PC Peripheral Test Report Revision 2

FCC ID: RS2X2G100

Test Report

Download: PDF
FCCID_715717

                  EMI Research and Development Laboratory
                    Department of Electrical Engineering
                         Florida Atlantic University        FAU EMI R&D LAB
                         3998 FAU Blvd, Suite 310
                         Boca Raton, Florida 33431
                               (561) 361-4390


                         Technical Report No. 06-074


           “EMI Evaluation of the XM Satellite Radio, Inc.
          XM2go XM Satellite Radio Receiver to FCC Class B
         Conducted and Radiated Emission Requirements for a
            PC Peripheral Device – Model No. X2G-100”


Date Performed: 9/28/2006-9/29/2006

Customer: XM Satellite Radio, Inc.
         Attn: Terry Helstrom
         3161 S.W. 10th street
         Deerfield Beach, FL 33442

Company Official responsible
for product(s) tested:      _______________________________
                            Terry Helstrom, Engineer



Test Performed and
Reported By:                _______________________________
                            Raymond Aina, Test Engineer
                            FAU EMI R&D Laboratory



Approved by:                ________________________________
                            Vichate Ungvichian, Ph.D., P.E.
                            Director, FAU EMI R&D Laboratory


Date of Test Report: 2 October 2006



                                                                 2129.01


                        Table of Contents



1.   Introduction                                    3
2.   Objective                                       3
3.   Conclusion                                      3
4.   Test Procedure and Results
         4.1 Table of Data Plots                     4
         4.2 General Test Procedures                 4
         4.3 Conducted Emissions 15.107(a)           5
         4.4 Radiated Emissions 15.109(a)            7
         4.5 Test Equipment                          16




                       Technical Report No. 06-074

                                                          2


1. INTRODUCTION

The XM Satellite Radio, Inc., XM2go Model X2G-100 was evaluated for
compliance to the FCC Class B requirements and the results apply only to the
specific items of equipment, configurations and procedures supplied to the Florida
Atlantic University EMI Research Lab by XM Satellite Radio, Inc., as reported in
this document.

2. OBJECTIVE

Test Specifications

This evaluation was performed to verify conformance of the XM Satellite Radio,
Inc., XM2go XM Satellite Radio receiver to U.S. Federal Communications
Commission (FCC) Code of Federal Regulations (CFR), Title 47 -
Telecommunication, Part 15 - Radio Frequency Devices,

   •   Section 15.107(a) Conducted limits, and
   •   Section 15.109(a) Radiated Class B Emission limits.

Modes of Operation Tested

Per ANSI C63.4 Section 11, Measurement of Information Technology Equipment
(ITE), the device under test was configured to be continuously receiving data from a
host PC via a USB connection.

The Minimum System Requirements of ANSI C63.4, Section 11.2, were met by
using a host PC (laptop computer), and an additional external peripheral device
which utilized the Serial Port of the laptop with continuous data traffic on the cable.

Host PC : Laptop Model Compaq nc6000, Serial # CNU41228G9
External Peripheral : Earthmate GPS Receiver, Model Delorme
EUT : XM2go Hardware ID : BCWRJQMB

   •   During FCC Part 15 Subpart B, Paragraph 15.107(a) conducted emissions
       tests, the EUT was configured with the EUT in the XM2go home cradle with
       the XM Home AC adaptor.
   •   During FCC Part 15 Subpart B, Paragraph 15.109(a), radiated emissions, the
       EUT was configured and tested in two different operating modes:
           o In a XM2go home cradle powered by a 5V AC wall adapter.
           o In Portable Mode, under battery power.

3. CONCLUSION

The XM Satellite Radio, Inc., XM2go Model X2G-100, met the FCC Class B
conducted and radiated emission requirements as a PC Peripheral Device as
described in the following report.

                             Technical Report No. 06-074

                                                                                    3


4. TEST PROCEDURES AND RESULTS


  4.1 TABLE OF DATA PLOTS
   Figure
      #            Test            Mode of Operation     Frequency Range     Polarization
      1          Conducted           Home Cradle          150KHz - 30MHz         N/A
      2           Radiated           Home Cradle         30MHz - 200MHz        Vertical
      3           Radiated           Home Cradle         30MHz - 200MHz       Horizontal
      4           Radiated           Home Cradle          200MHz - 1GHz        Vertical
      5           Radiated           Home Cradle          200MHz - 1GHz       Horizontal
      6           Radiated             Portable          30MHz - 200MHz        Vertical
      7           Radiated             Portable          30MHz - 200MHz       Horizontal
      8           Radiated             Portable           200MHz - 1GHz        Vertical
      9           Radiated             Portable           200MHz - 1GHz       Horizontal



  4.2 GENERAL TEST PROCEDURES

  The measurement techniques identified in the measurement procedure of ANSI
  C63.4-2003 "American National Standard of Measurement of Radio-Noise
  Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9
  kHz to 40 GHz" were followed as close as practical during this evaluation. Complete
  details and specific procedures used are discussed in the respective test result
  sections.




                              Technical Report No. 06-074

                                                                                  4


4.3 CONDUCTED EMISSIONS – Section 15.107(a)

4.3.1 Test Setup – Conducted Emissions

The XM Satellite Radio, Inc., XM2go50 Model X2G-100B; was powered by a I.T.I
 Power Supply Model No. SMPS5V2A-XMRT. The 120VAC/ DC 5V switching
power supply was then installed in the FAU EMI Research facilities conducted
emissions shielded enclosure on a wooden test table 80 centimeters above the ground
plane floor and 40 centimeters from the rear wall. The I.T.E Power Supply was then
plugged into an EMCO Model No.3825/2R Serial No. 1095, 50 Ω, 50 µH Line
Impedance Stabilization Network (LISN).

Conducted power line emissions were measured on both the phase and neutral lines
with reference to earth ground, over the specified 150 kHz to 30 MHz range on a
Hewlett Packard HP 8566B Spectrum Analyzer operated in the peak detection mode
with a bandwidth of 9 kHz obtained through the HP 85650A Quasi Peak Adapter and
in conjunction with HP85685A preselector. Photograph 1 and 2 depict the
conducted setup.




                            Technical Report No. 06-074

                                                                                5


          4.3.2 Test Data – Conducted Emissions

          The EUT was tested for the peak-detected emissions on phase and neutral lines while
          the XM2go50 unit was receiving data over the USB link connected to the host PC.




              Figure 1: Phase and Neutral Conducted Emissions 150 kHz-30 MHz

 Line        Frequency       Peak     Average     QP Value      Limit                 Margin
Tested         (kHz)        Value       Value      (dBµV)      (dBµV)                  (dB)
                           (dBµV)      (dBµV)
Phase          150.12        57.8        25.5          -         55.5                    30
Neutral        150.12        56.0        25.2          -         55.5                   30.3
                  Table 1 : Peak Measurement Results – Conducted Emissions

                                      Technical Report No. 06-074

                                                                                          6


4.4 RADIATED EMISSIONS – Section 15.109(a)

4.4.1 General Test Setup – Radiated Emissions

The XM Satellite Radio, Inc., XM2go Model X2G-100 was set up on a wooden table
80 centimeters above the ground plane turntable of the FCC listed Semi-Anechoic
test site.

An EMCO 3104 Broadband Biconical antenna was installed on an EMCO
pneumatically controlled Antenna Mast at a distance of 3 meters from the system.
The 30 to 200 MHz frequency range was automatically scanned on the HP 8566B
Spectrum Analyzer operated in the peak detector mode with a bandwidth of 120 kHz
obtained through the HP 85650A Quasi Peak Adapter. It should be noted that the
RES BW and VBW of the spectrum analyzer must be set to 1 MHz for the Quasi
Peak Adaptor to provide 120 kHz bandwidth correctly. Hence, in the figures RES
BW and VBW are still indicated as 1 MHz. The turntable was incrementally rotated
through 360 degrees and at the same time the receiving antenna was scanned in
height from 1 to 4 meters in both the horizontal and vertical polarizations. An
EMCO 3146 Log Periodic antenna was then installed and the above procedure was
repeated for the 200 to 1000 MHz ranges.

The FCC Class B limit lines have been corrected for the appropriate antenna factors,
cable loss, and amplifier gain based on the following equation:

E (dBµV/m) = SA reading (dBµV) + Antenna Factor (dB/m) + Cable Loss (dB) -
             Amp Gain (dB)

The EUT was tested in TWO configurations under Section 15.109(a)
   o Home Cradle with Speaker attached
   o Portable Mode under battery power




                            Technical Report No. 06-074

                                                                                 7


4.4.2 Radiated Emissions – Home Cradle (with USB transfer)

  4.4.2.1 Test Setup – Home Cradle
                                                                                  Speaker - R
            Speaker - L                                       Laptop PC
                          To
                          Speakers       XM
                                         Radi        USB
        XM Home                                                           RS232    GPS receiver
                                                     cable                Cable                   Wooden
                                      Home cradle                                                  table



                                                      10                  10
                          10




                     23 ft
                     antenna cable


                           30 to 40




              40 cm

                                                    AC Wall supply                    Ground


         Diagram 1 : Radiated Emissions – Home Cradle – Test Setup




                               Technical Report No. 06-074

                                                                                         8


4.4.2.2 Test Data – Home Cradle




 Figure 2 : Radiated Emissions – Home Cradle – 30MHz to 200MHz - Vertical




Figure 3 : Radiated Emissions – Home Cradle – 30MHz to 200MHz - Horizontal

                       Technical Report No. 06-074

                                                                    9


 Figure 4 : Radiated Emissions – Home Cradle – 200MHz to 1GHz - Vertical




Figure 5 : Radiated Emissions – Home Cradle – 200MHz to 1GHz - Horizontal

                       Technical Report No. 06-074

                                                                    10


                         Measured    Quasi   Correction   Corrected     FCC
             Frequency     Peak       Peak    Factor        Peak        Limit    Margin
Figure No.     (MHz)     (dBµV)     (dBµV)     (dB)       (dBµV/m)    (dBµV/m)    (dB)
    2           145.9      55.1       42.7     -14.0         28.7        43.5     14.9
    3           147.0      56.6       43.3     -14.0         29.3        43.5     14.2
    4           248.8      60.6       45.6     -13.7         31.9        46.0     14.2
    4           500.0      52.3       44.8      -7.0         37.8        46.0      8.2
    5           248.8      60.4       49.5     -13.7         35.8        46.0     10.2
    5           399.2      59.5       41.2      -9.6         31.6        46.0     14.4


   Table 2 : Peak Measurement Results – Home Cradle Radiated Emissions




                               Technical Report No. 06-074

                                                                                  11


4.4.3 Radiated Emissions - Portable Mode (USB Transfer)
Note : For each portable mode test setup, the radio was placed in
each of three possible axis. The reported data is from axis which
results in overall highest emissions.

   4.4.3.1   Test Setup – Portable Mode
                                   Laptop PC


                  XM
                 Radio    USB                  RS232   GPS receiver
                          cable                Cable                                 Wooden
                                                                                      table



                           10 cm               10 cm




                                                                      Ground Plane




      Diagram 2 : Radiated Emissions – Portable Mode – Test Setup




                         Technical Report No. 06-074

                                                                        12


     4.4.3.2 Test Data – Portable Mode




Figure 6 : Radiated Emissions – Portable Mode – 30MHz to 200MHz - Vertical




Figure7 : Radiated Emissions – Portable Mode – 30MHz to 200MHz - Horizontal

                        Technical Report No. 06-074

                                                                    13


 Figure 8 : Radiated Emissions – Portable Mode – 200MHz to 1GHz - Vertical




Figure 9 : Radiated Emissions – Portable Mode – 200MHz to 1GHz - Horizontal


                        Technical Report No. 06-074

                                                                     14


                     Measured    Quasi   Correction   Corrected     FCC
Figure   Frequency     Peak       Peak    Factor        Peak        Limit    Margin
 No.       (MHz)     (dBµV)     (dBµV)     (dB)       (dBµV/m)    (dBµV/m)    (dB)
  7         145.9      60.5       45.6     -14.0         31.6        43.5     11.9
  8         248.8      63.2       44.3     -13.7         30.6        46.0     15.4
  9         248.8      59.9       49.5     -13.7         35.8        46.0     10.2
  9         324.1      57.5       47.6     -10.5         37.1        46.0      8.9
  9         362.0      58.0       48.0      -9.9         38.1        46.0      7.9
  9         400.0      59.3       48.9      -9.6         39.3        46.0      6.7


Table 3 : Peak Measurement Results – Portable Mode Radiated Emissions




                            Technical Report No. 06-074

                                                                               15


      4.5 TEST EQUIPMENT

      FAU EMI LAB –
      Equipment used for Radiated and Conducted Emissions


              FAU EMI R&D LABORATORY TEST EQUIPMENT
Equipment Manufacturer Description Model   Serial No. Calibration Calibration
   Type                                                  Date      Interval
                                                                   (Years)
 Spectrum   Hewlett    RF Section   8566B 2403A06381 Aug-22-06         2
 Analyzer   Packard
 Spectrum   Hewlett     Display    85662A 2407A06381 Aug-22-06         2
 Analyzer   Packard
 Spectrum   Hewlett    Quasi Peak 85650A 2430A00559 Aug-22-06          2
 Analyzer   Packard     Adapter

    RF        Hewlett   Preselector   85685A 2510A00151   Feb-8-06         2
Preselector   Packard

  LISN        EMCO          Line      3825/2R     1095    Mar-10-06        2
                         Impedance
                        Stabilization
                          Network




                            Technical Report No. 06-074

                                                                      16


TEST FACILITY

FAU EMI Research and Development Laboratory
Department of Electrical Engineering
Florida Atlantic University
Boca Raton, Florida 33431
(561) 361-4390

A2LA Certificate Number: 2129.01
FCC Registration: 90599
Industry of Canada: IC46405-4076

  Description:     The 3-m semi-anechoic chamber and Power Line Conducted Spurious
                   Voltage test setup is constructed and calibrated to meet the FCC
                   requirements of Section 2.948, as well as Industry Canada RSS 212 Issue
                   1.
  Site Filing:     A site description is on file with the Federal Communications
                   Commission, 7435 Oakland Mills Road, Columbia, MD 21046, and with
                   the Industry Canada, Certification and Engineering Bureau, 3701 Carling
                   Ave., Building 94, P.O. Box 11490, Station “H”, Ottawa Ontario, K2H
                   8S2.
  Instrument       All measuring equipment is in accordance with ANSI C63.4 and CISPR
  Tolerance:       22 requirements.




                        End Report




                         Technical Report No. 06-074

                                                                            17



Document Created: 2006-10-12 13:27:50
Document Modified: 2006-10-12 13:27:50

© 2025 FCC.report