MPE

FCC ID: S8L-100595HPRM

Test Report

Download: PDF
FCCID_762008

EUT: HRPM850                                                               FCC ID: S8L-100595HPRM
Model: RF100595/NTN065JA                                         Report Number: 0048-070116-01-FCC



Section 10. Maximum Permissible Exposure

 MPE estimate is given per 2.1091 of FCC Rules:
 Calculation Equation:

                    P +G

               10    20
 d = 0.282 ×
                    S

 Where, P--max. Output Power, G—Antenna Gain and S—Power Density Factor from §1.1310.


 Plug all three items into the equation, and yields,

  Power Density            Output     Server       Donor       Server MPE          Donor MPE
    MPE Limit              Power     Antenna      Antenna       Distance            Distance
    (mW/ cm2)              (dBm)    Gain (dBi)   Gain (dBi)       (cm)                (cm)




NOTE:

For mobile or fixed location transmitters, the minimum separation distance is
20 cm, even if calculations indicate that the MPE distance would be less.

     N/A FOR THIS CASE ----AMPLIFIER ONLY, NO ATENNNA PRESENT.




                                           Page 64 of 74
  Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288