Test Report

FCC ID: RTQXID500

Test Report

Download: PDF
FCCID_3656606

                                                               Page 1 of 21                                Report No.: W17NR-D050




                            ELECTROMAGNETIC EMISSION
                               COMPLIANCE REPORT

         Test Report No.              : W17NR-D050

         AGR No.                      : A176A-395

         Applicant                    : LG CNS CO., LTD.

         Address                      : FKI Tower, 24, Yeoui-daero, Yeongdeungpo-gu, 07320, Seoul, South Korea

         Manufacturer                 : LG CNS CO., LTD.

         Address                      : FKI Tower, 24, Yeoui-daero, Yeongdeungpo-gu, 07320, Seoul, South Korea

         Type of Equipment            : RFID Card Reader

         FCC ID                       : RTQXID500

         Model Name                   : XID-500

         Multiple Model Name : N/A

         Serial number                : N/A

         Total page of Report : 21 pages (including this page)

         Date of Incoming             : July 11, 2017

         Date of Issuing              : November 16, 2017


         SUMMARY
         The equipment complies with the requirements of FCC CFR 47 PART 15 SUBPART C
         Section 15.225
         This test report contains only the result of a single test of the sample supplied for the examination.
         It is not a general valid assessment of the features of the respective products of the mass-production.




      Reviewed by:                                                            Approved by:
                          Ki-Hong, Nam / Asst, Chief Engineer                                  Keun-Young, Choi / Vice President
                          ONETECH Corp.                                                        ONETECH Corp.


It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


oneETECH
         N#                                                                 Page 2 of 21                                                 Report No.: W17NR—D050


                                                                              CONTENTS

                                                                                                                                                                             Page


1. VERIFICATION OF COMPLIANCE                                                                                                                                                       5


2. GENERAL INFORMATION                                                                                                                                                              6

  2.1 PRODUCT DESCRIPTION::. 2220000000000 00000000 n000 00e en n n n en n narenne n n en nnenennennennenarennenne en en nnennennennennennennnnennnnnnenennenne 6

  2.2 MODEL DIFFERENCES! a2.00.00.0000000000000 00e en rerennennnnenne n en n narennenne n en nnenennennennennrennennennennennnnnnennnnennennnnennnnnnennnenne 6

  2.3 RELATED SUBMITTAL(S) / GRANT(S) .. 22.00.0020.000.0000000000000000n0en0emernnnne en nnenennennenne en narennenne en nne en en en en en narennennennennenennennea 6

  2.4 PURPOSE OF THE TEST ... 2000000000000 00e n en en n n nnenn en n en revnnennennenennennennennrennennennnnennnnennennennnennennnnennennnnenennenne 6

  2.5 TEST METHODOLOGY :...2.20.00.00000 00000000000 n meneeennennnne en en en n narenennnennennennenennennennenarennenne en en nnennennennennennennnnennnnnnenennenne 6

  2.6 TEST FACILITY....                                                                                                                                                          27

3. SYSTEM TEST CONFIGURATION                                                                                                                                                        8

   3. 1 JJUSTIFICATION 12200000000 0000000000 00e n en n n n n en en n nnenn n nnenne n nnenennennnnenn en nnnnnnnnnnennennnnnnennennnnennenennennenne 8

   3.2 PERIPHERAL EQUIPMENT ..2.22.22.00.0.00.00.000u00000000e00en0 en en en en nnenenennennennennenne ennenneannarennnnenneaneaneaneanannnnnenneaneaneanenennennenne 8

   3.3 MODE OF OPERATION DURING THE TEST .......0..00.00.00.0000000000en0 en en en nnennnennnnennenne en en en en en en en narenne en nnnnennnennennenne 8

   3.4 EQUIPMENT MODIFICATIONS ....2..2.00.000e00e00e000e00e0 en en en en en neareneeneeneeneeneneeneeneeneeareeneeneeneeneeneeneeneeneenserseeneeneeneenenerneencene 8
   3.5 CONFIGURATION OF TEST SYSTEM .. 22.00.00.00000000000000 00e en0 en en en en en en en en en nnenn n en en en en en en en nnnnnnennnnennnennennenne 9

   3.6 ANTENNA REQUIREMENT ..2.22.22.00.0.00.00.000000000000000en0en0en0ennennnnenerennenneenennenne en ane en narenne en en en en en en enennvenne en en en enenennenneane 9


4. PRELIMINARY TEST                                                                                                                                                                 9

   4.1 AC POWER LINE CONDUCTED EMISSIONS TESTS...... 2200000000000 00000000 n0 en eennmare en en en en en en en en nnrenne en en en nnenennennenne 9

   4.2 RADIATED EMISSIONS TESTS.. ... 2220000000000 0000 en en n nare n en en en en en en en narenne en en en en en en nnnnnnenn en en nnnennennenne 9

5. FINAL RESULT OF MEASUREMENT                                                                                                                                                    10

   5.1 CONDUCTED EMISSION TEST ...

   5.2 RADIATED EMISSION TEST ........20000000e00000menenverververvenvennernvennennennennnnennennennennernnennennennennennennennennenneennennennennencnnennen 12
      5.2.1 Operation frequency band: (13.553 ~ 13.567) MHZ............socccsinsevirrirrrrsesennrrnsrenranrenrenrenranrenrennerennennennenennennena 12

      5.2.2 Operation frequency band: Below 13.553 MHz @nd @bOV€ 13.567 MHZ..................ccovsererrenrenrenrenreneinencens 13
   5.3 SPURIOUS EMISSION TEST ....2.00.00.00.000000000 0n ennrnernrenrenrnnrrenrenrenrenranenenrenrenrennenne en en en en en en en enennnennennennennenennenne 14
      5.3.1 SPUTiOUS R@di@ted EmMisSiON BEIOW 30 MEHZ .................ucoccsecenerrencnrrnrrnrrnrrrnrrnrrerrenrenrenrenrenrennerennennennennenennennen 14

      5.3.2 SPUTiOUS RQdiQted EMiSSHON D@IOW 1 GHZ.................locounenenrenrerreneerrenrerrnnrrnnrnnrenrnnrenrenrenrenennenerennennennennenennennen 15

   5.4 20 DB BANDWIDTEH .......2..22.00n00 0000000 en en reernvenvennennennennennennennee nernnennennennanennennennennnennennennennennennennennenneennennennennennencnnennen 16
      5.4. 1 ODEYAbIMQ GRVIPORIMNE..........c..c.clccculcecsevrenrensnsensensenrenernrennennennennenennennennnnvennennennennennennennennnnennnennennennnnenernvnnena 16

      5.4.2 TSb SOLUP «... 00 00iusoncenvnmenmennvnrennenrenerennennennennennennennennennennrennennennennen en nnennennennnennennennennenne en nnnnnnennnennennnnenernvnnena 16

      5.4.3 TSb AOLA ......c.0sucsoninnmennensensensenennennennennrennennennennennennennennennennrennennennennenennvnnvnnennennnennennennennennennennennenarennennennennennrnvnnena 17


Tt should not be reproduced except in full, withoutthe written approval of ONETECH Corp.                                                                       EMC—003 (Rev.2)
ONETECH Corp.: 43—14, Jinsaegol—gil, Chowol—eup, Gwangiu—si, Gyeonggi—do, 12735, Korea (TEL: 82—31—799—9500, FAX: 82—31—799—9599)


oneETECH
        N#                                                                   Page 3 of 21                                                  Report No.: W17NR—D050
   5.5 FREQUENCY STABILITY WITH TEMPERATURE VARIATION.                                                                                                                            .18
      5.5.1 ODePAbIMQ GRVIPORIMNE..........c..c.clccculcececerrensensnsensenrenernrennennennennenennnnennnnennennennennennennennennnnennnennennennnnenernvnnena 18

      5.5.2 TSb SOLUP «... 00 00iuoncenvnmenmennevnrennenrenerennennennennennennennennennennrennennennennen en nnennennennnennennennennenne en nnnnnnennnennennnnenernvnnena 18

      5.5.3 TSb AOBA ......csu00u00inssnmenmennensennevennennennennvennennennennennennennennennennnennennennennen en nnennennennnennennennennennennenne en nnrennennennennenernvnnena 18

   5.6 FREQUENCY STABILITY WITH VOLTAGE VARIATION.::..,.00.0.00.000000000000000en0en0ernrnrrnrenrennnrennrenrenenneenenennennes 19
      5.6.1 ODEPAbIMQ GRVIPORIMNE..........c..c.clccculceceverrensnsensensenreneensennennennennenennennennnnennennennennennennennennnnennnennennennnnenernvnnena 19

      5.6.2 TSb SOLUP «... c000iusonvenvnmenmennvnrennennenerennennennennennennennennennennnennennennennen en nnennennennnennennennennenne en nnnnnnennnennennnnenernvnnena 19

      5.6.3 TSb AOBM ......csucsu0sonisnmnnennensennevennennennennvennennennennennennennennennennnennennennennen en nnennennennnennennennennennennenne en nnrennennennennenernvnnena 19

6. FIELD STRENGTH CALCULATION                                                                                                                                                       20


7. LIST OF TEST EQUIPMENT                                                                                                                                                           21




Tt should not be reproduced except in full, withoutthe written approval of ONETECH Corp.                                                                         EMC—003 (Rev.2)
ONETECH Corp.: 43—14, Jinsaegol—gil, Chowol—eup, Gwangiu—si, Gyeonggi—do, 12735, Korea (TEL: 82—31—799—9500, FAX: 82—31—799—9599)


                                                                 Page 4 of 21                              Report No.: W17NR-D050


                                                        REVISION HISTORY

Issued Report No.      Issued Date               Revisions                                                               Effect Section

  W17NR-D050            November 16, 2017        Initial Issue                                                           All




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 5 of 21                                Report No.: W17NR-D050


1. VERIFICATION OF COMPLIANCE
-. APPLICANT                   : LG CNS CO., LTD.
-. ADDRESS                     : FKI Tower, 24, Yeoui-daero, Yeongdeungpo-gu, 07320, Seoul, South Korea
-. CONTACT PERSON              : TAE YOUNG, JEONG / Manager
-. TELEPHONE NO                : +82-2-2099-0165
-. FCC ID                      : RTQXID500
-. MODEL NO/NAME               : XID-500
-. SERIAL NUMBER               : N/A
-. DATE                        : November 16, 2017

 DEVICE TYPE                                               DXX – Low Power Communication Device Transmitter
 E.U.T. DESCRIPTION                                        RFID Card Reader
 THIS REPORT CONCERNS                                      Original Grant
 MEASUREMENT PROCEDURES                                    ANSI C63.10: 2013
 TYPE OF EQUIPMENT TESTED                                  Pre-Production
 KIND OF EQUIPMENT
                                                           Certification
 AUTHORIZATION REQUESTED
 EQUIPMENT WILL BE OPERATED
                                                           FCC CFR47 Part 15 Subpart C Section 15.225
 UNDER FCC RULES PART(S)
 MODIFICATIONS ON THE EQUIPMENT
                                                           None
 TO ACHIEVE COMPLIANCE
 FINAL TEST WAS CONDUCTED ON                               10 m Semi Anechoic Chamber

-. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules
   and Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels
   emanating from equipment are within the compliance requirements.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 6 of 21                                Report No.: W17NR-D050


2. GENERAL INFORMATION


2.1 Product Description
The LG CNS CO., LTD., Model XID-500 (referred to as the EUT in this report) is an RFID Card Reader, Product
specification information described herein was obtained from product data sheet or user’s manual.

  DEVICE TYPE                                    RFID Card Reader
  TRANSMITTING FREQUENCY                         13.56 MHz
  NUMBER OF CHANNELS                             1
  MODULATION                                     ASK
  ANTENNA TYPE                                   PCB Pattern Antenna
  LIST OF EACH OSC. or CRY.
                                                 27.12 MHz
  FREQ.(FREQ. >= 1 MHz)


2.2 Model Differences:
-. None

2.3 Related Submittal(s) / Grant(s)
Original submittal only


2.4 Purpose of the test
To determine whether the equipment under test fulfills the requirements of the regulation stated in FCC PART 15
SUBPART C Section 15.225.

2.5 Test Methodology
Both conducted and radiated testing was performed according to the procedures in ANSI C63.10: 2013. Radiate
d testing was performed at a distance of 3 m from EUT to the antenna.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 7 of 21                                Report No.: W17NR-D050

2.6 Test Facility
The Onetech Corp. has been designated to perform equipment testing in compliance with ISO/IEC 17025.
The Electromagnetic compatibility measurement facilities are located at 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si,
Gyeonggi-do, 12735, Korea
-. Site Filing:
VCCI (Voluntary Control Council for Interference) – Registration No. R-4112/ C-14617/ G-10666 / T-1842
IC (Industry Canada) – Registration No. Site# 3736A-3
-. Site Accreditation:
KOLAS (Korea Laboratory Accreditation Scheme) - Accreditation NO. KT085
FCC (Federal Communications Commission) - Accreditation No. KR0013
RRA (Radio Research Agency) – Designation No. KR0013




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 8 of 21                                Report No.: W17NR-D050


3. SYSTEM TEST CONFIGURATION

3.1 Justification
 This device was configured for testing in a typical way as a normal customer is supposed to be used. During the test, the
 following components were installed inside of the EUT.

     DEVICE TYPE                           MANUFACTURER                                MODEL/PART NUMBER                       FCC ID
        Main Board                                   N/A                              XID410_MAIN_PCB REV 06                        N/A
        Sub Board                                    N/A                            XID410_BOTTOM_BRD REV06                         N/A
        USB Board                                    N/A                                    XID400_RE0.6 USB SUB                    N/A
          Display                                    N/A                                            N/A                             N/A
      Antenna Board                                  N/A                               XID-400 Rev0.6 SUB Board                     N/A
          Adapter                 ShenZhen SOY Yechnology Co., Ltd                              SOY-1200300                         N/A


3.2 Peripheral equipment
Defined as equipment needed for correct operation of the EUT, but not considered as tested: None


3.3 Mode of operation during the test
-. The EUT has NFC and program was used for making continuous transmission mode for only NFC during the test.


3.4 Equipment Modifications
-. None




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 9 of 21                                 Report No.: W17NR-D050


3.5 Configuration of Test System

Line Conducted Test :                 The EUT was connected to LISN. All supporting equipments were connected to another
                                      LISN. Preliminary Power line Conducted Emission test was performed by using the
                                      procedure in ANSI C63.10: 2013 to determine the worse operating conditions.

Radiated Emission Test :              Preliminary radiated emissions test were conducted using the procedure in ANSI C63.10:
                                      2013 to determine the worse operating conditions. The radiated emissions measurements
                                      were performed on the 10 m Semi Anechoic Chamber.
                                      For frequencies from 150 kHz to 30 MHz measurements were made of the magnetic H field.
                                      The measuring antenna is an electrically screened loop antenna.
                                      The frequency spectrum from 30 MHz to 1 000 MHz was scanned and maximum emission
                                      levels maximized at each frequency recorded. The system was rotated 360°, and the antenna
                                      was varied in the height between 1.0 m and 4.0 m in order to determine the maximum
                                      emission levels. This procedure was performed for both horizontal and vertical polarization
                                      of the receiving antenna.


3.6 Antenna Requirement
For intentional device, according to section 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device.

Antenna Construction:
The transmitter antenna of the EUT is a PCB pattern antenna so there is no consideration of replacement by the user.

4. PRELIMINARY TEST

4.1 AC Power line Conducted Emissions Tests
During Preliminary Tests, the following operating mode was investigated
                         Operation Mode                                    The Worse operating condition (Please check one only)

                              Tx Mode                                                                   X


4.2 Radiated Emissions Tests
During Preliminary Tests, the following operating modes were investigated
                         Operation Mode                                    The Worse operating condition (Please check one only)

                              Tx Mode                                                                   X




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 10 of 21                               Report No.: W17NR-D050


5. FINAL RESULT OF MEASUREMENT
Preliminary test was done in normal operation mode. And the final measurement was selected for the maximized emission level.


5.1 CONDUCTED EMISSION TEST

Humidity Level           : (47 ~ 48) % R.H.                                                                    Temperature: (23 ~ 24) ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART B, SECTION 15.207(a)

Result                   : PASSED

EUT                      : RFID Card Reader                                                                    Date: November 01, 2017

Detector                 : CISPR Quasi-Peak (6 dB Bandwidth: 9 kHz)
Tested Line              : HOT LINE




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 11 of 21                               Report No.: W17NR-D050


Tested Line              : NEUTRAL LINE




Remark: Margin (dB) = Limit – Level (Result)
          The emission level in above table is included the transducer factor that means insertion loss (LISN),
          cable loss and attenuator.




                                                                                              Tested by: Tae-Ho, Kim / Manager




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 12 of 21                               Report No.: W17NR-D050


5.2 RADIATED EMISSION TEST


5.2.1 Operation frequency band: (13.553 ~ 13.567) MHz
The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.

Humidity Level           : 49.0 % R.H.                                                                         Temperature: 24.1 ºC
Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209
Type of Test             : Low Power Transmitter below 1 705 kHz

Result                   : PASSED

EUT                      : RFID Card Reader                                                                    Date: November 14, 2017

Operating Condition : Transmitting Mode

Detector                 : CISPR Quasi-Peak (6 dB Bandwidth: 9 kHz)

Distance                 :3m

      Radiated Emission                     Ant               Correction Factors              Total                      FCC
     Freq.           Amplitud                              Antenna              Cable       Amplitude           Limit           Margin
                                            Pol.
    (MHz)              (dBμV)                                (dB/m)              (dB)       (dBμV/m)         (dBμV/m)               (dB)

     13.56              17.99                H                19.98              1.09         39.06              124                84.94
     13.56              17.27                V                19.98              1.09         38.34              124                85.66
  Note: According to the distance of measurements was reduced to 3 m, the limit was extrapolated by using the square of
           an inverse linear distance extrapolation factor (40 dB/decade) as follows.
           Limit calculation: Limit at specified distance + 40log (30/3) = 84 dBμV/m + 40 dB




                                                                                              Tested by: Tae-Ho, Kim / Manager




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 13 of 21                               Report No.: W17NR-D050


5.2.2 Operation frequency band: Below 13.553 MHz and above 13.567 MHz
The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.

Humidity Level           : 49.0 % R.H.                                                                         Temperature: 24.1 ºC
Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209
Type of Test             : Low Power Transmitter below 1 705 kHz

Result                   : PASSED

EUT                      : RFID Card Reader                                                                    Date: November 14, 2017

Operating Condition : Transmitting Mode




cc. to above test data, the field strength level of 13.56 MHz is 17.99 dBuV/m and the worst limit subject to 15.225 (b) and
(c) is 80.5 dBuV/m, so the EUT meets the requirement.




                                                                                              Tested by: Tae-Ho, Kim / Manager



It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 14 of 21                               Report No.: W17NR-D050


5.3 SPURIOUS EMISSION TEST


5.3.1 Spurious Radiated Emission Below 30 MHz
Humidity Level           : (46 ~ 47) % R.H.                                                                    Temperature: (24 ~ 25) ºC
Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209
Type of Test             : Low Power Transmitter below 1 705 kHz

Frequency Range          : 9 kHz ~ 30 MHz

Result                   : PASSED

EUT                      : RFID Card Reader                                                                    Date: November 01, 2017

Operating Condition : Transmitting Mode

Distance                 :3m

Frequency Reading Ant. Pol. Ant.                            Angle     Ant. Factor       Cable      Emission     Limits              Margin
  (MHz)   (dBμV)   (H/V) Height (m)                          (°)       (dB/m)           Loss    Level(dBμV/m) (dBμV/m)               (dB)




                                            It was not observed any emissions from the EUT.




                                                                                                Tested by: Tae-Ho, Kim / Manager




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 15 of 21                               Report No.: W17NR-D050


5.3.2 Spurious Radiated Emission below 1 GHz
The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical.

Humidity Level           : (46 ~ 47) % R.H.                                                                    Temperature: (24 ~ 25) ºC
Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209
Type of Test             : Low Power Transmitter below 1 705 kHz

Frequency range          : 30 MHz ~ 1 000 MHz

Result                   : PASSED

EUT                      : RFID Card Reader                                                                    Date: November 01, 2017

Operating Condition : Transmitting Mode

Distance                 :3m




                                                                                              Tested by: Tae-Ho, Kim / Manager
It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 16 of 21                                    Report No.: W17NR-D050


5.4 20 dB BANDWIDTH


5.4.1 Operating environment
Temperature                          :       24.1 °C
Relative humidity                    :       49.0 % R.H.


5.4.2 Test set-up
The antenna output of the EUT was connected to the spectrum analyzer. The resolution bandwidth is set to 10 kHz, and
peak detection was used. The 20 dB bandwidth is defined as the total spectrum over which the power is higher than the peak
power minus 20 dB.




                             EUT                                                            Spectrum analyzer




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 17 of 21                               Report No.: W17NR-D050


5.4.3 Test data
-. Test Date                   : October 17, 2017

-. Limits apply to             : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209


   Operating Freq.                                                                            Assigned Operating
                                             Measured Value (kHz)                                                                   Result
         (MHz)                                                                               Frequency Band (kHz)

         13.56                                        165.03                                            900                         PASS




                                                                                              Tested by: Tae-Ho, Kim / Manager




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


onETECH
       NZ                                                      Page 18 of 21                               Report No.: W17NR—D050


5.5 FREQUENCY STABILITY WITH TEMPERATURE VARIATION


5.5.1 Operating environment
Temperature                           :      24.1 °C
Relative humidity                     :      49.0 % RH.


5.5.2 Test set—up
Turn EUT off and set chamber temperature to —20 °C and then allow sufficient time (approximately 20 to 30 minutes after
chamber reach the assigned temperature) for EUT to stabilize. Turn ON EUT and measure the EUT operating frequency
and then turn off the EUT after the measurement. The temperature in the chamber was raised 10 °C step from —20 °C to

+50°C. Repeat above method for frequency measurements every 10 °C step and then record all measured frequencies on
each temperature step.


5.5.3 Test data
—. Test Date                : November 14, 2017

—. Result                   : PASSED

   Temperature (°C)             Carrier Freq. (Hz)            Measured Freq. (Hz)           Margin (Hz)                  Limit (Hz)

            —20                                                    13 560 088                   1 268

            —10                                                    13 560 065                   1 291

             0                                                     13 560 072                   1 284

             10                                                    13 560 034                   1 322
                                          13 56                                                                          + 1 356.0
             20                                                    13 560 028                   1 328

             30                                                    13 560 013                   1 343

            40                                                     13 560 069                   1 287

             50                                                    13 560 088                   1 268




                                                                                              Tested by: Tae—Ho, Kim / Manager




Tt should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC—003 (Rev.2)
ONETECH Corp.: 43—14, Jinsaegol—gil, Chowol—cup, Gwangju—si, Gyeonggi—do, 12735, Korea (TEL: 82—31—799—9500, FAX: 82—31—799—9599)


onETECH
       N#                                                      Page 19 of 21                               Report No.: W17NR—D050


5.6 FREQUENCY STABILITY WITH VOLTAGE VARIATION


5.6.1 Operating environment
Temperature                           :        24.1 °C
Relative humidity                     :       49.0 % RH.


5.6.2 Test set—up
An external DC power supply was connected to the input of the EUT. The voltage of EUT set to 115 % of the nominal
value and then was reduced to 85 % of nominal voltage. The output frequency was recorded at each step.


5.6.3 Test data
—. Test Date                    : November 14, 2017

—. Result                       : PASSED

      Voltage (Vac)              Carrier Freq. (Hz)           Measured Freq. (Hz)           Margin (Hz)                  Limit (Hz)

       264.5(115 %)                                                 13 560 044                  1312

        230(100 %)                        13 560 000                13 560 013                  1343                      + 1 356.00

        195.5(85 %)                                                 13 560 038                  1318




                                                                                              Tested by: Tae—Ho, Kim / Manager




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC—003 (Rev.2)
ONETECH Corp.: 43—14, Jinsaegol—gil, Chowol—cup, Gwangju—si, Gyeonggi—do, 12735, Korea (TEL: 82—31—799—9500, FAX: 82—31—799—9599)


                                                               Page 20 of 21                               Report No.: W17NR-D050


6. FIELD STRENGTH CALCULATION

Meter readings are compared to the specification limit correcting for antenna and cable losses.




                                              +    Meter reading                     (dBμV)
                                              -   Amplifier Gain                     (dB)
                                              +    Cable Loss                        (dB)
                                              -   Antenna Factor                     (dB/m)
                                              =    Corrected Result                  (dBμV/m)


                                              Margin (dB)
                                                   Specification Limit               (dBuV/m)
                                              -    Corrected Result                  (dBuV/m)
                                              =    dB Relative to Spec               (± dB)




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 21 of 21                               Report No.: W17NR-D050


7. LIST OF TEST EQUIPMENT

  No.       EQUIPMENTS                    MFR.                 MODEL               SER. NO.        LAST CAL            DUE CAL       USE

   1.                                       R/S                  ESCI                101013       Apr. 04, 2017         One Year      □
   2.         Test receiver                 R/S                  ESPI                101278       Oct. 26, 2017         One Year      
   3.                                       R/S                   ESU                100261       Apr. 05, 2017         One Year      □
   4.      Spectrum analyzer                R/S                 FSU26                200319       Apr. 04, 2017         One Year      □
   5.      Spectrum analyzer                R/S                 FSV30                101199       Apr. 05, 2017         One Year      
                                         Sonoma
   6.           Amplifier                                        310N                312544       Apr. 04, 2017         One Year      
                                        Instrument
                                         Sonoma
   7.           Amplifier                                        310N                312545       Apr. 04, 2017         One Year      □
                                        Instrument
         TRILOG Broadband
   8.                                 Schwarzbeck            VULB9163              9163-255       May. 20, 2016        Two Year       □
                 Antenna
         TRILOG Broadband
   9.                                 Schwarzbeck            VULB9163              9163-419       Aug. 05, 2016        Two Year       
                 Antenna
                                                                                 CO3000/904/
  10.           Controller            Innco System             CO3000                                  N/A                 N/A        
                                                                                  37211215/L
                                                                                   9109-1867      Apr. 07, 2017         One Year      □
                                          EMCO                  3825/2
                                                                                   9109-1869      Apr. 06, 2017         One Year      □
  11.              LISN
                                      Schwarzbeck            NSLK8126              8126-404       Apr. 03, 2017         One Year      □
                                      Schwarzbeck            NSLK8128              8128-216       Apr. 05, 2017         One Year      □
  12.          Turn Table             Innco System             DT3000    930611                        N/A                 N/A        
                                                                       MA4000/509/
  13.       Antenna Master            Innco System         MA-4000XPET 37211215/L                      N/A                 N/A        
                                                                       MA4000/332/
  14.       Antenna Master            Innco System          MA4000-EP  27030611/L                      N/A                 N/A        □
  15.        Loop Antenna             Schwarzbeck            FMZB 1513             1513-235       Jun. 10, 2016        Two Year       
  16.     Frequency Counter                 HP                 53152A            US39270295       Sep. 05, 2017         One Year      
                                                                 EBE-
  17.           Chamber                   ESPEC            5E30W6PT2L-            3015006449      Mar. 22, 2017         One Year      
                                                                   22
  18.      DC Power Supply                Protek             PWS-3003D              4020409       Sep. 01, 2017         One Year      
  19.             Slidacs           Dea Kwang Elec.             DH-60                  N/A        Sep. 01, 2017         One Year       □




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)



Document Created: 2017-11-28 13:35:24
Document Modified: 2017-11-28 13:35:24

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC