utility Meters in an orientation
representative of final installation. The worst case electric utility meter was the FM12S.

For AC power line conducted emissions the EUT was evaluated with a typical host.

Radiated inter-modulation testing was performed for all combinations of simultaneous
transmission and found to be in compliance.




ACS Report: 15-0513.W06.1B              Advanced Compliance Solutions                  Page 4


      Model: M2 Gateway2                FCC ID: SK9M2LG2                   IC: 864G-M2LG2

2     TEST FACILITIES

2.1     Location

The radiated and conducted emissions test sites are located at the following address:

      Advanced Compliance Solutions
      5015 B.U. Bowman Drive
      Buford, GA 30518
      Phone: (770) 831-8048
      Fax: (770) 831-8598


2.2     Laboratory Accreditations/Recognitions/Certifications

ACS is accredited to ISO/IEC 17025 by the ANSI-ASQ National Accreditation Board/ANAB
accreditation program, and has been issued certificate number AT-2021 in recognition of this
accreditation. Unless otherwise specified, all tests methods described within this report are
covered under the ISO/IEC 17025 scope of accreditation.

The Semi-Anechoic Chamber Test Site, Open Area Test Site (OATS) and Conducted Emissions
Site have been fully described, submitted to, and accepted by the FCC, Industry Canada and the
Japanese Voluntary Control Council for Interference by information technology equipment.

FCC Registration Number: 391271
Industry Canada Lab Code: IC 4175A
VCCI Member Number: 1831
•       VCCI OATS Registration Number R-1526
•       VCCI Conducted Emissions Site Registration Number: C-1608




ACS Report: 15-0513.W06.1B               Advanced Compliance Solutions                  Page 5


      Model: M2 Gateway2                  FCC ID: SK9M2LG2                     IC: 864G-M2LG2


2.3     Radiated Emissions Test Site Description

2.3.1    Semi-Anechoic Chamber Test Site

The Semi-Anechoic Chamber Test Site consists of a 20’ x 30’ x 18’ shielded enclosure. The
chamber is lined with Toyo Ferrite Grid Absorber, model number FFG-1000. The ferrite tile grid is
101 x 101 x 19mm thick and weighs approximately 550 grams. These tiles are mounted on steel
panels and installed directly on the inner walls of the chamber.

The turntable is 150cm in diameter and is located 160cm from the back wall of the chamber. The
chamber is grounded via 1 – 8’ copper ground rod, installed at the center of the back wall, it is
bound to the ground plane using 3/4” stainless steel braided cable.

The turntable is all steel, flush mounted table installed in an all steel frame. The table is remotely
operated from inside the control room located 25’ from the range. The turntable is electrically
bonded to the surrounding ground plane via steel fingers installed on the edge of the turn table.
The steel fingers make constant contact with the ground plane during operation.

Behind the turntable is a 3’ x 6’ x 4’ deep shielded pit used for support equipment if necessary.
The pit is equipped with 1 – 4” PVC chases from the turntable to the pit that allow for cabling to
the EUT if necessary. The underside of the turntable can be accessed from the pit so cables can
be supplied to the EUT from the pit.

A diagram of the Semi-Anechoic Chamber Test Site is shown in Figure 2.3-1 below:




                                             3 Meters


                                                                         5 Feet
                                                                        Diameter




                                                                                    20 Feet


                                               30 Feet
                        Figure 2.3-1: Semi-Anechoic Chamber Test Site




ACS Report: 15-0513.W06.1B                 Advanced Compliance Solutions                      Page 6


    Model: M2 Gateway2                   FCC ID: SK9M2LG2                     IC: 864G-M2LG2


2.3.2   Open Area Tests Site (OATS)

The open area test site consists of a 40’ x 66’ concrete pad covered with a perforated electro-
plated galvanized sheet metal. The perforations in the sheet metal are 1/8” holes that are
staggered every 3/16”. The individual sheets are placed to overlap each other by 1/4” and are
riveted together to provide a continuous seam. Rivets are spaced every 3” in a 3 x 20 meter
perimeter around the antenna mast and EUT area. Rivets in the remaining area are spaced as
necessary to properly secure the ground plane and maintain the electrical continuity.

The entire ground plane extends 12’ beyond the turntable edge and 16’ beyond the antenna mast
when set to a 10 meter measurement distance. The ground plane is grounded via 4 – 8’ copper
ground rods, each installed at a corner of the ground plane and bound to the ground plane using
3/4” stainless steel braided cable.

The turntable is an all aluminum 10’ flush mounted table installed in an all aluminum frame. The
table is remotely operated from inside the control room located 40’ from the range. The turntable
is electrically bonded to the surrounding ground plane via steel fingers installed on the edge of
the turn table. The steel fingers make constant contact with the ground plane during operation.

Adjacent to the turntable is a 7’ x 7’ square and 4’ deep concrete pit used for support equipment if
necessary. The pit is equipped with 5 – 4” PVC chases from the pit to the control room that allow
for cabling to the EUT if necessary. The underside of the turntable can be accessed from the pit
so cables can be supplied to the EUT from the pit. The pit is covered with 2 sheets of 1/4”
diamond style re-enforced steel sheets. The sheets are painted to match the perforated steel
ground plane; however the underside edges have been masked off to maintain the electrical
continuity of the ground plane. All reflecting objects are located outside of the ellipse defined in
ANSI C63.4.

A diagram of the Open Area Test Site is shown in Figure 2.3-2 below:



                                             10Meter

                                                        3 Meters



                                                                                  40Feet




                                                                      7x7x4
                                                                       Pit

                                           66 Feet

                               Figure 2.3-2: Open Area Test Site




ACS Report: 15-0513.W06.1B                Advanced Compliance Solutions                    Page 7


      Model: M2 Gateway2                    FCC ID: SK9M2LG2                     IC: 864G-M2LG2


2.4       Conducted Emissions Test Site Description

The AC mains conducted EMI site is located in the main EMC lab. It consists of an 8’ x 8’ solid
aluminum horizontal ground reference plane (GRP) bonded every 3” to an 8’ X 8’ vertical ground
plane.

The site is of sufficient size to test table top and floor standing equipment in accordance with
section 6.1.4 of ANSI C63.4.

A diagram of the room is shown below in figure 2.4-1:



                   Vertical Ground Plane (8’ x 8’)




                                                      Non-Conductive EUT Table
                                                          (1m x 1.5m x .8m)


              .4 Meters




                 .8 Meters


                                                            Horizontal Ground Plane (8’ x 8’)

               LISN
                             Figure 2.4-1: AC Mains Conducted EMI Site


3     APPLICABLE STANDARD REFERENCES

The following standards were used:

          ANSI C63.10-2013: American National Standard of Procedures for Compliance Testing of
           Unlicensed Wireless Devices
          US Code of Federal Regulations (CFR): Title 47, Part 2, Subpart J: Equipment Authorization
           Procedures, 2016
          US Code of Federal Regulations (CFR): Title 47, Part 15, Subpart C: Radio Frequency Devices,
           Intentional Radiators, 2016
          Industry Canada Radio Standards Specification: RSS-247 – Digital Transmission Systems (DTSs),
           Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices,
           Issue 1, May 2015.
          Industry Canada Radio Standards Specification:        RSS-GEN – General Requirements and
           Information for the Certification of Radiocommunication Equipment, Issue 4, Nov 2014.




ACS Report: 15-0513.W06.1B                   Advanced Compliance Solutions                      Page 8


      Model: M2 Gateway2                                FCC ID: SK9M2LG2                           IC: 864G-M2LG2

4      LIST OF TEST EQUIPMENT

The calibration interval of test equipment is annually or the manufacturer’s recommendations.
Where the calibration interval deviates from the annual cycle based on the instrument
manufacturer’s recommendations, it shall be stated below.

                                             Table 4-1: Test Equipment
                                                                                                                    Calibration
    AssetID       Manufacturer            Model #          Equipment Type        Serial #   Last Calibration Date    Due Date
       1        Rohde & Schwarz        ESMI - Display     Spectrum Analyzers   833771/007        7/14/2015          7/14/2016
       2        Rohde & Schwarz        ESMI-Receiver      Spectrum Analyzers   839587/003        7/14/2015          7/14/2016
      30      Spectrum Technologies      DRH-0118             Antennas           970102          4/30/2015          4/30/2017
      40              EMCO                  3104              Antennas            3211           2/10/2015          2/10/2017
      73              Agilent              8447D              Amplifiers       2727A05624        7/15/2015          7/15/2016
      167              ACS          Chamber EMI Cable Set     Cable Set            167           10/20/2015         10/20/2016
      267             Agilent             N1911A                Meters         MY45100129        8/24/2015          8/24/2017
      268             Agilent             N1921A               Sensors         MY45240184        8/13/2015          8/13/2017
                                        SMR-290AW-
      292       Florida RF Cables        480.0-SMR              Cables            None            3/3/2015           3/3/2016
      324              ACS                 Belden               Cables            8214            5/5/2015           5/5/2016
      337       Microwave Circuits       H1G513G1               Filters          282706          5/20/2015          5/20/2016
      338        Hewlett Packard           8449B              Amplifiers       3008A01111        8/21/2015           8/21/2017
      340       Aeroflex/Weinschel         AS-20             Attenuators          7136           7/13/2015          7/13/2016
      412         Electro Metrics          LPA-25             Antennas            1241           7/24/2014          7/24/2016
      422           Florida RF      SMS-200AW-72.0-SMR          Cables             805           10/30/2015         10/30/2016
      616       Florida RF Cables          SMRE                 Cables             N/A            9/3/2015           9/3/2016
      622       Rohde & Schwarz            FSV40              Analyzers          101338          7/15/2015          7/15/2016
     3010       Rohde & Schwarz           ENV216                 LISN             3010           7/10/2015          7/10/2016
    RE112       Rohde & Schwarz           ESIB26               Receiver        836119/012        7/16/2015          7/16/2016




ACS Report: 15-0513.W06.1B                               Advanced Compliance Solutions                               Page 9


      Model: M2 Gateway2                    FCC ID: SK9M2LG2                IC: 864G-M2LG2

5     SUPPORT EQUIPMENT

                                Table 5-1: Support Equipment
    Item   Equipment Type     Manufacturer Model Number               Serial Number
                                                                        131 980 110
             Electric Meter     Landis + Gyr     FOCUS AXRe-SD          131 980 032
       1                                                                131 980 122
             Electric Meter                           Type 3R
                                  Milbank                                     N/A
       2        Socket                                Enclosure


6     EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM




                                                 EUT

                                                  1


                                                  2




                                                      A




                                               AC Mains




    A: AC Power Cable, 200 cm, Non-Shielded


                              Figure 6-1: Test Setup Block Diagram




ACS Report: 15-0513.W06.1B                  Advanced Compliance Solutions             Page 10


      Model: M2 Gateway2                 FCC ID: SK9M2LG2                IC: 864G-M2LG2

7     SUMMARY OF TESTS

Along with the tabular data shown below, plots were taken of all signals deemed important
enough to document.

7.1     Antenna Requirement – FCC: Section 15.203

The EUT utilizes a ¼ Wave Embedded Slot Antenna with a gain of 2.2dBi therefore satisfying the
requirements of Section 15.203.

7.2     Power Line Conducted Emissions – FCC 15.207, IC: RSS-Gen 8.8

7.2.1    Measurement Procedure

ANSI C63.4 sections 6 and 7 were the guiding documents for this evaluation. Conducted
emissions were performed from 150kHz to 30MHz with the spectrum analyzer’s resolution
bandwidth set to 9kHz and the video bandwidth set to 30kHz. The calculation for the conducted
emissions is as follows:

Corrected Reading = Analyzer Reading + LISN Loss + Cable Loss
Margin = Applicable Limit - Corrected Reading

7.2.2    Measurement Results

            Table 7.2.2-1: Conducted EMI Results – 1S Meter Host (120 VAC) – Line 1

                   Corrected Reading
Frequency                                   Limit       Margin                      Correction
                                                                         Line
  (MHz)                                    (dBuV)        (dB)                          (dB)
               Quasi-Peak      Average
                (dBuV)          (dBuV)
0.618036           ---          25.57      46.00         20.43            L1            9.7
0.618036         33.18            ---      56.00         22.82            L1            9.7
4.567635           ---          11.04      46.00         34.96            L1            9.8
4.567635         28.88            ---      56.00         27.12            L1            9.8
4.661022           ---           7.19      46.00         38.81            L1            9.8
4.661022         27.28            ---      56.00         28.72            L1            9.8
4.808317           ---          11.27      46.00         34.73            L1            9.8
4.808317         29.02            ---      56.00         26.98            L1            9.8
5.818136           ---          12.99      50.00         37.01            L1            9.9
5.818136         31.76            ---      60.00         28.24            L1            9.9
5.915130           ---          11.57      50.00         38.43            L1            9.9
5.915130         29.05            ---      60.00         30.95            L1            9.9




ACS Report: 15-0513.W06.1B               Advanced Compliance Solutions                Page 11


   Model: M2 Gateway2                    FCC ID: SK9M2LG2                IC: 864G-M2LG2

            Table 7.2.2-2: Conducted EMI Results – 1S Meter Host (120 VAC) – Line 2

                   Corrected Reading
Frequency                                   Limit      Margin                     Correction
                                                                       Line
  (MHz)                                    (dBuV)       (dB)                         (dB)
               Quasi-Peak      Average
                (dBuV)          (dBuV)
0.616333           ---          40.03      46.00        5.97             N             9.7
0.616333         45.70            ---      56.00        10.30            N             9.7
1.237575           ---          31.29      46.00        14.71            N             9.7
1.237575         43.34            ---      56.00        12.66            N             9.7
4.151804           ---          20.19      46.00        25.81            N             9.8
4.151804         39.96            ---      56.00        16.04            N             9.8
4.394890           ---          24.70      46.00        21.30            N             9.8
4.394890         41.28            ---      56.00        14.72            N             9.8
4.404910           ---          23.40      46.00        22.60            N             9.8
4.404910         40.72            ---      56.00        15.28            N             9.8
4.533166           ---          21.21      46.00        24.79            N             9.8
4.533166         40.20            ---      56.00        15.80            N             9.8


            Table 7.2.2-3: Conducted EMI Results – 2S Meter Host (240 VAC) – Line 1

                   Corrected Reading
Frequency                                   Limit      Margin                     Correction
                                                                       Line
  (MHz)                                    (dBuV)       (dB)                         (dB)
               Quasi-Peak      Average
                (dBuV)          (dBuV)
0.207815           ---          35.20      53.10        17.90            L1            9.6
0.207815         41.40            ---      63.13        21.73            L1            9.6
0.633066           ---          26.82      46.00        19.18            L1            9.7
0.633066         36.43            ---      56.00        19.57            L1            9.7
0.939479           ---          18.49      46.00        27.51            L1            9.7
0.939479         32.69            ---      56.00        23.31            L1            9.7
4.440381           ---          16.07      46.00        29.93            L1            9.8
4.440381         32.17            ---      56.00        23.83            L1            9.8
4.521142           ---          11.23      46.00        34.77            L1            9.8
4.521142         31.09            ---      56.00        24.91            L1            9.8
5.817334           ---          13.66      50.00        36.34            L1            9.9
5.817334         32.51            ---      60.00        27.49            L1            9.9




ACS Report: 15-0513.W06.1B               Advanced Compliance Solutions                Page 12


   Model: M2 Gateway2                    FCC ID: SK9M2LG2                IC: 864G-M2LG2

            Table 7.2.2-4: Conducted EMI Results – 2S Meter Host (240 VAC) – Line 2

                   Corrected Reading
Frequency                                   Limit      Margin                     Correction
                                                                       Line
  (MHz)                                    (dBuV)       (dB)                         (dB)
               Quasi-Peak      Average
                (dBuV)          (dBuV)
0.525551           ---          39.67      46.00        6.33             N             9.7
0.525551         46.46            ---      56.00        9.54             N             9.7
0.616734           ---          40.31      46.00        5.69             N             9.7
0.616734         48.70            ---      56.00        7.30             N             9.7
1.143487           ---          35.83      46.00        10.17            N             9.7
1.143487         46.39            ---      56.00        9.61             N             9.7
1.975098           ---          30.97      46.00        15.03            N             9.7
1.975098         45.00            ---      56.00        11.00            N             9.7
4.277655           ---          25.29      46.00        20.71            N             9.8
4.277655         44.00            ---      56.00        12.00            N             9.8
4.428958           ---          28.11      46.00        17.89            N             9.8
4.428958         43.44            ---      56.00        12.56            N             9.8


           Table 7.2.2-5: Conducted EMI Results – 12S Meter Host (120 VAC) – Line 1

                   Corrected Reading
Frequency                                   Limit      Margin                     Correction
                                                                       Line
  (MHz)                                    (dBuV)       (dB)                         (dB)
               Quasi-Peak      Average
                (dBuV)          (dBuV)
0.494690           ---          34.25      46.08        11.83            L1            9.7
0.494690         39.44            ---      56.08        16.64            L1            9.7
0.605110           ---          27.31      46.00        18.69            L1            9.7
0.605110         37.16            ---      56.00        18.84            L1            9.7
4.505711           ---          15.47      46.00        30.53            L1            9.8
4.505711         34.96            ---      56.00        21.04            L1            9.8
4.817134           ---          16.78      46.00        29.22            L1            9.8
4.817134         33.62            ---      56.00        22.38            L1            9.8
5.042184           ---          12.34      50.00        37.66            L1            9.8
5.042184         32.47            ---      60.00        27.53            L1            9.8
5.723347           ---          17.30      50.00        32.70            L1            9.9
5.723347         36.55            ---      60.00        23.45            L1            9.9




ACS Report: 15-0513.W06.1B               Advanced Compliance Solutions                Page 13


   Model: M2 Gateway2                   FCC ID: SK9M2LG2                IC: 864G-M2LG2

           Table 7.2.2-6: Conducted EMI Results – 12S Meter Host (120 VAC) – Line 2

                  Corrected Reading
Frequency                                  Limit       Margin                    Correction
                                                                       Line
  (MHz)                                   (dBuV)        (dB)                        (dB)
              Quasi-Peak      Average
               (dBuV)          (dBuV)
0.498698          ---          43.77      46.02         2.25            N              9.7
0.498698         49.26           ---      56.02         6.76            N              9.7
0.615731          ---          30.64      46.00         15.36           N              9.7
0.615731         47.84           ---      56.00         8.16            N              9.7
3.212725          ---          22.84      46.00         23.16           N              9.8
3.212725         43.05           ---      56.00         12.95           N              9.8
4.280060          ---          24.32      46.00         21.68           N              9.8
4.280060         43.70           ---      56.00         12.30           N              9.8
4.548797          ---          26.51      46.00         19.49           N              9.8
4.548797         44.12           ---      56.00         11.88           N              9.8
4.591884          ---          23.91      46.00         22.09           N              9.8
4.591884         43.22           ---      56.00         12.78           N              9.8




ACS Report: 15-0513.W06.1B              Advanced Compliance Solutions                 Page 14


      Model: M2 Gateway2                FCC ID: SK9M2LG2                  IC: 864G-M2LG2


7.3     Peak Output Power - FCC 15.247(b)(2) IC: RSS-247 5.4(1)

7.3.1    Measurement Procedure (Conducted Method)

The RF output port of the EUT was directly connected to the input of a spectrum analyzer using
suitable attenuation. The device employs > 50 channels at any given time, therefore the power is
limited to 1 Watt.


7.3.2    Measurement Results

                   Table 7.3.2-1: Maximum Conducted Peak Output Power
                              Frequency              Level
                                 [MHz]              [dBm]
                                 902.4               26.83
                                 915.2               27.17
                                 927.6               27.18




ACS Report: 15-0513.W06.1B              Advanced Compliance Solutions                  Page 15


      Model: M2 Gateway2                FCC ID: SK9M2LG2                  IC: 864G-M2LG2

7.4     Channel Usage Requirements

7.4.1    Carrier Frequency Separation – FCC 15.247(a)(1) IC: RSS-247 5.1(2)

7.4.1.1 Measurement Procedure

The RF output port of the EUT was directly connected to the input of the spectrum analyzer using
suitable attenuation. The span of the spectrum analyzer was set wide enough to capture two
adjacent peaks. The RBW was set to approximately 30% of the channel spacing and adjusted as
necessary to best identify the center of each channel. The VBW was set > RBW.

7.4.1.2 Measurement Results




                               Figure 7.4.1.2-1: Frequency Separation




ACS Report: 15-0513.W06.1B              Advanced Compliance Solutions                  Page 16


    Model: M2 Gateway2                   FCC ID: SK9M2LG2                 IC: 864G-M2LG2


7.4.2   Number of Hopping Channels – FCC 15.247(a)(1)(i) IC: RSS-247 5.1(3)

7.4.2.1 Measurement Procedure

The RF output port of the EUT was directly connected to the input of the spectrum analyzer using
suitable attenuation. The span of the spectrum analyzer was set wide enough to capture the
frequency band of operation. The RBW was set to < 30% of the channel spacing and VBW set to
≥ RBW.

7.4.2.2 Measurement Results




                              Figure 7.4.2.2-1: No. of Hopping Channels




ACS Report: 15-0513.W06.1B               Advanced Compliance Solutions                 Page 17


    Model: M2 Gateway2                        FCC ID: SK9M2LG2                IC: 864G-M2LG2


7.4.3    Channel Dwell Time – FCC 15.247(a)(1)(i) IC: RSS-247 5.1(3)

7.4.3.1 Measurement Procedure

The RF output port of the EUT was directly connected to the input of the spectrum analyzer using
suitable attenuation. The span of the spectrum analyzer display was set 0 Hz centered on a
hopping channel. The RBW of the spectrum analyzer was set to ≤ the EUT channel spacing and
VBW set to ≥ RBW. The Marker Delta function of the analyzer was utilized to determine the dwell
time.

7.4.3.2 Measurement Results




                                          Figure 7.4.3.2-1: Dwell Time


Detailed description of timing provided in theory of operation.




ACS Report: 15-0513.W06.1B                    Advanced Compliance Solutions             Page 18


    Model: M2 Gateway2                      FCC ID: SK9M2LG2                  IC: 864G-M2LG2


7.4.4     20dB / 99% Bandwidth - FCC 15.247(a)(1)(i) IC: RSS-247 5.1(3)

7.4.4.1    Measurement Procedure

The RF output port of the EUT was directly connected to the input of the spectrum analyzer using
suitable attenuation. The span of the spectrum analyzer display was set between two times and
five times the occupied bandwidth (OBW) of the emission. The RBW of the spectrum analyzer
was set to approximately 1 % to 5 % of the OBW. The trace was set to max hold with a peak
detector active. The marker delta measurement function of the analyzer was utilized to determine
the 20 dB bandwidth of the emission.

The occupied bandwidth measurement function of the spectrum analyzer was used to measure
the 99% bandwidth. The span of the analyzer was set to capture all products of the modulation
process, including the emission sidebands. The resolution bandwidth was set to 1% to 5% of the
occupied bandwidth. The video bandwidth was set to 3 times the resolution bandwidth. A peak
detector was used.

7.4.4.2    Measurement Results

                            Table 7.4.4.2-1: 20dB / 99% Bandwidth
                   Frequency           20dB Bandwidth         99% Bandwidth
                     [MHz]                    [kHz]                [kHz]
                      902.4                  228.67               297.40
                      915.2                  156.14               298.12
                      927.6                  229.02               241.68




           Figure 7.4.4.2-1: 20dB BW Low Channel      Figure 7.4.4.2-2: 20dB BW Mid Channel




ACS Report: 15-0513.W06.1B                  Advanced Compliance Solutions                     Page 19


   Model: M2 Gateway2                    FCC ID: SK9M2LG2                  IC: 864G-M2LG2




       Figure 7.4.4.2-3: 20dB BW High Channel       Figure 7.4.4.2-4: 99% BW Low Channel




        Figure 7.4.4.2-5: 99% BW Mid Channel       Figure 7.4.4.2-6: 99% BW High Channel




ACS Report: 15-0513.W06.1B               Advanced Compliance Solutions                     Page 20


      Model: M2 Gateway2                      FCC ID: SK9M2LG2                 IC: 864G-M2LG2


7.5     Band-Edge Compliance and Spurious Emissions

7.5.1     Band-Edge Compliance of RF Conducted Emissions - FCC 15.247(d); IC RSS-247
          5.5

7.5.1.1    Measurement Procedure

The RF output port of the EUT was directly connected to the input of the spectrum analyzer using
suitable attenuation. The EUT was investigated at the lowest and highest channel available to
determine band-edge compliance. For each measurement the spectrum analyzer’s RBW was set
to 100 kHz, and the VBW was set to 300 kHz.


7.5.1.2    Measurement Results

NON-HOPPING MODE:




        Figure 7.5.1.2-1: Lower Band Edge                      Figure 7.5.1.2-2: Upper Band Edge




HOPPING MODE:




  Figure 7.5.1.2-3: Lower Band Edge Hopping                Figure 7.5.1.2-4: Upper Band Edge Hopping




ACS Report: 15-0513.W06.1B                    Advanced Compliance Solutions                  Page 21


    Model: M2 Gateway2                     FCC ID: SK9M2LG2                      IC: 864G-M2LG2


7.5.2   RF Conducted Spurious Emissions - FCC 15.247(d); IC RSS-247 5.5

7.5.2.1 Measurement Procedure

The RF output port of the EUT was directly connected to the input of the spectrum analyzer using
suitable attenuation. The EUT was investigated for conducted spurious emissions from 30MHz to
10GHz, 10 times the highest fundamental frequency. Measurements were made at the low,
center and high channels of the EUT. For each measurement, the spectrum analyzer’s RBW was
set to 100kHz. A peak detector function was used with the trace set to max hold.


7.5.2.2 Measurement Results




          Figure 7.5.2.2-1: 30 MHz – 10 GHz – LCH     Figure 7.5.2.2-2: 30 MHz – 10 GHz – MCH




                                Figure 7.5.2.2-3: 30 MHz – 10 GHz – HCH




ACS Report: 15-0513.W06.1B                 Advanced Compliance Solutions                        Page 22


    Model: M2 Gateway2                         FCC ID: SK9M2LG2                         IC: 864G-M2LG2


7.5.3   Radiated Spurious Emissions - FCC 15.205, 15.209; RSS-Gen 8.9/8.10

7.5.3.1 Measurement Procedure

Radiated emissions tests were made over the frequency range of 30MHz to 10GHz, 10 times the
highest fundamental frequency.

The EUT was rotated through 360° and the receive antenna height was varied from 1m to 4m so
that the maximum radiated emissions level would be detected. For frequencies below 1000MHz,
quasi-peak measurements were made using a resolution bandwidth RBW of 120 kHz and a video
bandwidth VBW of 300 kHz. For frequencies above 1000MHz, peak and average measurements
were made with RBW and VBW of 1 MHz and 3MHz respectively.

The EUT was caused to generate a continuous modulated carrier on the hopping channel.
犢Each emission found to be in a restricted band was compared to the applicable radiated
Each emission found to be in a restricted band was compared to the applicable radiated emission
limits.

7.5.3.2 Measurement Results

               Table 7.5.3.2-1: Radiated Spurious Emissions Tabulated Data
                       Level       Antenna      Correction     Corrected Level       Limit              Margin
  Frequency           (dBuV)       Polarity      Factors          (dBuV/m)         (dBuV/m)              (dB)
    (MHz)
               pk        Qpk/Avg    (H/V)          (dB)         pk     Qpk/Avg   pk     Qpk/Avg    pk     Qpk/Avg
                                               Low Channel
    2702.2    50.04        43.38      H           -3.75        46.29    39.63    74.0    54.0     27.7      14.4
    2702.2    47.35        36.99      V           -3.75        43.60    33.24    74.0    54.0     30.4      20.8
                                              Middle Channel
    2745.6    49.10        42.09      H           -3.66        45.44    38.43    74.0    54.0     28.6      15.6
    2745.6    48.11        39.80      V           -3.66        44.45    36.14    74.0    54.0     29.5      17.9
     4576     47.04        36.35      H            1.05        48.09    37.40    74.0    54.0     25.9      16.6
                                              High Channel
    2782.8    49.77        40.21      H           -3.56        46.21    36.65    74.0    54.0     27.8      17.4
    2782.8    49.51        42.83      V           -3.56        45.95    39.27    74.0    54.0     28.1      14.7
     4638     47.05        35.69      H            1.23        48.28    36.92    74.0    54.0     25.7      17.1
    7420.8    44.18        32.57      H            7.98        52.16    40.55    74.0    54.0     21.8      13.5




ACS Report: 15-0513.W06.1B                     Advanced Compliance Solutions                             Page 23


   Model: M2 Gateway2                  FCC ID: SK9M2LG2                IC: 864G-M2LG2

7.5.3.3 Sample Calculation:
RC = RU + CFT

Where:
CFT      =     Total Correction Factor (AF+CA+AG)-DC (Average Measurements Only)
RU       =     Uncorrected Reading
RC       =     Corrected Level
AF       =     Antenna Factor
CA       =     Cable Attenuation
AG       =     Amplifier Gain
DC       =     Duty Cycle Correction Factor

Example Calculation: Peak

Corrected Level: 50.04 - 3.75 = 46.29dBuV/m
Margin: 74dBuV/m – 46.29dBuV/m = 27.7dB

Example Calculation: Average

Corrected Level: 43.38 - 3.75 - 0 = 39.63dBuV
Margin: 54dBuV – 39.63dBuV = 14.4dB




ACS Report: 15-0513.W06.1B             Advanced Compliance Solutions               Page 24


    Model: M2 Gateway2                  FCC ID: SK9M2LG2                    IC: 864G-M2LG2

8   CONCLUSION

In the opinion of ACS, Inc. the M2 Gateway2, manufactured by Itron Electricity Metering, Inc.
meets the requirements of FCC Part 15 subpart C and Industry Canada’s Radio Standards
Specification RSS-247.




                                     END REPORT




ACS Report: 15-0513.W06.1B              Advanced Compliance Solutions                    Page 25



Document Created: 2016-03-07 09:42:00
Document Modified: 2016-03-07 09:42:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC