RF Exposure

FCC ID: SDBSGW100

RF Exposure Info

Download: PDF
FCCID_2900597

                   Certification Exhibit




                      FCC ID: SDBSGW100


           FCC Rule Part: 47 CFR Part 2.1091


               ACS Project Number: 15-3018

     Manufacturer: Sensus Metering Systems, Inc.
                   Model: SGW100




                         RF Exposure




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


       Model: SGW100                                                           FCC ID: SDBSGW100


General Information:
Applicant:           Sensus Metering Systems, Inc.
Device Category:     Mobile
Environment:         General Population/Uncontrolled Exposure

Technical Information:
Antenna Type: Monopole
Antenna Gain: 2 dBi dBi
Maximum Transmitter Conducted Power: 29.51 dBm, 893.31 mW
Maximum System EIRP: 31.51 dBm, 1415.79 mW
Exposure Conditions: 20 centimeters or greater


MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                         Table 1: MPE Calculation
                             Power
  Transmit      Radio                     Radio      Antenna    Antenna                   Power
                            Density                                         Distance
 Frequency      Power                     Power       Gain        Gain                    Density
                             Limit                                            (cm)
   (MHz)        (dBm)                     (mW)        (dBi)     (mW eq.)                (mW/cm^2)
                           (mW/Cm2)
     901        29.51          0.6        893.31         2        1.585         20         0.282



Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of greater than 20 centimeters be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




     ACS Project: 15-3018                 Advanced Compliance Solutions                            Page 2



Document Created: 2017-11-17 20:56:59
Document Modified: 2017-11-17 20:56:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC