SafezoneXID-500 Instruction Guide
                                    Ver 0.3


Safety Instructions

 The Following instructions ensure your safety and prevent any damage. Be sure to read the
  following instructions and use the product correctly


① Do not install the terminal in a place affected by direct sunlight, humidity, dust or soot.
② Keep the terminal away from magnets or anything containing magnetic material such as CRT, TV sets,
  computer monitors and speaker.
③ Keep the terminal away from heating products.
④ Do not put in water even though product have the IP-65 test certification.
⑤ Do not drop the terminal or subject it to heavy impact
⑥ Do not apply heavy pressure to the touch screen.
⑦ Do not disassemble, repair or reconstruct the terminal.
⑧ Do not use the terminal for any other purpose than original use.
⑨ In cases of product malfunction or problems, please contact a provider
⑩ Keep the product out of reach from people without authority


1. Port


1. Port
                                              ① LAN Port (for RJ-45)
                                              ② DIP S/W
                                                -R232 : Connect 2-3 and 5-6 with shunt
                                                -WIEGAND : Connect 1-2 and 4-5 with shunt
                                              ③ R485/RS232(WIEGAND) port
                                              ④ INPUT port
                                                1) INPUT1 : can be used when using EXIT Button
                                                2) INPUT2 : is indicating DOORSTATUS signal
                                                3) INPUT3 : Optional Input
                                              ⑤ OUTPUT port
                                                1) Electrical Lock connection
                                                   LOCK NO : NO connection
                                                   LOCK NC : NC connection
                                                   COM : COM connection
                         USB단자                  2) LOCK TR : for external Relay (optional)
                                              ⑥ Power Connection
                 ② DIP S/W         INPUT
                                               OUTPUT POWER
          LAN                                                  + -
          ①      ③485/232           ④              ⑤             ⑥
                RS-485    RS-485      GND          RS-232      RS-232
                  (+)       (-)                     RXD         TXD
                                                 (WIEGAND)   (WIEGAND)

                INPUT1    INPUT1     INPUT2       INPUT2       INPUT3       INPUT3
                 GND        (+)       GND           (+)         GND           (+)

                 LOCK      COM       LOCK           LOCK        LOCK
                  NO                  NC            TR(+)       TR(-)


1. 단말 포트

 Caution in connection of each port


 1) Power
   * SMPS or Adaptor : Installer should check the voltage level if it is 12V
   * Since including Adaptor have FGND so that Installer should check FGND with Adaptor


 2) RS232/WIEGAND Dip-switch install
   * RS232 : Set as 2-3 and 5-6
   * WIEGAND :    Set as 1-2 and 4-5


3) LOCK Control
   * In case of emergency status like blackout or power failure, Operator can use NC or NO


2. Network Setting


2. 네트워크

 Notice for connecting LAN jack


 - Should be check the connection of hook


 - Prevent the substance in the RJ-45


 - The following Icon indicates the network condition




             Link down, please check the cable connection

             Link up, physical connection is ok but need to check the setting such like IP.

             Link up and activation of data are OK.


3. EM / Deadbolt / Strike
(One-direction Installation)


3. EM / Deadbolt / Strike                                                                One-direction Installation

※ Electrical Lock should have the sensor of
                                                                                                              Hi-Box
the door status                               AWG24 * 2C


※ Connection Set
- UTP cable 1 PCS,                                    AWG24*1C
                                                                            Power GND-         AWG24*1C
                                                      ( LOCK NC)                               ( power+)
- Power Line 2P
- Control Line 6P
                                                             AWG24*1C
 (Including LOCK NC, LOCK COM,                             ( LOCK COM)

  Door status 2 cores, Exit 2 cores)
                                                          AWG24 * 2C                            AWG24 * 2C
                                                       ( 문상태,문상태GND)                          ( on/off signal )


                                UTP

                                                                           Power
                                                                                     Power+
                                                                            GND
                                                                         Door Lock




                     TPS Room


 3. EM / Deadbolt / Strike                                                                           One-direction Installation




       485   485          232   232   INPT1   INPT1   INPT2    INPT2   INPT3   INPT3         LOCK         LOCK   LOCK    LOCK      전원          전원
 LAN                GND                                                                             COM
       (+)    (-)         RXD   TXD    GND      (+)    GND       (+)    GND      (+)          NO           NC    TR(+)   TR(-)     (+)         (-)




                                                                                       GND                 (-)
                                                                                                                                 (+)     (-)



 TPS                                                                                         (+)
Room                                                          Door Lock
                                                                                                    (+)


 3. EM / Deadbolt / Strike                                            One-direction Installation




  [Operation Mode]             [Manager] > [Controller]                   [Manager] > [LCM]

                                                                   LCM유형 : None
                          Set to “단말기 해체 경보음”
                                                                   DoorLock 설정 : Set on purpose of
                          In/Out : Set on the specific purpose
                                                                    Lock type
 Set to “출입”
                                                                   Input#1(InsideOpen) : NO
                                                                   Input#2(Door Status) : Set on purpose
                                                                    of the status door type
                                                                   Input#3(Lock Status) : None


3. EM / Deadbolt / Strike                                                          One-direction check-point


 Abnormal LOCKing
 1. In case of the operation of LOCK is reversed :
    1) Confirm the setting of LCM as “RelayOut#1”
    2) Check the wire connection it is LOCK NC or NO.
       -ex) Fail safe type should be set as LOCK NC.
    3) Check the wire connection between XID-500 LOCK port with the electric LOCK


 2. In case of unlocking, even though tagging RF-CARD :
    1) Check the adjust setting of LCM.
    2) Be sure the power coming form Adaptor or Power source


 3. In case of the Deadbolt Lock (when door is closed, Deadbolt is not operated)
    1) Confirm the setting of LCM
    2) Check the position of the magnetic on the sensor
    3) Check the door-icon of XID-500
    4) Be sure the power coming form Adaptor or Power source


3. EM / Deadbolt / Strike                                                       One-direction check-point


 Abnormal Door status sensing


 1. In case of the operation of the Door status is reversed :
   : Check the wire connection and the setting of LCM is proper setting NC/NO


 2. The door status is no changed :
    1) Confirm the wire connection and the setting of LCM
    2) Check the door-lock have sensor can check door status.
    3) Even though above conditions have no problems, LOCK should be changed


 3. Status change in more frequent
    1) Check the wire connection
    2) Change the Door-lock


4. EM / Deadbolt / Strike
  (Bi-directional Installation)


4. EM / Deadbolt / Strike                                                               Bi-directional Installation

※ Electrical Lock should have the sensor of                                                                    Hi-Box
                                                                         AWG24 * 2C
the door status                               AWG24 * 2C                  ( Power+-)
                                               ( Power+-)
※ Connection Setting
Outdoor XID-500
- UTP cable 1 PCS, Power Line 2P                                         AWG24*1C                    AWG24*1C
                                                                          ( 전원+)          Power-     ( LOCK NC)
- Control Line 3P (RS-485 3 cores)
                                                        AWG24 * 3C
Indoor XID-500                                           (RS485)
                                                                                              AWG24*1C
- UTP cable 1 PCS, Power Line 2P                                                            ( LOCK COM)

- Control Line 7P   (LOCK NC, LOCK COM,
  Door status 2 cores, RS-485 3 cores)                                                    AWG24 * 2C
                                                                                         ( Door Status,
                               UTP                                                      Door Status GND)

                                                                          Power
                                                                Power+     GND

                                                                            Door Lock




                                              Outdoor XID-500                                              Indoor XID-500
                       TPS
                       Room


 4. EM / Deadbolt / Strike                                            Bi-directional Installation – Outdoor XID




       485   485          232   232   INPT1   INPT1   INPT2   INPT2   INPT3   INPT3   LOCK         LOCK   LOCK    LOCK        전원    전원
 LAN                GND                                                                      COM
       (+)    (-)         RXD   TXD    GND      (+)    GND      (+)    GND      (+)    NO           NC    TR(+)   TR(-)       (+)   (-)




                                                                                                                          Power Power
                                                                                                                           (+)   (-)


 TPS
        Indoor XID
Room
        RS-485 Port


 4. EM / Deadbolt / Strike                                                Bi-directional Installation – Indoor XID




       485   485          232   232   INPT1   INPT1   INPT2    INPT2   INPT3   INPT3         LOCK              LOCK    LOCK    LOCK            전원    전원
 LAN                GND                                                                               COM
       (+)    (-)         RXD   TXD    GND      (+)    GND       (+)    GND      (+)          NO                NC     TR(+)   TR(-)           (+)   (-)




                                                                                       전원                      Power
                                                                                                                                       Power     Power
                                                                                       GND                      (-)
                                                                                                                                        (+)       (-)


 TPS                                                                                     Power(+)
       Outdoor XID
Room                                                          Door Lock
       RS-485 Port                                                                                  Power(+)


 4. EM / Deadbolt / Strike                                                Bi-direction Installation




                [운용]                [기기관리] > [기기제어]                              [기기관리] > [LCM]


 Set to “출입”                 Set to “단말기 해체 경보음”                      LCM Type : None

                              In/Out : Set on the direction purpose    DoorLock 설정 : Set on purpose of

                              Set to “RS485 In/Out”                     Lock type

                              Make a role “Master/Slave”               Input#1(InsideOpen) : None
                                                                        Input#2(Door Status) : Set on purpose
                                                                         of the status door type
                                                                        Input#3(Lock Status) : None


4. EM / Deadbolt / Strike                                             Bi-direction notice


 Abnormal LOCK
  1. You can check the following when the door lock is not operated
  - Confirm the setting of RS485 IN/OUT
  - Be sure the direction of XID-500 Indoor/Outdoor
  ※ Other notice will be same except above two conditions


5. Dummy


5. DUMMY
※ Please RS232 port of XID-500 with other device in order to operate the dummy mode




                                                                                      Other Device




                                                         AWG24 * 2C
                                                          ( DC 12V )




                                                         AWG24 * 3C
                                                          (RS232)


11. DUMMY
 ※ RS232/WIEGAND Header
      - Check the shunt connection of 2-3 and 5-6



           485   485             232   232   INPT1   INPT1   INPT2   INPT2   INPT3   INPT3   LOCK         LOCK   LOCK    LOCK            전원    전원
LAN                      GND                                                                        COM
           (+)    (-)            RXD   TXD    GND      (+)    GND      (+)    GND      (+)    NO           NC    TR(+)   TR(-)           (+)   (-)




                                                                                                                                 Power     Power
                                                                                                                                  (+)       (-)
                   GND         232   232
                               TXD   RXD
 TPS
ROOM


11. DUMMY                                        Dummy Installation




              [운용]            [운용] > [Customize] > [Dummy설정]

     Set to “Dummy”    Dummy Type : RS232
                        Select the type of message(Message, Card number)
                        Confirm output mode


6. LCM Connection


 6. LCM Connection
※ RS485 port can connect with LCM                 Hi-Box

                                                                                            파랑
                                                                                                          XID3.0 LCM
                                                                                            초록

※ LCM Power should be seperated with XID-500                                                검정




                                                                              AWG24 * 2C
                                                   AWG24 * 2C                  ( DC 12V )
                                                    ( DC 12V )




                          Join RS485 wire


                                            UTP

                                    UTP


                                                             AWG24 * 3C                     AWG24 * 3C
                                                              ( RS-485)   Door Lock          ( RS-485)




                          TPS                     Outdoor XID-500                                Indoor XID-500
                          Room


 6. LCM Connections




       485     485           232   232   INPT1   INPT1   INPT2   INPT2   INPT3   INPT3   LOCK         LOCK   LOCK    LOCK            전원    전원
 LAN                   GND                                                                      COM
       (+)      (-)          RXD   TXD    GND      (+)    GND      (+)    GND      (+)    NO           NC    TR(+)   TR(-)           (+)   (-)




                                                                                                                             Power     Power
                                                                                                                              (+)       (-)


 TPS
Room         GND      TRXD- TRXD+

                 LCM RS485 port


6. LCM Connections                                                                       Installation




      [운용]                      [기기관리] > [기기제어]                              [기기관리] > [LCM]


   Set “운용모드” to “출입”    Set to “단말기 해체 경보음”                      LCM Type : XID3.0
                          In/Out : Set on the direction purpose    DoorLock 설정 : None
                                                                    Input#1(InsideOpen) : None
                                                                    Input#2(Door Status) : NO or NC
                                                                    Input#3(Lock Status) : None


7. Additional Relay


Additional Relay

 The method of additional Relay connection


                                              The Relay capability should meet the


    ③①                            ⑤④          minimum requirements of 12V/5A
                                              Left image is showing 2 poles and 8 pins


                                              To operate NC1 or NO1, connect Pole1.
                                              To operate NC2 or NO2, connect Pole2.
                                              ① 12V power for the Relay coil
                                              ② 12V Coil Gnd
                                              ③ Pole1

   ⑥②                             ⑧ ⑦         ④ NO1
                                              ⑤ NC1
                                              ⑥ Pole2
                                              ⑦ NO2
                                              ⑧ NC2


XID-500 Product Specifications


                       Item                            XID5.0

   Card Option                              13.56 MHz
                                            ISO14443 A/B(MIFARE)
   Physical      Size (mm)                  84 X 164 X 22.8

                 Weight (g)                 260

   Interface     Communication Interface    RJ45, TCP/IP, 10/100T
                                            RS-485
                                            RS-232
                                            USB (for Printer)

                                            USB (for F/W Upgrade)
                 Wiegand                    Output

                 TTL                        -

                 Built-in Relay             1

   Expandable    Additional Relay Control   1 (12V External Relay)
   Function
                 Wireless LAN               -

                 SAM                        1


XID-500 Product Specifications

                       Item                          XID5.0
    Hardware        CPU                     536 MHz
                                            (SAMA5D31, Cortex A5)

                    Memory                  8 MB S-flash + 4 GB
                                            eMMC + 256 MB RAM

                    LCD Display             4.3” color touch screed

                    Humidity                90 %

                    Tamper                  Switch

                    Operating Voltage       12 VDC

                    Audio Output Power      1.0 W

                    WDT                     HW(MICOM), SW

                    RTC Battery             Yes

    Environment     Operating Temperature   -20 ~ 50 °C
    Specification
                    Humidity                90 %

                    ESD                     Contact : < 8 kV
                                            Air : < 15 kV

                    Certification           KC, SRRC, CE

                    Water Proof             IP65


XID-500 Product Specifications


                    Item                     XID5.0

    Power     Voltage (V)                      12

              Current (mA)                  400 (Max.)

    Switch    VIH (V)                          12
    Input
              VIL (V)                       GND (Low)

              Pull-up resistance (Ω)           10 K

    Wiegand   VOH (V)                           5
    Output
              VOL (V)                       GND (Low)

              Pull-up resistance (Ω)          4.7 K

    Relay     Relay Type                       Dry

              Switching capacity (A)         2 (Max.)

              Switching power (resistive)   60W (Max.)

              Switching voltage (VDC)          220


FCC Information


This device complies with part 15 of the FCC Results. Operation is subject to the
following two conditions :
         (1) This Device may not cause harmful interface, and
         (2) This device must accept any interference received, including interference that
             may cause undesired operation.


Note: This equipment has been tested and found to comply with the limits for CLASS B digital
device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
correct the interference by one or more of the following measures:


1.1. Reorient or relocate the receiving antenna.
1.2. Increase the separation between the equipment and receiver.
1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is
connected.
1.4. Consult the dealer or experienced radio/TV technician for help.




WARNING
Changes or modifications not expressly approved by the manufacturer could void the
user’s authority to operate the equipment.


IMPORTANT NOTE:
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with a
minimum distance of 20 centimeters between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other antenna
or transmitter.