Test Report

FCC ID: S29TALI-H500

Test Report

Download: PDF
FCCID_2374266

                  SLG Asia Test Labs & Service (HK) Limited




                                Test Report
                                            According to

                                  FCC PART 15 Subpart C

                                       FCC ID: S29TALI-H500




                   Test Report Number: H1M21407-2065-P-15




SLG Asia Test Labs & Service (HK) Limited
26/F., Tamson Plaza, 161 Wai Yip Street                       Phone   +852 2389 2200
Kwun Tong, Kowloon, Hong Kong                                 Fax     +852 2389 3073


        SLG Asia Test Labs & Service (HK) Limited

                                                    TEST REPORT
                                                    Summary | FCC Part 15C
Test Report No. ......................... :         H1M21407-2065-P-15
Date of issue.............................. :       27.08.2014


Testing Laboratory name ....... :                   SLG Asia Test Labs & Service (HK) Limited
Address...................................... :     26/F., Tamson Plaza, 161 Wai Yip Street,
                                                    Kwun Tong, Kowloon, Hong Kong
Applicant’s name ..................... :            GuangZhou Walkera Technology Co., Ltd
Address...................................... :     Taishi Industrial Park, Dongchong Town, Nansha District, 511475
                                                    Guangzhou, China
Manufacturer’s name ............. :                 GuangZhou Walkera Technology Co., Ltd
Address...................................... :     Taishi Industrial Park, Dongchong Town, Nansha District, 511475
                                                    Guangzhou, China
Test specification
Standard(s) applied ................... :           FCC Rules 47 CFR Part 15 Subpart C
Test item description .............. :              R/C Helicopter with GPS
Brand Name .............................. :         devention, WALKERA
Model and/or type reference...... :                 TALI-H500
Rating(s) .................................... :    22.2V, 5400mAh (rechargeable Li-Po battery)


Summary of Test Results                                                                Pass

The Summary of Test Results based on a technical opinion belongs to the applied standard(s).

Disclaimer
Further details of testing are provided in particular chapters of this Test Report.
This document base on General Terms and Conditions of SLG Asia Test Labs & Service (HK) Limited, which the applicant accepted
with order confirmation.

Emphasized conditions or project related conditions:
Released Test Reports apply only to the specific samples tested under stated test conditions. It is the applicant’s responsibility to
assure that additional production units of the tested model(s) are manufactured in same construction and with identical electrical and
mechanical components to meet the same quality as tested model(s). The applicant/manufacturer/importer is responsible for any
modifications made to the production units which result in non-compliance to the applied and/or relevant regulations.
SLG Asia Test Labs & Service (HK) Limited shall have no liability for any deductions, inferences or generalizations drawn by the client
or others from any kind of issued reports. Reports are confidential property of the client. As a mutual protection to the applicant, the
clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval.




                                                   Test Report No.: H1M21407-2065-P-15
                                              SLG Asia Test Labs & Service (HK) Limited
                         26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong                        Page 1 of 20


       SLG Asia Test Labs & Service (HK) Limited

TABLE OF CONTENTS
1        General Information                                                               3

1.1         Test Report                                                                    3

1.2         Test Location                                                                  4

1.3         Details of applicant                                                           4

1.4         Manufacturer                                                                   4

1.5         Application details                                                            5

1.6         Test item                                                                      5

1.7         General Test Conditions                                                        6

2        Test result Summary                                                               7

3        Test results                                                                      8

3.1.        6dB Bandwidth                                                                  8

3.2.        Output power                                                                   10

3.3.        Power Spectral Density                                                         11

3.4.        Out-of-band Emission                                                           12

3.5.        Band edge requirement                                                          16

3.6.        Receiver radiated emission                                                     18

4        Normative references                                                              19

5        Disclaimer                                                                        20

5.1         Revision Notes                                                                 20

Annex: A – Photos of test item                                           Number of Pages       4

Annex: B – External Photos of test item                                  Number of Pages    11

Annex: C – Internal Photos of test item                                  Number of Pages       1




                                    Test Report No.: H1M21407-2065-P-15
                                   SLG Asia Test Labs & Service (HK) Limited
                 26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong    Page 2 of 20


       SLG Asia Test Labs & Service (HK) Limited


1      General Information




1.1    Test Report




Tested by:

27.08.2014                          Mr. Karl Lau


Date                                Test Engineer                                       Signature




Approved by:

27.08.2014                          Mr. F. Schulz


Date                             Laboratory Manager                                     Signature




                               Test Report No.: H1M21407-2065-P-15
                             SLG Asia Test Labs & Service (HK) Limited
               26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong         Page 3 of 20


      SLG Asia Test Labs & Service (HK) Limited


1.2    Test Location

All tests were carrying by personnel from:

Name:          SLG Asia Test Labs & Service (HK) Limited
Address:       26/F., Tamson Plaza, 161 Wai Yip Street
               Kwun Tong, Kowloon, Hong Kong

Telephone:     +852 2389 2200
Fax:           +852 2389 3073


The Test facility for radiated measurements is located at:

Name :         Hong Kong Productivity Council
Address:       EMC Centre, LG1, HKPC Building, 78 Tat Chee Avenue
               Kowloon, Hong Kong

The Hong Kong Laboratory Accreditation Scheme (HOKLAS)
Reg. No.082

FCC registered measurement facility
Reg. No.90656


1.3    Details of applicant

Name:          GuangZhou Walkera Technology Co., Ltd
Address:       Taishi Industrial Park, Dongchong Town, Nansha District
               511475 Guangzhou, China

Contact:       Mr. Ya
Telephone:     +86-020-84915116
Fax:           +86-020-84915117


1.4    Manufacturer

Name:          GuangZhou Walkera Technology Co., Ltd
Address:       Taishi Industrial Park, Dongchong Town, Nansha District
               511475 Guangzhou, China

Contact:       Mr. Ya
Telephone:     +86-020-84915116
Fax:           +86-020-84915117




                                 Test Report No.: H1M21407-2065-P-15
                               SLG Asia Test Labs & Service (HK) Limited
                 26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong   Page 4 of 20


       SLG Asia Test Labs & Service (HK) Limited


1.5     Application details

Date of receipt of application:                22.07.2014
Date of receipt of test item:                  22.07.2014
Date (s) of performance of tests:              22.07.2014    - 27.08.2014



1.6     Test item


Description of test item:              R/C Helicopter with GPS
Type identification:                   TALI-H500
Brand Name:                            devention, WALKERA

Equipment category:                    Non Specific SRD DSSS transceiver
Equipment classification:              Portable use
Permitted frequency range:             2400 – 2483.5 MHz
Operation frequency range:             2400 – 2479 MHz (2.4GHz DSSS Transceiver)
Lowest Operation frequency:            2405 MHz
Middles Operation frequency:           2441 MHz
Highest Operation frequency:           2479 MHz
Emission designator:                   F7D
Antenna gain:                          ≤ 0 dBi
Type of modulation:                    DSSS
Operation mode:                        simplex
Type of antenna:                       integral
Power supply:                          22.2V, 5400mAh (rechargeable Li-Po battery)
2.4G Transceiver Module:               RX705

All information was provided by the applicant)

Test Configuration:

       Part Name                              Description                           Tested configuration
       TALI H500                    Hexacopter base with 6 motors                             
       FCS-H500                             Main controller                                   
        RX705                        2.4GHz transceiver module                                
         GPS                                 GPS receiver                                     
      G-3D gimbal                    Controller with camera holder                            
      DEVO F12E                       Remote control with video                     For function test only
        iLook+                         5.8GHz camera module                             Not included




                                     Test Report No.: H1M21407-2065-P-15
                                    SLG Asia Test Labs & Service (HK) Limited
                    26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong        Page 5 of 20


      SLG Asia Test Labs & Service (HK) Limited


1.7     General Test Conditions

Environmental reference conditions

If not defined otherwise by the Technical Committee responsible for the generic standard and/or the product
standard the climatic conditions during the tests are to be within the limits specified by the manufacturer for
the operation of the EUT and the test equipment.

The climatic conditions during the tests were within the following limits:

           Temperature                              Humidity                       Atmospheric pressure
           15 °C - 35 °C                           30 % - 60 %                      860 hPa - 1060 hPa

If explicitly required in the test base (basic) the climatic values are recorded and documented separately for
the respective test.

Calibration of measurement and test equipment

All measurement and testing equipment that has a significant influence on the accuracy of qualitative
measurements and tests is subject to a periodical in-house system of calibration and servicing that is part of
the quality management system of the EMC laboratory of SLG Asia Test Labs & Service (HK) Limited.

Measurement uncertainties

All tests are subject to measurement uncertainties. The overall measurement uncertainty of a measurement
is defined as the range of which can be supposed that it contains the true value with a specified probability.
This probability is 95 % for the generally specified measurement uncertainty (so-called expanded
measurement uncertainty).
The limits for emission measurements and the test levels for immunity tests in the applied standards were
defined taking into consideration the accuracy limits for measurement and testing equipment required by the
basic standards.
All measurement and test results of the EMC laboratory of SLG Asia Test Labs & Service (HK) Limited fulfil
the requirements for measurement uncertainties according to the standards applied.




                                    Test Report No.: H1M21407-2065-P-15
                                  SLG Asia Test Labs & Service (HK) Limited
                   26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong         Page 6 of 20


         SLG Asia Test Labs & Service (HK) Limited


2        Test result Summary


Digital Transmission system (2400-2483.5MHz)

Requirements according standard:

    FCC Rule          Test description                Results/Notes              Limits/Requirements        Verdict

15.247(a)         Digital modulation         System uses DSSS techniques                                       P

15.247(a)
(2)
                  6dB Bandwidth              > 888KHz                          > 500kHz                        P

15.247(b)                                    14.58dBm (EIRP)
(3)
                  Maximum peak Power
                                              (28.71 mW)
                                                                               1W, EIRP limited to 4W          P

15.247(e)         Power Spectral Density     -1.75dBm/3kHz                     < 8dBm/3kHz                     P

15.247(d) /       Out-of-band Emission                                         15.209, 15.205 restricted
15.209, 15.205    30MHz – 25GHz
                                             All signals below Limits
                                                                               bands, all others < -20dBc
                                                                                                               P

                  Band-edge requirements                                       Within range 2400-
15.247(d)
                  in 100kHz Bandwidth
                                             All frequencies inside the band
                                                                               2483.5MHz
                                                                                                               P

                  Radiated Emission
15.B
                  For Receiver part
                                             All signals below Limits          15.109                          P

15.203            Antenna requirements       EUT has integral antenna                                          P
                                             Exemption of RF Exposure
15.247 (b)/       RF Exposure
15.407 (f)        requirements
                                             evaluation. Please refer to       Refer to OET 65                 P
                                             attached statement




Test case verdicts

  P      - Pass                Test item does meet the requirement
  F      - Fail                Test item does not meet the requirement
N.A.     - Not Applicable      Test case does not apply to the test object




                                       Test Report No.: H1M21407-2065-P-15
                                   SLG Asia Test Labs & Service (HK) Limited
                     26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong         Page 7 of 20


        SLG Asia Test Labs & Service (HK) Limited


3        Test results

3.1.     6dB Bandwidth
Test requirement:          FCC Rules 47 CFR Part 15 Subpart C
Test method:               15.247 clause (a) (2)
Tested by:                 Mr. Karl Lau
Operating Environment:     25 °C, 50 %, 990 hPa
EUT operation:             Transmitting in selected channel (worst case)
Tested model:              TALI-H500

Measurement Equipment Used:

                                                                                                        Cal Interval
ID No.     Test equipment        Type          Manufacturer            Cal Date       Cal Due Date
                                                                                                          (year)
 E113     Spectrum Analyzer      FSL6        Rohde & Schwarz         26 Aug 2014       26 Aug 2015            1

Measurement Results:

FCC part 15.247 (a) (2): Signal Bandwidth

         Frequency            Resolution bandwidth              6dB bandwidth                   Limit       Verdict
            MHz                        kHz                           kHz                        kHz
            2405                       100                          898.00                      >500         Pass
            2441                       100                          888.00                      >500         Pass
            2479                       100                          938.00                      >500         Pass

Lowest Operation frequency:              2405 MHz


                            Offs 17.00 dB      * RBW 100 kHz
                            Att 25 dB          * VBW 300 kHz   M1[1]              - 5.64 dBm
                            Ref 20.00 dBm        SWT 2.5ms                  2.404531000 GHz
                                                               M2[1]              - 0.46 dBm
                         1Pk                                                2.405309000 GHz
                             10 dBm
                         Max                                   D3[1]                - 0.60 dB
                                                               M2         898.000000000 kHz
                              0 dBm                   M1
                                                                D3
                                     D1 -6.000 dBm
                              -10 dBm


                              -20 dBm

                              -30 dBm


                              -40 dBm


                              -50 dBm


                              -60 dBm


                              -70 dBm



                            CF 2.405 GHz                                     Span 5.0 MHz




                                        Test Report No.: H1M21407-2065-P-15
                                  SLG Asia Test Labs & Service (HK) Limited
                  26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong                Page 8 of 20


      SLG Asia Test Labs & Service (HK) Limited

Middles Operation frequency:          2441 MHz



                           Offs 14.00 dB    * RBW 100 kHz
                           Att 25 dB        * VBW 300 kHz        M1[1]           - 6.43 dBm
                           Ref 17.00 dBm      SWT 2.5ms                    2.440531000 GHz
                                                                 M2[1]           - 0.28 dBm
                       1Pk 10 dBm                                          2.441319000 GHz
                       Max                                       D3[1]
                                                                 M2                 0.41 dB
                           0 dBm                                         888.000000000 kHz
                                                   M1             D3
                                  D1 -6.000 dBm
                           -10 dBm


                           -20 dBm

                           -30 dBm


                           -40 dBm


                           -50 dBm


                           -60 dBm


                           -70 dBm


                           -80 dBm

                           CF 2.441 GHz                                     Span 5.0 MHz




Highest Operation frequency:          2479 MHz


                           Offs 16.00 dB    * RBW 100 kHz
                           Att 25 dB        * VBW 300 kHz        M1[1]           - 6.09 dBm
                           Ref 19.00 dBm      SWT 2.5ms                    2.478511000 GHz
                                                                 M2[1]            0.17 dBm
                       1Pk 10 dBm                                          2.478970000 GHz
                       Max                                       D3[1]             - 0.11 dB
                                                            M2
                                                                         938.000000000 kHz
                           0 dBm
                                                   M1
                                                                  D3
                                  D1 -6.000 dBm
                           -10 dBm

                           -20 dBm


                           -30 dBm


                           -40 dBm


                           -50 dBm


                           -60 dBm

                           -70 dBm



                           CF 2.479 GHz                                     Span 5.0 MHz




                                     Test Report No.: H1M21407-2065-P-15
                                SLG Asia Test Labs & Service (HK) Limited
                 26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong        Page 9 of 20


        SLG Asia Test Labs & Service (HK) Limited


3.2.     Output power
Test requirement:        FCC Rules 47 CFR Part 15 Subpart C
Test method:             15.247 clause (b) (3)
Tested by:               Mr. Karl Lau
Operating Environment:   25 °C, 50 %, 990 hPa
EUT operation:           Transmitting in selected channel (worst case)
Tested model:            TALI-H500

Measurement Equipment Used:

                                                                                                  Cal Interval
ID No.    Test equipment       Type       Manufacturer            Cal Date        Cal Due Date
                                                                                                    (year)
 E113     Spectrum Analyzer    FSL6     Rohde & Schwarz       26 Aug 2014         26 Aug 2015           1

Measurement Results:

FCC part 15.247 (b) (3): Output Power

                                          Antenna
Frequency         Output Power                                     EIRP              EIRP Limit      Verdict
                                           Gain
   MHz          dBm            mW           dBi           dBm              mW             W
   2405         14.58         28.71          0            14.58           28.71           4           Pass
   2441         14.42         27.67          0            14.42           27.67           4           Pass
   2479         10.73         11.83          0            10.73           11.83           4           Pass

All results were measured with peak power meter.




                                  Test Report No.: H1M21407-2065-P-15
                                SLG Asia Test Labs & Service (HK) Limited
                 26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong          Page 10 of 20


        SLG Asia Test Labs & Service (HK) Limited

3.3.     Power Spectral Density
Test requirement:        FCC Rules 47 CFR Part 15 Subpart C
Test method:             15.247 clause (e)
Tested by:               Mr. Karl Lau
Operating Environment:   25 °C, 50 %, 990 hPa
EUT operation:           Transmitting in selected channel (worst case)
Tested model:            TALI-H500

Measurement Equipment Used:

                                                                                                Cal Interval
ID No.     Test equipment      Type       Manufacturer          Cal Date       Cal Due Date
                                                                                                  (year)
 E113     Spectrum Analyzer    FSL6     Rohde & Schwarz       26 Aug 2014      26 Aug 2015            1

Measurement Results:

FCC part 15.247 (e): Power spectral Density

         Frequency                  PSD                         Limit                        Verdict
            MHz                   dBm/3kHz                    dBm/3kHz
            2405                    -1.75                         8                           Pass
            2441                    -1.89                         8                           Pass
            2479                    -4.41                         8                           Pass

Note 1: Power spectral density measured using RBW=3kHz, VBW=10kHz, analyzer with peak detector and
        with a sweep time set to ensure a dwell time of at least 1 second per 3kHz. The measurement is
        made at the frequency of PSD determined from preliminary scans using




                                  Test Report No.: H1M21407-2065-P-15
                                SLG Asia Test Labs & Service (HK) Limited
                 26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong        Page 11 of 20


        SLG Asia Test Labs & Service (HK) Limited

3.4.    Out-of-band Emission

Test requirement:        FCC Rules 47 CFR Part 15 Subpart C
Test method:             15.247 clause (d)
Tested by:               Mr. Karl Lau
Operating Environment:   25 °C, 50 %, 990 hPa
EUT operation:           Transmitting in selected channel (worst case)
Tested model:            TALI-H500

Measurement Equipment Used:

                                                                                   Cal Due      Cal Interval
  No.          Test equipment          Type      Manufacturer       Cal Date
                                                                                    Date          (year)
             10m Semi-anechoic
EMC209                                   Nil       Frankonia        12 Apr 14      12 Apr 15         1
                 Chamber
                                        ESU        Rohde &
EMC567          Test Reciever                                       5 Jan 14       5 Jan 15          1
                                         26        Schwarz
                                                   Rohde &
EMC577        Bi-conical Antenna       HK116                        5 May 14       5 May 15          1
                                                   Schwarz
                                                   Rohde &
EMC045      Log.-Periodic Antenna      HL223                        6 May 14       6 May 15          1
                                                   Schwarz

Measurement Procedure




The equipment under test is placed on a non metallic table with 0.8 m height.
The power supply and the RF connection points are close to the equipment under test at the floor inside a
connection box. The cables to this connection box are shielded and below the double floor. The receiving
antenna is placed in a height at 1.0 m to 4.0 m and in a distance of 3 m.




                                   Test Report No.: H1M21407-2065-P-15
                                SLG Asia Test Labs & Service (HK) Limited
                 26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong        Page 12 of 20


      SLG Asia Test Labs & Service (HK) Limited
Measurement Results:

Low Frequency @ 2405 MHz

     Fundamental emission level @3m in 100khz RBV                            109.81            dBV/m
      Limit for emission outside of restricted bands:                         89.81            dBV/m
   Frequency             Level            Pol           15.209/15.247          Detector        Comments
      MHz               dBV/m           V/H           Limit        Margin Pk/QP/Avg
     143.788             36.76             V           89.81         53.05          Pk           RB/VB 100kHz
     160.140             38.89             H           89.81         50.92          Pk           RB/VB 100kHz
     400.401             35.04             V             46          10.96          Pk           RB/VB 100kHz
     240.080             36.76             H             46           9.24          Pk           RB/VB 100kHz
      4810               37.25             V             54          16.75          Avg           RB/VB 1MHz
      4810               37.37             H             54          16.63          Avg           RB/VB 1MHz
      7215               41.97             V             54          12.03          Pk            RB/VB 1MHz
      7215               50.98             H             54           3.02          Pk            RB/VB 1MHz
      9620               44.45             V           89.81         45.36          Pk            RB/VB 1MHz
      9620               41.71             H           89.81         48.10          Pk            RB/VB 1MHz
For emission in restricted band, the limit of 15,209 was used. For all other emission, the limit was set 20dB
below the level of fundamental and measured in 100kHz

Middle Frequency @ 2441 MHz

    Fundamental emission level @3m in 100khz RBV                           109.65             dBV/m
     Limit for emission outside of restricted bands:                        89.65             dBV/m
   Frequency             Level           Pol           15.209/15.247          Detector        Comments
      MHz              dBmV/m           V/H           Limit       Margin       Pk/QP/Avg
    143.788              36.96            V           89.65        52.69           Pk            RB/VB 100kHz
    160.140              38.96            H           89.65        50.69           Pk            RB/VB 100kHz
    400.401              36.01            V           46.00         9.99           Pk            RB/VB 100kHz
    240.080              36.33            H           46.00         9.67           Pk            RB/VB 100kHz
      4882               36.48            V            54          17.52          Avg             RB/VB 1MHz
      4882               36.03            H            54          17.97          Avg             RB/VB 1MHz
      7323               46.35            V            54           7.65           Pk             RB/VB 1MHz
      7323               45.91            H            54           8.09           Pk             RB/VB 1MHz
      9764               40.17            V           89.65        49.48           Pk             RB/VB 1MHz
      9764               44.75            H           89.65        44.90           Pk             RB/VB 1MHz
For emission in restricted band. the limit of 15.209 was used. For all other emission. the limit was set 20dB
below the level of fundamental and measured in 100kHz




                                   Test Report No.: H1M21407-2065-P-15
                                 SLG Asia Test Labs & Service (HK) Limited
                  26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong        Page 13 of 20


      SLG Asia Test Labs & Service (HK) Limited

High Frequency @ 2479 MHz

   Fundamental emission level @3m in 100khz RBV                         105.96             dBV/m
    Limit for emission outside of restricted bands:                      85.96             dBV/m

  Frequency          Level           Pol             15.209/15.247         Detector        Comments
     MHz            dBmV/m           V/H           Limit       Margin      Pk/QP/Avg
   163.206           37.76            V             43.5         5.74          Pk             RB/VB 100kHz
   160.140           38.46            H            85.96        47.50          Pk             RB/VB 100kHz
   400.401           35.34            V              46         10.66          Pk             RB/VB 100kHz
   240.080           36.92            H              46          9.08          Pk             RB/VB 100kHz
     4958            34.47            V              54         19.53          Avg             RB/VB 1MHz
     4958            36.06            H              54         17.94          Avg             RB/VB 1MHz
     7437            45.86            V              54          8.14          Pk              RB/VB 1MHz
     7437            45.81            H              54          8.19          Pk              RB/VB 1MHz
     9916            37.20            V            85.96        48.76          Pk              RB/VB 1MHz
     9916            38.54            H            85.96        47.42          Pk              RB/VB 1MHz

For emission in restricted band the limit of 15.209 was used. For all other emission. the limit was set 20dB
below the level of fundamental and measured in 100kHz

Note: Testing is carried out with frequency rang 30MHz to the tenth harmonics which above 5th
Harmonics is close to the noise base even antenna close up to 1meter distance according the
measurement of ANSI C63.4. Emissions 20dB lower than the limit are not reported.




                                   Test Report No.: H1M21407-2065-P-15
                                 SLG Asia Test Labs & Service (HK) Limited
                  26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong         Page 14 of 20


      SLG Asia Test Labs & Service (HK) Limited

FCC Part 15. Subpart C. §15.209. Radiated Emission Limits



       Frequency of Emission                     Field strength                      Field Strength
              [MHz]                                  [V/m]                            [dBV/m]

                30 – 88                               100                                  40.0

              88 – 216                                150                                  43.5

             216 – 960                                200                                  46.0

             Above 960                                500                                  54.0


FCC Part 15. Subpart C. §15.205. Restricted bands of operation


          MHz                          MHz                             MHz                        GHz

      0.090 - 0.110               16.42 - 16.423                    399.9 - 410                4.5 - 5.15
     10.495 - 0.505            16.69475 - 16.69525                    608 - 614               5.35 - 5.46
     2.1735 - 2.1905           16.80425 - 16.80475                   960 - 1240              7.25 - 7.75
       4.125 - 4.128                25.5 - 25.67                    1300 - 1427               8.025 - 8.5
    4.17725 - 4.17775               37.5 - 38.25                   1435 - 1626.5               9.0 - 9.2
    4.20725 - 4.20775                 73 - 74.6                   1645.5 - 1646.5              9.3 - 9.5
       6.215 - 6.218                 74.8 - 75.2                    1660 - 1710               10.6 - 12.7
    6.26775 - 6.26825              108 - 121.94                   1718.8 - 1722.2           13.25 - 13.4
    6.31175 - 6.31225                123 - 138                      2200 - 2300              14.47 - 14.5
       8.291 - 8.294              149.9 - 150.05                    2310 - 2390              15.35 - 16.2
       8.362 - 8.366          156.52475 - 156.52525                2483.5 - 2500             17.7 - 21.4
    8.37625 - 8.38675              156.7 - 156.9                    2690 - 2900             22.01 - 23.12
    8.41425 - 8.41475           162.0125 - 167.17                   3260 - 3267              23.6 - 24.0
      12.29 - 12.293              167.72 - 173.2                    3332 - 3339               31.2 - 31.8
   12.51975 - 12.52025               240 - 285                     3345.8 - 3358             36.43 - 36.5
   12.57675 - 12.57725             322 - 335.4                     3600 - 4400
       13.36-13.41




                                   Test Report No.: H1M21407-2065-P-15
                                 SLG Asia Test Labs & Service (HK) Limited
                  26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong          Page 15 of 20


        SLG Asia Test Labs & Service (HK) Limited

3.5.     Band edge requirement

Test requirement:          FCC Rules 47 CFR Part 15 Subpart C
Test method:               15.247 clause (d)
Tested by:                 Mr. Karl Lau
Operating Environment:     25 °C, 50 %, 990 hPa
EUT operation:             Transmitting in selected channel (worst case)
Tested model:              TALI-H500

Measurement Equipment Used:

                                                                                                       Cal Interval
ID No.    Test equipment         Type          Manufacturer              Cal Date     Cal Due Date
                                                                                                         (year)
 E113    Spectrum Analyzer       FSL6         Rohde & Schwarz       26 Aug 2014        26 Aug 2015           1

Measurement Results:

  Frequency          Resolution bandwidth                       20 dB band edge              Limit        Verdict
     MHz                      kHz                                     kHz                    MHz
     2405                     100                                   2404.341               > 2400.0        Pass
     2479                     100                                   2480.158               < 2483.5        Pass


Lowest Operation frequency:              2405 MHz


                            Offs 17.00 dB       * RBW 100 kHz
                            Att 25 dB           * VBW 300 kHz    M1[1]            - 19.98 dBm
                            Ref 20.00 dBm         SWT 2.5ms                  2.404341000 GHz


                         1Pk
                             10 dBm
                         Max

                              0 dBm

                              -10 dBm
                                                           M1
                              -20 dBmD1 -20.000 dBm

                              -30 dBm


                              -40 dBm


                              -50 dBm


                              -60 dBm


                              -70 dBm
                                         F1

                            CF 2.405 GHz                                      Span 15.0 MHz




                                        Test Report No.: H1M21407-2065-P-15
                                  SLG Asia Test Labs & Service (HK) Limited
                26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong                Page 16 of 20


      SLG Asia Test Labs & Service (HK) Limited

Highest Operation frequency:           2479 MHz


                           Offs 16.00 dB     * RBW 100 kHz
                           Att 25 dB         * VBW 300 kHz   M1[1]        - 20.11 dBm
                           Ref 19.00 dBm       SWT 2.5ms             2.480168000 GHz


                       1Pk 10 dBm
                       Max
                            0 dBm


                            -10 dBm
                                                             M1
                            -20 dBmD1 -20.000 dBm


                            -30 dBm


                            -40 dBm


                            -50 dBm


                            -60 dBm


                            -70 dBm
                                                                        F1

                           CF 2.479 GHz                               Span 15.0 MHz




                                      Test Report No.: H1M21407-2065-P-15
                                SLG Asia Test Labs & Service (HK) Limited
                 26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong   Page 17 of 20


        SLG Asia Test Labs & Service (HK) Limited

3.6.    Receiver radiated emission
Test requirement:       Section 15.109
Test method:            ANSI C63.4 /2/
Test date:              27.08.2014
Tested by:              Mr. Karl Lau
Class:                  B
EUT operation           Receiver Test in on mode, according user manual

Measurement Equipment Used:

                                                                                               Cal Due        Cal Interval
  No.            Test equipment             Type        Manufacturer          Cal Date
                                                                                                Date            (year)
               10m Semi-anechoic
EMC209                                         Nil        Frankonia          12 Apr 14         12 Apr 15           1
                   Chamber
                                              ESU         Rohde &
EMC567            Test Reciever                                               5 Jan 14         5 Jan 15            1
                                               26         Schwarz
                                                          Rohde &
EMC577          Bi-conical Antenna         HK116                              5 May 14         5 May 15            1
                                                          Schwarz
                                                          Rohde &
EMC045        Log.-Periodic Antenna         HL223                             6 May 14         6 May 15            1
                                                          Schwarz

Measurement results

Calculation of test results:
Such factors like antenna factor and cable loss are already included in the provided measurement results.


                                     Frequenc        Worst case                                       Margin
Frequency range        Antenna                                         Limit         Detector                     Verdict
                                         y            Result                                         to Limit
                      direction       in MHz         in dBuV/m      in dBuV/m            PK/QP        in dB
30MHz-200MHz              V           143.788          37.05           43.5               Pk          6.45         Pass
30MHz-200MHz              H           160.140          38.91           43.5               Pk          4.59         Pass
 200MHz-1GHz              V           400.401          35.76            46                Pk          10.24        Pass
 200MHz-1GHz              H           240.080          36.25            46                Pk          9.75         Pass
  1GHz-4GHz               V            3970            36.24            54                Pk          17.76        Pass
  1GHz-4GHz               H            3994            36.92            54                Pk          17.08        Pass
  4GHz-8GHz               V            6982            41.24            54                Pk          12.76        Pass
  4GHz-8GHz               H            6974            41.23            54                Pk          12.77        Pass
8GHz-12.75GHz             V            11988           48.33            54                Pk          5.67         Pass
8GHz-12.75GHz             H            11579           47.86            54                Pk          6.14         Pass

Note: No (further) spurious emissions in the range 20 dB below the limit found.

 Limits (Section 15.109)


                    Frequency range                                                  Limit
                     30MHz - 88MHz                                            100uV/m (40dBuV/m)
                    88MHz - 216MHz                                           150uV/m (43.5dBuV/m)
                   216MHz - 960MHz                                            200uV/m (46dBuV/m)
                     Above 960MHz                                             500uV/m (54dBuV/m)



                                      Test Report No.: H1M21407-2065-P-15
                                    SLG Asia Test Labs & Service (HK) Limited
                    26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong                 Page 18 of 20


      SLG Asia Test Labs & Service (HK) Limited

4     Normative references

/1/   FCC Rules 47 CFR PART 15 Subpart: 2013
      Radio Frequency Devises

/2/   ANSI C63.4-2009
      Methods of Measurement of Radio-Noise Emission from Low-Voltage Electrical and
      Electronic Equipment in the Range of 9 kHz to 40 GHz




                                Test Report No.: H1M21407-2065-P-15
                              SLG Asia Test Labs & Service (HK) Limited
               26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong   Page 19 of 20


      SLG Asia Test Labs & Service (HK) Limited


5            Disclaimer

This document based on General Terms and Conditions of SLG Asia Test Labs & Service (HK) Limited
which the applicant accepted with order confirmation.

Emphasized conditions or project related conditions:

Released Test Reports apply only to the specific samples tested under stated test conditions. It is the
applicant’s responsibility to assure that additional production units of the tested model(s) are manufactured in
same construction and with identical electrical and mechanical components to meet the same quality as
tested model(s). The applicant/manufacturer/importer is responsible for any modifications made to the
production units which result in non-compliance to the applied and/or relevant regulations.

SLG Asia Test Labs & Service (HK) Limited shall have no liability for any deductions inferences or
generalizations drawn by the client or others from any kind of issued reports. Reports are confidential
property of the client as a mutual protection to the applicant the clients. The public and ourselves extracts
from the test report shall not be reproduced except in full without our written approval.

The purpose of conformity testing is to increase the probability of adherence to the essential requirements or
conformity specifications as appropriate. The complexity of the technical specifications means that full and
thorough testing is impractical for both technical and economic reasons. Furthermore there is no guarantee
that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any
guarantee that such a test sample will interact with other genuinely open systems. The existence of the tests
nevertheless provides the confidence that the test sample possesses the qualities as maintained and that its
performance generally conforms to representative cases of communications equipment.

The test results of this test report relate exclusively to the item tested as specified in clause 1.6 of this report.
The test report may only be reproduced or published in full.

Reproducing or publishing extracts of the report requires the prior written approval of
SLG Asia Test Labs & Service (HK) Limited.



5.1     Revision Notes

This revised Report replaces the all former Test Reports based on number H1M21407-2065-P-15. These
former Test Reports are not longer valid. Every Revision of the original report is recorded below and identified
by the ║ symbol beside the text.


Revision No.                    Revision
H1M21407-2065-P-15              Original Test Report




                                     Test Report No.: H1M21407-2065-P-15
                                   SLG Asia Test Labs & Service (HK) Limited
                   26/F., Tamson Plaza, 161 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong             Page 20 of 20



Document Created: 2014-09-01 13:49:32
Document Modified: 2014-09-01 13:49:32

© 2024 FCC.report