revised test report page 25

FCC ID: RS2GEXINNO1

Test Report

Download: PDF
FCCID_639807

The test methodology followed during the collection of the data included within this
technical report was ANSI C63.4:1992.
                                2003.
The EUT was powered with (120) VAC / (60) Hz during the collection of data included
within.

The data is compared to the FCC Part 15 Class B limits.

The "EMI" instrumentation is capable of calculating the final emission level based on the
following formula:

Level at the receiver (dB V) + Antenna Correction Factor (dB/M) + Cable Loss (dB) -
Preamp Gain (dB) = Actual Level in dB V/M.

The sample calculation below is based on the actual test data collected:


           Observed Level         63.1   dB V
           ACF                     8.7   dB/M
           Cable Loss              1.4   dB
           Preamp Gain            26.0   dB
           Actual Level           47.2   dB V/M        @ MHz




      Please have a company official review this report and sign.