MPE

FCC ID: S3CBTSLINK-208

RF Exposure Info

Download: PDF
FCCID_964142

EUT: BTS Link-208 Repeater                                       FCC ID: S3CBTSLINK-208 Model: 208
                                                                     Report Number: 0048-080415-01


Section 11. Maximum Permissible Exposure

 MPE estimate is given per 2.1091 of FCC Rules:
 Calculation Equation:

                    P +G

               10    20
 d = 0.282 ×
                    S

 Where, P(DL)= 33.3 dBm, G=9 dBi (max. Indoor Server Antenna)/16dBi (max. Outdoor Server
 Antenna), and from §1.1310 Table 1 (B), S = 0.55 mW/cm2


 Plug all three items into the equation, and yields,

                           Output     Server                   Server MPE
  Power Density                                    Donor                           Donor MPE
                           Power     Antenna                    Distance
    MPE Limit                                     Antenna                           Distance
                           (dBm)    Gain (dBi)                    (cm)
    (mW/ cm2)                                    Gain (dBi)                           (cm)
                           DL/UL      In/Out                     In/Out

       0.55                33.3/-     9/16             -       50.1/112.1               -


NOTE: No UL link antenna presents.

For mobile or fixed location transmitters, the minimum separation distance is
20 cm, even if calculations indicate that the MPE distance would be less.




                                            Page 161
  Advanced Compliance Laboratory, Inc. 6 Randolph Way, Hillsborough, NJ 08844, Tel: (908) 927 9288



Document Created: 2008-06-08 21:10:17
Document Modified: 2008-06-08 21:10:17