Maximum Permissible Exposure
FCC, Part 15 Subpart C §15.407(f)
Industry Canada RSS-Gen §5.5

Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4πd2)
EIRP = P * G * 2
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)
Power level reported in the following matrix is the maximum combined power level
reported in Section 5.1.3. Maximum antenna gain was used to calculate the Maximum
Permissible Exposure distance.

Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of
power density is 1.0 mW/cm2

                                                                Peak        Calculated
                                                  Peak                                    Minimum
                                 Numeric                       Output          Safe
 Freq. Band     Antenna                          Output                                  Separation
                                  Gain                         Power        Distance @
   (MHz)        Gain (dBi)                       Power                                    Distance
                                (numeric)                        x2          1mW/cm2
                                                 (dBm)                                      (cm)
                                                               (mW)          Limit(cm)
 5150 - 5250       7.02             5.04          +13.95        24.83            3.2       20.00

Note: for mobile or fixed location transmitters the minimum separation distance is 20cm,
even if calculations indicate the MPE distance to be less.


Specification
Maximum Permissible Exposure Limits


 FCC §1.1310 Limit = 1mW / cm2 from 1.310 Table 1

 RSS-Gen §5.5 Before equipment certification is granted, the application requirements of
 RSS-102 shall be met.




                    MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566