DXX REPORT

FCC ID: SIP-5616-C

Test Report

Download: PDF
FCCID_4413511

                                                   TEST REPORT
Report No. ...................................... :       CHTEW19080071           Report Verification :

Project No……………………………:                                    SHT1907088602EW

FCC ID ............................................. :    SIP-5616-C

Applicant’s name ........................... :            MegaGain International Ltd.

Address ............................................. :   Rm 904-905, Greenfield Tower, Concordia Plaza,1 Science
                                                          Museum Road, T.S.T. East. Kowloon. HongKong

Manufacturer....................................:         MegaGain International Ltd.

Address ............................................. :   Rm 904-905, Greenfield Tower, Concordia Plaza,1 Science
                                                          Museum Road, T.S.T. East. Kowloon. HongKong

Test item description .................... :              CARS MCQUEEN BTR H20

Trade Mark ....................................... :      Disney

Model/Type reference ....................... :            5616-C

Listed Model(s) ................................. :       -

Standard ......................................... :      FCC CFR Title 47 Part 15 Subpart C Section 15.249

Date of receipt of test sample……….:                       Aug.01, 2019

Date of testing………………………...:                              Aug.01, 2019- Aug.13, 2019

Date of issue…………………………..:                                Aug.14, 2019

Result .................. …………………...:                     PASS

Compiled by
( position+printedname+signature) ... :                   File administrators Fanghui Zhu

Supervised by
(position+printedname+signature) .... :                   Project Engineer Hans Hu

Approved by
(position+printedname+signature) .... :                   RF Manager Hans Hu



Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
                                                          Tianliao, Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
The test report merely correspond to the test sample.

                                                                 Page: 1 of 28


Report No : CHTEW19080071                     Page 2 of 28                      Issued: 2019-08-14




                                              Contents

1.      TEST STANDARDS AND REPORT VERSION                                                           3

1.1.    Test Standards                                                                          3
1.2.    Report version information                                                              3

2.      TEST DESCRIPTION                                                                            4

3.      SUMMARY                                                                                     5

3.1.    Client Information                                                                      5
3.2.    Product Description                                                                     5
3.3.    EUT operation mode                                                                      5
3.4.    EUT configuration                                                                       6
3.5.    Modifications                                                                           6

4.      TEST ENVIRONMENT                                                                            7

4.1.    Address of the test laboratory                                                          7
4.2.    Test Facility                                                                           7
4.3.    Environmental conditions                                                                8
4.4.    Statement of the measurement uncertainty                                                8
4.5.    Equipments Used during the Test                                                         9

5.      TEST CONDITIONS AND RESULTS                                                             11

5.1.    Antenna requirement                                                                     11
5.2.    AC Power Conducted Emissions                                                            12
5.3.    20 dB Occupied Bandwidth                                                                13
5.4.    Radiated field strength of the fundamental signal                                       15
5.5.    Radiated Spurious Emissions and Bandedge Emission                                       17

6.      TEST SETUP PHOTOS OF THE EUT                                                            23

7.      EXTERNAL AND INTERNAL PHOTOS OF THE EUT                                                 24




Shenzhen Huatongwei International Inspection Co., Ltd.       Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                         Page 3 of 28                         Issued: 2019-08-14



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
FCC Rules Part 15.249: Operation within the bands 902-928 MHz, 2400-2483.5 MHz, 5725-5875 MHz, and
24.0-24.25 GHz.
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2019-08-14                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                      Page 4 of 28                            Issued: 2019-08-14



2. TEST DESCRIPTION
               Test Item                        Section in CFR 47             Result       Test Engineer
          Antenna requirement                         15.203                   PASS       Jiongsheng Feng
 AC Power Line Conducted Emissions                    15.207                    N/A             N/A
       20dB Occupied Bandwidth                    15.215/15.249                PASS       Jiongsheng Feng
Field strength of the Fundamental signal             15.249(a)                 PASS       Jiongsheng Feng
          Spurious Emissions                     15.209/15.249(a)              PASS           Pan Xie
         Band edge Emissions                     15.205/15.249(d)              PASS           Pan Xie

Remark: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                       Page 5 of 28                           Issued: 2019-08-14



3. SUMMARY
3.1. Client Information
Applicant:                   MegaGain International Ltd.

                             Rm 904-905, Greenfield Tower, Concordia Plaza,1 Science Museum Road,
Address:
                             T.S.T. East. Kowloon. HongKong

Manufacturer:                MegaGain International Ltd.

                             Rm 904-905, Greenfield Tower, Concordia Plaza,1 Science Museum Road,
Address:
                             T.S.T. East. Kowloon. HongKong

3.2. Product Description
Name of EUT:                 CARS MCQUEEN BTR H20

Trade Mark:                  Disney

Model No.:                   5616-C

Listed Model(s):             -

Power supply:                DC 3.0V

Adapter information:         -

Hardware Version:            V1

Software Version:l           V1

RF Specification

Operation frequency:         2405~2475MHz

Channel number:              1MHz

Modulation Type:             GFSK

Antenna type:                Integral antenna

Antenna gain:                0dBi

3.3. EUT operation mode
   Test frequency list
    According to section 15.31(m), regards to the operating frequency range over 10 MHz, must select three
    channel which were tested. the Lowest frequency, the middle frequency, and the highest frequency of
    channel were selected to perform the test, please see the above gray bottom.
                          Channel                                        Frequency (MHz)
                             CHL                                               2405
                            CHM                                                2440
                            CHH                                                2475




Shenzhen Huatongwei International Inspection Co., Ltd.            Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                       Page 6 of 28                           Issued: 2019-08-14

   TEST MODE
     For RF test items
     The engineering test program was provided and enabled to make EUT continuous transmit.

     The EUT in each of three orthogonal axis emissions had been tested ,but only the worst case (X axis)
     data recorded in the report.

     During all testing, the product is powered by new batterys.



3.4. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:
● - supplied by the manufacturer
○ - supplied by the lab

                                             Manufacturer : /
                                                Model No. : /
                                             Manufacturer : /
                                                Model No. : /


3.5. Modifications
No modifications were implemented to meet testing criteria.




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                          Page 7 of 28                             Issued: 2019-08-14



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377A

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377A.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                       Page 8 of 28                              Issued: 2019-08-14



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba

4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors in calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report according to TR-100028-01 “Electromagnetic
compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio
equipment characteristics;Part 1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum
Matters (ERM);Uncertainties in the measurementof mobile radio equipment characteristics;Part 2” and is
documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality system according to
ISO/IEC 17025. Further more, component and process variability of devices similar to that tested may result
in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Here after the best measurement capability for Shenzhen Huatongwei is reported:


                      Test Items                           Measurement Uncertainty             Notes
Conducted Disturbance 150kHz~30MHz                                   3.02 dB                     (1)
Radiated Emissions below 1GHz                                        4.90 dB                     (1)
Radiated Emissions above 1GHz                                        4.96 dB                     (1)
Occupied Bandwidth                                                    70 Hz                      (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                         Page 9 of 28                              Issued: 2019-08-14

4.5. Equipments Used during the Test
●      Conducted Emission
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)

 ●     Shielded Room         Albatross projects        N/A             N/A        2018/09/28       2023/09/27

 ●     EMI Test Receiver           R&S                 ESCI          101247       2018/10/27       2019/10/26

 ●     Artificial Mains      SCHWARZBECK            NNLK 8121          573        2018/10/27       2019/10/26

 ●     Pulse Limiter               R&S               ESH3-Z2         100499       2018/10/27       2019/10/26

 ●     RF Connection Cable   HUBER+SUHNER             EF400            N/A        2018/11/15       2019/11/14

 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A
       Single Balanced
 ○                                 FCC            FCC-TLISN-T2-02    20371        2018/10/28       2019/10/27
       Telecom Pair ISN
       Two Balanced
 ○                                 FCC            FCC-TLISN-T4-02    20373        2018/10/28       2019/10/27
       Telecom Pairs ISN
       Four Balanced
 ○                                 FCC            FCC-TLISN-T8-02    20375        2018/10/28       2019/10/27
       Telecom Pairs ISN
 ○     V-Network                   R&S               ESH3-Z6         100211       2018/10/27       2019/10/26

 ○     V-Network                   R&S               ESH3-Z6         100210       2018/10/27       2019/10/26

 ○     2-Line V-Network            R&S               ESH3-Z5         100049       2018/10/27       2019/10/26


 ●     Radiated Emission-6th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-02          N/A        2018/09/30       2021/09/29
       Chamber
 ●     EMI Test Receiver           R&S                 ESCI          100900       2018/10/28       2019/10/27

 ●     Loop Antenna                R&S               HFH2-Z2         100020       2017/11/20       2020/11/19
       Ultra-Broadband
 ●                           SCHWARZBECK             VULB9163          546        2017/04/05       2020/04/04
       Antenna
 ●     Pre-Amplifer          SCHWARZBECK             BBV 9742          N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER              N/A             N/A        2018/09/28       2019/09/27
 ●     RF Connection Cable   HUBER+SUHNER          SUCOFLEX104      501184/4      2018/09/28       2019/09/27
 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A


 ●     Radiated emission-7th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-01          N/A        2018/09/30       2021/09/29
       Chamber
 ●     Spectrum Analyzer           R&S                FSP40          100597       2018/10/27       2019/10/26

 ●     Horn Antenna          SCHWARZBECK              9120D           1011        2017/03/27       2020/03/26

 ●     Pre-amplifier              BONN             BLWA0160-2M      1811887       2018/11/14       2019/11/13

 ●     Pre-amplifier                CD               PAP-0102        12004        2018/11/14       2019/11/13
       Broadband Pre-
 ●                           SCHWARZBECK             BBV 9718       9718-248      2019/04/26       2020/04/25
       amplifier
 ●     RF Connection Cable   HUBER+SUHNER            RE-7-FH           N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER             RE-7-FL          N/A        2018/11/15       2019/11/14

 ●     Test Software               Audix                E3             N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A

Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 10 of 28                               Issued: 2019-08-14


 ●     RF Conducted Method
                                                                               Last Cal. Date   Next Cal. Date
Used      Test Equipment     Manufacturer         Model No.       Serial No.
                                                                               (YY-MM-DD)        (YY-MM-DD)
       Signal and spectrum
 ●                               R&S               FSV40           100048       2018/10/28       2019/10/27
       Analyzer
 ●     Spectrum Analyzer        Agilent            N9020A        MY50510187     2018/09/29       2019/09/28

 ○     OSP                       R&S               OSP120          101317           N/A              N/A
       Radio communication
 ○                               R&S              CMW500          137688-Lv     2018/09/29       2019/09/28
       tester
 ○     Test software          Tonscend          JS1120-1(LTE)        N/A            N/A              N/A

 ○     Test software          Tonscend          JS1120-2(WIFI)       N/A            N/A              N/A

 ○     Test software          Tonscend        JS1120-3(WCDMA)        N/A            N/A              N/A

 ○     Test software          Tonscend         JS1120-4(GSM)         N/A            N/A              N/A




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                       Page 11 of 28                               Issued: 2019-08-14



5. TEST CONDITIONS AND RESULTS
5.1. Antenna requirement
Requirement
FCC CFR Title 47 Part 15 Subpart C Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of anantenna
that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
prohibited.

Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.

TEST RESULTS

   Passed               Not Applicable

The directional gain of the antenna less than 6 dBi, please refer to the below antenna photo.




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                      Page 12 of 28                            Issued: 2019-08-14

5.2. AC Power Conducted Emissions
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207:
                                                                      Limit (dBuV)
          Frequency range (MHz)
                                                      Quasi-peak                        Average
                  0.15-0.5                             66 to 56*                        56 to 46*
                    0.5-5                                 56                               46
                    5-30                                  60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE

1. The EUT was setup according to ANSI C63.10:2013
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 10 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 10 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                      Page 13 of 28                             Issued: 2019-08-14




5.3. 20 dB Occupied Bandwidth
Limit
Operation frequency range 2400MHz~2483.5MHz.

TEST CONFIGURATION




TEST PROCEDURE

1.    The transmitter output was connected to the spectrum analyzer through an attenuator, the path loss was
      compensated to the results for each measurement.
2.    Set to the maximum power setting and enable the EUT transmit continuously
3.    Use the following spectrum analyzer settings:
      Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
      RBW ≥ 1% of the 20 dB bandwidth, VBW ≥ RBW
      Sweep = auto, Detector function = peak, Trace = max hold
4.    Measure and record the results in the test report.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable


                                     20dB Bandwidth                    Limit
        Test Channel                                                                          Result
                                         (MHz)                        (MHz)
              CHL                         1.172                          -                     Pass
              CHM                         1.158                          -                     Pass
              CHH                         1.201                          -                     Pass




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 14 of 28                      Issued: 2019-08-14




          CHL




          CHM




          CHH




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                       Page 15 of 28                             Issued: 2019-08-14

5.4. Radiated field strength of the fundamental signal
LIMIT

                                         Field strength of fundamental         Field strength of harmonics
      Fundamental frequency
                                                (millivolts/meter)                  (microvolts/meter)
           902-928 MHz                       50 (94dBuV/m @3m)                   500 (54dBuV/m @3m)
         2400-2483.5 MHz                     50 (94dBuV/m @3m)                   500 (54dBuV/m @3m)
          5725-5875 MHz                      50 (94dBuV/m @3m)                   500 (54dBuV/m @3m)
          24.0-24.25 GHz                   250 (108dBuV/m @3m)                   2500 (68dBuV/m @3m)
Frequencies above 1000 MHz, the field strength limits are based on average limits


TEST CONFIGURATION




TEST PROCEDURE

1.    The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.    The EUT is placed on a turn table which is 1.5 meter above ground. The turn table is rotated 360 degrees
      to determine the position of the maximum emission level.
3.    The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4.    The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
      repeated for both horizontal and vertical polarization of the antenna. In order to find the maximum
      emission, all of the interface cables were manipulated according to ANSI C63.10:2013 on radiated
      measurement.
5.    The receiver set as follow:
      RBW=3MHz, VBW=3MHz Peak detector for Peak value.
      RBW=3MHz, VBW=3MHz RMS detector for Average value.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                         Page 16 of 28                               Issued: 2019-08-14

                                                       CHL
 Frequency         Reading                        Level         Limit Line                                 Test
                                  Factor[dB]                                  Margin(dB)   Polarization
   (MHz)          (dBuV/m)                      (dBuV/m)        (dBuV/m)                                   value
    2405            93.90           -2.41         91.49          114.00         22.51        Vertical      Peak
    2405            93.53           -2.41         91.12           94.00          2.88        Vertical     Average
    2405            96.22           -2.40         93.82          114.00         20.18      Horizontal      Peak
    2405            92.97           -2.40         90.57           94.00          3.43      Horizontal     Average



                                                       CHM
 Frequency         Reading                        Level         Limit Line                                 Test
                                  Factor[dB]                                  Margin(dB)   Polarization
   (MHz)          (dBuV/m)                      (dBuV/m)        (dBuV/m)                                   value
    2440            94.18           -2.29         91.89          114.00         22.11        Vertical      Peak
    2440            93.99           -2.29         91.70           94.00          2.30        Vertical     Average
    2440            91.64           -2.29         89.35           94.00          4.65      Horizontal     Average
    2440            99.28           -2.29         96.99          114.00         17.01      Horizontal      Peak



                                                       CHH
 Frequency         Reading                        Level         Limit Line                                 Test
                                  Factor[dB]                                  Margin(dB)   Polarization
   (MHz)          (dBuV/m)                      (dBuV/m)        (dBuV/m)                                   value
    2475            90.95           -2.81         88.14           94.00          5.86        Vertical     Average
    2475            97.04           -2.81         94.23          114.00         19.77        Vertical      Peak
    2475            95.44           -2.81         92.63          114.00         21.37      Horizontal      Peak
    2475            93.41           -2.81         90.60           94.00          3.40      Horizontal     Average

Remark:
1. Final Level =Receiver Read level + factor
2. Factor = Antenna Factor + Cable Loss – Preamplifier Factor




Shenzhen Huatongwei International Inspection Co., Ltd.                    Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 17 of 28                         Issued: 2019-08-14



5.5. Radiated Spurious Emissions and Bandedge Emission
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209
             Frequency                        Limit (dBuV/m @3m)                       Value
            30MHz~88MHz                                  40.00                      Quasi-peak
           88MHz~216MHz                                  43.50                      Quasi-peak
          216MHz~960MHz                                  46.00                      Quasi-peak
            960MHz~1GHz                                  54.00                      Quasi-peak
                                                         54.00                        Average
             Above 1GHz
                                                         74.00                         Peak
TEST CONFIGURATION
   9 kHz ~ 30 MHz




   30 MHz ~ 1 GHz




   Above 1 GHz




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                         Page 18 of 28                                Issued: 2019-08-14



TEST PROCEDURE
1.    The EUT was setup and tested according to ANSI C63.10:2013 requirements.
2.    The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above
      1 GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level.
3.    The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable
      height antenna tower.
4.    For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower
      (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp
      and a high pass filter are used for the test in order to get better signal level to comply with the guidelines.
5.    Set to the maximum power setting and enable the EUT transmit continuously.
6.    Use the following spectrum analyzer settings
      (1) Span shall wide enough to fully capture the emission being measured;
      (2) Below 1 GHz:
          RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, the emission measurement will be repeated
          using the quasi-peak detector and reported.
                             th
      (3) From 1 GHz to 10 harmonic:
          RBW=1MHz, VBW=3MHz Peak detector for Peak value.
          RBW=1MHz, VBW=3MHz RMS detector for Average value.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed              Not Applicable

Note:
1) Above 1GHz Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2) The emission levels of other frequencies are very lower than the limit and not show in test report.


Radiated Spurious Emissions

     9 kHz ~ 30 MHz
      The EUT was pre-scanned the frequency band (9 kHz ~ 30 MHz), found the radiated level lower than the
      limit, so don’t show on the report.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 19 of 28                              Issued: 2019-08-14


 30 MHz ~ 1 GHz
Polarization:                                            Vertical




Polarization:                                            Horizontal




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 20 of 28                               Issued: 2019-08-14

     Above 1 GHz
                                                  CHL
 Frequency       Reading                      Level      Limit Line                                    Test
                               Factor[dB]                                 Margin(dB)   Polarization
   (MHz)        (dBuV/m)                    (dBuV/m)     (dBuV/m)                                      value
    1190.937        37.18        -5.93        31.25           74.00         42.75        Vertical      Peak
    3182.562        36.29         0.75        37.04           74.00         36.96        Vertical      Peak
    4808.468        54.08         7.06        61.14           74.00         12.86        Vertical      Peak
    4808.468        44.31         7.06        51.37           54.00          2.63        Vertical     Average
    7214.281        28.69        16.00        44.69           74.00         29.31        Vertical      Peak
    1227.656        36.63        -5.76        30.87           74.00         43.13      Horizontal      Peak
    3176.687        37.66         0.72        38.38           74.00         35.62      Horizontal      Peak
    4809.937        52.63         7.06        59.69           74.00         14.31      Horizontal      Peak
    4808.468        42.72         7.06        49.78           54.00          4.22      Horizontal     Average
    7214.281        28.73        16.00        44.73           74.00         29.27      Horizontal      Peak


                                                  CHM
 Frequency       Reading                      Level      Limit Line                                    Test
                               Factor[dB]                                 Margin(dB)   Polarization
   (MHz)        (dBuV/m)                    (dBuV/m)     (dBuV/m)                                      value
    1270.250        35.99        -5.65        30.34           74.00         43.66        Vertical      Peak
    3119.406        36.87         0.42        37.29           74.00         36.71        Vertical      Peak
    4878.968        51.50         7.15        58.65           74.00         15.35        Vertical      Peak
    4877.500        43.83         7.15        50.98           54.00          3.02        Vertical     Average
    6744.281        31.56        13.35        44.91           74.00         29.09        Vertical      Peak
    1199.750        36.59        -5.83        30.76           74.00         43.24      Horizontal      Peak
    3051.843        36.97         0.11        37.08           74.00         36.92      Horizontal      Peak
    4877.500        53.59         7.15        60.74           74.00         13.26      Horizontal      Peak
    4877.500        43.55         7.15        50.70           54.00          3.30      Horizontal     Average
    6666.437        31.73        13.36        45.09           74.00         28.91      Horizontal      Peak


                                                  CHH
 Frequency       Reading                      Level      Limit Line                                    Test
                               Factor[dB]                                 Margin(dB)   Polarization
   (MHz)        (dBuV/m)                    (dBuV/m)     (dBuV/m)                                      value
    1148.343        37.59        -6.38        31.21           74.00         42.79        Vertical      Peak
    3213.406        36.45         0.68        37.13           74.00         36.87        Vertical      Peak
    4949.468        52.82         7.51        60.33           74.00         13.67        Vertical      Peak
    4949.468        44.14         7.51        51.65           54.00          2.35        Vertical     Average
    7424.312        38.97        16.38        55.35           74.00         18.65        Vertical      Peak
    7422.843        32.50        16.38        48.88           54.00          5.12        Vertical     Average
    1160.093        38.04        -6.25        31.79           74.00         42.21      Horizontal      Peak
    3198.718        36.46         0.83        37.29           74.00         36.71      Horizontal      Peak
    4949.468        52.56         7.51        60.07           74.00         13.93      Horizontal      Peak
    4949.468        41.89         7.51        49.40           54.00          4.60      Horizontal     Average
    7422.843        27.72        16.38        44.10           74.00         29.90      Horizontal      Peak




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                            Page 21 of 28                                  Issued: 2019-08-14

Remark:
1. Final Level =Receiver Read level + factor
2. Factor = Antenna Factor + Cable Loss – Preamplifier Factor
3. The peak level is lower than average limit(54dBuV/m), this data is the too weak instrument of signal is unable to test.
4. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Huatongwei International Inspection Co., Ltd.                      Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                            Page 22 of 28                                  Issued: 2019-08-14

Bandedge Emission


                                                           CHL
 Frequency          Reading                          Level         Limit Line                                      Test
                                    Factor[dB]                                    Margin(dB)     Polarization
   (MHz)           (dBuV/m)                        (dBuV/m)        (dBuV/m)                                        value
  2310.000           52.54             -2.34          50.20          74.00           23.80         Vertical        Peak
  2310.000           45.47             -2.34          43.13          54.00           10.87         Vertical      Average
  2390.000           51.98             -2.41          49.57          74.00           24.43         Vertical        Peak
  2390.000           45.79             -2.41          43.38          54.00           10.62         Vertical      Average
  2400.000           54.38             -2.53          51.85          74.00           22.15         Vertical        Peak
  2400.000           46.81             -2.53          44.28          54.00           9.72          Vertical      Average
  2310.000           52.70             -2.34          50.36          74.00           23.64        Horizontal       Peak
  2310.000           45.66             -2.34          43.32          54.00           10.68        Horizontal     Average
  2390.000           44.73             -2.41          42.32          54.00           11.68        Horizontal     Average
  2390.000           51.49             -2.41          49.08          74.00           24.92        Horizontal       Peak
  2400.000           52.19             -2.53          49.66          74.00           24.34        Horizontal       Peak
  2400.000           45.86             -2.53          43.33          54.00           10.67        Horizontal     Average

                                                          CHH
 Frequency          Reading                          Level         Limit Line                                      Test
                                    Factor[dB]                                    Margin(dB)     Polarization
   (MHz)           (dBuV/m)                        (dBuV/m)        (dBuV/m)                                        value
  2483.500           52.89             -2.15          50.74          74.00           23.26         Vertical        Peak
  2483.500           44.42             -2.15          42.27          54.00           11.73         Vertical      Average
  2500.000           44.94             -2.10          42.84          54.00           11.16         Vertical      Average
  2500.000           52.46             -2.10          50.36          74.00           23.64         Vertical        Peak
  2483.518           62.65             -2.15          60.50          74.00           13.50        Horizontal       Peak
  2483.518           47.18             -2.15          45.03          54.00           8.97         Horizontal     Average
  2500.000           52.64             -2.10          50.54          74.00           23.46        Horizontal       Peak
  2500.000           44.58             -2.10          42.48          54.00           11.52        Horizontal     Average
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The peak level is lower than average limit(54dBuV/m), this data is the too weak instrument of signal is unable to test.
3. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Huatongwei International Inspection Co., Ltd.                       Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 23 of 28                      Issued: 2019-08-14



6. TEST SETUP PHOTOS OF THE EUT

Radiated Emissions




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 24 of 28                      Issued: 2019-08-14



7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT
                                            External Photos




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 25 of 28                      Issued: 2019-08-14




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 26 of 28                      Issued: 2019-08-14




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 27 of 28                      Issued: 2019-08-14



                                            Internal Photos




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19080071                     Page 28 of 28                        Issued: 2019-08-14




                                        --------End of Report--------




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)



Document Created: 2019-08-26 16:11:12
Document Modified: 2019-08-26 16:11:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC