RF Exposure Report

FCC ID: SAP515238

RF Exposure Info

Download: PDF
FCCID_4236013

   Client            dormaKaba
   Product           Quantam Pixel Lock

   Standard(s)       FCC KDB 447498, RSS-102



Maximum Permissible Exposure / Specific Absorption Rate

                           EUT:                                                                   Quantam Pixel Lock
        FCC Certification #, FCC ID:                                                                         SAP515238
    Industry Canada Certification #, IC:                                                                  7078A-515238
       EUT passed all tests performed                                                                                Yes
               Tests conducted by                                                                         Scott Drysdale


This device has an effective isotropic radiated power of 59.4 (dBµV/m @ 3 meters) - 95.2 (factor to
convert to EIRP at 3 meters) of -35.8 dBm (worst case), or 263 µW at 13.56 MHz.

This device is designed to be operated at a distance exceeding 20 cm and for the purpose of
demonstrating compliance with MPE requirements and SAR exemption; we present a worst case
5mm distance and 100 % duty cycle.

As per RSS-102, Section 2.5.1, the limit for below 300 MHz is 71 mW at 5mm or less.

This device is significantly under the RSS-102 limit for 5 mm.

As per FCC KDB 447498 D01 appendix C, a worst case limit of 308 mW applies for frequencies 50
MHz at lower for distances less than 50 mm.

This device, in individual operation therefore complies with FCC requirements.




             Page 1 of 1                                 Report issue date: 3/22/2019                       File #: 7169003030MPE-00

                           This test report shall not be reproduced except in full, without written approval of TUV SUD Canada