RF Exposure

FCC ID: SDBFLEXLG100

RF Exposure Info

Download: PDF
FCCID_1109329

                            Certification Exhibit



                            FCC ID: SDBFLEXLG100
                             IC: 2220A-FLEXLG100

FCC Rule Part: CFR 47 Part 24 Subpart D, Part 90 Subpart I, Part 101
                            Subpart C
      IC Radio Standards Specification: RSS 119, RSS 134

                     ACS Report Number: 08-0432-LD

                    Applicant: Sensus Metering Systems
                            Model: FLEXLG100




                                  RF Exposure




         5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: FLEXLG100                        FCC ID: SDBFLEXLG100                       IC: 2220A-FLEXLG100


General Information:
Applicant:               Sensus Metering Systems, Inc.
ACS Project:             08-0432-LD
FCC ID:                  SDBFLEXLG100
Device Category:         Mobile
Environment:             Uncontrolled/General Population


Technical Information:
Antenna Type: PCB Printed Monopole
Antenna Gain: 0dBi
Maximum Transmitter Conducted Power: 29.52dBm
Maximum System EIRP: 29.52dBm, 0.895 W

Exposure Conditions: Greater than 20 centimeters

MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4R 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                               MPE Calculator for Mobile Equipment
                       Limits for General Population/Uncontrolled Exposure
  Transmit      Radio        Power        Radio     Antenna Antenna                              Power
                                                                       Distance
 Frequency      Power Density Limit       Power      Gain      Gain                              Density
                                                                         (cm)
   (MHz)        (dBm)     (mW/Cm2)         (mW)      (dBi)   (mW eq.)                          (mW/cm^2)
  896.0625       29.52         0.60       895.36       0       1.000      20                      0.178
  928.925        29.19         0.62       829.85       0       1.000      20                      0.165
  959.925        28.94         0.64       783.43       0       1.000      20                      0.156

Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.




 ACS Report: 08-0432-LD                      Advanced Compliance Solutions                           Page 2



Document Created: 2009-05-07 13:43:39
Document Modified: 2009-05-07 13:43:39

© 2024 FCC.report