RF EXPOSURE

FCC ID: SK9C1A-3

RF Exposure Info

Download: PDF
FCCID_529905

           FCC Part 15.247 Certification
                  Test Report

                          FCC ID: SK9C1A-3

                        FCC Rule Part: 15.247

             ACS Report Number: 05-0122-15C

      Manufacturer: Itron Electricity Metering, Inc.
Equipment Type: Electricity Meter With FHSS Transmitter
          Trade Name: CENTRON ™ ICARe
                     Model: C1A-3


            RF Exposure Information




  5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: C1A-3                          Advanced Compliance Solutions                           FCC ID: SK9C1A-3


General Information:

Applicant:               Itron Electricity Metering, Inc.
ACS Project:             05-0122
FCC ID:                  SK9C1A-3
Device Category:         Fixed Mount
Environment:             General Population/Uncontrolled Exposure

Technical Information:

Antenna Type: Patch
Antenna Gain: 0dBi
Transmitter Conducted Power: 21.67 dBm
Maximum System EIRP: 21.67dBm
Operating Configuration: Mounted on side of residential or commercial structure
Exposure Conditions: Greater than 20 centimeters

MPE Calculation

The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:

S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                MPE Calculator for Mobile Equipment
                       Limits for General Population/Uncontrolled Exposure*

Transmit      Radio          Power           Radio       Antenna      Antenna
                                                                                                   Power
  Freq.       Power         Density          Power        Gain          Gain        Distance
                                                                                                   Density
 (MHz)        (dBm)          Limit           (mW)         (dBi)       (mW eq.)        (cm)
                                                                                                 (mW/cm^2)
                           (mW/Cm2)

909.5861       21.67           0.61         146.893          0           1.00         20.00          0.0292


Installation Guidelines
The installation manual contains the following text advising how to install the equipment to maintain
compliance with the FCC RF exposure requirements:

“RF Exposure (Intentional Radiators Only)
This equipment complies with the FCC RF radiation requirements for uncontrolled environments. To
maintain compliance with these requirements, the antenna and any radiating elements should be installed
to ensure that a minimum separation distance of 20 cm is maintained from the general population.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.