Test Report

FCC ID: SIP-3327-W

Test Report

Download: PDF
FCCID_3248716

                               Global United Technology Services Co., Ltd.

                                                                                   Report No.: GTS201612000129F01



                                        FCC REPORT
    Applicant:                         MegaGain International Ltd.

    Address of Applicant:              Rm 1908, Greenfield Tower, Concordia Plaza, 1 Science
                                       Museum Road, T.S.T. East. Kowloon Hong Kong China
    Equipment Under Test (EUT)

      Product Name:                    TOY STORY RC RC - ALT
      Model No.:                       1701-COL00566(3327-W)
    FCC ID:                            SIP-3327-W
    Applicable standards:              FCC CFR Title 47 Part 15 Subpart C Section 15.227:2016

    Date of sample receipt:            December 23, 2016

    Date of Test:                      December 24-27, 2016

    Date of report issued:             December 28, 2016

    Test Result :                      PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




      Robinson Lo
Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not
relate to other samples of the same product and does not permit the use of the GTS product certification mark. The
manufacturer should ensure that all products in series production are in conformity with the product sample detailed in
this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other
than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any
mention of GTS or testing done by GTS in connection with, distribution or use of the product described in this report must
be approved by GTS in writing.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 90 days only.


                                                                               Report No.: GTS201612000129F01

2      Version

           Version No.                                  Date                            Description
                 00                             December 28, 2016                         Original




Prepared By:                                                       Date:              December 28, 2016

                                     Project Engineer



Check By:                                                          Date:              December 28, 2016

                                          Reviewer




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                          Page 2 of 19


                                                                                                            Report No.: GTS201612000129F01

3         Contents
                                                                                                                                                          Page
1    COVER PAGE ............................................................................................................................................ 1

2     VERSION .................................................................................................................................................. 2

3     CONTENTS .............................................................................................................................................. 3

4     TEST SUMMARY ..................................................................................................................................... 4
    4.1       MEASUREMENT UNCERTAINTY ............................................................................................................ 4
5     GENERAL INFORMATION ...................................................................................................................... 5
    5.1       CLIENT INFORMATION ......................................................................................................................... 5
    5.2       GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.3       TEST MODE ........................................................................................................................................ 6
    5.4       DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6
    5.5       TEST FACILITY.................................................................................................................................... 6
    5.6       TEST LOCATION ................................................................................................................................. 6
    5.7       OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6
6     TEST INSTRUMENTS LIST ..................................................................................................................... 7

7     TEST RESULTS AND MEASUREMENT DATA...................................................................................... 8
    7.1       ANTENNA REQUIREMENT ..................................................................................................................... 8
    7.2       RADIATED EMISSION ........................................................................................................................... 9
    7.3       20DB OCCUPY BANDWIDTH .............................................................................................................. 15
8     TEST SETUP PHOTO ............................................................................................................................ 16

9     EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 17




Global United Technology Services Co., Ltd.                                                                         Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                                   Page 3 of 19


                                                                               Report No.: GTS201612000129F01

4      Test Summary
                 Test Item                             Section in CFR 47                      Result
          Antenna requirement                                 15.203                           Pass
    AC Power Line Conducted Emission                          15.207                            N/A
            Radiated emission                            15.227 & 15.209                       Pass
        20dB Occupied Bandwidth                             15.215 (c)                         Pass
Pass: The EUT complies with the essential requirements in the standard.
N/A: Not applicable
4.1 Measurement Uncertainty
            Test Item                      Frequency Range                Measurement Uncertainty       Notes
        Radiated Emission                     9kHz ~ 30MHz                        ± 4.34dB               (1)
        Radiated Emission                  30MHz ~ 1000MHz                        ± 4.24dB               (1)
        Radiated Emission                   1GHz ~ 26.5GHz                        ± 4.68dB               (1)
    AC Power Line Conducted
                                            0.15MHz ~ 30MHz                       ± 3.45dB               (1)
          Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 4 of 19


                                                                               Report No.: GTS201612000129F01

5      General Information
5.1 Client Information
      Applicant:                    MegaGain International Ltd.
      Address of Applicant:         Rm 1908, Greenfield Tower, Concordia Plaza, 1 Science Museum Road,
                                    T.S.T. East. Kowloon Hong Kong China
      Factory:                      Ya Lian industrial Co, Ltd.
      Address of Factory:           Xiechang Road, Caole Village, Xiegang Town, Dongguan, Guangdong,
                                    China
5.2 General Description of EUT
      Product Name:                 TOY STORY RC RC - ALT
      Model No.:                    1701-COL00566(3327-W)
      Operation Frequency:          27.145MHz
      Modulation type:              AM
      Antenna Type:                 Integral antenna
      Antenna gain:                 0dBi (declare by Applicant)
      Power supply:                 DC 3V 2*1.5AAA




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 5 of 19


                                                                               Report No.: GTS201612000129F01


5.3 Test mode
       Transmitting mode                    Keep the EUT in continuously transmitting mode
       Remark: During the test, the new battery was used.
5.4 Description of Support Units
     None
5.5 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● FCC —Registration No.: 600491
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fuly
      described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
      from the FCC is maintained in files. Registration 600491, June 22, 2016.
      ● Industry Canada (IC) —Registration No.: 9079A-2
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
      Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
      No.: 9079A-2, August 15, 2016.
5.6 Test Location
      All tests were performed at:
      Global United Technology Services Co., Ltd.
      No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
      Xixiang Road, Baoan District, Shenzhen, Guangdong, China
      Tel: 0755-27798480
      Fax: 0755-27798960
5.7 Other Information Requested by the Customer
      None.




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 6 of 19


                                                                                 Report No.: GTS201612000129F01

6       Test Instruments list
Radiated Emission:
                                                                               Inventory     Cal.Date       Cal.Due date
Item       Test Equipment          Manufacturer           Model No.
                                                                                  No.       (mm-dd-yy)      (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron   9.0(L)*6.0(W)* 6.0(H)      GTS250      July. 03 2015    July. 02 2020
             Chamber
 2         Control Room          ZhongYu Electron   6.2(L)*2.5(W)* 2.4(H)      GTS251          N/A              N/A
 3       Spectrum Analyzer           Agilent               E4440A              GTS533      Jun. 29 2016     Jun. 28 2017

 4       EMI Test Receiver       Rohde & Schwarz           ESU26               GTS203      Jun. 29 2016     Jun. 28 2017
 5         Loop Antenna              Zhinan              ZN30900A              GTS534      June. 29 2016    Jun. 28 2017
                                 SCHWARZBECK
 6       BiConiLog Antenna                               VULB9163              GTS214      Jun. 29 2016     Jun. 28 2017
                                MESS-ELEKTRONIK
          Double -ridged         SCHWARZBECK
 7                                                       9120D-829             GTS208      Jun. 29 2016     Jun. 28 2017
          waveguide horn        MESS-ELEKTRONIK
 8         Horn Antenna          ETS-LINDGREN               3160               GTS217      Jun. 29 2016     Jun. 28 2017
 9       EMI Test Software           AUDIX                   E3                  N/A           N/A              N/A
10         Coaxial Cable              GTS                    N/A               GTS213      Jun. 29 2016     Jun. 28 2017

11         Coaxial Cable              GTS                    N/A               GTS211      Jun. 29 2016     Jun. 28 2017

12         Coaxial cable              GTS                    N/A               GTS210      Jun. 29 2016     Jun. 28 2017

13         Coaxial Cable              GTS                    N/A               GTS212      Jun. 29 2016     Jun. 28 2017

14     Amplifier(100kHz-3GHz)          HP                   8347A              GTS204      Jun. 29 2016     Jun. 28 2017
15     Amplifier(2GHz-20GHz)           HP                   8349B              GTS206      Jun. 29 2016     Jun. 28 2017
16                                                      AFS33-18002
        Amplifier (18-26GHz)     Rohde & Schwarz                               GTS218      Jun. 29 2016     Jun. 28 2017
                                                        650-30-8P-44
17           Band filter            Amindeon                82346              GTS219      Jun. 29 2016     Jun. 28 2017




General used equipment:
                                                                               Inventory      Cal.Date       Cal.Due date
Item       Test Equipment          Manufacturer            Model No.
                                                                                  No.        (mm-dd-yy)      (mm-dd-yy)

 1           Barometer              ChangChun                DYM3               GTS257      Jun. 29 2016    Jun. 28 2017




Global United Technology Services Co., Ltd.                                             Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                Page 7 of 19


                                                                                Report No.: GTS201612000129F01

7      Test results and Measurement Data
7.1 Antenna requirement
      Standard requirement:            FCC Part15 C Section 15.203
      15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
       party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a
       unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be
       replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
      EUT Antenna:

        The antenna is integral antenna, the best case gain of the antenna is 0dBi.




Global United Technology Services Co., Ltd.                                           Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                               Page 8 of 19


                                                                               Report No.: GTS201612000129F01


7.2 Radiated Emission
      Test Requirement:                FCC Part15 C Section 15.209
      Test Method:                     ANSI C63.4:2014
      Test Frequency Range:            9kHz to 1GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                       Frequency        Detector            RBW        VBW        Value
                                          9KHz-150KHz      Quasi-peak           200Hz      600Hz     Quasi-peak
                                         150KHz-30MHz      Quasi-peak           9KHz       30KHz     Quasi-peak
                                          30MHz-1GHz       Quasi-peak          120KHz     300KHz     Quasi-peak
                                                              Peak              1MHz       3MHz        Peak
                                           Above 1GHz
                                                              Peak              1MHz        10Hz      Average
      Limit:                                    Frequency               Limit (dBuV/m @3m)          Remark
      (Field strength of the                                                     80.00           Average Value
      fundamental signal)                26.96MHz ~ 27.28MHz
                                                                                100.00            Peak Value
      Limit:                                                                                       Measurement
                                               Frequency             Limit (uV/m)       Value
      (Spurious Emissions)                                                                          Distance
                                         0.009MHz-0.490MHz         2400/F(KHz)         QP             300m
                                         0.490MHz-1.705MHz         24000/F(KHz)        QP             300m
                                          1.705MHz-30MHz                30             QP             30m
                                            30MHz-88MHz                 100            QP
                                            88MHz-216MHz                150            QP
                                           216MHz-960MHz                200            QP
                                                                                                       3m
                                             960MHz-1GHz                500            QP
                                                                        500          Average
                                             Above 1GHz
                                                                       5000           Peak
      Limit:                           Emissions radiated outside of the specified frequency bands, except for
      (band edge)                      harmonics, shall be attenuated by at least 50 dB below the level of the
                                       fundamental or to the general radiated emission limits in Section 15.209,
                                       whichever is the lesser attenuation.
      Test setup:                        Below 30MHz




                                        Below 1GHz




Global United Technology Services Co., Ltd.                                         Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                         Page 9 of 19


                                                                               Report No.: GTS201612000129F01




                                        Above 1GHz




      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                          ground at a 3 meter camber. The table was rotated 360 degrees to
                                          determine the position of the highest radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                          antenna, which was mounted on the top of a variable-height antenna
                                          tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                          ground to determine the maximum value of the field strength. Both
                                          horizontal and vertical polarizations of the antenna are set to make the
                                          measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                          and then the antenna was tuned to heights from 1 meter to 4 meters
                                          and the rota table was turned from 0 degrees to 360 degrees to find the
                                          maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                          Specified Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                          limit specified, then testing could be stopped and the peak values of the
                                          EUT would be reported. Otherwise the emissions that did not have
                                          10dB margin would be re-tested one by one using peak, quasi-peak or
                                          average method as specified and then reported in a data sheet.
                                       7. For the radiated emission test above 1GHz:
                                          Place the measurement antenna away from each area of the EUT

Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 10 of 19


                                                                              Report No.: GTS201612000129F01
                                         determined to be a source of emissions at the specified measurement
                                         distance, while keeping the measurement antenna aimed at the source
                                         of emissions at each frequency of significant emissions, with
                                         polarization oriented for maximum response. The measurement
                                         antenna may have to be higher or lower than the EUT, depending on
                                         the radiation pattern of the emission and staying aimed at the emission
                                         source for receiving the maximum signal. The final measurement
                                         antenna elevation shall be that which maximizes the emissions. The
                                         measurement antenna elevation for maximum emissions shall be
                                         restricted to a range of heights of from 1 m to 4 m above the ground or
                                         reference ground plane.
                                         For the test above 1GHz, when radiated measurements are made at
                                         the measurement distance and the measurement antenna does not
                                         completely encompass a large EUT at that distance, additional
                                         measurements at a greater distance may be necessary to demonstrate
                                         that emissions were at maximum at the limit distance.
      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.3 for details
      Test results:                    Pass




Global United Technology Services Co., Ltd.                                      Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                      Page 11 of 19


                                                                               Report No.: GTS201612000129F01

Measurement data:
Note: Limit dBuV/m @3m = Limit dBuV/m @300m+ 80
       Limit dBuV/m @3m = Limit dBuV/m @30m + 40




                          Read      Antenna                      Limit
           Frequency                         Cable      Level             Over
                          Level      Factor                      @3m               Detector
             (MHz)                          Loss (dB) (dBuV/m)          Limit (dB)
                         (dBuV)      (dB/m)                    (dBuV/m)
             26.960       24.29      22.62        0.55        47.46        69.54    -22.08      QP
             27.145       26.47      22.61        0.55        49.63        80.00    -30.37      Ave.
             27.145       34.30      22.61        0.55        57.46       100.00    -42.54     Peak
             27.280       23.24      22.61        0.55        46.40        69.54    -23.14      QP

Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 12 of 19


UG S
       B Level (dBuVim)


       70

       60
                                                                                          FCC PART15.227
       50

       w—l‘——_‘

       30

       20
                                                                                   5
                  2                             3                    4
       WWMW
            30             50                   100                  200                             1000
                                                           Frequency (MHz)
Site               :   Im chamber
Condition          : FCC PARTIS.227 3m HORIZONTAL
Job No.            : 6T5201612000129
Test Mode     : TX on mode
Test Engineer: Chen
                  Readintenna Preamp            Cable              Limit    Over
          Freq Level Factor Factor                Loss     Level    Line   Limit Remark

                 MHz    dBu¥     dB/m      dB         dB dBu¥/m dBu¥/m        dB

  1         30.317      31.43   11.30   30.10       0.§§   13.18   40.00 —26.82 QP
  2         36. T66     30.81   11.20   30.10       0.63   12.54   40.00 —27.46 QP
  3         98. 142     27.41   11.73   29.82       1.18   10.50   43.50 —33.00 QP
  4     191.745         28.28    9.70   29.44       1.80   10.34   43.50 —33.16 QP
  5     283.979         28.36   13.01   30.08       2.29   13.57   46.00 —32.43 QP
  6     549.020         28.54   18.40   29.45       3.52   21.01   46. 00 —24. 99 QP


UG S
            Level (dBuVim)


       70

       60
                                                                                                ECC PART15.227




            30            50                     100                 200                  500              1000
                                                           Frequency (MHz)
Site               : Im chamber
Condition          : FCC PARTIG.227 3m VERTICAL
Tob No.            : 6T75201612000129
Test Mode     : TK on mode
Test Engineer: Chen
                  Readintenna Preamp             Cable             Limit    Over
          Freq Level Factor Factor                 Loss   Level     Line   Limit Remark

                 MEz   dBu¥     dB/m       dB          dB dBu¥/m dBu¥/m       dB

  1      37.548        31.67   12.30    30.10     o.64     14.51   40.00 —25.49 QP
  2     102. 001       27.56   12.10    290.79     1.21    11.07   43.50 —32.43 QP
  3     189.739        27.11    9. 70   29.45     1. T9    9.15    43.50 —34. 35 QP
  4     307.831        26.76   13.68    30.15     2.40     12.69   46.00 —33.31 QP
  5§    434.065        27.42   16.17    29.56      3.02    17.05   46.00 —28.95 qP
  6     952. 094       26.49   22.50    20.25     5.04     24.78   46.00 —21.22 QP


                                                                               Report No.: GTS201612000129F01

7.3 20dB Occupy Bandwidth
      Test Requirement:                FCC Part15 C Section 15.227/15.215
      Test Method:                     ANSI C63.4:2014
      Limit:                           Operation Frequency range 26.96MHz ~ 27.28MHz
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.3 for details
      Test results:                    Pass


Measurement Data
                 20dB bandwidth(MHz)                                                 Result
                        0.016358                                                      Pass


Test plot as follows:




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 15 of 19


                                                                               Report No.: GTS201612000129F01

8      Test Setup Photo
       Radiated Emission




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 16 of 19


                                                                               Report No.: GTS201612000129F01


9      EUT Constructional Details




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 17 of 19


                                                                               Report No.: GTS201612000129F01




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 18 of 19


                                                                               Report No.: GTS201612000129F01




                                                    ------End------




Global United Technology Services Co., Ltd.                                        Project No.: GTS201612000129
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 19 of 19



Document Created: 2017-01-05 19:27:14
Document Modified: 2017-01-05 19:27:14

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC