TEST REPORT

FCC ID: SK9C3A-1L

Test Report

Download: PDF
FCCID_640371

                                               FCC Part 15.247
                                            Transmitter Certification
                      Frequency Hopping Spread Spectrum Transmitter

                                                               Test Report
                                                         FCC ID: SK9C3A-1L

                                                       FCC Rule Part: 15.247

                                        ACS Report Number: 06-0013-15C

                                 Manufacturer: Itron Electricity Metering Inc.
                                    Trade name: CENTRON® IMAGE
                                               Model: C3A1L

                                           Test Begin Date: October 11 2005
                                           Test End Date: January 20, 2006

                                      Report Issue Date: February 27, 2006




                                                FOR THE SCOPE OF ACCREDITATION UNDER LAB Code 200612




Prepared by:                                                                       Reviewed by:
Ken Rivers                                                                         Kirby Munroe
Engineering Technician                                                             Manager Wireless Certifications
ACS, Inc.                                                                          ACS, Inc.

This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this
                                               report are representative of the sample(s) submitted for evaluation.
                                                        This report contains 29 pages



                       5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Table of Contents
1.0 General                                                                                         3
     1.1 Purpose                                                                                    3
     1.2 Product Description                                                                        3
          1.2.1 General                                                                             3
          1.2.2 Manufacturer                                                                        3
2.0 Test Facilities                                                                                 3
     2.1 Location                                                                                   3
     2.2 Laboratory Accreditations/Recognitions/Certifications                                      3
     2.3 Radiated Emissions Test Site Description                                                   4
          2.3.1 Semi-Anechoic Chamber Test Site                                                     4
          2.3.2 Open Area Tests Site (OATS)                                                         5
     2.4 Conducted Emissions Test Site Description                                                  6
3.0 Applicable Standards and References                                                             6
4.0 List of Test Equipment                                                                          7
5.0 Support Equipment                                                                               8
6.0 EUT Setup Block Diagram                                                                         8
7.0 Summary of Tests                                                                                9
     7.1 Section 15.203 - Antenna Requirement                                                       9
     7.2 Section 15.207 - Power Line Conducted Emissions                                            9
          7.2.1 Test Methodology                                                                    9
          7.2.2 Test Results                                                                        9
     7.3 Section 15.109 - Radiated Emissions (Unintentional Radiation)                              17
          7.3.1 Test Methodology                                                                    17
          7.3.2 Test Results                                                                        17
     7.4 Section 15.247(b) – Peak Output Power                                                      18
          7.4.1 Test Methodology                                                                    18
          7.4.2 Test Results                                                                        18
     7.5 Section 15.247(a) – Channel Usage                                                          19
          7.5.1 Section 15.247(a) (1) - Carrier Frequency Separation                                20
                   7.5.1.1 Test Methodology                                                         20
                   7.5.1.2 Test Results                                                             20
          7.5.2 Section 15.247(a) (1) – Number of Hopping Channels                                  20
          7.5.3 Section 15.247(a) (1) – Channel Dwell Time                                          21
          7.5.4 Section 15.247(a) (1) (iii) – 20dB Bandwidth                                        22
                   7.5.4.1 Test Methodology                                                         22
                   7.5.4.2 Test Results                                                             22
     7.6 Section 15.247(c) – Band-edge Compliance and Spurious Emissions                            24
          7.6.1 Band-edge Compliance of RF Conducted Emissions                                      24
                   7.6.1.1 Test Methodology                                                         24
                   7.6.1.2 Test Results                                                             24
          7.6.2 RF Conducted Spurious Emissions                                                     25
                   7.6.2.1 Test Methodology                                                         25
                   7.6.2.2 Test Results                                                             25
          7.6.3 Radiated Spurious Emissions (Restricted Bands)                                      27
                 7.6.3.1 Test Methodology                                                           27
                 7.6.3.2 Duty Cycle Correction                                                      28
                 7.6.3.3 Test Results                                                               28
                 7.6.3.4 Sample Calculations

8.0 CONCLUSION                                                                                      29

Additional Exhibits Included In Filing

Internal Photographs                                    Installation/Users Guide
External Photographs                                    Theory of Operation
Test Setup Photographs                                  BOM (Parts List)
Product Labeling                                        System Block Diagram
RF Exposure – MPE Calculations
                                                        Schematics


                5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model:   C3A1L                                                                 FCC ID: SK9C3A-1L


1.0 GENERAL

1.1 Purpose
The purpose of this report is to demonstrate compliance with Part 15, Subpart C of the FCC’s Code of
Federal Regulations.

1.2 Product Description

1.2.1 General
The CENTRON® IMAGE is an electricity meter that is capable of being deploying in both C&I and
residential services. This is possible due to the IMAGE personality register being capable of supporting
both polyphase and monophase metrology bases. The meter supports advance metering functions such
as Demand, Time Of Use, Load Profile, KY and KYZ Outputs, SiteScan, Option Boards, and RF. Time Of
Use, Load Profile, and RF features require the use of a soldered in battery. The meter is configurable
with PC Pro+ Advanced software with device types that are distinguished and separately service
polyphase and monophase CENTRON® IMAGE meters.

There are two versions of the IMAGE personality registers available (high power and low power). Some
documents and information provided is generic and general in nature and may reference both versions of
the IMAGE but the purpose of this report and the data contained within is in reference to the low power
version only. The high power version will be addressed in a separate test report and filing under a
separate FCC ID.

1.2.2 Manufacturer
Itron Electricity Metering, Inc.
West Union, South Carolina 29696
313 North Highway 11

2.0 TEST FACILITIES

    2.1 Location
    The radiated and conducted emissions test sites are located at the following address:

      Advanced Compliance Solutions
      5015 B.U. Bowman Drive
      Buford, GA 30518
      Phone: (770) 831-8048
      Fax: (770) 831-8598

   2.2 Laboratory Accreditations/Recognitions/Certifications
   The Semi-Anechoic Chamber Test Site, Open Area Test Site (OATS) and Conducted Emissions Site
   have been fully described, submitted to, and accepted by the FCC, Industry Canada and the
   Japanese Voluntary Control Council for Interference by information technology equipment. In
   addition, ACS is compliant to ISO 17025 as certified by the National Institute of Standards and
   Technology under their National Voluntary Laboratory Accreditation Program. The following
   certification numbers have been issued in recognition of these accreditations and certifications:

   FCC Registration Number: 89450
   Industry Canada Lab Code: IC 4175
   VCCI Member Number: 1831
           ƒ VCCI OATS Registration Number R-1526
           ƒ VCCI Conducted Emissions Site Registration Number: C-1608
   NVLAP Lab Code: 200612




ACS Report: 06-0013-15C                 Advanced Compliance Solutions                        Page 3


Model:    C3A1L                                                                     FCC ID: SK9C3A-1L


   2.3 Radiated Emissions Test Site Description

         2.3.1 Semi-Anechoic Chamber Test Site
         The Semi-Anechoic Chamber Test Site consists of a 20’ x 30’ x 18’ shielded enclosure. The
         chamber is lined with Toyo Ferrite Grid Absorber, model number FFG-1000. The ferrite tile grid
         is 101 x 101 x 19mm thick and weighs approximately 550 grams. These tiles are mounted on
         steel panels and installed directly on the inner walls of the chamber.

         The turntable is 150cm in diameter and is located 160cm from the back wall of the chamber. The
         chamber is grounded via 1 - 8’ copper ground rod, installed at the center of the back wall, it is
         bound to the ground plane using 3/4" stainless steel braided cable.

         The turntable is all steel, flush mounted table installed in an all steel frame. The table is remotely
         operated from inside the control room located 25’ from the range. The turntable is electrically
         bonded to the surrounding ground plane via steel fingers installed on the edge of the turn table.
         The steel fingers make constant contact with the ground plane during operation.

         Behind the turntable is a 3’ x 6’ x 4’ deep shielded pit used for support equipment if necessary.
         The pit is equipped with 1 - 4” PVC chases from the turntable to the pit that allow for cabling to
         the EUT if necessary. The underside of the turntable can be accessed from the pit so cables can
         be supplied to the EUT from the pit.

         A diagram of the Semi-Anechoic Chamber Test Site is shown in Figure 2.3-1 below:



                                               3 Meters




                                                                         5 Feet
                                                                         Diamete
                                                                            r


                                                                                     20 Feet


                                               30 Feet

                            Figure 2.3-1: Semi-Anechoic Chamber Test Site




ACS Report: 06-0013-15C                   Advanced Compliance Solutions                             Page 4


Model:    C3A1L                                                                    FCC ID: SK9C3A-1L


         2.3.2 Open Area Tests Site (OATS)
         The open area test site consists of a 40’ x 66’ concrete pad covered with a perforated electro-
         plated galvanized sheet metal. The perforations in the sheet metal are 1/8” holes that are
         staggered every 3/16”. The individual sheets are placed to overlap each other by 1/4” and are
         riveted together to provide a continuous seam. Rivets are spaced every 3” in a 3 x 20 meter
         perimeter around the antenna mast and EUT area. Rivets in the remaining area are spaced as
         necessary to properly secure the ground plane and maintain the electrical continuity.

         The entire ground plane extends 12’ beyond the turntable edge and 16’ beyond the antenna mast
         when set to a 10 meter measurement distance. The ground plane is grounded via 4 - 8’ copper
         ground rods, each installed at a corner of the ground plane and bound to the ground plane using
         3/4" stainless steel braided cable.

         The turntable is an all aluminum 10’ flush mounted table installed in an all aluminum frame. The
         table is remotely operated from inside the control room located 40’ from the range. The turntable
         is electrically bonded to the surrounding ground plane via steel fingers installed on the edge of
         the turn table. The steel fingers make constant contact with the ground plane during operation.

         Adjacent to the turntable is a 7’ x 7’ square and 4’ deep concrete pit used for support equipment if
         necessary. The pit is equipped with 5 - 4” PVC chases from the pit to the control room that allow
         for cabling to the EUT if necessary. The underside of the turntable can be accessed from the pit
         so cables can be supplied to the EUT from the pit. The pit is covered with 2 sheets of 1/4"
         diamond style re-enforced steel sheets. The sheets are painted to match the perforated steel
         ground plane; however the underside edges have been masked off to maintain the electrical
         continuity of the ground plane. All reflecting objects are located outside of the ellipse defined in
         ANSI C63.4.

         A diagram of the Open Area Test Site is shown in Figure 2.3-2 below:



                                                  10

                                                             3 Meters



                                                                                       40




                                                                           7x7x4
                                                                            Pit

                                               66 Feet

                                    Figure 2.3-2: Open Area Test Site




ACS Report: 06-0013-15C                   Advanced Compliance Solutions                           Page 5


Model:   C3A1L                                                                FCC ID: SK9C3A-1L


   2.4 Conducted Emissions Test Site Description
   The AC mains conducted EMI site is a shielded room with the following dimensions:

         ¾   Height: 3.0 Meters
         ¾   Width: 3.6 Meters
         ¾   Length: 4.9 Meters

   The room is manufactured by Rayproof Corporation and installed by Panashield, Inc. Earth ground is
   provided to the room via an 8’ copper ground rod. Each panel of the room is connected electrically at
   intervals of 4”.

   Power to the room is filtered to prevent ambient noise from coupling to the EUT and measurement
   equipment. Filters are models 1B42-60P manufactured by Rayproof Corporation.

   The room is of sufficient size to test table top and floor standing equipment in accordance with
   section 6.1.4 of ANSI C63.4.

   A diagram of the room is shown below in figure 2.4-1:

                  Non-EUT LISN

                                           4.9 Meters

   0.4 Meters


              1.0 Meter


                                                                                     3.0 Meters


                   1.5 Meters




     0.8 Meters


                    EUT LISN

                            Figure 2.4-1: AC Mains Conducted EMI Site

3.0 APPLICABLE STANDARD REFERENCES
The following standards were used:

   ™ ANSI C63.4-2003: Method of Measurements of Radio-Noise Emissions from Low-Voltage
     Electrical and Electronic Equipment in the 9KHz to 40GHz
   ™ US Code of Federal Regulations (CFR): Title 47, Part 2, Subpart J: Equipment Authorization
     Procedures
   ™ US Code of Federal Regulations (CFR): Title 47, Part 15, Subpart C: Radio Frequency Devices,
     Intentional Radiators
   ™ FCC OET Bulletin 65 Appendix C - Evaluating Compliance with FCC Guidelines for Human
     Exposure to Radiofrequency Electromagnetic Fields
ACS Report: 06-0013-15C                Advanced Compliance Solutions                         Page 6


  Model:   C3A1L                                                           FCC ID: SK9C3A-1L


  4.0 LIST OF TEST EQUIPMENT
  All test equipment used for regulatory testing is calibrated yearly or according to manufacturer’s
  specifications.
                                    Table 4.0-1: Test Equipment
                                  Equipment Calibration Information
ACS#                  Mfg.                Eq. type             Model               S/N         Cal. Due
25          Chase                    Bi-Log Antenna       CBL6111           1043                5/23/06
268         Agilent                  Sensor               N1921A            MY45240184          10/10/06
152         EMCO                     LISN                 3825/2            9111-1905           1/18/06
                                                          9408-50-R-24-
NA          Solar                    LISN                                   018821              12/22/06
                                                          BNC
                                     Conducted EMI
165         ACS                                           RG8               165                 1/06/06
                                     Cable Set
22          Agilent                  Pre-Amplifier        8449B             3008A00526          5/06/06
73          Agilent                  Pre-Amplifier        8447D             272A05624           5/18/06
30          Spectrum Technologies    Horn Antenna         DRH-0118          970102              5/09/06
105         Microwave Circuits       High Pass Filter     H1G810G1          2123-01 DC0225      9/13/06
1           Rohde & Schwarz          Receiver Display     804.8932.52       833771/007          3/07/06
2           Rohde & Schwarz          ESMI Receiver        1032.5640.53      839587/003          3/07/06
3           Rohde & Schwarz          Receiver Display     804.8932.52       839379/011         11/02/06
4           Rohde & Schwarz          ESMI Receiver        1032.5640.53      833827/003         11/02/06
---         Agilent                  Spectrum Analyzer    E7405A            US39110103           6/6/06
213         Test Equipment Corp.     Pre-Amplifier        PA-102            44927               12/5/06
168         Hewlett Packard          Pulse Limiter        11947A            3107A02268           3/2/06
204         ACS                      Cable                RG8               204                 3/16/06
6           Harbour Industries       HF RF Cable          LL-335            00006               3/16/06
7           Harbour Industries       HF RF Cable          LL-335            00007               3/16/06
208         Harbour Industries       HF RF Cable          LL142             00208               6/24/06
                                     Chamber EMI
167         ACS                                           RG6               167                  1/7/07
                                     Cable Set
237         Gigatronics              Signal Generator     900               282706              1/10/07
267        Agilent                  Power Meter          N1911A            MY45100129          10/30/06




  ACS Report: 06-0013-15C              Advanced Compliance Solutions                      Page 7


Model:    C3A1L                                                                FCC ID: SK9C3A-1L


5.0 SUPPORT EQUIPMENT

                                 Table 5-3: Support Equipment
 Manufacturer       Equipment Type     Model Number      Serial Number              FCC ID

                                     EUT Was Self Supporting



6.0 EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM




                                                           Spectrum Analyzer




                                  Connection to a
                                  Spectrum Analyzer used
                                  for conducted
                                  measurements only




                                  120/240/480 VAC                                   120/240/480 VAC
         Configuration 1                                   Configuration 2




                                     Figure 6-1: EUT Test Setup


Configuration 1: Used for radiated emissions and AC power line conducted emissions.
Configuration 2: Used for RF conducted measurements. The EUT was configured with a 50 Ohm
temporary RF output port for conducted measurements to facilitate a direct connection to a spectrum
analyzer.

Note: The radio module can be installed in 120-480V auto ranging meter base, 120V meter base, or
240V meter base. Testing performed on all meter bases for AC power line conducted emissions
and radiated emissions.




ACS Report: 06-0013-15C                Advanced Compliance Solutions                         Page 8


Model:   C3A1L                                                                FCC ID: SK9C3A-1L


7.0 SUMMARY OF TESTS
Along with the tabular data shown below, plots were taken of all signals deemed important enough to
document.

7.1 Antenna Requirement - FCC Section 15.203
The IMAGE circuit board uses a slot antenna design. The slot is set in length for the quarter wavelength
of 915 MHz which can not be altered without destroying the device. This device meets the requirements
of CFR 47 Part 15.203. The antenna gain is 3.5dBi.

7.2 Power Line Conducted Emissions - FCC Section 15.207

7.2.1 Test Methodology
ANSI C63.4 sections 6 and 7 were the guiding documents for this evaluation. Conducted emissions were
performed from 150kHz to 30MHz with the spectrum analyzer’s resolution bandwidth set to 9kHz and the
video bandwidth set to 30kHz. The calculation for the conducted emissions is as follows:

Corrected Reading = Analyzer Reading + LISN Loss + Cable Loss
Margin = Applicable Limit - Corrected Reading

7.2.2 Test Results
Results of the test are shown below in and Tables 7.2-1 through 7.2-16 and Figure 7.2-1 through 7.2-8.
The Polyphase meter base is auto ranging from 120VAC to 480VAC therefore data was collected at both
voltage extremes to show compliance.

120V Monophase Configuration:

                      Table 7.2-1: Line 1 Conducted EMI Results (Quasi-Peak)
   Frequency           Level       Transducer        Limit         Margin          Line          PE
      MHz              dBµV            dB            dBµV            dB
     0.246              43.6           9.7            61.8          18.2            L1          GND
     0.396              25.0           9.7            57.9          32.8            L1          GND
     0.492              43.9           9.7            56.1          12.2            L1          GND
     0.738              50.7           9.7            56.0          5.2             L1          GND
     0.978              35.0           9.7            56.0          20.9            L1          GND
     1.224              31.8           9.7            56.0          24.1            L1          GND
     1.470              29.9           9.7            56.0          26.0            L1          GND
     1.962              22.4           9.7            56.0          33.5            L1          GND
     4.194              21.6           9.6            56.0          34.3            L1          GND

                       Table 7.2-2: Line 1 Conducted EMI Results (Average)
   Frequency           Level       Transducer        Limit         Margin          Line          PE
      MHz              dBµV            dB            dBµV            dB
     0.246              35.2           9.7            51.8          16.6            L1          GND
     0.378              14.4           9.7            48.3          33.9            L1          GND
     0.492              36.1           9.7            46.1          9.9             L1          GND
     0.738              35.4           9.7            46.0          10.5            L1          GND
     0.978              27.9           9.7            46.0          18.0            L1          GND
     1.224              27.0           9.7            46.0          18.9            L1          GND
     1.470              24.6           9.7            46.0          21.3            L1          GND
     1.962              18.5           9.7            46.0          27.4            L1          GND
     4.194              21.0           9.6            46.0          24.9            L1          GND



ACS Report: 06-0013-15C                Advanced Compliance Solutions                         Page 9


Model:   C3A1L                                                                                              FCC ID: SK9C3A-1L


                  Table 7.2-3: Line 2 Conducted EMI Results (Quasi-Peak)
   Frequency       Level                 Transducer                         Limit                Margin        Line        PE
      MHz          dBµV                      dB                             dBµV                   dB
     0.246          50.0                     9.7                             61.8                 11.8          L2        GND
     0.462          29.5                     9.7                             56.6                 27.1          L2        GND
     0.492          44.6                     9.7                             56.1                 11.4          L2        GND
     0.732          49.7                     9.7                             56.0                 6.2           L2        GND
     0.978          36.9                     9.7                             56.0                 19.0          L2        GND
     1.218          30.6                     9.7                             56.0                 25.4          L2        GND
     1.230          23.8                     9.7                             56.0                 32.1          L2        GND
     1.464          30.6                     9.7                             56.0                 25.4          L2        GND
     1.956          26.3                     9.7                             56.0                 29.6          L2        GND
     4.194          21.8                     9.6                             56.0                 34.1          L2        GND

                    Table 7.2-4: Line 2 Conducted EMI Results (Average)
   Frequency       Level                 Transducer                         Limit                Margin        Line        PE
      MHz          dBµV                      dB                             dBµV                   dB
     0.246          36.0                     9.7                             51.8                 15.8          L2        GND
     0.408          14.1                     9.7                             47.6                 33.5          L2        GND
     0.492          34.6                     9.7                             46.1                 11.5          L2        GND
     0.732          38.1                     9.7                             46.0                 7.8           L2        GND
     0.978          29.2                     9.7                             46.0                 16.7          L2        GND
     1.218          26.4                     9.7                             46.0                 19.5          L2        GND
     1.230          14.1                     9.7                             46.0                 31.8          L2        GND
     1.464          27.4                     9.7                             46.0                 18.6          L2        GND
     1.956          23.8                     9.7                             46.0                 22.1          L2        GND
     4.194          21.1                     9.6                             46.0                 24.8          L2        GND

                          Level [dBµV]
                      80


                      70


                      60


                      50                               x

                                     x           x
                      40
                                     +           +     +   x
                                                               x
                      30                                           x
                                                           +   +
                                            x                      +
                                                                       x          x+
                      20                                               +
                                            +
                      10


                          0
                              150k   300k       500k       1M         2M     3M        5M   7M 10M    30M
                                                           Frequency [Hz]

                      x       MES 06-0013CE01_fin QP
                      +       MES 06-0013CE01_fin AV
                              MES 06-0013CE01_pre PK
                              LIM FCC QP Class B
                              LIM FCC AV Class B


                     Figure 7.2-1: Conducted Emissions Graph – Line 1




ACS Report: 06-0013-15C                              Advanced Compliance Solutions                                      Page 10


Model:   C3A1L                                                                                                FCC ID: SK9C3A-1L


                      Level [dBµV]
                   80


                   70


                   60


                   50            x                       x
                                                    x
                   40
                                                         +   x
                                 +                  +
                   30                           x            +   x   x
                                                                 +   +   x
                                                                 x       +
                                                                                      x
                                                                                      +
                   20
                                            +                    +
                   10


                      0
                          150k       300k   500k             1M          2M    3M         5M   7M   10M      30M
                                                             Frequency [Hz]

                  x       MES 06-0013CE02_fin QP
                  +       MES 06-0013CE02_fin AV
                          MES 06-0013CE02_pre PK
                          LIM FCC QP Class B
                          LIM FCC AV Class B


                          Figure 7.2-2: Conducted Emissions Graph – Line 2

240V Monophase Configuration:

                  Table 7.2-5: Line 1 Conducted EMI Results (Quasi-Peak)

   Frequency          Level                 Transducer                        Limit                 Margin         Line      PE
      MHz             dBµV                      dB                            dBµV                    dB
     0.252             40.6                     9.7                            61.6                  21.0          L1       GND
     0.330             32.0                     9.7                            59.4                  27.3          L1       GND
     0.498             34.7                     9.7                            56.0                  21.2          L1       GND
     0.588             29.9                     9.7                            56.0                  26.0          L1       GND
     0.750             32.8                     9.7                            56.0                  23.1          L1       GND
     1.458             24.0                     9.7                            56.0                  31.9          L1       GND
     1.806             24.0                     9.7                            56.0                  31.9          L1       GND
     4.194             30.5                     9.6                            56.0                  25.4          L1       GND
     16.776            30.1                     9.3                            60.0                  29.8          L1       GND
     25.164            32.2                     8.8                            60.0                  27.7          L1       GND

                      Table 7.2-6: Line 1 Conducted EMI Results (Average)
   Frequency          Level                 Transducer                        Limit                 Margin         Line      PE
      MHz             dBµV                      dB                            dBµV                    dB
     0.246             33.9                     9.7                            51.8                  17.9          L1       GND
     0.330             26.9                     9.7                            49.4                  22.4          L1       GND
     0.492             31.3                     9.7                            46.1                  14.8          L1       GND
     0.576             23.4                     9.7                            46.0                  22.5          L1       GND
     0.738             26.6                     9.7                            46.0                  19.3          L1       GND
     1.458             20.6                     9.7                            46.0                  25.3          L1       GND
     1.800             19.6                     9.7                            46.0                  26.3          L1       GND
     4.194             30.4                     9.6                            46.0                  15.5          L1       GND
     16.776            30.1                     9.3                            50.0                  19.9          L1       GND
     25.164            32.2                     8.8                            50.0                  17.7          L1       GND



ACS Report: 06-0013-15C                                 Advanced Compliance Solutions                                     Page 11


Model:   C3A1L                                                                                                    FCC ID: SK9C3A-1L


                  Table 7.2-7: Line 2 Conducted EMI Results (Quasi-Peak)
   Frequency       Level                   Transducer                       Limit                  Margin            Line        PE
      MHz          dBµV                        dB                           dBµV                     dB
     0.246          37.9                       9.7                           61.8                   23.9              L2        GND
     0.330          31.8                       9.7                           59.4                   27.6              L2        GND
     0.648          31.6                       9.7                           56.0                   24.3              L2        GND
     0.738          39.3                       9.7                           56.0                   16.6              L2        GND
     1.224          21.4                       9.7                           56.0                   34.5              L2        GND
     1.470          17.0                       9.7                           56.0                   38.9              L2        GND
     4.194          30.3                       9.6                           56.0                   25.6              L2        GND
     16.776         30.6                       9.3                           60.0                   29.3              L2        GND
     25.164         31.2                       8.8                           60.0                   28.7              L2        GND


                    Table 7.2-8: Line 2 Conducted EMI Results (Average)
   Frequency       Level                   Transducer                       Limit                  Margin            Line        PE
      MHz          dBµV                        dB                           dBµV                     dB
     0.246          33.9                       9.7                           51.8                   17.9              L2        GND
     0.330          26.2                       9.7                           49.4                   23.2              L2        GND
     0.648          26.0                       9.7                           46.0                   19.9              L2        GND
     0.732          25.5                       9.7                           46.0                   20.4              L2        GND
     1.224          19.0                       9.7                           46.0                   26.9              L2        GND
     1.470          13.7                       9.7                           46.0                   32.2              L2        GND
     4.194          30.2                       9.6                           46.0                   15.7              L2        GND
     16.776         30.6                       9.3                           50.0                   19.3              L2        GND
     25.164         31.2                       8.8                           50.0                   18.7              L2        GND

                        Level [dBµV]
                    80


                    70


                    60


                    50


                    40             x

                                   +         x
                                       x     + x       x                                                    +
                                                                                                            x
                    30                                                              x
                                                                                    +                   +
                                                                                                        x
                                       +               +
                                                   +             x   x
                    20                                           +   +


                    10


                        0
                            150k   300k     500k           1M         2M     3M         5M   7M   10M       30M
                                                           Frequency [Hz]

                    x       MES 06-0013CE05_fin QP
                    +       MES 06-0013CE05_fin AV
                            MES 06-0013CE05_pre PK
                            LIM FCC QP Class B
                            LIM FCC AV Class B


                        Figure 7.2-3: Conducted Emissions Graph – Line 1




ACS Report: 06-0013-15C                            Advanced Compliance Solutions                                              Page 12


Model:   C3A1L                                                                                                       FCC ID: SK9C3A-1L


                         Level [dBµV]
                     80


                     70


                     60


                     50


                     40                                 x
                                    x
                                    +
                                        x           x                                x+                   x+   x+
                     30
                                        +           + +
                     20                                         x
                                                                +
                                                                    x
                                                                    +
                     10


                         0
                             150k   300k     500k           1M         2M     3M          5M   7M   10M        30M
                                                            Frequency [Hz]

                     x       MES 06-0013CE06_fin QP
                     +       MES 06-0013CE06_fin AV
                             MES 06-0013CE06_pre PK
                             LIM FCC QP Class B
                             LIM FCC AV Class B


                         Figure 7.2-4: Conducted Emissions Graph – Line 2



120V Polyphase Configuration:

                   Table 7.2-9: Line 1 Conducted EMI Results (Quasi-Peak)
   Frequency        Level                   Transducer                       Limit                   Margin             Line        PE
      MHz           dBµV                        dB                           dBµV                      dB
     0.156           41.7                       9.8                           65.6                    23.9               L1        GND
     0.276           46.3                       9.7                           60.9                    14.6               L1        GND
     0.414           44.0                       9.7                           57.5                    13.4               L1        GND
     0.546           41.9                       9.7                           56.0                    14.0               L1        GND
      0.69           38.0                       9.7                           56.0                    17.9               L1        GND
     1.242           35.5                       9.7                           56.0                    20.4               L1        GND
     1.374           33.3                       9.7                           56.0                    22.6               L1        GND
     2.508           28.6                       9.6                           56.0                    27.3               L1        GND
     4.176           28.1                       9.6                           56.0                    27.8               L1        GND

                    Table 7.2-10: Line 1 Conducted EMI Results (Average)
   Frequency        Level                   Transducer                       Limit                   Margin             Line        PE
      MHz           dBµV                        dB                           dBµV                      dB
      0.15           31.6                       9.8                           56.0                    24.3               L1        GND
      0.27           35.7                       9.7                           51.1                    15.3               L1        GND
     0.276           35.5                       9.7                           50.9                    15.4               L1        GND
     0.408           32.8                       9.7                           47.6                    14.8               L1        GND
     0.552           32.6                       9.7                           46.0                    13.3               L1        GND
      0.69           29.1                       9.7                           46.0                    16.9               L1        GND
     1.236           26.0                       9.7                           46.0                    19.9               L1        GND
     1.368           25.2                       9.7                           46.0                    20.7               L1        GND
      2.46           21.0                       9.6                           46.0                    25.0               L1        GND
     4.158           20.0                       9.6                           46.0                    25.9               L1        GND




ACS Report: 06-0013-15C                             Advanced Compliance Solutions                                                Page 13


Model:   C3A1L                                                                                                 FCC ID: SK9C3A-1L


                  Table 7.2-11: Line 2 Conducted EMI Results (Quasi-Peak)
   Frequency       Level                     Transducer                      Limit                  Margin        Line        PE
      MHz          dBµV                          dB                          dBµV                     dB
     0.276          44.8                         9.7                          60.9                   16.0          L2        GND
     0.414          40.0                         9.7                          57.5                   17.5          L2        GND
     0.552          36.6                         9.7                          56.0                   19.3          L2        GND
      0.96          25.6                         9.7                          56.0                   30.3          L2        GND
     1.104          26.6                         9.7                          56.0                   29.3          L2        GND
     1.938          23.0                         9.7                          56.0                   32.9          L2        GND
     3.522          23.3                         9.6                          56.0                   32.6          L2        GND
     4.158          24.7                         9.6                          56.0                   31.2          L2        GND


                   Table 7.2-12: Line 2 Conducted EMI Results (Average)
   Frequency       Level                     Transducer                      Limit                  Margin        Line        PE
      MHz          dBµV                          dB                          dBµV                     dB
     0.276          31.8                         9.7                          50.9                   19.0          L2        GND
     0.414          27.8                         9.7                          47.5                   19.7          L2        GND
     0.552          25.5                         9.7                          46.0                   20.4          L2        GND
     0.918          16.4                         9.7                          46.0                   29.5          L2        GND
     1.086          14.9                         9.7                          46.0                   31.0          L2        GND
     1.914          13.8                         9.7                          46.0                   32.1          L2        GND
      3.6           14.7                         9.6                          46.0                   31.2          L2        GND
     4.182          16.7                         9.6                          46.0                   29.2          L2        GND


                          Level [dBµV]
                      80


                      70


                      60


                      50
                                        x
                                               x
                              x                    x
                      40
                                                       x
                                        ++                      x
                                               +   +                x
                              +
                      30                               +                     x        x
                                                                ++
                      20                                                     +        +


                      10


                          0
                              150k      300k   500k         1M         2M        3M       5M   7M 10M    30M
                                                            Frequency [Hz]

                      x           MES 06-0013CE003_fin QP
                      +           MES 06-0013CE003_fin AV
                                  MES 06-0013CE003_pre PK
                                  LIM FCC QP Class B
                                  LIM FCC AV Class B


                     Figure 7.2-5: Conducted Emissions Graph – Line 1




ACS Report: 06-0013-15C                            Advanced Compliance Solutions                                           Page 14


Model:   C3A1L                                                                                               FCC ID: SK9C3A-1L


                           Level [dBµV]
                       80


                       70


                       60


                       50
                                      x
                       40                    x
                                                 x
                                      +
                       30
                                             +
                                                 +       x x
                                                                    x           x x
                       20
                                                         + +                        +
                                                                   +            +
                       10


                           0
                               150k   300k   500k        1M         2M     3M           5M   7M 10M    30M
                                                         Frequency [Hz]

                       x       MES 06-0013CE004_fin QP
                       +       MES 06-0013CE004_fin AV
                               MES 06-0013CE004_pre PK
                               LIM FCC QP Class B
                               LIM FCC AV Class B


                      Figure 7.2-6: Conducted Emissions Graph – Line 2


480V Polyphase Configuration:

                   Table 7.2-13: Line 1 Conducted EMI Results (Quasi-Peak)
   Frequency        Level                 Transducer                      Limit                   Margin        Line        PE
      MHz           dBµV                      dB                          dBµV                      dB
     0.156           44.4                     9.8                          65.6                    21.2          L1        GND
     0.282           42.6                     9.7                          60.7                     18           L1        GND
      0.69            43                      9.7                           56                     12.9          L1        GND
     0.834           41.8                     9.7                           56                     14.1          L1        GND
      1.35           37.7                     9.7                           56                     18.2          L1        GND
     2.856           34.5                     9.6                           56                     21.4          L1        GND
      4.65           31.1                     9.7                           56                     24.8          L1        GND
     6.558           27.1                     9.5                           60                     32.8          L1        GND
     8.046           24.5                     9.6                           60                     35.5          L1        GND
     9.342           21.7                     9.6                           60                     38.2          L1        GND

                    Table 7.2-14: Line 1 Conducted EMI Results (Average)
   Frequency        Level                 Transducer                      Limit                   Margin        Line        PE
      MHz           dBµV                      dB                          dBµV                      dB
      0.15           33.6                     9.8                           56                     22.3          L1        GND
     0.294           30.4                     9.7                          50.4                    19.9          L1        GND
     0.678           35.4                     9.7                           46                     10.5          L1        GND
     0.834           33.6                     9.7                           46                     12.3          L1        GND
      1.35           29.6                     9.7                           46                     16.3          L1        GND
     2.868            27                      9.6                           46                     18.9          L1        GND
     4.668           23.6                     9.7                           46                     22.3          L1        GND
     6.576           19.6                     9.5                           50                     30.3          L1        GND
     8.016           17.3                     9.6                           50                     32.6          L1        GND
     9.378           15.2                     9.6                           50                     34.7          L1        GND



ACS Report: 06-0013-15C                          Advanced Compliance Solutions                                           Page 15


Model:   C3A1L                                                                                                      FCC ID: SK9C3A-1L


                  Table 7.2-15: Line 2 Conducted EMI Results (Quasi-Peak)
   Frequency       Level                     Transducer                         Limit                    Margin        Line        PE
      MHz          dBµV                          dB                             dBµV                       dB
     0.162          43.9                         9.8                             65.3                     21.4          L2        GND
     0.288          40.7                         9.7                             60.5                     19.8          L2        GND
     0.558          35.8                         9.7                              56                      20.1          L2        GND
      1.08          33.7                         9.7                              56                      22.2          L2        GND
     1.356          29.2                         9.7                              56                      26.7          L2        GND
     2.898          28.4                         9.6                              56                      27.5          L2        GND
      4.65          27.4                         9.7                              56                      28.6          L2        GND
     6.384          26.1                         9.5                              60                      33.8          L2        GND
     8.034          24.3                         9.6                              60                      35.7          L2        GND
     9.294          18.3                         9.6                              60                      41.6          L2        GND


                   Table 7.2-16: Line 2 Conducted EMI Results (Average)
   Frequency       Level                     Transducer                         Limit                    Margin        Line        PE
      MHz          dBµV                          dB                             dBµV                       dB
      0.15          31.5                         9.8                              56                      24.4          L2        GND
      0.3            26                          9.7                             50.2                     24.2          L2        GND
     0.558          25.1                         9.7                              46                      20.8          L2        GND
     1.086          23.8                         9.7                              46                      22.1          L2        GND
     1.368          19.8                         9.7                              46                      26.1          L2        GND
     2.922          20.6                         9.6                              46                      25.3          L2        GND
     4.626          20.3                         9.7                              46                      25.6          L2        GND
     6.366          18.7                         9.5                              50                      31.2          L2        GND
     7.986           17                          9.6                              50                      32.9          L2        GND
     9.312          12.6                         9.6                              50                      37.3          L2        GND

                          Level [dBµV]
                      80


                      70


                      60


                      50
                              x                       x x
                                         x
                      40
                                                                    x
                                                      +                          x
                              +                            +
                      30                 +                                              x
                                                                    +
                                                                                 +           x
                                                                                        +        x
                                                                                                     x
                      20                                                                     +
                                                                                                 +
                                                                                                     +
                      10


                          0
                              150k      300k   500k            1M         2M     3M     5M   7M 10M           30M
                                                               Frequency [Hz]

                      x           MES 06-0012CE07_fin QP
                      +           MES 06-0012CE07_fin AV
                                  MES 06-0012CE07_pre PK
                                  LIM FCC QP Class B
                                  LIM FCC AV Class B


                     Figure 7.2-7: Conducted Emissions Graph – Line 1




ACS Report: 06-0013-15C                          Advanced Compliance Solutions                                                  Page 16


Model:    C3A1L                                                                                                  FCC ID: SK9C3A-1L


                               Level [dBµV]
                           80


                           70


                           60


                           50

                                   x
                           40                 x
                                                     x
                                                                x
                           30 +                                     x         x      x
                                              +      +                                    x
                                                                +                             x
                           20                                       +         +      +
                                                                                          +
                                                                                              + x
                                                                                                +
                           10


                               0
                                   150k   300k    500k      1M         2M     3M     5M   7M 10M           30M
                                                            Frequency [Hz]

                           x       MES 06-0012CE08_fin QP
                           +       MES 06-0012CE08_fin AV
                                   MES 06-0012CE08_pre PK
                                   LIM FCC QP Class B
                                   LIM FCC AV Class B


                          Figure 7.2-8: Conducted Emissions Graph – Line 2

7.3 Radiated Emissions - FCC Section 15.109(Unintentional Radiation)

7.3.1 Test Methodology
Radiated emissions tests were performed over the frequency range of 30MHz to 1 GHz. Measurements
of the radiated field strength were made at a distance of 3m from the boundary of the equipment under
test (EUT) and the receiving antenna. The antenna height was varied from 1m to 4m so that the
maximum radiated emissions level would be detected. Radiated measurements were made with the
Spectrum Analyzer’s resolution bandwidth set to 120 KHz for measurements above 30MHz. Average
measurements are taken with the RBW and VBW were set to 1MHz and 10 Hz respectively for
measurements above 1000MHz.

7.3.2 Test Results
Results of the test are given in Table 7.3-1 below:

                           Table 7.3-1: Radiated Emissions Tabulated Data

     Frequency        Polarization                   Height             Azimuth                   Level           Limit     Margin
         (MHz)                                           (cm)                (deg)            (dBµV/m)           (dBµV/m)    (dB)

        MHz         VERTICAL                             105                 211                    28.4           40.0      11.6
       55.84        VERTICAL                             110                 332                    26.1           40.0      13.9
       60.72        VERTICAL                             170                 322                    41.5           43.5       2.0
       95.12        HORIZONTAL                           190                  86                    28.5           43.5      15.0
       151.04       HORIZONTAL                           100                 274                    13.4           46.0      32.6
       336.56       HORIZONTAL                           190                 197                    15.9           46.0      30.1
       405.52       VERTICAL                             150                  9                     32.4           46.0      13.6
       645.12       VERTICAL                             110                 167                    18.3           46.0      27.7
       650.08       HORIZONTAL                           105                  1                     31.7           46.0      14.3
       663.52       HORIZONTAL                           298                  75                    24.6           46.0      21.4

* Note: All emissions above 663.52 MHz were attenuated below the permissible limit.




ACS Report: 06-0013-15C                             Advanced Compliance Solutions                                            Page 17


Model:   C3A1L                                                                         FCC ID: SK9C3A-1L


7.4 Peak Output Power – FCC Section 15.247(b)(2)

7.4.1 Test Methodology (Conducted Method)
The 20dB bandwidth of the EUT was within the resolution bandwidth of spectrum analyzer, therefore the
power measurement was made using the spectrum analyzer method. The resolution and video
bandwidth were set to > 20 dB bandwidth of the emission measured. The device employs >50 channels
therefore the power is limited to 1 Watt.

7.4.2 Test Results
Results are shown below in table 7.4-1 and the worst case was plotted and shown in figure 7.4-1 to 7.4-3
below:

                                          Table 7.4-1: RF Output Power
                                        Frequency                 Level
                                          [MHz]                  [dBm]
                                         909.506                  13.25
                                         916.040                  12.62
                                         921.773                  12.15


                                                                             Mkr1 909.506 MHz
                    Ref 20 dBm                 Atten 30 dB                          13.25 dBm
                    Peak                                         1

                    Log
                    10
                    dB/




                    M1 S2
                    S3 FC
                       AA




                    Center 909.6 MHz                                                Span 2 MHz
                    #Res BW 1 MHz                            VBW 1 MHz    Sweep 5 ms (401 pts)




                                 Figure 7.4-1: Output power – Low Channel

                                                                             Mkr1 916.040 MHz
                    Ref 20 dBm                #Atten 30 dB                          12.62 dBm
                    Peak                                             1
                    Log
                    10
                    dB/




                    M1 S2
                    S3 FC
                       AA




                    Center 916 MHz                                                  Span 2 MHz
                    #Res BW 1 MHz                            VBW 1 MHz    Sweep 5 ms (401 pts)



                                     Figure 7.4-2: Output power – Mid Channel

ACS Report: 06-0013-15C                       Advanced Compliance Solutions                        Page 18


Model:   C3A1L                                                                  FCC ID: SK9C3A-1L




                                                                      Mkr1 921.773 MHz
                   Ref 20 dBm             Atten 30 dB                       12.15 dBm
                   Peak                                    1
                   Log
                   10
                   dB/




                   V1 S2
                   S3 FC
                      AA




                   Center 921.7 MHz                                         Span 2 MHz
                   #Res BW 1 MHz                    VBW 1 MHz      Sweep 5 ms (401 pts)



                                Figure 7.4-3: Output power – High Channel


7.5 Channel Usage Requirements - FCC Section 15.247(a) (1)

15.247(a)(1): Frequency hopping systems shall have hopping channel carrier frequencies separated by a
minimum of 25 kHz or the 20 dB bandwidth of the hopping channel, whichever is greater. The system
shall hop to channel frequencies that are selected at the system hopping rate from a pseudo randomly
ordered list of hopping frequencies. Each frequency must be used equally on the average by each
transmitter. The system receivers shall have input bandwidths that match the hopping channel
bandwidths of their corresponding transmitters and shall shift frequencies in synchronization with the
transmitted signals.

15.247(a) (1) (i): For frequency hopping systems operating in the 902–928 MHz band: if the 20 dB
bandwidth of the hopping channel is less than 250 kHz, the system shall use at least 50 hopping
frequencies and the average time of occupancy on any frequency shall not be greater than 0.4 seconds
within a 20 second period; if the 20 dB bandwidth of the hopping channel is 250 kHz or greater, the
system shall use at least 25 hopping frequencies and the average time of occupancy on any frequency
shall not be greater than 0.4 seconds within a 10 second period. The maximum allowed 20 dB bandwidth
of the hopping channel is 500 kHz.




ACS Report: 06-0013-15C                  Advanced Compliance Solutions                      Page 19


Model:   C3A1L                                                           FCC ID: SK9C3A-1L


7.5.1 Carrier Frequency Separation

7.5.1.1 Test Methodology
The span of the spectrum analyzer was set wide enough to capture two adjacent peaks and the RBW
and VBW were set to ≥ 1% of the span.

7.5.1.2 Test Results
The maximum 20dB bandwidth of the hopping channel was measured to be 114.5 kHz (See figure 7.5.4-
1 to 7.5.4-3 below). The adjacent channel separation was measured to be 196.2 kHz. Results are
shown in figure 7.5.1-1 below:




                          Figure 7.5.1-1: Carrier Frequency Separation

7.5.2 Number of Hopping Channels
The 20dB bandwidth of the device is less than 250 kHz. The device employs 50 hopping channels as
required. Results are shown in Figure 7.5.2-1 below:




                          Figure 7.5.2-1: Number of Hopping Channels


ACS Report: 06-0013-15C              Advanced Compliance Solutions                     Page 20


Model:   C3A1L                                                                  FCC ID: SK9C3A-1L


7.5.3 Channel Dwell Time

The worse case with regards to RF dwell time on C3A1H that can occur is when the SCM burst of
messages and IDM message happen to occur back to back on the same channel. This will give you a
worst case dwell time of 115.23 msec with is the combined transmission times of the two message types.
This dwell time is less than 400 msec and this channel would not be transmitted upon until 50 channel
hops later. With transmission rates set to 30 sec, this means that this channel would not be used until 25
minutes later. This is obviously less than 20 sec and hence the RF dwell time meets the less than 400
msec within a 20 sec criteria.

A more detailed description of dwell time can be found attached to the Theory of Operations.




ACS Report: 06-0013-15C                 Advanced Compliance Solutions                          Page 21


Model:   C3A1L                                                                      FCC ID: SK9C3A-1L


7.5.4 20dB Bandwidth

7.5.4.1 Test Methodology
The spectrum analyzer span was set to 2 to 3 times the estimated 20 dB bandwidth of the emission. The
RBW was to ≥ 1% of the estimated 20 dB bandwidth. The trace was set to max hold with a peak detector
active. The span and RBW were examined and re-adjusted if necessary to meet the requirements of 2 to
3 time the 20 bandwidth for the span and ≥ 1% of the 20 dB bandwidth for the RBW.

7.5.4.2 Test Results
The maximum 20dB bandwidth was found to be approximately 114.5 kHz. Results are shown below in
Table 7.5.4-1and Figures 7.5.4-1 through 7.5.4-3.


                                      Table 7.5.4-1: 20dB Bandwidth
                     Channel                Frequency         20dB Bandwidth
                                               (MHz)                (kHz)
                        Low                    909.6                110.0
                        Mid                    916.0                114.0
                        High                   921.8                114.5


                                                                           Mkr1 ∆ 110.0 kHz
                   Ref 20 dBm                Atten 30 dB                          0.052 dB
                   Peak
                   Log
                   10
                   dB/
                                        1R                             1




                   V1 S2
                   S3 FC
                      AA




                   Center 909.6 MHz                                           Span 200 kHz
                   #Res BW 10 kHz                      VBW 10 kHz   Sweep 8.5 ms (401 pts)



                                Figure 7.5.4-1: 20dB Bandwidth Low Channel




ACS Report: 06-0013-15C                      Advanced Compliance Solutions                      Page 22


Model:   C3A1L                                                                    FCC ID: SK9C3A-1L



                                                                         Mkr1 ∆ 114.0 kHz
                 Ref 20 dBm               #Atten 30 dB                         -0.448 dB
                 Peak
                 Log
                 10
                 dB/
                                     1R                               1




                 M1 S2
                 S3 FC
                    AA




                 Center 916 MHz                                             Span 200 kHz
                 #Res BW 10 kHz                      VBW 10 kHz   Sweep 8.5 ms (401 pts)



                              Figure 7.5.4-2: 20dB Bandwidth Mid Channel


                                                                         Mkr1 ∆ 114.5 kHz
                 Ref 20 dBm               Atten 30 dB                            0.54 dB
                 Peak
                 Log
                 10
                 dB/
                                    1R                               1




                 M1 S2
                 S3 FC
                    AA




                 Center 921.8 MHz                                           Span 200 kHz
                 #Res BW 10 kHz                      VBW 10 kHz   Sweep 8.5 ms (401 pts)



                           Figure 7.5.4-3: 20dB Bandwidth High Channel




ACS Report: 06-0013-15C                   Advanced Compliance Solutions                       Page 23


Model:   C3A1L                                                                   FCC ID: SK9C3A-1L


7.6 Band-Edge Compliance and Spurious Emissions - FCC Section 15.247(c)

7.6.1 Band-Edge Compliance of RF Conducted Emissions

7.6.1.1 Test Methodology
The EUT was investigated at the lowest and highest channel available to determine band-edge
compliance. For each measurement the spectrum analyzer’s RBW was set to 100 kHz, which is ≥ 1% of
the span.

7.6.1.2 Test Results
In a 100 kHz bandwidth at the lower and upper band-edge, the radio frequency power that was produced
by the EUT is at least 20 dB below that in the 100 kHz bandwidth within the band that contains the
highest level of desired power. Band-edge compliance is displayed in Figures 7.6.1-1 and 7.6.2-2


                                                                        Mkr1 ∆ 7.575 MHz
                   Ref 20 dBm             Atten 30 dB                           64.51 dB
                   Peak                                                      1

                   Log
                   10
                   dB/




                   M1 S2
                                1R
                   S3 FC
                      AA




                   Start 901 MHz                                          Stop 911 MHz
                   #Res BW 100 kHz                 VBW 100 kHz     Sweep 4 ms (401 pts)



                                     Figure 7.6.1-1: Lower Band-edge


                                                                       Mkr1 ∆ -6.250 MHz
                   Ref 20 dBm            #Atten 30 dB                           64.16 dB
                   Peak              1
                   Log
                   10
                   dB/




                   V1 S2
                                                                       1R
                   S3 FC
                      AA




                   Start 920 MHz                                          Stop 930 MHz
                   #Res BW 100 kHz                 VBW 100 kHz     Sweep 4 ms (401 pts)



                                     Figure 7.6.1-2: Upper Band-edge



ACS Report: 06-0013-15C                  Advanced Compliance Solutions                       Page 24


Model:   C3A1L                                                                      FCC ID: SK9C3A-1L


7.6.2 RF Conducted Spurious Emissions

7.6.2.1 Test Methodology
The EUT was investigated for conducted spurious emissions from 30MHz to 10GHz, 10 times the highest
fundamental frequency. Measurements were made at the low, center and high channels of the EUT. For
each measurement, the spectrum analyzer’s VBW was set to 100kHz and the RBW was set to 100kHz.
A peak detector function was used with the trace set to max hold.

7.6.2.1 Test Results
All emission found were greater than 20dB down from the fundamental carrier. The RF conducted
spurious emissions were measured in the band of 30MHz to 10GHz. Results are shown below in Figure
7.6.2-1 through 7.6.2-6.


                                                                            Mkr1 711.4 MHz
                   Ref 20 dBm            Atten 30 dB                           -44.12 dBm
                   Peak
                   Log
                   10
                   dB/




                   Dl
                   -7.0
                   dBm

                                                                 1
                   V1 S2
                   S3 FC
                      AA




                   Start 30 MHz                                                 Stop 1 GHz
                   #Res BW 100 kHz                 VBW 100 kHz       Sweep 125 ms (401 pts)



                 Figure 7.6.2-1 RF Conducted Spurious Emissions – Low Channel


                                                                           Mkr1 3.1150 GHz
                   Ref 20 dBm            #Atten 40 dB                          -42.04 dBm
                   Peak
                   Log
                   10
                   dB/




                   Dl
                   -7.0
                   dBm

                                     1

                   V1 S2
                   S3 FC
                      AA




                   Start 1 GHz                                                 Stop 10 GHz
                   #Res BW 100 kHz                 VBW 100 kHz       Sweep 1.16 s (401 pts)



                 Figure 7.6.2-2 RF Conducted Spurious Emissions – Low Channel




ACS Report: 06-0013-15C                  Advanced Compliance Solutions                          Page 25


Model:   C3A1L                                                                                  FCC ID: SK9C3A-1L



                                                                                        Mkr1 658.1 MHz
                   Ref 20 dBm                #Atten 30 dB                                  -43.36 dBm
                   Peak
                   Log
                   10
                   dB/




                   Dl
                   -7.4
                   dBm

                                                                          1

                   M1 S2
                   S3 FC
                      AA




                   Start 30 MHz                                                             Stop 1 GHz
                   #Res BW 100 kHz                          VBW 100 kHz       #Sweep 125 ms (401 pts)



                 Figure 7.6.2-3 RF Conducted Spurious Emissions – Mid Channel


                                                                                       Mkr1 3.0250 GHz
                   Ref 20 dBm                 Atten 30 dB                                   -35.46 dBm
                   Peak
                   Log
                   10
                   dB/




                   Dl
                   -7.5
                   dBm
                                         1




                   M1 S2
                   S3 FC
                      AA




                   Start 1 GHz                                                              Stop 10 GHz
                   Res BW 1 MHz                             VBW 3 MHz         Sweep 23.59 ms (401 pts)



                 Figure 7.6.2-4 RF Conducted Spurious Emissions – Mid Channel


                                                                                        Mkr1 202.2 MHz
                   Ref 20 dBm                 Atten 30 dB                                  -41.65 dBm
                   Peak
                   Log
                   10
                   dB/




                   Dl
                   -7.9
                   dBm

                                     1

                   M1 S2
                   S3 FC
                      AA




                   Start 30 MHz                                                             Stop 1 GHz
                   #Res BW 100 kHz                          VBW 100 kHz       #Sweep 125 ms (401 pts)



                 Figure 7.6.2-5 RF Conducted Spurious Emissions – High Channel

ACS Report: 06-0013-15C                      Advanced Compliance Solutions                                  Page 26


Model:   C3A1L                                                                      FCC ID: SK9C3A-1L




                                                                           Mkr1 1.8550 GHz
                    Ref 15 dBm          #Atten 40 dB                           -42.37 dBm
                    Peak
                    Log
                    10
                    dB/




                    Dl
                    -7.9
                    dBm
                                 1



                    V1 S2
                    S3 FC
                       AA




                    Start 1 GHz                                                Stop 10 GHz
                    #Res BW 100 kHz               VBW 100 kHz        Sweep 1.16 s (401 pts)



                 Figure 7.6.2-6 RF Conducted Spurious Emissions – High Channel


7.6.3 Radiated Spurious Emissions (Restricted Bands) - FCC Section 15.205

7.6.3.1 Test Methodology
Radiated emissions tests were made over the frequency range of 30MHz to 10GHz, 10 times the highest
fundamental frequency.

The EUT was rotated through 360° and the receive antenna height was varied from 1m to 4m so that the
maximum radiated emissions level would be detected. For frequencies below 1000MHz, quasi-peak
measurements were made using a resolution bandwidth (RBW) of 120 kHz and a video bandwidth (VBW)
of 300 kHz. For frequencies above 1000MHz, average measurements were made using an RBW of 1
MHz and a VBW of 10 Hz and peak measurements were made with RBW of 1 MHz and a VBW of 1
MHz.

The EUT was caused to generate a continuous carrier signal on the hopping channel.

7.6.3.2 Duty Cycle Correction
For average radiated measurements, the measured level was reduced by a factor 6.9dB to account for
the duty cycle of the EUT. Referencing the dwell time justification in section 7.5.3 above the worst case
duty cycle within 100ms is 45% or 45ms for the IDM message type. The duty cycle correction factor is
determined using the formula: 20log (0.45)=-6.9dB.

The more detailed justification of duty cycle can be found in the dwell time justification attached to the
Theory of Operations.




ACS Report: 06-0013-15C                 Advanced Compliance Solutions                           Page 27


Model:   C3A1L                                                                              FCC ID: SK9C3A-1L


7.6.3.3 Test Results
Radiated spurious emissions found in the band of 30MHz to 10GHz are reported in Table 7.6.3-1.
through 7.6.3-3. Each emission found to be in a restricted band as defined by section 15.205, was
compared to the radiated emission limits as defined in section 15.209.

           Table 7.6.3-1: Radiated Spurious Emissions – Monophase 120V Meter Base
         Frequency     Level     (dBuV) Antenna     Correction Corrected Level        Limit         Margin
                                        Polarity     Factors        (dBuV/m)        (dBuV/m)         (dB)
           (MHz)         pk        avg   (H/V)         (dB)       pk       avg      pk     avg    pk      avg
                                                   Spurious Emissions - Low Channel
             2728.77     49.95    49.95    H           2.31     52.26     45.33     74      54   21.74   8.67
             2728.77     50.86    50.86    V           2.31     53.17     46.24     74      54   20.83   7.76
             4547.95     45.33    45.33    H           7.81     53.14     46.20     74      54   20.86   7.80
             4547.95     44.14    44.14    V           7.81     51.95     45.01     74      54   22.05   8.99
                                                   Spurious Emissions - Mid Channel
            2748.021     48.66    48.66    H           2.38     51.04     44.10     74      54   22.96   9.90
            2748.021     50.43    50.43    V           2.38     52.81     45.87     74      54   21.19   8.13
                                                   Spurious Emissions - High Channel
            2765.319     52.52    52.52    H           2.43     54.95     48.02     74      54   19.05   5.98
            2765.319     49.95    49.95    V           2.43     52.38     45.45     74      54   21.62   8.55
* The magnitude of all emissions not reported were below the noise floor of the measurement system.

           Table 7.6.3-2: Radiated Spurious Emissions – Monophase 240V Meter Base
         Frequency     Level     (dBuV) Antenna     Correction   Corrected Level       Limit         Margin
                                        Polarity     Factors        (dBuV/m)         (dBuV/m)         (dB)
           (MHz)         pk        avg   (H/V)         (dB)        pk        avg     pk   avg      pk      avg
                                                    Spurious Emissions - Low Channel
             2728.77     50.59    50.59     H          2.31      52.90      45.97    74    54    21.10    8.03
             2728.77     50.43    50.43     V          2.31      52.74      45.81    74    54    21.26    8.19
             3638.36     43.15    43.15     H          5.79      48.94      42.00    74    54    25.06   12.00
             4547.95     44.97    44.97     H          7.81      52.78      45.84    74    54    21.22    8.16
             4547.95     44.69    44.69     V          7.81      52.50      45.56    74    54    21.50    8.44
                                                    Spurious Emissions - Mid Channel
            2748.021     52.36    52.36     H          2.38      54.74      47.80    74    54    19.26    6.20
            2748.021     48.66    48.66     V          2.38      51.04      44.10    74    54    22.96    9.90
            4580.035     43.86    43.86     H          7.95      51.81      44.87    74    54    22.19    9.13
            4580.035     42.56    42.56     V          7.95      50.51      43.57    74    54    23.49   10.43
                                                    Spurious Emissions - High Channel
            2765.319     54.70    54.70     H          2.43      57.13      50.20    74    54    16.87    3.80
            2765.319     52.01    52.01     V          2.43      54.44      47.51    74    54    19.56    6.49
            3687.092     42.66    42.66     H          5.97      48.63      41.69    74    54    25.37   12.31
            3687.092     42.84    42.84     V          5.97      48.81      41.87    74    54    25.19   12.13
            4608.865     44.08    44.08     H          8.07      52.15      45.22    74    54    21.85    8.78
            4608.865     43.37    43.37     V          8.07      51.44      44.51    74    54    22.56    9.49
* The magnitude of all emissions not reported were below the noise floor of the measurement system.




ACS Report: 06-0013-15C                         Advanced Compliance Solutions                                   Page 28


Model:       C3A1L                                                                           FCC ID: SK9C3A-1L


                  Table 7.6.3-3: Radiated Spurious Emissions –Polyphase Meter Base
             Frequency     Level     (dBuV) Antenna    Correction   Corrected Level       Limit       Margin
                                            Polarity     Factors       (dBuV/m)        (dBuV/m)        (dB)
               (MHz)         pk        avg   (H/V)        (dB)        pk        avg     pk   avg    pk      avg
                                                       Spurious Emissions - Low Channel
                2728.758     51.37    51.37    H          2.31      53.68      46.75    74    54   20.32   7.25
                2728.758     54.04    54.04    V          2.31      56.35      49.42    74    54   17.65   4.58
                3638.344     45.38    45.38    H          5.79      51.17      44.23    74    54   22.83   9.77
                3638.344     45.00    45.00    V          5.79      50.79      43.85    74    54   23.21   10.15
                 4547.93     50.18    50.18    H          7.81      57.99      51.05    74    54   16.01   2.95
                 4547.93     50.46    50.46    V          7.81      58.27      51.33    74    54   15.73   2.67
                                                       Spurious Emissions - Mid Channel
                2748.021     54.45    54.45    H          2.38      56.83      49.89    74    54   17.17   4.11
                2748.021     53.10    53.10    V          2.38      55.48      48.54    74    54   18.52   5.46
                4580.035     48.33    48.33    H          7.95      56.28      49.34    74    54   17.72   4.66
                4580.035     49.21    49.21    V          7.95      57.16      50.22    74    54   16.84   3.78
                                                       Spurious Emissions - High Channel
                2765.319     55.72    55.72    H          2.43      58.15      51.22    74    54   15.85   2.78
                2765.319     54.45    54.45    V          2.43      56.88      49.95    74    54   17.12   4.05
                4608.865     48.45    48.45    H          8.07      56.52      49.59    74    54   17.48   4.41
                4608.865     50.41    50.41    V          8.07      58.48      51.55    74    54   15.52   2.45
* The magnitude of all emissions not reported were below the noise floor of the measurement system.


7.6.3.3 Sample Calculation:

RC = RU + CFT

Where:
CFT      =         Total Correction Factor (AF+CA+AG)-DC (Average Measurements Only)
RU       =         Uncorrected Reading
RC       =         Corrected Level
AF       =         Antenna Factor
CA       =         Cable Attenuation
AG       =         Amplifier Gain
DC       =         Duty Cycle Correction Factor

Example Calculation

PEAK:
Corrected Level: 49.95 + 2.31 = 52.26 dBuV
Margin: 74dBuV – 52.26 dBuV = 21.74 dB

AVERAGE:
Corrected Level: 49.95 + 2.31 -6.92 = 45.34 dBuV
Margin: 54dBuV – 45.34 dBuV = 8.66 dB

8.0 CONCLUSION
In the opinion of ACS, Inc. the C3A1L, manufactured by Itron Electricity Metering Inc., meets the
requirements of FCC Part 15 subpart C.




ACS Report: 06-0013-15C                         Advanced Compliance Solutions                                     Page 29



Document Created: 2006-03-09 09:16:24
Document Modified: 2006-03-09 09:16:24

© 2024 FCC.report