Test Report

FCC ID: SK9ITR9002

Test Report

Download: PDF
FCCID_4320500

                                              Certification Test Report

                                                          FCC ID: SK9ITR9002

                                                         FCC Rule Part: 15.247

                                           Report Number: AT72148094-3P0


                                                          Manufacturer: Itron Inc
                                                            Model: ITR9002

                                                Test Begin Date: April 22, 2019
                                                 Test End Date: April 22, 2019

                                              Report Issue Date: May 20, 2019




                                 FOR THE SCOPE OF ACCREDITATION UNDER Certificate Number: 2955.09

This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the
                                                         Federal Government.

               Prepared By:                                                                   Reviewed by:




               Tyler Leeson                                                                   Jeremy Pickens
               Lab Technician                                                                 Senior Engineer
               TÜV SÜD America Inc.                                                           TÜV SÜD America Inc.
This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of TÜV SÜD America Inc. The results contained
                                               in this report are representative of the sample(s) submitted for evaluation.
                                                          This report contains 13 pages




                                                  5945 Cabot Pkwy, Suite 100, Alpharetta, GA 30005


                                                          TABLE OF CONTENTS
1      GENERAL ............................................................................................................................................ 3
    1.1       PURPOSE.......................................................................................................................................... 3
    1.2       APPLICANT INFORMATION ............................................................................................................... 3
    1.3       PRODUCT DESCRIPTION ................................................................................................................... 3
    1.4       TEST METHODOLOGY AND CONSIDERATIONS ................................................................................. 3
2      TEST FACILITIES .............................................................................................................................. 4
    2.1     LOCATION ....................................................................................................................................... 4
    2.2     LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS ................................................ 4
    2.3     RADIATED EMISSIONS TEST SITE DESCRIPTION .............................................................................. 5
       2.3.1    Semi-Anechoic Chamber Test Site – Chamber A .................................................................... 5
       2.3.2    Semi-Anechoic Chamber Test Site – Chamber B .................................................................... 6
    2.4     CONDUCTED EMISSIONS TEST SITE DESCRIPTION ........................................................................... 7
       2.4.1    Conducted Emissions Test Site ............................................................................................... 7
3      APPLICABLE STANDARD REFERENCES.................................................................................... 8

4      LIST OF TEST EQUIPMENT ............................................................................................................ 8

5      SUPPORT EQUIPMENT .................................................................................................................... 9

6      EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ........................................................... 9

7      SUMMARY OF TESTS ......................................................................................................................10
    7.1     ANTENNA REQUIREMENT – FCC 15.203 ........................................................................................10
    7.2     POWER LINE CONDUCTED EMISSIONS – FCC 15.207, ISED CANADA: RSS-GEN 8.8.....................10
       7.2.1    Measurement Procedure ........................................................................................................10
       7.2.2    Measurement Results .............................................................................................................10
    7.3     EMISSION LEVELS ..........................................................................................................................12
       7.3.1    Emissions into Restricted Frequency Bands – FCC: 15.205, 15.209 ....................................12
           7.3.1.1       Measurement Procedure ................................................................................................................... 12
           7.3.1.2       Measurement Results ....................................................................................................................... 12
       7.3.2          Sample Calculation: ..............................................................................................................13
8      CONCLUSION ....................................................................................................................................13




                                              5945 Cabot Pkwy, Suite 100, Alpharetta, GA 30005


Model(s): ITR9002                                                         FCC ID: SK9ITR9002

1     GENERAL

1.1    Purpose

The purpose of this report is to demonstrate compliance with Part 15 Subpart C of the FCC’s
Code of Federal Regulations and Innovation, Science and Economic Development Canada’s
Radio Standards Specification RSS-247 for the tests documented herein.

1.2    Applicant Information

Itron, Inc.
313 N Hwy 11
West Union, SC 29696

1.3    Product Description
The Itron ITR9002 is a transmitter module that operates in the 902 MHz to 928 MHz unlicensed
band. The module operates on direct current voltage which is supplied by a host device.

Technical Details

               Detail                                       Description
        Frequency Range                                  902.25 – 927.75
        Operating Voltage                                     12VDC
       Antenna Type / Gain            External Omnidirectional / 3dBi (Laird, P/N: TRA9023P)
          Manufacturer                                       Itron Inc
             FCC ID                                        SK9ITR9002
Test Sample Serial Number(s): Not Labeled

Test Sample Condition: The equipment was provided in good condition without any physical
damage.

1.4    Test Methodology and Considerations

This is a Class 2 Permissive Change to add a new antenna (Laird, P/N: TRA9023P).

For radiated emissions, the EUT was evaluated in a fixed orientation as intended during normal
installation.

For power line conducted emissions, the EUT was evaluated in the host using the provided AC
cable.

Power setting during test:     20




Report: AT72146019-1P0              TÜV SÜD America, Inc.                              Page 3


Model(s): ITR9002                                                           FCC ID: SK9ITR9002

2     TEST FACILITIES

2.1    Location

The radiated and conducted emissions test sites are located at the following addresses:


        TÜV SÜD America, Inc.
        5945 Cabot Pkwy, Suite 100
        Alpharetta, GA 30005
        Phone: (678) 341-5900


2.2    Laboratory Accreditations/Recognitions/Certifications

TÜV SÜD America, Inc. is accredited to ISO/IEC 17025 by the American Association for
Laboratory Accreditation/A2LA accreditation program and has been issued certificate number
2955.09 in recognition of this accreditation.

Unless otherwise specified, all tests methods described within this report are covered under the
ISO/IEC 17025 scopes of accreditation.

The Semi-Anechoic Chamber Test Sites and Conducted Emissions Sites have been fully
described, submitted to, and accepted by the FCC, ISED Canada and the Japanese Voluntary
Control Council for Interference by information technology equipment.

FCC Registration Number:                967699
ISED Canada Lab Code:                   23932
VCCI Member Number:                     1831
   VCCI Registration Number            A-0295




Report: AT72146019-1P0              TÜV SÜD America, Inc.                                  Page 4


Model(s): ITR9002                                                             FCC ID: SK9ITR9002

2.3     Radiated Emissions Test Site Description

2.3.1    Semi-Anechoic Chamber Test Site – Chamber A

The Semi-Anechoic Chamber Test Site consists of a 20’ x 30’ x 18’ shielded enclosure. The
chamber is lined with Toyo Ferrite Grid Absorber, model number FFG-1000. The ferrite tile grid is
101 x 101 x 19mm thick and weighs approximately 550 grams. These tiles are mounted on steel
panels and installed directly on the inner walls of the chamber.

The turntable is 5’ in diameter and is located 5’6” from the back wall of the chamber. The
chamber is grounded via 1 - 8’ copper ground rod, installed at the center of the back wall, it is
bound to the ground plane using 3/4" stainless steel braided cable.

The turntable is all steel, flush mounted EMCO Model 1060 installed in an all steel frame. The
table is remotely operated from inside the control room located 25’ from the range. The turntable
is electrically bonded to the surrounding ground plane via steel fingers installed on the edge of
the turn table. The steel fingers make constant contact with the ground plane during operation.

Behind the turntable is a 3’ x 6’ x 4’ deep shielded pit used for support equipment if necessary.
The pit is equipped with 1 - 4” PVC chase from the turntable to the pit that allows for cabling to
the EUT if necessary. The underside of the turntable can be accessed from the pit so cables can
be supplied to the EUT from the pit.

The chamber rear wall is covered with a mixture of Siepel pyramidal absorber. The side walls of
the chamber are partially covered with Siepel pyramidal absorber.
                                            30’




                               Dimensions Not to Scale                        5’6”
                                                                                          20’

               9’8”

                                                  3 Meters


                   4’3”




               Figure 2.3.1-1: Semi-Anechoic Chamber Test Site – Chamber A



Report: AT72146019-1P0                TÜV SÜD America, Inc.                                     Page 5


Model(s): ITR9002                                                        FCC ID: SK9ITR9002

2.3.2   Semi-Anechoic Chamber Test Site – Chamber B

The Semi-Anechoic Chamber Test Site consists of a 20’W x 30’L x 20’H shielded enclosure. The
chamber is lined with ETS-Lindgren Ferrite Absorber, model number FT-1500. The ferrite tile 600
mm x 600 mm (2.62 in x 23.62 in) panels and are mounted directly on the inner walls of the
chamber shield.

The specular regions of the chamber are lined with additional ETS-Lindgren PS-600 hybrid
absorber to extend its frequency range up to 18GHz and beyond.

The turntable is a 2m ETS-Lindgren Model 2170 and installed off the center axis is located 5’6”
from the back wall of the chamber. The chamber is grounded via 1 - 8’ copper ground rod,
installed at the center of the back wall, it is bound to the shield using #8 solid copper wire.

The antenna mast is an EMCO 1060 and is remotely controlled from the control room for both
antenna height and polarization.




              Figure 2.3.2-1: Semi-Anechoic Chamber Test Site – Chamber B




Report: AT72146019-1P0             TÜV SÜD America, Inc.                               Page 6


Model(s): ITR9002                                                         FCC ID: SK9ITR9002


2.4     Conducted Emissions Test Site Description

2.4.1    Conducted Emissions Test Site

The AC mains conducted EMI site is located in the main EMC lab. It consists of a 12’ x 10’
horizontal coupling plane (HCP) as well as a 12’x8’ vertical coupling plane (VCP). The HGP is
constructed of 4’ x 10’ sheets of particle board sandwiched by galvanized steel sheets. These
panels are bonded using 11AWG 1/8” x 2” by 10’ galvanized sheet steel secured to the panels via
by screws. The VCP is constructed of three 4’x8’ sheets of 11AWG solid aluminum.

The HCP and VCP are electrically bonded together using 1”x1” angled aluminum secured with
screws.

The site is of sufficient size to test table top and floor standing equipment in accordance with
section 6.1.4 of ANSI C63.10.




                     Vertical Ground Plane
                     (12’ x 8’)




                                                  Non-Conductive EUT Table
                                                      (1m x 1.5m x .8m)


             .4 Meters




               .8 Meters

                                                    Horizontal Ground Plane
                                                    (12’ x 10’)
              LISN

                           Figure 2.4.1-1: AC Mains Conducted EMI Site




Report: AT72146019-1P0               TÜV SÜD America, Inc.                              Page 7


Model(s): ITR9002                                                                                                      FCC ID: SK9ITR9002


3       APPLICABLE STANDARD REFERENCES

The following standards were used:

              ANSI C63.10-2013: American National Standard of Procedures for Compliance Testing of
               Unlicensed Wireless Devices.
              US Code of Federal Regulations (CFR): Title 47, Part 2, Subpart J: Equipment Authorization
               Procedures, 2019
              US Code of Federal Regulations (CFR): Title 47, Part 15, Subpart C: Radio Frequency Devices,
               Intentional Radiators, 2019

4       LIST OF TEST EQUIPMENT

The calibration interval of test equipment is annually or the manufacturer’s recommendations.
Where the calibration interval deviates from the annual cycle based on the instrument
manufacturer’s recommendations, it shall be stated below.

                                                       Table 4-1: Test Equipment
    Asset ID         Manufacturer              Model                        Equipment Type                 Serial Number     Last Calibration Date Calibration Due Date
      30         Spectrum Technologies        DRH-0118                    1-18GHz Horn Antenna                 970102            05/09/2017            05/09/2019
      213                TEC                   PA 102                             Amplifier                     44927            07/19/2018            07/19/2019
      324                ACS                   Belden                      Conducted EMI Cable                  8214              3/19/2019             3/19/2020
      331          Microwave Circuits         H1G513G1                  Microwave Bandpass Filter               31417            05/16/2018            05/16/2019
      338           Hewlett Packard             8449B                    High Frequency Pre-Amp              3008A01111          07/11/2017            07/11/2019
      432          Microwave Circuits         H3G020G4                         Highpass Filter                 264066            05/16/2018            05/16/2019
      654            Micro-Tronics            BRC50722                       Band Reject Filter                  -10              4/23/2019             4/23/2020
                                                                EMI Receiver; RF Input 50ohm; 10Hz-50MHz;
      813                PMM                    9010                                                        697WW30606           02/12/2018            02/12/2019
                                                                                10Hz-30MHz
      819          Rohde & Schwarz              ESR26                        EMI Test Receiver                 101345            11/06/2018            11/06/2019
      836            ETS Lindgren            SAC Cable Set          SAC Cable Set includes 620, 837, 838         N/A             05/01/2018            05/01/2019
      853               Teseq            CBL 6112D; 6804.17.A           Bilog Antenna; Attenuator         51616; 20181110A       10/15/2018            10/15/2019
     3010          Rohde & Schwarz             ENV216                      Two-Line V-Network                   3010             07/11/2018            07/11/2019


NCR = No Calibration Required

NOTE: All test equipment was used only during active calibration cycles as reported above.




Report: AT72146019-1P0                                   TÜV SÜD America, Inc.                                                                    Page 8


Model(s): ITR9002                                                    FCC ID: SK9ITR9002

5       SUPPORT EQUIPMENT

                               Table 5-1: Support Equipment
Item       Equipment Type        Manufacturer        Model Number       Serial Number
    1           Host                Itron Inc               PMR          FCC1/FCC2
    2           EUT                 Itron Inc              ITR9002           N/A

                                Table 5-2: Cable Description
Item         Cable Type             Length                 Shield        Termination
    A         AC Power               150 cm                  No             1 - AC

6       EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM




                                       2
                                                1




                                                     A




                            Figure 6-1: Test Setup Block Diagram




Report: AT72146019-1P0             TÜV SÜD America, Inc.                           Page 9


Model(s): ITR9002                                                              FCC ID: SK9ITR9002

7      SUMMARY OF TESTS

Along with the tabular data shown below, plots were taken of all signals deemed important
enough to document.

7.1     Antenna Requirement – FCC 15.203

The EUT utilizes an external omnidirectional antenna (Laird, P/N TRA9023P). When installed, the
antenna is external to the host and is non-detachable. The gain of the antenna is +3dBi.

7.2     Power Line Conducted Emissions – FCC 15.207, ISED Canada: RSS-Gen 8.8

7.2.1        Measurement Procedure

ANSI C63.10 section 6 was the guiding documents for this evaluation. Conducted emissions
were performed from 150kHz to 30MHz with the spectrum analyzer’s resolution bandwidth set to
9kHz and the video bandwidth set to 30kHz. The calculation for the conducted emissions is as
follows:

Corrected Reading = Analyzer Reading + LISN Loss + Cable Loss
Margin = Corrected Reading – Applicable Limit

7.2.2        Measurement Results
Performed by: Tyler Leeson

                             Table 7.2.2-1: Conducted EMI Results Line 1

                  Corrected Reading             Limit                          Margin
Frequency
  (MHz)
                 Quasi-
                             Average   Quasi-Peak       Average   Quasi-Peak   Average   Correction
                  Peak
                              (dBuV)    (dBuV)           (dBuV)      (dB)        (dB)       (dB)
                 (dBuV)
     0.15         25.07       13.53        66             56        -40.93      -42.47      9.61
     2.63         19.27       10.93        56             46        -36.73      -35.07      9.94
     2.67         19.29       10.95        56             46        -36.71      -35.05      9.94
    2.718         19.31       10.97        56             46        -36.69      -35.03      9.94
    2.802         19.33       10.99        56             46        -36.67      -35.01      9.94
    2.906         19.37       11.03        56             46        -36.63      -34.97      9.96
     2.95         19.38       11.04        56             46        -36.62      -34.96      9.96
    2.986         19.4        11.06        56             46        -36.6       -34.94      9.96
     9.59         19.27       10.93        60             50        -40.73      -39.07      9.94
    29.982        25.02       13.41        60             50        -34.98      -36.59      9.96




Report: AT72146019-1P0                 TÜV SÜD America, Inc.                              Page 10


Model(s): ITR9002                                                        FCC ID: SK9ITR9002

                      Table 7.2.2-2: Conducted EMI Results Line 2

            Corrected Reading             Limit                          Margin
Frequency
  (MHz)
            Quasi-
                      Average   Quasi-Peak        Average   Quasi-Peak   Average   Correction
             Peak
                       (dBuV)    (dBuV)            (dBuV)      (dB)        (dB)       (dB)
            (dBuV)
  0.15       25.09      13.11       66              56        -40.91      -42.89      9.62
  0.154     25.64       13.92     65.78            55.78      -40.14      -41.86      9.62
  2.558     19.21       10.87       56              46        -36.79      -35.13      9.89
  2.634     19.23       10.89       56              46        -36.77      -35.11      9.89
  2.682     19.25       10.91       56              46        -36.75      -35.09      9.89
  2.826     19.53       10.94       56              46        -36.47      -35.06      9.89
  2.854     20.24       10.95       56              46        -35.76      -35.05      9.9
  2.878      19.3       10.96       56              46        -36.7       -35.04      9.9
  2.986     19.34        11         56              46        -36.66       -35        9.9
 29.998     24.51        13.5       60              50        -35.49       -36.5     10.05




Report: AT72146019-1P0          TÜV SÜD America, Inc.                               Page 11


Model(s): ITR9002                                                                         FCC ID: SK9ITR9002

7.3      Emission Levels

7.3.1      Emissions into Restricted Frequency Bands – FCC: 15.205, 15.209

7.3.1.1 Measurement Procedure

The unwanted emissions into restricted bands were measured radiated over the frequency range
of 30MHz to 10GHz, 10 times the highest fundamental frequency.

The EUT was rotated through 360° and the receive antenna height was varied from 1 meter to 4
meters so that the maximum radiated emissions level would be detected. For frequencies below
1000 MHz, quasi-peak measurements were made using a resolution bandwidth RBW of 120 kHz
and a video bandwidth VBW of 300 kHz. For frequencies above 1000 MHz, peak and average
measurements were made with RBW and VBW of 1 MHz and 3 MHz respectively.

Each emission found to be in a restricted band as defined by section 15.205, including any
emission at the operational band-edge, was compared to the radiated emission limits as defined
in section 15.209.

7.3.1.2 Measurement Results
Performed by: Tyler Leeson

                  Table 7.3.1.2-1: Radiated Spurious Emissions Tabulated Data
                          Level       Antenna    Correction      Corrected Level       Limit              Margin
  Frequency              (dBuV)       Polarity    Factors           (dBuV/m)         (dBuV/m)              (dB)
    (MHz)
                  pk        Qpk/Avg    (H/V)        (dB)          pk     Qpk/Avg   pk     Qpk/Avg    pk     Qpk/Avg
                                                    902.25 MHz
      5413.5     48.65       36.75       V          5.87         54.52    42.62    74.0    54.0     19.5      11.4
                                                      914.75
      2744.25    48.80       35.94       V         -2.37         46.43    33.57    74.0    54.0     27.6      20.4
      4573.75    49.26       37.16       V          3.05         52.31    40.21    74.0    54.0     21.7      13.8
                                                      927.75
      4638.75    49.33       36.37       V          3.34         52.67    39.71    74.0    54.0     21.3      14.3




Report: AT72146019-1P0                       TÜV SÜD America, Inc.                                         Page 12


Model(s): ITR9002                                                       FCC ID: SK9ITR9002

7.3.2 Sample Calculation:
RC = RU + CFT

Where:
CFT      =     Total Correction Factor (AF+CA+AG)-DC (Average Measurements Only)
RU       =     Uncorrected Reading
RC       =     Corrected Level
AF       =     Antenna Factor
CA       =     Cable Attenuation
AG       =     Amplifier Gain
DC       =     Duty Cycle Correction Factor

Example Calculation: Peak – Horizontal Polarity – 5413.5 MHz

Corrected Level: 48.65 + 5.87 = 54.52dBuV/m
Margin: 74dBuV/m – 54.52dBuV/m = 19.5dB

Example Calculation: Average –Horizontal Polarity – 5413.5 MHz

Corrected Level: 36.75 + 5.87 - 0 = 42.62dBuV
Margin: 54dBuV – 42.62dBuV = 11.4dB

8   CONCLUSION

In the opinion of TUV SUD the ITR9002, manufactured by Itron Inc meets the requirements of
FCC Part 15 subpart C for the tests documented herein.




                                   END REPORT