FCC ID. :RRKGLM100                                                    Report No.: EME-061171
                                                                              Page 1 of 5




    Maximum Permissible Exposure (MPE)
            Evaluation Report

                          Report No.       : EME-061171
                          Model No.        : GLM-100
                          Issued Date      : Nov. 9, 2006




     Applicant     : Alpha Networks Inc.
                    No.8 Li-shing 7th Rd., Science-based Industrial Park,
                    Hsinchu, Taiwan

     Test By       : Intertek Testing Services Taiwan Ltd.
                     No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li,
                     Shiang-Shan District, Hsinchu City, Taiwan



     This test report consists of 5 pages in total. It may be duplicated completely
     for legal use with the allowance of the applicant. It shall not be reproduced
     except in full, without the written approval of Intertek Laboratory. The test
     result(s) in this report only applies to the tested sample(s).




     Project Engineer                                        Reviewed By




      Rico Deng                                                Kevin Chen


FCC ID. :RRKGLM100                                                                                  Report No.: EME-061171
                                                                                                            Page 2 of 5
                                                  Table of Contents

Summary of Tests ............................................................................................................. 3

1. Introduction .................................................................................................................. 4

2. RF Exposure Limit ....................................................................................................... 4

3. RF Exposure calculations ............................................................................................. 5

4. Test results .................................................................................................................... 5


FCC ID. :RRKGLM100                                          Report No.: EME-061171
                                                                    Page 3 of 5


Summary of Tests

MPE Evaluation meet FCC OET No. 65: 1997/ IEEE C95.1-1999

              Wireless Mini PCI Adapter-Model: GLM-100
                        FCC ID: RRKGLM100

      Test                            Reference                       Results
 MPE Evaluation      FCC Guidelines for Human Exposure IEEE C95.1       Pass


FCC ID. :RRKGLM100                                                  Report No.: EME-061171
                                                                            Page 4 of 5

1. Introduction

The EUT operates in the 2.4GHz ISM band. Due to the EUT (include antenna) at its
normal operation distance is at least 20 cm from the human body, the EUT was defined
as a Mobile Device.


The reason to do the MPE Evaluation is to avoid the RF hazard to human body. The
maximum output power and gain of the antenna were used to calculate the limited
Power density (S) at 20cm distance away from the product. The limit for Maximum
Permissible Exposure (MPE) specified in FCC 1.1310 is followed.


According to 1.1307 (b)(1), systems operating under the provisions of this section shall
be operated in a manner that ensure that the public is not exposed to radio frequency
energy level in excess of the Commission’s guideline.



2. RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b).

                   Limits for Maximum Permissible Exposure (MPE)

   Frequency       Electric Field Magnetic Field
                                                     Power Density        Average Time
     Range           Strength         Strength
                                                       (mW/cm2)            (minutes)
     (MHz)            (V/m)            (A/m)
                   (A) Limits for Occupational / Control Exposures
     30-300             61.4             0.163               1.0                 6
   300-1500               -                 -              F/300                 6
 1500-100,000             -                 -                5                   6
               (B) Limits for General Population / Uncontrolled Exposure
     30-300             27.5             0.073               0.2                30
   300-1500               -                 -              F/1500               30
 1500-100,000             -                 -                1.0                30

F= Frequency in MHz


FCC ID. :RRKGLM100                                              Report No.: EME-061171
                                                                        Page 5 of 5

3. RF Exposure calculations

From §FCC 1.1310 table 1, the maximum permissible RF exposure for an
uncontrolled environment is 1mW/(cm2)
Power density (S) is calculated by the following formula:

S = (P * G)/4πR2

where, S = Power density (mW/cm2)
       P = Output power to antenna (mW)
       R = Distance between radiating structure and observation point (cm)
       G = Gain of antenna in numeric
       π = 3.1416

Example:
         Assume a mobile device operates at 2412MHz and its maximum output power
is 50mW, and the maximum gain of antenna is 1 (numeric) /0dBi.

then the power density (S) = (50 * 1)/4*π*202 = 0.00995 (mW/cm2)

4. Test results

     Test Mode: 802.11b (DSSS Modulation) operating mode
                 Channel    Maximum Output power Power density Limit of
   Channel      Frequency antenna gain to antenna                 power density
                                                                2
                  (MHz)      (numeric)      (mW)        (mW/cm )   (mW/cm2)
  1 (lowest)       2412         1.58        40.93        0.12904      1.0
  6 (middle)       2437         1.58        35.65        0.01124      1.0
 11 (highest)      2462         1.58        31.84        0.01004      1.0



     Test Mode: 802.11g (OFDM Modulation) operating mode
                 Channel    Maximum Output power Power density Limit of
   Channel      Frequency antenna gain to antenna               power density
                  (MHz)     (numeric)      (mW)        (mW/cm2)  (mW/cm2)
  1 (lowest)       2412        1.58        80.54        0.02539     1.0
  6 (middle)       2437        1.58        61.80        0.01949     1.0
 11 (highest)      2462        1.58        62.09        0.01958     1.0

The Notice in Installation Manual has been stated as below:
While installing and operating this transmitter, the radio frequency exposure limit of
1mW/(cm*cm) may be exceeded at distances close to the transmitter. therefore, the user
must maintain a minimum distance of 20 cm from the device at all time.