RF Exposure

FCC ID: SDBSLC20

RF Exposure Info

Download: PDF
FCCID_1882072

                        Certification Exhibit



                             FCC ID: SDBSLC20
                              IC: 2220A-SLC20

FCC Rule Part: CFR 47 Part 24 Subpart D, Part 101 Subpart C
   IC Radio Standards Specification: RSS 119, RSS 134

                    ACS Project Number: 12-2117

         Manufacturer: Sensus Metering Systems, Inc.
                        Model: SLC20




                              RF Exposure




      3998 FAU Blvd. Suite 310 Boca Raton, FL 33431 Tel: 561-961-5585 Fax: 561-961-5587


Model: SLC20                                 FCC ID: SDBSLC20                              IC: 2220A-SLC20


General Information:
Applicant:               Sensus Metering Systems, Inc.
ACS Project:             12-2117
Device Category:         Mobile
Environment:             General Population/Uncontrolled Exposure

Technical Information:
Antenna Type:          ½ Wave Dipole Antenna
Antenna Gain:          0 dBi
Maximum Transmitter Conducted Power: 29.21 dBm, 833.68 mW
Maximum System EIRP: 29.21 dBm, 833.68 mW
Exposure Conditions: Greater than 20 centimeters

MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                MPE Calculator for Mobile Equipment
                       Limits for General Population/Uncontrolled Exposure*
  Transmit      Radio         Power        Radio    Antenna Antenna                              Power
                                                                       Distance
 Frequency      Power     Density Limit    Power      Gain      Gain                             Density
                                                                         (cm)
   (MHz)        (dBm)      (mW/Cm2)        (mW)       (dBi)   (mW eq.)                         (mW/cm^2)
     900         29.21          0.60       833.68       0       1.000     20                      0.166

Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




     ACS Project: 12-2117                 Advanced Compliance Solutions                          Page 2



Document Created: 2013-01-15 10:21:20
Document Modified: 2013-01-15 10:21:20

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC