MPE

FCC ID: S3CDB6MR20

RF Exposure Info

Download: PDF
FCCID_1069653

EUT: Dual Band Indoor Repeater                          FCC ID: S3CDB6MR20 Model: DB6MR20
                                                                       Report Number: 0048-090112-01


Section 11. Maximum Permissible Exposure

 MPE estimate is given per 2.1091 of FCC Rules:
 Calculation Equation:

                    P +G
                     20
               10
 d = 0.282 ×
                    S

 Where, P(DL)= 19.3 dBm, G=9 dBi (max. Indoor Server Antenna, GP(UL)= 20.8dBm, G=12 dBi
 (Donor Antenna), and from §1.1310 Table 1 (B), S = 0.55 mW/cm2

 Plug all three items into the equation, and yields,

                            Output       Server                  Server MPE
  Power Density                                       Donor                         Donor MPE
                            Power       Antenna                   Distance
    MPE Limit                                        Antenna                         Distance
                            (dBm)      Gain (dBi)                   (cm)
    (mW/ cm2)                                       Gain (dBi)                         (cm)
                            DL/UL

        0.55               19.3/20.8       9           12             10               16.6



NOTE:

For mobile or fixed location transmitters, the minimum separation distance is
20 cm, even if calculations indicate that the MPE distance would be less.




                                          Page 193 of 208
  Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288



Document Created: 2009-02-11 21:39:18
Document Modified: 2009-02-11 21:39:18

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC