RF EXPOSURE

FCC ID: SK9AMI-1

RF Exposure Info

Download: PDF
FCCID_712482

                  FCC Part 15.247/15.249
                  Transmitter Certification
                           Composite Device


                               Test Report
                            FCC ID: SK9AMI-1

                    FCC Rule Part: 15.247/15.249

ACS Report Number: 06-0239-15C-DSS, 06-0239-15C-DXX

           Manufacturer: Itron Electricity Metering Inc.
             Trade Name: CENTRON Open Way
              Model(s): CVSO, CVSOD, CVSOC




                             RF Exposure




    5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: CVSO, CVSOD, CVSOC                      Advanced Compliance Solutions                   FCC ID: SK9AMI-1


General Information:
Applicant:                  Itron Electricity Metering Inc.
ACS Project:                06-0239
FCC ID:                     SK9AMI-1
Device Category:            Mobile
Environment:                General Population/Uncontrolled Exposure
Exposure Conditions:        Greater than 20 centimeters

Technical Information:

Radio                          900 MHz LAN              2.4GHz Zigbee           GPRS Modem Module
Antenna Type                 single-band patch          single-band slot          dual-band patch
                                                                                   GSM850: 0dBi
Antenna Gain                         3dBi                     4dBi
                                                                                  GSM1900: 3dBi
                                                                                   GSM850: 32.4dBm
Conducted Power                 19.40dBm                    -3.0dBm
                                                                                   GSM1900: 29.8dBm
                                                                                     GSM850: 1.737W
Maximum EIRP                        0.174W                  0.001W
                                                                                      GSM1900: 1.9W

MPE Calculation:
       Calculated Conducted Power (15.249) – 2.4GHz Zigbee Radio
       For the purpose of determining Power Density for the 2.4GHz Zigbee radio the conducted RF
       power must first be calculated.

       The power was calculated using the following equation:

        P = (E ∗ d )
                       2

                           30 ∗ G
       Where: G = Numeric Gain of the transmitting antenna with reference to an isotropic radiator
              d = The distance in meters from which the field strength was measured
              E = The measured maximum fundamental field strength in V/m

                               Table 1: Maximum Fundamental Field Strength
                                Uncorrected                                               Corrected
               Frequency                           Antenna           Total Correction
                                  Reading                                                  Reading
                 (MHz)                           Polarity (H/V)        Factor (dB)
                                 (dBµV/m)                                                 (dBµV/m)
                   2405             96.36               V                  -0.12           96.24

                                            Table 2: Peak Output Power
         Frequency         Numeric Gain         Distance          Max. Fund. Field      Output Power
           (MHz)                                   (m)             Strength (V/m)          (dBm)
            2405               2.52                 3                  0.06                -2.99




               5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: CVSO, CVSOD, CVSOC                   Advanced Compliance Solutions                   FCC ID: SK9AMI-1


        Power Density
        The Power Density (mW/cm2) is calculated as follows:

              PG
        S=
             4πR 2
        Where:
        S = power density (in appropriate units, e.g. mW/cm2)
        P = power input to the antenna (in appropriate units, e.g., mW)
        G = power gain of the antenna in the direction of interest relative to an isotropic radiator
        R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                  MPE Calculator for Mobile Equipment
                         Limits for General Population/Uncontrolled Exposure*
  Transmit      Radio          Power         Radio     Antenna Antenna
                                                                          Distance Power Density
 Frequency      Power      Density Limit     Power      Gain     Gain (mW
                                                                            (cm)    (mW/cm^2)
   (MHz)        (dBm)       (mW/Cm2)         (mW)       (dBi)       eq.)
   902.25        21.36          0.60         136.77       3.5      2.239      20      0.061
    2405           -3           1.00          0.50         4       2.512      20      0.000
    824           32.4          0.55        1737.80        0       1.000      20      0.346
    1850           30           1.00        1000.00        3       1.995      20      0.397

        Summation of Power Densities – Simultaneous Transmissions
        This device contains multiple transmitters which can operate simultaneously and therefore the
        maximum RF exposure is determined by the summation of power densities. The maximum
        power density as calculated by a summation of power densities for each transmitter is as follows:

        GPRS Modem Operating in the 800MHz Cellular Band:

        900MHz LAN:              0.061 (mW/cm^2)
        2.4GHz Zigbee:           0.000 (mW/cm^2)
        GSM 850 (GPRS):          0.346 (mW/cm^2)
        TOTAL:                   0.407 (mW/cm^2)

        GPRS Modem Operating in the 1900MHz PCS Band:

        900MHz LAN:              0.061 (mW/cm^2)
        2.4GHz Zigbee:           0.000 (mW/cm^2)
        GSM 1900 (GPRS):         0.397 (mW/cm^2)
        TOTAL:                   0.458 (mW/cm^2)


Installation Guidelines:
The installation manual contains the following text advising how to install the equipment to maintain
compliance with the FCC RF exposure requirements:

“RF Exposure (Intentional Radiators Only)
In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element
shall be installed such that a minimum separation distance of 20cm is maintained from the general
population.”

Conclusion:
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.