Test Report 1

FCC ID: S5EBTV0909

Test Report

Download: PDF
FCCID_1281426

                             TEST REPORT
                                FROM
                       RFI GLOBAL SERVICES LTD


              Test of: Satellite Tracking of People LLC, Blutag Victim Unit



                                 To: CFR47 Parts 15.207 and 15.209



                       Test Report Serial No: RFI-EMC-RP76131JD02A



                        Version 2.0 Supersedes all previous Versions


This test report is issued under the authority
of Scott D’Adamo, Operations Manager:




                                                            pp

Checked By:                                                 Steven White

Signature:


Date of Issue:                                              13 May 2010

This report is issued in portable document format (PDF). It is only a valid copy of the report if it is being viewed in
PDF format with the following security options not allowed: Changing the document, Selecting text and graphics,
Adding or changing notes and form fields.
This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services
Ltd. The results in this report apply only to the sample(s) tested.


TEST REPORT                                    SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                           ISSUE DATE: 13 MAY 2010



This page has been left intentionally blank.




Page 2 of 26                                              RFI Global Services Ltd.


TEST REPORT                                                                                SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                                          ISSUE DATE: 13 MAY 2010




                                              TABLE OF CONTENTS

1. Customer Details ..............................................................................................................5
2. Summary of Testing .........................................................................................................6
3. Equipment under Test (EUT) ...........................................................................................7
4. Support Equipment...........................................................................................................8
5. Monitoring Performance ..................................................................................................9
6. Measurement Uncertainty ..............................................................................................10
7. Measurements, Examinations and Derived Results ....................................................11
8. Photographs of EUT .......................................................................................................16
9. Graphical Test Results ...................................................................................................19
10. Test Configuration Drawing.........................................................................................25




RFI Global Services Ltd.                                                                                               Page 3 of 26


TEST REPORT                                    SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                           ISSUE DATE: 13 MAY 2010



This page has been intentionally left blank.




Page 4 of 26                                              RFI Global Services Ltd.


TEST REPORT                                                   SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                          ISSUE DATE: 13 MAY 2010




1. CUSTOMER DETAILS
Company Name:              Satellite Tracking of People LLC
Address:                   1212 North Post Oak Road
                           Suite 100
                           Houston
                           Texas
                           77055




RFI Global Services Ltd.                                                           Page 5 of 26


TEST REPORT                                                                            SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                                      ISSUE DATE: 13 MAY 2010




2. SUMMARY OF TESTING
2.1. Test Specification
Reference:                     CFR47 Parts 15.207 and 15.209


Title:                         Code of Federal Regulations Volume 47 (Telecommunications) 2008: Part 15
                               (Radio Frequency Devices) – Section 15. 207 and 15. 209
Company Registration No.       209735


2.2. Summary of Test Results
Clause         Measurement Type                                                                       Applicability    Result
                                                        EMISSIONS

15.209         Radiated Emissions (Enclosure)                                                               Y

15.207         Conducted Emissions (AC Mains Input/Output Ports)                                            Y



KEY:      = Complied         = Did not comply

2.3. Location of Testing
All the measurements described in this report were performed at the premises of RFI Global Services Ltd, Unit 3 Horizon,
Wade Road, Kingsland Business Park, Basingstoke, Hampshire, RG24 8AH.




Page 6 of 26                                                                                          RFI Global Services Ltd.


TEST REPORT                                                                              SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                                       ISSUE DATE: 13 MAY 2010




3. EQUIPMENT UNDER TEST (EUT)
3.1. Description of EUT
The EUT is a belt-worn tracking device incorporating ISM (915MHz) and GPRS communication capabilities.

3.2. Identification of Equipment Under Test (EUT)
ID#    Description             Brand Name                  Model No             Serial No                 IMEI
E1     Tracking Device         Stalker Alert               08                   000014                    352023007715879
E2     Power Supply Unit       Spry Power Products         PA1015-2HU           091201540                 Not Applicable

3.3. Port Identification
Port      Description                                                                                  Type
P1        Enclosure (Tracking Device)                                                                 -
P2        12V DC Power input (Tracking Device)                                                        DC Barrel Socket
P3        AC Input (Power Supply Unit)                                                                 2 Pin

3.4. Operating Modes
Mode Reference                            Definition
ISM Transmit Mode                         The EUT was configured to constantly transmit at maximum power 915MHz


ISM Radio characteristics
Transmit Frequency Range (MHz):           902 – 928

Transmit Channel Tested (MHz):            915

3.5. Configuration and Peripherals
Description:                              The Tracking Device was configured to constantly transmit at maximum power
                                          915MHz, whilst powered via 110 V, 60 Hz.
                                          Please refer to the Test Configuration and Photograph section for schematic
                                          drawing(s) and/or photograph(s) of the test configuration(s) employed in the course
                                          of testing.

3.6. Modifications
Modification Date        Customer Reference          Details of Modification              Measurements Effected
NOTE: No modifications were made to the EUT during the course of testing.

3.7. Additional Information Related to Testing
Equipment Category:                       Short Range Device
Cycle Time:                               <1s
Power Supply Requirement(s):              230V AC to charger; 12V DC from Charger to Tracker; 3.7V Li Ion in Tracker
Weight:                                   ~170g
Dimensions:                               117mm x 75mm x 27mm
Antenna Type                              Integral
FCC ID:                                   S5EBTV0909




RFI Global Services Ltd.                                                                                           Page 7 of 26


TEST REPORT                                                             SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                    ISSUE DATE: 13 MAY 2010




4. SUPPORT EQUIPMENT
4.1. Identification of Support Equipment
Description                           Manufacturer           Model No               Serial No
No support equipment was used during the course of testing




Page 8 of 26                                                                       RFI Global Services Ltd.


TEST REPORT                                                                           SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                                     ISSUE DATE: 13 MAY 2010




5. MONITORING PERFORMANCE
5.1. Overview
No immunity testing was performed; therefore performance criteria were not used to asses the EUT during testing.

5.2. Monitoring EUT Performance During Testing
For the purposes of testing, the term “operate as       The EUT continued to transmit at 915MHz.
intended” was defined as:
For the purposes of testing, an “unintentional          Not applicable
response” was defined as:

Method used to determine whether user control           Not applicable
functions and stored data were lost after the EMC
exposure:
Method used to verify that a communications link        Not applicable
was established and maintained (if appropriate):


Method of assessment of level of performance or         Not applicable
degradation of performance during and/or after
EMC exposure:




RFI Global Services Ltd.                                                                                           Page 9 of 26


TEST REPORT                                                            SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                    ISSUE DATE: 13 MAY 2010




6. MEASUREMENT UNCERTAINTY
6.1. Overview
No measurement or test can ever be perfect and the imperfections give rise to error of measurement
in the results. Consequently, the result of a measurement is only an approximation to the value of the
measurand (the specific quantity subject to measurement) and is only complete when accompanied
by a statement regarding the uncertainty of approximation.
The measurement uncertainty may need to be taken into account when interpreting the test results
included within this test report.

6.2. Method of calculation
The methods used to calculate the uncertainties included within this test report are in line with those
recommended within the various measurement specifications. Where measurement specifications do
not include guidelines for the evaluation of measurement uncertainty, the published guidance of the
United Kingdom Accreditation Service (UKAS) is followed.




Page 10 of 26                                                                       RFI Global Services Ltd.


TEST REPORT                                                             SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                      ISSUE DATE: 13 MAY 2010




7. MEASUREMENTS, EXAMINATIONS AND DERIVED RESULTS
7.1. General Comments
7.1.1. This section contains the test result sheets for the measurements listed in Section 2.2.
Summary of Test Results (above).
7.1.2. The measurement uncertainties stated in the test result sheets were calculated in accordance
with documented best practice and represent a confidence level of 95%. Where only confidence level
is given, it has been demonstrated that the relevant items of test equipment used meet the specified
requirements in the standard with at least this level of confidence.
7.1.3. Please refer to Section 6. Measurement Uncertainty on page 10 for details of our treatment of
measurement uncertainty.




RFI Global Services Ltd.                                                                     Page 11 of 26


 TEST REPORT                                                                            SERIAL NO: RFI-EMC-RP76131JD02A

 VERSION: 2.0                                                                                      ISSUE DATE: 13 MAY 2010



                           RADIATED EMISSIONS - TEST RESULTS
 This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION
RFI JOB NUMBER:              76131JD02                                  TEST SITE ID:                                 Site 1
EUT:                         Victim Unit                                TEMPERATURE:                         27 °C      to     27 °C
TEST ENGINEER:               Richard Hooper/Jack Suter                  RELATIVE HUMIDITY:                   33 %       to     33 %
DATE OF TEST:                27 Oct 2009/ 28 April 2010                 ATMOSPHERIC PRESSURE:               1009 mb     to 1009 mb
FIELD TYPE:                  Electric Field                             MEASUREMENT DISTANCE:                3     Metres
UNCERTAINTY (±):              ±4.68 dB                                  EQUIPMENT CLASS:                              Class B
MEASUREMENT UNITS:           dBµV/m                                     TEST ENVIRONMENT:                           Test Site


TEST SPECIFICATION DETAILS
The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic
standard:
REFERENCE:                    CFR47 Parts 15.209
TITLE:                        Code of Federal Regulations Volume 47 (Telecommunications) 2008: Part 15
                              (Radio Frequency Devices) – Section 15. 209



COMMENTS
 -


DEVIATIONS FROM TEST SPECIFICATION
 There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified
 above).



EUT RELATED
OPERATING MODE:               ISM 915MHz Transmit
FUNCTION(S) MONITORED: None Applicable




MEASUREMENT RESULTS

         Frequency                                  Level                          Margin
 No.                   Polarity      Detector                   Limit (dBµV/m)                     Graph No.                 Result
           (MHz)                                  (dBµV/m)                          (dB)

 1        30.418       Vertical    Quasi-Peak        31.1            40.0            8.9      GPH\76131JD02\001          Complied
 2        41.485       Vertical    Quasi-Peak        35.0            40.0            5.0      GPH\76131JD02\001          Complied
 3        41.514       Vertical    Quasi-Peak        35.0            40.0            5.0      GPH\76131JD02\001          Complied
 4        41.525       Vertical    Quasi-Peak        35.2            40.0            4.8      GPH\76131JD02\001          Complied
 5        44.709       Vertical    Quasi-Peak        37.9            40.0            2.1      GPH\76131JD02\001          Complied
 6        51.927       Vertical    Quasi-Peak        27.9            40.0           12.1      GPH\76131JD02\001          Complied
 7        86.242       Vertical    Quasi-Peak        23.5            40.0           16.5      GPH\76131JD02\001          Complied
 8        94.490       Vertical    Quasi-Peak        35.1            43.5            8.4      GPH\76131JD02\001          Complied
 9        102.295      Vertical    Quasi-Peak        32.7            43.5           10.8      GPH\76131JD02\001          Complied
 10       129.875      Vertical    Quasi-Peak        24.6            43.5           18.9      GPH\76131JD02\001          Complied
 11       696.317     Horizontal   Quasi-Peak        21.2            46.0           24.8      GPH\76131JD02\001          Complied

 12       915.00                                 Refer to Note 1                              GPH\76131JD02\001          Complied
                                     Average
 13       1829.81     Horizontal     (CIPSR)         49.4            54.0            4.6      GPH\76131JD02\002          Complied


 Page 12 of 26                                                                                         RFI Global Services Ltd.


 TEST REPORT                                                                            SERIAL NO: RFI-EMC-RP76131JD02A

 VERSION: 2.0                                                                                      ISSUE DATE: 13 MAY 2010



MEASUREMENT RESULTS

         Frequency                                   Level                         Margin
 No.                    Polarity       Detector                   Limit (dBµV/m)                  Graph No.               Result
           (MHz)                                   (dBµV/m)                         (dB)
             4000                                                                            GPH\76131JD02\003
              to                                                                                    to
 14         10000                                 Refer to Note 2                            GPH\76131JD02\004           Complied


NOTES
 1       This emission was observed to be the transmit frequency of the equipment under test; therefore no further measurements
         were made.
 2       Within this frequency range, no emissions were noted above the noise floor of the measurement system. Therefore no
         further measurements were made.


TEST EQUIPMENT USED

RFI ID       INSTRUMENT DESCRIPTION                      MODEL NUMBER                   CALIBRATION DUE             INTERVAL
 K0001         5m Semi-Anechoic Chamber                    N/A                                 25 Apr 2011                         12
 L1001         26.5 GHz Test Receiver                      ESU26                               28 Jan 2011                         12
 A553          Bi-log Antenna                              CBL6111A                           16 Mar 2011                          12
 A1817         1-18GHz Horn Antenna                        3115                               27 Nov 2010                          12
 C1306         15m Rosenberger Cable                       FA210A0015005050                   23 Feb 2011                          12
 C1303         8m Rosenberger Cable                        FA210A1080005050                   23 Feb 2011                          12
 A1834         3dB N-Type Attenuator                       8491B                               24 Oct 2010                         12
 L1005         CMU200 Radio Communication Tester           CMU200                        Calibration not required
 C1339         N-male to N-male cable                      0                                  23 Feb 2011                          12
 M172          Electronic Environmental Monitor            BA-116                              21 Jul 2010                         12




 RFI Global Services Ltd.                                                                                           Page 13 of 26


 TEST REPORT                                                                                SERIAL NO: RFI-EMC-RP76131JD02A

 VERSION: 2.0                                                                                       ISSUE DATE: 13 MAY 2010




                         CONDUCTED EMISSIONS - TEST RESULTS
This test is covered by the scope of RFI's UKAS Accreditation under ISO/IEC 17025: 2005.
GENERAL INFORMATION
RFI JOB NUMBER:        76131JD02                                            TEST SITE ID:                          Site 8
EUT:                   Victim Unit                                          TEMPERATURE:                   30 °C    to      30 °C
TEST ENGINEER:         Eric Phiri                                           RELATIVE HUMIDITY:             31 %     to      31 %
DATE OF TEST:          30 Oct 2009                                          ATMOSPHERIC PRESSURE: 1011 mb           to 1011 mb
UNCERTAINTY (±):       ±3.99 dB                                             EQUIPMENT CLASS:                       Class B
CATEGORY:              Not applicable                                       MEASUREMENT METHOD:                   LISN (AC)


TEST SPECIFICATION DETAILS
The EUT has been configured and tested in accordance with the methods and procedures detailed within the following basic
standard:
REFERENCE:             CFR47 Parts 15.207
TITLE:                 Code of Federal Regulations Volume 47 (Telecommunications) 2008: Part 15
                       (Radio Frequency Devices) – Section 15. 207



COMMENTS
No comments were noted by the engineer at the time of the test.


DEVIATIONS FROM TEST SPECIFICATION
There were no deviations from the test configuration and measurement arrangements defined in the test specification (identified
above).



EUT RELATED
OPERATING MODE:        ISM 915MHz Transmit
FUNCTION(S)            None
MONITORED:



MEASUREMENT RESULTS

         Frequency                                     Level        Limit       Margin
 No.                   Line            Detector                                                Graph No.             Result
           (MHz)                                      (dBµV)       (dBµV)        (dB)

  1        0.164      Neutral         Quasi-Peak        55.4         65.3         9.9    GPH\76131JD02\005          Complied
  2        0.182      Live 1          Quasi-Peak        53.3         64.4        11.1    GPH\76131JD02\005          Complied
  3        0.213      Neutral         Quasi-Peak        50.6         63.1        12.5    GPH\76131JD02\005          Complied
  4        0.416      Neutral         Quasi-Peak        50.4         57.5         7.1    GPH\76131JD02\005          Complied
  5        0.420      Neutral         Quasi-Peak        50.8         57.4         6.6    GPH\76131JD02\005          Complied
  6        0.731      Neutral         Quasi-Peak        45.4         56.0        10.6    GPH\76131JD02\005          Complied
  7        0.735      Neutral         Quasi-Peak        45.8         56.0        10.2    GPH\76131JD02\005          Complied
  8        0.956      Neutral         Quasi-Peak        46.6         56.0         9.4    GPH\76131JD02\005          Complied
  9        0.992      Neutral         Quasi-Peak        46.1         56.0         9.9    GPH\76131JD02\005          Complied
 10        1.248      Neutral         Quasi-Peak        45.9         56.0        10.1    GPH\76131JD02\005          Complied
 11        1.307      Neutral         Quasi-Peak        47.1         56.0         8.9    GPH\76131JD02\005          Complied
 12        1.604      Neutral         Quasi-Peak        45.4         56.0        10.6    GPH\76131JD02\005          Complied
 13        1.901      Neutral         Quasi-Peak        42.7         56.0        13.3    GPH\76131JD02\005          Complied
 14        0.362      Neutral       Average (CISPR)     35.6         48.7        13.1    GPH\76131JD02\005          Complied

 Page 14 of 26                                                                                          RFI Global Services Ltd.


 TEST REPORT                                                                              SERIAL NO: RFI-EMC-RP76131JD02A

 VERSION: 2.0                                                                                       ISSUE DATE: 13 MAY 2010



MEASUREMENT RESULTS

         Frequency                                      Level       Limit      Margin
 No.                    Line          Detector                                               Graph No.              Result
           (MHz)                                       (dBµV)      (dBµV)       (dB)

 15        0.425      Neutral     Average (CISPR)       39.3           47.4      8.1    GPH\76131JD02\005          Complied
 16        0.429      Neutral     Average (CISPR)       38.9           47.3      8.3    GPH\76131JD02\005          Complied
 17        0.488      Neutral     Average (CISPR)       37.8           46.2      8.4    GPH\76131JD02\005          Complied
 18        0.492      Neutral     Average (CISPR)       32.5           46.1     13.6    GPH\76131JD02\005          Complied
 19        0.672      Neutral     Average (CISPR)       32.3           46.0     13.7    GPH\76131JD02\005          Complied
 20        0.722      Neutral     Average (CISPR)       33.1           46.0     12.9    GPH\76131JD02\005          Complied
 21        0.735      Neutral     Average (CISPR)       33.3           46.0     12.7    GPH\76131JD02\005          Complied
 22        0.965      Neutral     Average (CISPR)       32.4           46.0     13.6    GPH\76131JD02\005          Complied
 23        0.983      Neutral     Average (CISPR)       32.0           46.0     14.0    GPH\76131JD02\005          Complied
 24        0.987      Neutral     Average (CISPR)       31.8           46.0     14.2    GPH\76131JD02\005          Complied
 25        1.289      Neutral     Average (CISPR)       31.3           46.0     14.7    GPH\76131JD02\005          Complied
 26        1.554      Neutral     Average (CISPR)       31.9           46.0     14.1    GPH\76131JD02\005          Complied
 27        1.851      Neutral     Average (CISPR)       31.0           46.0     15.0    GPH\76131JD02\005          Complied
 28        2.985      Neutral     Average (CISPR)       30.0           46.0     16.0    GPH\76131JD02\005          Complied


NOTES
N/A       During measurement the engineer did not record any specific notes relevant to report.


TEST EQUIPMENT USED

RFI ID     INSTRUMENT DESCRIPTION                                MODEL NUMBER                CALIBRATION DUE         INTERVAL
           Conducted AC Emissions / Conducted RF immunity
K0008      Laboratory                                            N/A                         Calibration not required N/A
           20 Hz - 26.6 GHz EMI Test Receiver, Rhode &
M1273      Schwarz                                               ESIB 26                     08 Apr 2011             12
C1304      3m Rosenberger Cable                                  FA210A1030005050            22 Feb 2011             12
A1829      N-Type Pulse Limiter                                  ESH3-Z2                     25 Oct 2010             12
C1262      7m BNC Coaxial                                        FA210A0075008080            03 Apr 2010             12
M172       Electronic Environmental Monitor                      BA-116                      21 Jul 2010             12
A067       Line Impedance Stabilization Network                  ESH3-Z5                     03 Jun 2010             12




 RFI Global Services Ltd.                                                                                         Page 15 of 26


TEST REPORT                                                              SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                     ISSUE DATE: 13 MAY 2010




8. PHOTOGRAPHS OF EUT

This section contains the following photographs:

Photo Reference Number                             Title

PHT\76131JD02\001                                  Conducted Emissions
PHT\76131JD02\002                                  Radiated Emissions




Page 16 of 26                                                                    RFI Global Services Ltd.


TEST REPORT                               SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                      ISSUE DATE: 13 MAY 2010



PHT\76131JD02\001 - Conducted Emissions




RFI Global Services Ltd.                                      Page 17 of 26


rugy rv vene   ree e cevnir nvr n en ce


TEST REPORT                                                           SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                   ISSUE DATE: 13 MAY 2010




9. GRAPHICAL TEST RESULTS

9.1. This section contains the graphical results for the measurements listed in Section 2.2. Summary
of Test Results (above).




RFI Global Services Ltd.                                                                   Page 19 of 26


           w

           m

           m

           «

           w

           #                         ree pat1s cats o iss svenin on it

           m

           «
esn stwi




           a

           x    *           e
                            +
           »P
                    *
           a
                        +
           a

           C

           w

           s

           ale n
           on  ie on sn vone        mm   war on m. wam io
                             Fesueney ie


           w
           a
           w
           «
           w
           m
           m
           «
           w
esn stwi




           =




           x
           »
           a
           a




           ol 1e    2o     2 i
               Fesueney ie


      w

      m                              reic w1 cce raus Sveramince on

      m

      «

      w
                                          ic y Juliwigt
                                                i
      #
                        fry mabl
                                 stqualiMRBNEB      nl o
      m
esn stwi
    a




      x

      »

      a

      a




           «   «s   s            s          s         s           —
                           Fesseney none


           w

           m                          rcit 16 ces is Svecanibio on

           m

           «
esn stwi




           »

           a

           a




               —   #a   s         s         >         o          io
                            Fesseney none


TEST REPORT                                                                                      SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                                                  ISSUE DATE: 13 MAY 2010



GPH\76131JD02\005


                                            FCC Part 15 Class B Voltage with 2-Line-LISN scans




                         80



                         75



                         70



                         65


                                                                                    FCC Part 15 Class B Voltage on Mains QP
                         60



                         55


                                                                                    FCC Part 15 Class B Voltage on Mains AV
                         50



                         45
         Level in dBµV




                         40



                         35



                         30



                         25



                         20



                         15



                         10



                          5



                          0
                          150k   300   400 500     800 1M            2M       3M   4M 5M 6       8 10M            20M     30M
                                                               Frequency in Hz




Page 24 of 26                                                                                                 RFI Global Services Ltd.


TEST REPORT                                                             SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                                                       ISSUE DATE: 13 MAY 2010




10. TEST CONFIGURATION DRAWING

10.1. This section contains the Test Configuration Drawings for the measurements listed in Section 7:
Measurements, Examinations and Derived Results.



Test Configuration Reference Number                Title
DRG\76131JD02\001                                  Configuration of EUT and Local Support Equipment




RFI Global Services Ltd.                                                                         Page 25 of 26


TEST REPORT                                  SERIAL NO: RFI-EMC-RP76131JD02A

VERSION: 2.0                                         ISSUE DATE: 13 MAY 2010



DRG\76131JD02\001 - Test Schematic Diagram




Page 26 of 26                                        RFI Global Services Ltd.



Document Created: 2010-05-13 14:27:17
Document Modified: 2010-05-13 14:27:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC