RF Exposure

FCC ID: SK9ITR900-1

RF Exposure Info

Download: PDF
FCCID_1251850

                   Certification Exhibit



                      FCC ID: SK9ITR900-1
                        IC: 864G-ITR9001

              FCC Rule Part: 15.247
    IC Radio Standards Specification: RSS-210

           ACS Report Number: 10-0009-15C

      Manufacturer: Itron Electricity Metering, Inc.
                    Model: ITR900




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: ITR900                             FCC ID: SK9ITR900-1                        IC: 864G-ITR9001


General Information:
Applicant:               Itron Electricity Metering, Inc.
ACS Project:             10-0009
Device Category:         Mobile
Environment:             General Population/Uncontrolled Exposure

Technical Information:
Antenna Type: Omni-Directional 900 MHz Mobile Antenna
Antenna Gain: 5.1dBi
Maximum Transmitter Conducted Power: 26.15dBm, 412.1mW
Maximum System EIRP: 31.25dBm, 1.333W
Exposure Conditions: Greater than 20 centimeters

MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

       PG
S=
      4R 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                 MPE Calculator for Mobile Equipment
                        Limits for General Population/Uncontrolled Exposure*
  Transmit       Radio         Power        Radio    Antenna Antenna                             Power
                                                                        Distance
 Frequency       Power     Density Limit    Power      Gain      Gain                            Density
                                                                          (cm)
   (MHz)         (dBm)       (mW/Cm2)       (mW)       (dBi)   (mW eq.)                        (mW/cm^2)
     902.25       26.15         0.60        412.10      5.1      3.236     20                     0.265


Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




 ACS Report: 10-0009-15C                      Advanced Compliance Solutions                         Page 2



Document Created: 2010-01-29 15:15:56
Document Modified: 2010-01-29 15:15:56