Test Report 4

FCC ID: S5EBTV0909

Test Report

Download: PDF
FCCID_1281429

                                 TEST REPORT
                                    FROM
                           RFI GLOBAL SERVICES LTD
                                       Partial Test of: Blutag Victim


                                          To: FCC Part 15.249(a)


                                          Test Report Serial No:
                                         RFI-RPT-RP76131JD04B
                            Version 2.0 supersedes all previous versions

This Test Report Is Issued Under The Authority
Of Brian Watson, COO Payments and
Consultancy:



Checked By:                                             Nigel Davison

Signature:



                                                        pp

Date of Issue:                                          14 May 2010


This report is issued in Adobe Acrobat portable document format (PDF). It is only a valid copy of the report if
it is being viewed in PDF format with the following security options not allowed: Changing the document,
Selecting text and graphics, Adding or changing notes and form fields.
This report may not be reproduced other than in full, except with the prior written approval of RFI Global
Services Ltd. The results in this report apply only to the sample(s) tested.


TEST REPORT                                    SERIAL NO: RFI-RPT-RP76131JD04B

VERSION NO. 2.0                                        ISSUE DATE: 14 MAY 2010



This page has been left intentionally blank.




Page 2 of 11                                                 RFI Global Services Ltd


TEST REPORT                                                                                  SERIAL NO: RFI-RPT-RP76131JD04B

                                                                                                          ISSUE DATE: 14 MAY 2010




Table of Contents
1. Customer Information ..................................................................................................................4
2. Summary of Testing .....................................................................................................................5
3. Equipment Under Test (EUT) .......................................................................................................6
4. Operation and Monitoring of the EUT during Testing ...............................................................7
5. Measurements, Examinations and Derived Results ..................................................................8
6. Measurement Uncertainty ..........................................................................................................10
Appendix 1. Test Equipment Used................................................................................................11




RFI Global Services Ltd                                                                                                      Page 3 of 11


TEST REPORT                                          SERIAL NO: RFI-RPT-RP76131JD04B

VERSION NO. 2.0                                              ISSUE DATE: 14 MAY 2010




1. Customer Information
 Company Name:    Satellite Tracking of People LLC
 Address:         1212 North Post Oak Road
                  Suite 100
                  Houston
                  Texas
                  77055
                  USA




Page 4 of 11                                                       RFI Global Services Ltd


TEST REPORT                                                                 SERIAL NO: RFI-RPT-RP76131JD04B

                                                                                       ISSUE DATE: 14 MAY 2010




2. Summary of Testing
2.1. General Information
Specification Reference:           47CFR15.249
Specification Title:               Code of Federal Regulations Volume 47 (Telecommunications) 2009:
                                   Part 15 Subpart C (Radio Frequency Devices) - Section 15.249
Site Registration:                 209735
Location of Testing:               RFI Global Services Ltd, Wade Road, Basingstoke, Hampshire, RG24 8AH
Test Dates:                        18 October 2009 to 20 November 2009

2.2. Summary of Test Results
FCC Reference                      Measurement                               Port Type                Result
(47CFR)
FCC 15.249(a)                      Transmitter Fundamental Field Strength    Antenna
Key to Results

   = Complied             = Did not comply


2.3. Methods and Procedures
Reference:                         ANSI/TIA-603-C-2004
Title:                             Land Mobile FM or PM - Communications Equipment - Measurement and
                                   Performance Standards
Reference:                         ANSI C63.10 (2009)
Title:                             American National Standard Methods for Testing Unlicensed Wireless Devices

2.4. Deviations from the Test Specification

Transmitter Fundamental Field Strength requested only.




RFI Global Services Ltd                                                                             Page 5 of 11


TEST REPORT                                                          SERIAL NO: RFI-RPT-RP76131JD04B

VERSION NO. 2.0                                                              ISSUE DATE: 14 MAY 2010




3. Equipment Under Test (EUT)
3.1. Identification of Equipment Under Test (EUT)
Brand Name:                                   Blutag
Model Name or Number:                         Victim
Serial Number:                                000015
Hardware Version Number:                      BB11_V
Software Version Number:                      4_603
FCC ID Number:                                S5EBTV0909

3.2. Description of EUT

The equipment under test was a body worn GPRS/GPS tracker fitted with an ISM 915 MHz
transmitter.

3.3. Modifications Incorporated in the EUT

No modifications were applied to the EUT during testing.

3.4. Additional Information Related to Testing
Equipment Category                            ISM915 MHz
Type of Radio Device:                         Short Range Device
Antenna Type:                                 Internal
Power Supply Requirement(s):                  3.7 V

3.5. Support Equipment
The following support equipment was used to exercise the EUT during testing:

Description:                                  Wireless Communication Test Set
Brand Name:                                   Agilent
Model Name or Number:                         8960 Series 10
Serial Number:                                GB46311280
Cable Length and Type:                        ~1.5m Utiflex Cable
Connected to Port:                            RF Input/Output Port




Page 6 of 11                                                                       RFI Global Services Ltd


TEST REPORT                                                       SERIAL NO: RFI-RPT-RP76131JD04B

                                                                          ISSUE DATE: 14 MAY 2010




4. Operation and Monitoring of the EUT during Testing
4.1. Operating Modes

The EUT was tested in the following operating mode(s):
    •    ISM 915 MHz device – Constantly transmitting at maximum power

4.2. Configuration and Peripherals

The EUT was tested in the following configuration(s):
    •    The EUT was put into ISM 915 MHz mode by following the Client’s instructions. The main
         button was pressed until the Light Emitting Diodes indicated the required mode.
    •    The battery was fully charged before testing commenced and recharged as required during
         the testing.




RFI Global Services Ltd                                                                 Page 7 of 11


TEST REPORT                                                        SERIAL NO: RFI-RPT-RP76131JD04B

VERSION NO. 2.0                                                             ISSUE DATE: 14 MAY 2010




5. Measurements, Examinations and Derived Results
5.1. General Comments
Measurement uncertainties are evaluated in accordance with current best practice. Our reported
expanded uncertainties are based on standard uncertainties, which are multiplied by an
appropriate coverage factor to provide a statistical confidence level of approximately 95%. Please
refer to Section 6. Measurement Uncertainty for details.




Page 8 of 11                                                                      RFI Global Services Ltd


TEST REPORT                                                            SERIAL NO: RFI-RPT-RP76131JD04B

                                                                                ISSUE DATE: 14 MAY 2010




5.2. Test Results
5.2.1. Transmitter Fundamental Field Strength
Test Summary:

FCC Part:                                    Section 15.249(a)
Test Method Used:                            ANSI C63.10 Section 6.5

Environmental Conditions:

Temperature Range (°C):                      25
Relative Humidity Range (%):                 32

Results: ISM 915 MHz

               Channel                Measured Frequency (MHz)                  Level (dBuV/m)
            Single Channel                        915.093                             83.6

Calculated Power (ERP)

               Channel                Measured Frequency (MHz)                    Level (dBm)
            Single Channel                        915.093                             -13.8

Note(s):

1. The power result was calculated from the measured field strength using Pt = E^2R^2/30 where Pt is the
   power in Watts and R is the range distance of 3m. The final power was also reduced by 2.15 dB to
   account for the fact a dipole was used instead of an isotropic antenna.
2. The EUT was positioned in the X, Y and Z planes. The measurement antenna was positioned in the
   horizontal and vertical planes. The highest level was recorded in the above table.




RFI Global Services Ltd                                                                         Page 9 of 11


TEST REPORT                                                        SERIAL NO: RFI-RPT-RP76131JD04B

VERSION NO. 2.0                                                             ISSUE DATE: 14 MAY 2010




6. Measurement Uncertainty
No measurement or test can ever be perfect and the imperfections give rise to error of
measurement in the results. Consequently the result of a measurement is only an approximation
to the value of the measurand (the specific quantity subject to measurement) and is only complete
when accompanied by a statement of the uncertainty of the approximation.
The expression of uncertainty of a measurement result allows realistic comparison of results with
reference values and limits given in specifications and standards.
The uncertainty of the result may need to be taken into account when interpreting the
measurement results.
The reported expanded uncertainties below are based on a standard uncertainty multiplied by an
appropriate coverage factor such that a confidence level of approximately 95% is maintained. For
the purposes of this document “approximately” is interpreted as meaning “effectively” or “for most
practical purposes”.

Measurement Type                            Range                         Confidence      Calculated
                                                                          Level (%)       Uncertainty
Transmitter Fundamental Field Strength      30 MHz to 1000 MHz            95%             ±4.64 dB

The methods used to calculate the above uncertainties are in line with those recommended within
the various measurement specifications. Where measurement specifications do not include
guidelines for the evaluation of measurement uncertainty the published guidance of the appropriate
accreditation body is followed.




Page 10 of 11                                                                     RFI Global Services Ltd


TEST REPORT                                                           SERIAL NO: RFI-RPT-RP76131JD04B

                                                                                ISSUE DATE: 14 MAY 2010




Appendix 1. Test Equipment Used
                                                                                               Cal.
                                                                                 Date Last
RFI No.     Instrument             Manufacturer   Type No.     Serial No.                      Interval
                                                                                 Calibrated
                                                                                               (Months)
                                                                                 Calibrated
A1005       Waveguide Transition   Silver Lab     PM 7325X     None                            -
                                                                                 before use
                                   HUBER +                                       Calibrated
A1391       Attenuator                            757987       6810.17.B                       -
                                   SUHNER AG                                     before use
                                   HUBER +                                       Calibrated
A1392       Attenuator                            757456       6820.17.B                       -
                                   SUHNER AG                                     before use
                                   Hewlett        8449B OPT                      Calibrated
A1534       Pre Amplifier                                      3008A00405                      -
                                   Packard        H02                            before use
                                                                                 27 Nov
A1818       Antenna                EMCO           3115         00075692                        12
                                                                                 2009
                                                                                 16 Mar
A288        Antenna                Chase          CBL6111A     1589                            12
                                                                                 2010
                                   Rohde &                                       09 Mar
M1124       Spectrum Analyser                     ESIB26       100046K                         12
                                   Schwarz                                       2009
                                                  Not                            01 Sept
K0002       3m RSE Chamber         Rainford EMC                Not applicable                  12
                                                  applicable                     2009

NB In accordance with UKAS requirements all the measurement equipment is on a calibration
schedule.




RFI Global Services Ltd                                                                       Page 11 of 11



Document Created: 2010-05-14 12:07:54
Document Modified: 2010-05-14 12:07:54

© 2024 FCC.report