RF exposure report

FCC ID: RUZ-068

RF Exposure Info

Download: PDF
FCCID_3946546

Report On
RF Exposure Assessment of the
FCS
MCT-US/STD Tri-corr Touch Pro

FCC ID: RUZ-068




Document 75940615 Report 06 Issue 2   January 2018


                  TÜV SÜD Product Service, Octagon House, Concorde Way, Segensworth North,
                              Fareham, Hampshire, United Kingdom, PO15 5RL
                            Tel: +44 (0) 1489 558100. Website: www.tuv-sud.co.uk




REPORT ON                          RF Exposure Assessment of the
                                   FCS
                                   MCT-US/STD Tri-corr Touch Pro

                                   Document 75940615 Report 06 Issue 2

                                   January 2018


PREPARED FOR                       HWM-Water Ltd
                                   Llantarnam Park Way
                                   Cwmbran
                                   NP44 3AW
                                   United Kingdom

                                   On Behalf of:

                                   Fluid Conservation Systems
                                   502 TechneCenter Drive
                                   Suite B
                                   Milford
                                   OH 45150
                                   USA




PREPARED BY
                                   David Guyett-Smith
                                   Chief Safety Engineer - Technical Solutions




APPROVED BY
                                   Ryan Henley
                                   Authorised Signatory


DATED                                16 January 2018

             This report has been up-issued to Issue 2 to amend the applicant name.




Document 75940615 Report 06 Issue 2                                                          Page 1 of 12


                                                                   CONTENTS

Section                                                                                                                                        Page No

1         REPORT SUMMARY ................................................................................................................... 3
1.1       Introduction .................................................................................................................................... 4
1.2       Regional Requirements ................................................................................................................. 5
1.3       Product Information ....................................................................................................................... 6
1.3.1     Technical Description .................................................................................................................... 6
1.3.2     Supported Features ....................................................................................................................... 6
1.3.3     Antennas ........................................................................................................................................ 6
2         TEST DETAILS ............................................................................................................................ 8
2.1       Rationale for Assessment of the RF Exposure ............................................................................. 9
2.2       Test Result Details....................................................................................................................... 10
3         DISCLAIMERS AND COPYRIGHT............................................................................................ 11
3.1       Disclaimers and Copyright ........................................................................................................... 12




Document 75940615 Report 06 Issue 2                                                                                                           Page 2 of 12


                                         SECTION 1


                                      REPORT SUMMARY




                                RF Exposure Assessment of the
                                            FCS
                                MCT-US/STD Tri-corr Touch Pro




Document 75940615 Report 06 Issue 2                             Page 3 of 12


1.1     INTRODUCTION


        The information contained in this report is intended to show verification of the RF Exposure
        Assessment of the FCS MCT-US/STD Tri-corr Touch Pro to the requirements of the applied test
        specifications.

        Objective                         To perform RF Exposure Assessment to determine the
                                          Equipment Under Test's (EUT’s) compliance of the applied
                                          rules.
        Applicant                         HWM-Water Ltd

        Manufacturer                      FCS

        Manufacturing Description         Tri-corr Touch Pro

        Model Number(s)                   MCT-US/STD

        Test Specification/Issue/Date     CFR 47 Pt1.1310 (2016)




Document 75940615 Report 06 Issue 2                                                        Page 4 of 12


1.2     REGIONAL REQUIREMENTS

        The table below shows the regional requirements that are referenced in this test report. A full list
        of the requirements is shown in Annex A.

         Report Reference                                    Regional Requirement

         FCC                                                 CFR 47 Pt1.1310 (2016)




Document 75940615 Report 06 Issue 2                                                               Page 5 of 12


1.3     PRODUCT INFORMATION


1.3.1   Technical Description

        The Equipment under test was a FCS MCT-US/STD Tri-corr Touch Pro. A full technical
        description can be found in the manufacturer’s documentation.

        All reported calculations were carried out on the relevant information supplied for the MCT-
        US/STD Tri-corr Touch Pro to demonstrate compliance with the applied test specification(s). The
        sample assessed was found to comply with the requirements of the applied rules.


1.3.2   Supported Features

        The following radio access technologies and frequency bands are supported by the equipment
        under test.

         Radio Access Technology                            Land Mobile Station


         Frequency Band                                     438-472 MHz



1.3.3   Antennas

        The following antennas are supported by the equipment under test.

         No.                                Model                                 Gain(dBi)

         1                                  Not Specified                         5



        The wireless device described within this report has been shown to be capable of compliance
        with the basic restrictions related to human exposure to electromagnetic fields for both General
        Public and Occupational. The calculations shown in this report were made in accordance with
        the procedures specified in the applied test specification(s).

         Required Compliance Boundary (m)

         Occupational                                       General Population

         0.10                                               0.21


                                                                Table 1 – Compliance Boundary Results




Document 75940615 Report 06 Issue 2                                                            Page 6 of 12


                          Calculated RF exposure level at compliance boundary of 0.10 m
         Regional
                          S Field (W/m2)                   E Field (V/m)                   H Field (A/m)
         Requirement
                          Result           Limit           Result            Limit         Result           Limit

         FCC*             1.2583           1.4600          N/A               N/A           N/A              N/A
                                               2
        * Requirement and Result in mW/cm

                                                                                   Table 2 – Occupational Results

        The calculations show that the EUT complies with the occupational exposure levels described in
        the and CFR 47 Pt1.1310 (2016) at the point of investigation, 0.10 m.

                          Calculated RF exposure level at compliance boundary of 0.21 m
         Regional
                          S Field (W/m2)                   E Field (V/m)                   H Field (A/m)
         Requirement
                          Result           Limit           Result            Limit         Result           Limit

         FCC*             0.2853           0.2920          N/A               N/A           N/A              N/A
        * Requirement and Result in mW/cm2

                                                                           Table 3 – General Population Results

        The calculations show that the EUT complies with the general population exposure levels
        described in the and CFR 47 Pt1.1310 (2016) at the point of investigation, 0.21 m.




Document 75940615 Report 06 Issue 2                                                                        Page 7 of 12


                                       SECTION 2


                                      TEST DETAILS




Document 75940615 Report 06 Issue 2                  Page 8 of 12


2.1     RATIONALE FOR ASSESSMENT OF THE RF EXPOSURE


        The aim of the assessment report is to evaluate the compliance boundary for a set of given input
        power according to the basic restrictions (directly or indirectly via compliance with reference
        levels) related to human exposure to radio frequency electromagnetic fields.
        The chosen assessment method to establish the compliance boundary in the far-field region is
        the reference method as defined in the relevant specifications.

        The RF exposure assessment is based upon the following criteria:

        The MCT-US/STD Tri-corr Touch Pro operates with the following transmitters active on the
        antenna ports shown in Section 1.3.3. For each transmitter, the Radio Access Technology (RAT),
        EIRP inclusive of antenna gain and duty cycle, gain of the antenna and lowest frequency of
        operation are shown as they contribute to the calculation of S Field, E field and H field values
        according to the following formulas.

        The power flux (S Field):

              PG( ,  )
         S
               4r 2
        The electric field strength (E Field):

                30 PG ( ,  )
         E
                    r
        The magnetic field strength (H Field):

               E
         H 
                  o




        Where:

        P = Average Power (W)
        G = Antenna Gain (dBi)
        r = Distance (cm) or (m)
        o = 377




Document 75940615 Report 06 Issue 2                                                           Page 9 of 12


2.2     TEST RESULT DETAILS

        The frequencies shown in the tables below have been chosen based on the lowest possible
        frequency that the EUT can transmit.

                                                                                    RF Exposure Level at compliance
                                                      Duty                          boundary of 0.10 m
         Antenna   Tx    Ant                 EIRP               Gain    Frequency
                               RAT                    Cycle
         Port      No.   No.                 (W)                (dBi)   (MHz)       S Field    E Field    H Field
                                                      (%)
                                                                                    (W/m2)     (V/m)      (A/m)

                               Land Mobile
         1         1     1                   1.581    100       5       438         12.5832    68.8748    0.1827
                               Station


                                                              Table 4 – Occupational Transmitter Summary

                                                                                    RF Exposure Level at compliance
                                                      Duty                          boundary of 0.21 m
         Antenna   Tx    Ant                 EIRP               Gain    Frequency
                               RAT                    Cycle
         Port      No.   No.                 (W)                (dBi)   (MHz)       S Field    E Field    H Field
                                                      (%)
                                                                                    (W/m2)     (V/m)      (A/m)

                               Land Mobile
         1         1     1                   1.581    100       5       438         2.8533     32.7975    0.0870
                               Station


                                                     Table 5 – General Population Transmitter Summary




Document 75940615 Report 06 Issue 2                                                                 Page 10 of 12


                                       SECTION 3


                               DISCLAIMERS AND COPYRIGHT




Document 75940615 Report 06 Issue 2                        Page 11 of 12


3.1     DISCLAIMERS AND COPYRIGHT




                         This report relates only to the actual item/items tested.

       This report must not be reproduced, except in its entirety, without the written permission of
                                      TÜV SÜD Product Service

                                   © 2018 TÜV SÜD Product Service




Document 75940615 Report 06 Issue 2                                                             Page 12 of 12


                                        ANNEX A


                                 REGIONAL REQUIREMENTS




Document 75940615 Report 06 Issue 2                      Page A.1 of A.2


                                                           Electric Field Strength   Magnetic Field Strength
         Frequency Range (MHz)   Power Density (mW/cm2)
                                                           (V/m)                     (A/m)

         0 - 0.3                 -                         -                         -

         0.3 - 3                 100                       614                       1.63

         3 - 30                  900/f^2                   1842/f                    4.89/f

         30 - 300                1                         61.4                      0.163

         300 - 1500              f/300                     -                         -

         1500 - 100000           5                         -                         -


                                               Table A.1 – CFR 47 Pt1.1310 (2016) Occupational Limits

                                                           Electric Field Strength   Magnetic Field Strength
         Frequency Range (MHz)   Power Density (mW/cm2)
                                                           (V/m)                     (A/m)

         0 - 0.3                 -                         -                         -

         0.3 - 3                 100                       614                       1.63

         3 - 30                  180/f^2                   824/f                     2.19/f

         30 - 300                0.2                       27.5                      0.073

         300 - 1500              f/1500                    -                         -

         1500 - 100000           1                         -                         -


                                          Table A.2 – CFR 47 Pt1.1310 (2016) General Population Limits




Document 75940615 Report 06 Issue 2                                                           Page A.2 of A.2



Document Created: 2018-01-16 13:44:06
Document Modified: 2018-01-16 13:44:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC