RF EXPOSURE

FCC ID: SK9C3A-1H

RF Exposure Info

Download: PDF
FCCID_640397

                 FCC Part 15.247
              Transmitter Certification
Frequency Hopping Spread Spectrum Transmitter

                           Test Report
                       FCC ID: SK9C3A-1H

                      FCC Rule Part: 15.247

           ACS Report Number: 06-0012-15C

       Manufacturer: Itron Electricity Metering Inc.
          Trade name: CENTRON® IMAGE
                    Model: C3A1H




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: C3A1H                        Advanced Compliance Solutions                          FCC ID: SK9C3A-1H




General Information:

Applicant:               Itron Electricity Metering Inc.
ACS Project:             06-0012
FCC ID:                  SK9C3A-1H
Device Category:         Mobile
Environment:             General Population/Uncontrolled Exposure

Technical Information:

Antenna Type: PCB Slot
Antenna Gain: 3.5dBi
Transmitter Conducted Power: 21.36dBm
Maximum System EIRP: 24.86dBm
Operating Configuration: Mobile (Module)
Exposure Conditions: Greater than 20 centimeters

MPE Calculation

The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:

S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                               MPE Calculator for Mobile Equipment
                      Limits for General Population/Uncontrolled Exposure*
 Transmit      Radio         Power        Radio    Antenna Antenna                         Power
                                                                      Distance
Frequency      Power Density Limit        Power      Gain      Gain                        Density
                                                                        (cm)
  (MHz)        (dBm)      (mW/Cm2)        (mW)       (dBi)   (mW eq.)                    (mW/cm^2)
   909.6        21.36         0.61        136.77      3.5      2.239     20                 0.061

Installation Guidelines
The installation manual contains the following text advising how to install the equipment to maintain
compliance with the FCC RF exposure requirements:

“RF Exposure (Intentional Radiators Only)
In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element
shall be installed such that a minimum separation distance of 20cm is maintained from the general
population.”

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




                 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598



Document Created: 2006-02-10 15:41:45
Document Modified: 2006-02-10 15:41:45

© 2024 FCC.report