Manual

FCC ID: S5751454941

Users Manual

Download: PDF
FCCID_3961118

SmartLine Wireless Pressure Transmitter
ST 700 Gauge Pressure Models Specification
34-SW-03-xx, June 2018



Models:
STGW740           0 to 500 psi       0 to 35,000 mbar
STGW770           0 to 3,000 psi     0 to 210,000 mbar
STGW73L           0 to 50 psi        0 to 3,500 mbar
STGW74L           0 to 500 psi       0 to 35,000 mbar
STGW77L           0 to 3,000 psi     0 to 210,000 mbar
STGW78L           0 to 6,000 psi     0 to 420,000 mbar
STGW79L           0 to 10,000 psi    0 to 690,000 mbar


Introduction
SmartLine Wireless Pressure continues the evolution of
Honeywell’s wireless transmitter product offering and
provides the latest critical advancements to support
industrial automation users’ desire to expand wireless
use for monitoring and control.

With over 14 years of industrial wireless experience,        Figure 1 — SmartLine Wireless Differential Pressure
the SmartLine Wireless Pressure builds upon and is                             Transmitters
compatible with the current XYR 6000 product porfotlio.
Similar to the XYR 6000 wireless transmitter, the         and operational in minutes, quickly providing information
SmartLine Wireless product line is part of the            back to your system.
Honeywell OneWireless™ system and is ISA100 -             The previous generation transmitters primarily were applied
ready.                                                    to monitoring applicaions but experienced users know that
                                                          Honeywell’s wireless products are as reliable, secure, and
SmartLine Wireless Pressure transmitters also
                                                          safe as their wired counterparts. With this knowledge, users
leverage SmartLine technology in the incorporaton of
                                                          are now looking for wireless transmiiters for use in specific
the enhanced SmartLine Pressure meter body. By
                                                          control applications.
utilizing the same meter body as in the non-wireless
pressure product offering, you get best-in-class          SmartLine Wireless introduces a step change in
performance, reduction in spares inventory, and a         performance and most notably, performance suitable for
lessening of the maintenance learning curve.              control. SmartLine Wireless performance is improved in
                                                          these ways:
The SmartLine Wireless Pressure transmitter enables
customers to obtain data and create information from                Fast ½ second publication rate
remote and hazardous measurement locations without
                                                                    Built-in additional noise reduction
the need to run wires, where running wire is cost
prohibitive and/or the measurement is in a hazardous                More powerful 4dBi integral antenna
location. Without wires, transmitters can be installed
                                                                    Good battery life performance even at ½ second
                                                                     publication rate.


SmartLine Wireless Pressure retains the following        Span & Range Limits:
desirable features from the XYR 6000 product offering:

        Mesh or non-mesh configuration within each        Model    URL / Max        LRL         Min Span psi
         transmitter
                                                                      Span        psi (bar)          (bar)
        Generic, off-the-shelf lithium ion battery.                 psi (bar)
                                                         STGW740     500 (35)     -14.7 (-1.0)      5 (.35)
        Two “D” size batteries for longer life.
                                                         STGW770    3000 (210)    -14.7 (-1.0)     30 (2.1)
        Choice of over-the-air or local provisioning    Model       psi (bar)     psi (bar)       psi (bar)
         (network security join key)
                                                         STGW73L     50 (3.5)     -14.7 (-1.0)     0.5 (.035)
        Over-the-air firmware upgrade capability        STGW74L     500 (35)     -14.7 (-1.0)      5 (.35)

        Unique, encrypted provisionng key delivered
                                                         STGW77L    3000 (210)    -14.7 (-1.0)     30 (2.1)
         from the factory                                STGW78L    6000 (420)    -14.7 (-1.0)     60 (4.2)

        Remote and integral antenna options
                                                         STGW79L    10000 (690)   -14.7 (-1.0)     100 )6.9)


        24 VDC power option

        Publication rates of 1, 5, 10, or 30 seconds,
         plus new selections for ½ sec, and 1, 15, 30,
         60 minutes

        Transmitter range (integral antenna) of 1150’
         (350 m) under ideal conditions.

The STGW700 dual head and inline gauge pressure
series are suitable for monitoring, control and data
acquisition. STGW700 dual head products feature
piezoresistive sensor technology combining pressure
sensing with on-chip temperature compensation
capabilities providing high accuracy, stability and
performance over a wide range of application
pressures and temperatures

Best in Class Features:

 o   Accuracy up to 0.065 % of calibrated span
 o   Stability up to 0.025% of URL per year for five
     years
 o   Automatic temperature compensation
 o   Rangeability up to 100:1
 o   Intuitive external zero & span capability
 o   Integral dual seal design for safety based on
     ANSI/NFPA 70-202 and ANSI/ISA 12.27.0


Smart Line Wireless Features                              Mesh and non-mesh capability. All SmartLine Wireless
 Local and over-the-air provisioning capability. All      transmitters can be configured to operate in either a mesh
 Honeywell wireless devices feature a secure method       network or a star (non-mesh) network. The configuration
 to join the local wireless network, also known as        is specific to each wireless transmitter and thus the
 provisioning. SmartLine Wireless transmitters feature    network can consist of a mixture of meshing and non-
 two methods to provision a transmitter onto the          meshing devices. Non-meshing is desirable for
 network which are either by using a handheld device      deterministic communications which is preferred for
 to locally communicate through the IR interface or       control.
 remotely using the over-the-air function. The over-
                                                          Transmission power setting. To comply with local and
 the-air function is managed by the OneWireless
                                                          regional requirements, SmartLine Wireless transmitters are
 gateway, Wireless Device Manager (WDM).
                                                          set at the factory to the maximum transmission power
 In either method, the communication of secure,           setting allowed for the country of use.
 unique provisioning keys is one of the main factors to
                                                          Non-proprietary battery. Sourcing lithium thionyl chloride
 prevent against unintended access. Honeywell’s
                                                          batteries is much simpler since SmartLine Wireless utilizes
 security keys are unique for each device from the
                                                          commercial off-the-shelf batteries. Please see the list of
 factory, never made visible, always encrypted, and
                                                          approved battery manufacturers later in this specification.
 uniquely generated from the gateway that manages
                                                          Batteries are housed in an IS-approved battery
 the deployed network.
                                                          compartment making battery changes safe and easy.
 Over-the-air firmware updates. Once joined as a
                                                          Backward compatibility. SmartLine Wireless transmitters
 member of your OneWireless network, the WDM can
                                                          can join existing OneWireless networks and interoperate
 download new transmitter firmware releases to each
                                                          with existing XYR 6000 wireless transmitters or other
 SmartLine Wireless transmitter over the wireless
                                                          ISA100 Wireless compliant transmitters or networks.
 network. Locating and accessing the transmitter
 locally is not required thus saving time and keeping
 your personnel in safe environments.


 OneWireless Network Features
 The core of the Honeywell wireless solution is the OneWireless Network which consists a gateway, access point(s), and
 field routers.
 The Wireless Device Manager (WDM) serves as the gateway function and in this role, manages the communication from
 the wireless field devices to the process control application. Typically, the WDM connects logically to the process control
 network (Level 2 or wireless DMZ). As the wireless network manager, the WDM provides easy access to the entire
 wireless network through a browser-based user interface. The Honeywell WDM can manage devices communicating over
 the ISA100 Wireless protocol and the WirelessHART protocol.
 The ability to deploy redundant WDMs improves the reliability ensuring no loss of process data which is a requirement for
 control applications.
 The Field Device Access Point (FDAP) serves in two roles in the OneWireless network infrastructure, which are: 1) access
 point, and 2) field router. As an access point, the FDAP directly connects to the WDM via Ethernet LAN cable. More than
 one access point is permitted and, when more than one is present, it ensures dual path for communications into the WDM
 from the field devices. As a field router, the FDAP located in the field would communicate to the FDAP acting as an access
 point. Using the FDAP as a router is more efficient than using field devices as routers since FDAPs are line powered
 devices whereas field devices are typically battery powered, and the FDAP offers greater range. The meshing capability of
 FDAPs allows flexibility in the setup of the wireless network to fit the requirements for wireless network performance, in
 terms of reliable communications, performance, and future growth.
 The choice of non-meshing network may be desirable for decreased communication latency which a FDAP serving as a
 field router helps ensures.


Wireless Specifications

   Parameter                     Description
   Wireless                     2,400 to 2,483.5 MHz (2.4 GHz) Industrial, Scientific and Medical (ISM) band
   Communication                DSSS - Direct Sequential Spread Spectrum per FCC 15.247 / IEEE 802.15.4 2006
                                Every data packet transmitted in either direction is verified (CRC check) and acknowledged by
                                the receiving device.
                                USA – FCC Certified
                                Canada – IC Certified
                                European Union – Radio Equipment Directive compliant
   DSSS RF Transmitter          NA Selection –100 mW (20.0 dBm) maximum EIRP including antenna for USA and Canadian
   Power                        locations.
                                EU Selection – 63 mW (18 dBm) maximum EIRP including antenna per RTTE/ETSI for EU
                                locations. Compliant to ETSI EN 300 328 wireless standard
   Data                         PV Publish Cycle Time: Configurable as 0.5, 1, 5, 10, 30 seconds, plus 1, 15, 30, 60 minutes
                                Rate: 250 Kbps
   Antennas                     Integral – 4 dBi omnidirectional monopole (default selection)
                                Remote – 8 dBi omnidirectional monopole with up to 20 m cable and lightning surge arrester
                                Remote – 14 dBi directional parabolic with up to 20 m cable and lightning surge arrester.
   Signal Range                 Nominal 350 m (1150 feet) between Field Transmitter and Infrastructure Unit (FDAP) when
                                using 4 dBi Integral antenna with a clear line of sight*
*Actual range will vary depending on antennas, cables and site topography.


Specifications
Operating Conditions – All Models


               Parameter                   Reference            Rated Condition            Operative Limits           Transportation
                                           Condition                                                                   and Storage
                                            (at zero
                                             static)
                                           °C      °F             °C              °F          °C              °F       °C              °F

Ambient Temperature**                    25 ±1 77 ±2         -40 to 85*    -40 to 185*   -40 to 85*     -40 to 185* -55 to 120 -67 to 248
Ambient Temperature                      25 ±1 77 ±2         -40 to 85°C -40 to 185°F
LCD Display visible range
Meter Body Temperature                   25 ±1 77 ±2         -40 to 110    -40 to 230    -40 to 125     -40 to 257 -55 to 120 -67 to 248
Humidity                     %RH                10 to 55               0 to 100                    0 to 100                 0 to 100

    Vacuum Region - Minimum
    Pressure All Models
              mmHg absolute               Atmospheric                     25                  2 (short term1)
              in H2O absolute             Atmospheric                     13                  1 (short term1)

Maximum Allowable Working                Standard:
Pressure (MAWP) 2,3                       STGW740:         500 psi (35 bar)
                                          STGW770:         3000 psi (210 bar)
(ST700 products are rated to              STGW73L:         50 psi (3.5 bar)
Maximum Allowable Working                 STGW74L:         500 psi (35 bar)
Pressure. MAWP depends on                 STGW78L:         6000 psi (420 bar)
Approval Agency and transmitter           STGW79L:         10000 psi (690 bar)
materials of construction.)
Vibration                                Maximum of 4g over 15 to 200Hz.
Shock                                    Maximum of 40g.
                                         Commercially available, non-proprietary 3.6V Lithium thionyl chloride (LiSOCl2) batteries,
                                         non-rechargeable, size D.
                                         Battery pack-only option is available.
                                         Approved list of the manufacturer models:
                                                 1.   Xeno Energy XL-205F
Power                                            2.   Eagle Picher PT-2300H
                                                 3.   Tadiran TL-5930/s
                                         24 VDC power option.4
                                         For Non I.S. application: 16 to 28 VDC Input range, max input current 100mA.
                                         For I.S. application: Barrier in accordance with the control drawing required, Entity
                                         parameters 30V, 120mA, 0.9W
1Short    term equals 2 hours at 70°C (158°F)
2 Units   can withstand overpressure of 1.5x MAWP without damage.
3 Consult   factory for MAWP of SmartLine Wireless transmitters with CRN approval.
4
24V power option rated 80°C (176°F)
** The Ambient Limits shown are for Ordinary Non-Hazardous locations only. Refer to the appropriate Control Drawing, FM/CSA, ATEX, or
IECEx for the Ambient Limits when installed in Hazardous Locations.


Remote Antenna Cables




Remote Antennas




               8 dBi Omnidirectional Antenna   14 dBi Directional Antenna


Performance Specifications
Reference Accuracy (conformance to +/-3 Sigma)

                                                                  Table 1
         Model                  URL                   LRL                 Min Span         Maximum           Stability          Reference
                              psi (bar)             psi (bar)             psi (bar)        Turndown         (% URL/ Yr          Accuracy1,2
                                                                                             Ratio         for ten years)        (% Span)
      STGW740                500 (35)              -14.7 (-1.0)             5 (0.35)          100:1            0.025              0.0650%
      STGW770               3000 (210)             -14.7 (-1.0)             30 (2.1)          100:1            0.025              0.0650%
      STGW73L                 50 (3.5)             -14.7 (-1.0)          0.5 (0.035)          100:1            0.025              0.0650%

      STGW74L                500 (35)              -14.7 (-1.0)             5 (0.35)          100:1            0.025              0.0650%

      STGW78L               6000 (420)             -14.7 (-1.0)             60 (4.2)          100:1            0.025              0.0650%

      STGW79L              10000 (690)             -14.7 (-1.0)             100 (6.9)         100:1            0.025              0.0650%
Zero and span may be set anywhere within the listed (URL/LRL) range limits

Accuracy at Specified Span, Temperature and Static Pressure Effects: (conformance to +/-3)


                                                         Table to be provided




Total Performance (% of Span):
       Total Performance Calculation: = +/- √ (Accuracy)2 + (Temperature Effect)2

          Total Performance Examples (for comparison): @ 5:1 Turndown, +/-50oF (28oC) shift

                                                         Table to be provided


Typical Calibration Frequency:
        Calibration verification is recommended every two (2) years

Notes:
1.Terminal Based Accuracy - Includes combined effects of linearity, hysteresis, and repeatability. Analog output adds 0 .006% of span.
2.For zero based spans and reference conditions of: 25 oC (77 oF) for LRV > = 0 psia, 10 to 55% RH, and 316 Stainless Steel barrier
diaphragm.


Performance Under Rated Conditions – All Models
  Parameter                      Description
 Vibration Effect                Less than +/- 0.1% of URL w/o damping
                                 Per IEC60770-1 field or pipeline, high vibration level (10-2000Hz: 0.21 displacement /
                                 3g max acceleration)
 Electromagnetic Compatibility   IEC 61326-3-1
 Lightning Protection Option     Leakage Current: 10uA max @ 42.4VDC 93C
                                 Impulse rating: 8/20uS       5000A (>10 strikes)           10000A (1 strike min.)
                                                    10/1000uS      200A (> 300 strikes)
 Lightning Surge Arrester        Frequency range: 0 – 3 GHz, 50 Ohms, VSWR = 1:1.3 Max, Insertion Loss = 0.4 dB
 (Remote antenna only)           Connectors Type N Female, Max, Gas Tube Element: 90 V ± 20%, Impulse
                                 Breakdown Voltage = 1,000 V ± 20%, Maximum Withstand Current = 5 KA.
 CE Conformity                   These transmitters are in conformity with the Radio Equipment Directive, ETSI EN 300
                                 328 V2.1.1 including EMC standard EN61326-1 2013


Physical Specifications
          Parameter                                                                  Description
    Mounting Bracket                          Carbon Steel (zinc-plated) or Stainless Steel angle bracket or flat bracket available.
    Electronic Housing                        Meets NEMA 4X (hosedown and corrosion resistant), IP 66/67 (hosedown and
                                              submersible to 1m).
                                              Epoxy-Polyester hybrid paint. Low Copper-Aluminum with 1/2” NPT or M20 Conduit
                                              Connections.

    Stainless Steel Housing (option) 316 SS Electronics Housing - with M20 Conduit Connections
                                              316 SS Housing with 1/2" NPT Conduit Connection
                                              316 SS or Grade CF8M, the casting equivalent of 316 SS with M20 or 1/2" NPT Conduit
                                              Connection.
                                              If ordered with the Remote Antenna options, the antenna parts are not SS or Marine type
                                              cables; the integral antenna uses SS parts.
    Process Connections                       1/4-inch NPT; 1/2-inch NPT with adapter. Process heads meet DIN 19213 requirements.
    Mounting                                  Can be mounted in virtually any position using the standard mounting bracket. Mounting
                                              should result in the antenna being vertically oriented. Bracket is designed to mount on 2-
                                              inch (50 mm) vertical or horizontal pipe. See Figure 2.
    Dimensions                                See Error! Reference source not found., Figure 4 and Figure 5
    Net Weight                                Approximately 11 pounds (5 Kg) for STGW7X0, and 7 pounds (3.2 kg) for STGW7XL


Materials Specifications (see model selection guide for availability/restrictions with various models)
     Parameter                                   Description
     Barrier Diaphragms Material                STG700 Dual Head: 316L SS, Hastelloy® C-2762
                                                STG700 Inline: 316L SS, Hastelloy® C-2762

     Process Head Material                      STG700 Dual Head: 316 SS3
                                                STG700 Inline: 316L SS

     Vent/Drain Valves & Plugs 1                STG700 Dual Head:316 SS3
                                                STG700 Inline: N/A

     Head Gaskets                               STG700 Dual Head: Glass-filled PTFE standard.
                                                STG700 Inline: N/A
                                                STG700 Dual Head: Carbon Steel (Zinc plated) standard. Options include 316 SS,
     Meter Body Bolting                           NACE A286 SS bolts and nuts.
                                                STG700 Inline: N/A
     Fill Fluid                                 Silicone DC 200 oil, NEOBEE M-20, or CTFE (Chlorotrifluoroethylene)
1                                   ®
    Vent/Drains are sealed with Teflon
2
    Hastelloy C-276 or UNS N10276
3
    Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.


                       Dual Head Gauge




                         In-Line Gauge
Figure 2 — Examples of typical mounting positions (antenna omitted)


                        millimeters
Reference Dimensions:
                          inches




                                      Dual Head Gauge


                In-Line Gauge

Figure 3 – Informational and dimensional drawing


                                    Dual Head Gauge




                                     In-Line Gauge

Figure 4 — Typical mounting dimensions for STDW740, STDW770, STDW7(3,4,7,8,9)L (rear view)


Dual Head Gauge


                                     In-Line Gauge

Figure 5 — Typical mounting dimensions for STDW740, STDW770, STDW7(3,4,7,8,9)L (rear view)


Hazardous Locations Approvals
Refer to control drawing 50136123, in the User’s manual #34-SW-25-01, for intrinsically safe installation details


 AGENCY             TYPE OF PROTECTION                                      Ambient Temperature

                    Intrinsically Safe:
                    Class I; Division 1; Groups A, B, C, D;
                    Class II, Division 1, Groups E, F, G;                   -40 o C to +85 o C
                    Class III, Division 1; T4
                    Class I, Zone 0 Ex ia IIC T4
                    Class I, Zone 0 AEx ia IIC T4
                    Nonincendive:
                    Class I; Division 2; Groups A, B, C, D;                 -40 o C to +85 o C : T5
                    Class II, Division 2, Groups E, F, G;                   -40 o C to +70 o C : T6
       CSA
                    Class III, Division 2, T6..T5
                    Class I, Zone 0/2 ec [ia] IIC, T6..T5
    (USA and        Class I, Zone 0/2 AEx ec [ia] IIC, T6..T5
    Canada)         Explosion-Proof/ Flameproof/Dust Proof:
                    Class I, Division 1; Groups A, B, C, D;
                                                                            -40 o C to +85 o C : T5, T95C
                    Class II, Division 1, Groups E, F, G;
                                                                            -40 o C to +70 o C : T6
                    Class III, Division 1; T6..T5
                    Class I, Zone 0/1 Ex d [ia] IIC T6..T5
                    Class I, Zone 0/1 AEx d [ia] IIC, T6..T5
                    DIP A21/II, III/1/EFG/Ex tb IIIC T95C
                     Enclosure: Type 4X/ IP66/ IP67


 AGENCY             TYPE OF PROTECTION                                      Ambient Temperature

                    Intrinsically Safe:
                    IS Class I, II, III; Division 1; Groups ABCDEFG; T4    -40 °C to +85 °C
                    Class I, Zone 0 AEx ia IIC Ga T4
                    Class I, Zone 2[0] AEx ic [ia Ga] IIC Gc T4
                    Nonincendive:
                    NI-AIS Class I; DIV 2; Groups ABCD; T5..T6              -40 °C to +85 °C : T5
      FM            Class I, Zone 2[0] AEx nA [ia Ga] IIC Gc, T5..T6        -40 °C to +70 °C : T6
  ApprovalsTM
     (USA)

                    Dust Proof:                                             -40 °C to +85 °C : T5, T95°C
                    DIP-AIS Class II, III DIV 1, Groups EFG; T5..T6         -40 °C to +70 °C : T6
                    Zone 21[20] AEx tb [ia Da] IIIC T95°C Db


                     Enclosure: Type 4X/ IP66/ IP67


 AGENCY            TYPE OF PROTECTION                                       Ambient Temperature

                    Intrinsically Safe:
                                                                            -40 o C to +85 o C
                    II 1 G Ex ia IIC T4 Ga
                    II 3 G Ex ic IIC T4 Gc
                    Flameproof / Dust Proof:                                -40 o C to +85 o C : T5, T95C
     ATEX           II 2[1] G Ex d [ia] IIC T6..T5 Gb[Ga]                   -40 o C to +70 o C : T6
                    II 2[1] D Ex tb [ia] IIIC T95C Db[Da]
                    Nonincendive:                                           -40 o C to +85 o C : T5
                    II 3[1] G Ex ec [ia] IIC T6..T5 Gc[Ga]                  -40 o C to +70 o C : T6
                    Enclosure: IP66/ IP67


 AGENCY            TYPE OF PROTECTION                                       Ambient Temperature


                    Intrinsically Safe:
                                                                            -40 o C to +85 oC
                    Ex ia IIC T4 Ga
                    Ex ic IIC T4 Gc
                    Flameproof / Dust Proof:                                -40 o C to +85 o C : T5, T95C
                    Ex db [ia] IIC T6..T5 Gb[Ga]                            -40 o C to +70 o C : T6
     IECEx          Ex tb [ia] IIIC Db[Da] T95C
                    Nonincendive:                                           -40 o C to +85 o C : T5
                    Ex ec [ia] IIC T6..T5                                   -40 o C to +70 o C : T6

                    Enclosure: IP66/ IP67




Transmitter Options
(indicated selection code is shown)

ISA100 Wireless Release Selections (A or B)
OneWireless R2xx represents the previous releases whereas R3xx is the current release. A OneWireless system with R3xx
firmware can host R2xx and R3xx devices. Please select the option to match the targeted OneWireless system.


Remote Antenna and Cables (M or D)
The user can select one of the optional remote antennas listed. The selection of the antenna option automatically includes
the remote antenna adapter.
To complete the option selection, one of the remote antenna cables (1, 2, or 3) must also be selected.


Lightning (Surge) Diverter and Cables (1, 2, or 3)
The lightning surge diverter options includes the surge diverter and cable. The diverter features Type N connections
(female) on both ends. The remote antenna adapter is not included.


Remote Antenna Adapter (A)
This option provides an adapter to be inserted into the opening where the integral antenna normally connects. The adapter
is designed to connect to a remote antenna that the user supplies. It features a female Type N connection.


Standard Diagnostics plus Anti-Alias Filter (3)
This option enables the Anti-Alias filter option which attenuates the higher frequencies and helps to prevent aliasing
components from being sampled.


Destination Country (CA, EU, or US)
This selection sets the transmission power at the factory to comply with the installation country location.


Custom Configuration (C)
Customer specified configuration parameters are programmed into the transmitter at the factory. Configuration information
needs to be communicated to Honeywell Order Management at time of order entry.
Additionally, the Honeywell OneWireless user interface is accessible through any browser and thus all configurable
parameters are visible and can be edited.


Custom Calibration (B)
Custom calibration would input customer specified LRV and URV values, and check linearity. LRV and URV information
needs to be communicated to Honeywell Order Management at time of order entry.


Mounting Brackets (1, 3, 5, or 7)
The angle mounting bracket is available in either zinc-plated carbon steel or 316 stainless steel and is suitable for horizontal
or vertical mounting on a two-inch (50 millimeter) pipe, as well as wall mounting.


An additional flat mounting bracket is also available in carbon steel and 316 stainless steel for two-inch (50 millimeter) pipe
mounting.


Tagging (Option 1 or 2)
The choice of 1 or 2 stainless steel wired-on tags is available. Each tag can accommodate additional data of up to 4 lines of
28 characters. The number of characters includes spaces.
Note that the standard nameplate on the meter body contains the serial number and body-related data.


Sales and Service
For application assistance, current specifications, ordering, pricing, and name of the nearest Authorized Distributor,
contact one of the offices below.


ASIA PACIFIC                           EMEA                                      AMERICAS
Honeywell Process Solutions,           Honeywell Process Solutions,              Honeywell Process Solutions,
Phone: + 800 12026455 or               Phone: + 800 12026455 or                  Phone: (TAC) (800) 423-9883
+44 (0) 1202645583                     +44 (0) 1202645583                        or (215) 641-3610
(TAC) hfs-tac-                                                                   (Sales) 1-800-343-0228
support@honeywell.com
                                       Email: (Sales)                            Email: (Sales)
Australia                              FP-Sales-Apps@Honeywell.com               FP-Sales-Apps@Honeywell.com
Honeywell Limited
Phone: +(61) 7-3846 1255               or                                         or
FAX: +(61) 7-3840 6481                 (TAC)                                     (TAC)
Toll Free 1300-36-39-36                hfs-tac-support@honeywell.com             hfs-tac-support@honeywell.com
Toll Free Fax:
1300-36-04-70

China – PRC - Shanghai
Honeywell China Inc.
Phone: (86-21) 5257-4568
Fax: (86-21) 6237-2826

Singapore
Honeywell Pte Ltd.
Phone: +(65) 6580 3278
Fax: +(65) 6445-3033

South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799 6114
Fax: +(822) 792 9015




For more information
To learn more about SmartLine Transmitters,
visit www.honeywellprocess.com
Or contact your Honeywell Account Manager


Process Solutions
Honeywell
1250 W Sam Houston Pkwy S
Houston, USA, TX 77042

Honeywell Control Systems Ltd
Honeywell House, Skimped Hill Lane
Bracknell, England, RG12 1EB

Shanghai City Centre, 100 Jungi Road
Shanghai, China 20061                               34-SW-03-01
                                                    June 2018
                                                    2018 Honeywell International Inc.
www.honeywellprocess.com



Document Created: 2018-07-05 16:23:01
Document Modified: 2018-07-05 16:23:01

© 2024 FCC.report