RF Exposure

FCC ID: SDBSLC200

RF Exposure Info

Download: PDF
FCCID_1882102

                        Certification Exhibit



                            FCC ID: SDBSLC200
                             IC: 2220A-SLC200

FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C
   IC Radio Standards Specification: RSS 119, RSS 134

                    ACS Project Number: 12-2118

         Manufacturer: Sensus Metering Systems, Inc.
                       Model: SLC200




                              RF Exposure




      3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587


Model: SLC200                              FCC ID: SDBSLC200                             IC: 2220A-SLC200


General Information:
Applicant:                Sensus Metering Systems, Inc.
ACS Project:              12-2118
Device Category:          Mobile
Environment:              General Population/Uncontrolled Exposure

Technical Information:
Antenna Type:          PCB Asymmetrical Dipole Antenna
Antenna Gain:          2 dBi
Maximum Transmitter Conducted Power: 29.21 dBm, 833.68 mW
Maximum System EIRP: 31.21 dBm, 1321.3 mW
Exposure Conditions: Greater than 20 centimeters

MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                   MPE Calculator for Mobile Equipment
                          Limits for General Population/Uncontrolled Exposure*
  Transmit       Radio          Power         Radio     Antenna Antenna
                                                                           Distance Power Density
 Frequency       Power      Density Limit     Power      Gain     Gain (mW
                                                                             (cm)    (mW/cm^2)
   (MHz)         (dBm)       (mW/Cm2)         (mW)       (dBi)       eq.)
    900           29.21          0.60         833.68        2       1.585      20      0.263


Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




     ACS Project: 12-2118                 Advanced Compliance Solutions                         Page 2



Document Created: 2013-01-15 10:32:18
Document Modified: 2013-01-15 10:32:18

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC