MPE

FCC ID: RRKGLM100

RF Exposure Info

Download: PDF
FCCID_1088043

                                                                FCC ID. : RRKGLM100
                                                             Report No.: EME-061171/02
                                                                         Page 1 of 6




 Maximum Permissible Exposure (MPE)
         Evaluation Report

                     Report No.      EME-061171/02
                     Model No.       GLM-100
                     Issued Date     Mar. 26, 2009

Applicant:     Alpha Networks Inc.
               No.8 Li-shing 7th Rd., Science-based Industrial Park,
               Hsinchu, Taiwan

Test Method/ FCC 1.1310 and Safety Cord 6
Standard:

Test By:       Intertek Testing Services Taiwan Ltd.
               No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li,
               Shiang-Shan District, Hsinchu City, Taiwan

It may be duplicated completely for legal use with the allowance of the applicant. It
shall not be reproduced except in full, without the written approval of Intertek
Laboratory. The test result(s) in this report only applies to the tested sample(s).



The test report was prepared by:          Sign on File
                                          Sammi Liu/Assistant

These measurements were taken by:         Sign on File
                                          Leon Cheng/Engineer

The test report was reviewed by:

                                           Name Kevin Chen
                                           Title Chief Engineer


                                                                                                           FCC ID. : RRKGLM100
                                                                                                        Report No.: EME-061171/02
                                                                                                                    Page 2 of 6


                                                      Table of Contents

Summary of Tests ............................................................................................................. 3

1. Introduction .................................................................................................................. 4

2. RF Exposure Limit ....................................................................................................... 4

3. RF Exposure calculations ............................................................................................. 5

4. Test results .................................................................................................................... 6


                                                               FCC ID. : RRKGLM100
                                                            Report No.: EME-061171/02
                                                                        Page 3 of 6


Summary of Tests

MPE Evaluation meet FCC OET No. 65: 1997, IEEE C95.1-1999 and IC
Safety Code 6

                  Wireless Mini PCI Adapter -Model: GLM-100
                            FCC ID: RRKGLM100

      Test                          Reference                      Results
                   FCC Guidelines for Human Exposure IEEE C95.1
 MPE Evaluation                                                   Complies
                   and IC Safety Code 6


                                                                         FCC ID. : RRKGLM100
                                                                      Report No.: EME-061171/02
                                                                                  Page 4 of 6

1. Introduction

The EUT operates in the 2.4GHz ISM band. Due to the EUT (include antenna) at its
normal operation distance is at least 20 cm from the human body, the EUT was defined as a
Mobile Device.


The reason to do the MPE Evaluation is to avoid the RF hazard to human body. The
maximum output power and gain of the antenna were used to calculate the limited Power
density (S) at 20cm distance away from the product. The limit for Maximum Permissible
Exposure (MPE) specified in FCC 1.1310 and Safety Cord 6 are followed.


According to 1.1307 (b)(1), systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio    frequency energy
level in excess of the Commission’s guideline.



2. RF Exposure Limit

For FCC:
According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
the environmental impact of human exposure to radio-frequency (RF) radiation as specified
in 1.1307(b).

                     Limits for Maximum Permissible Exposure (MPE)

   Frequency        Electric Field Magnetic Field
                                                      Power Density        Average Time
     Range            Strength         Strength
                                                        (mW/cm2)            (minutes)
     (MHz)             (V/m)            (A/m)
                    (A) Limits for Occupational / Control Exposures
     30-300             61.4              0.163              1.0                6
   300-1500               -                 -               F/300               6
 1500-100,000             -                 -                 5                 6
               (B) Limits for General Population / Uncontrolled Exposure
     30-300             27.5              0.073              0.2               30
   300-1500               -                 -              F/1500              30
 1500-100,000             -                 -                1.0               30

F= Frequency in MHz


                                                                            FCC ID. : RRKGLM100
                                                                         Report No.: EME-061171/02
                                                                                     Page 5 of 6

For IC:
Exposure Limits for Persons Not Classed As RF and Microwave Exposed Workers
(Including the General Public)

   Frequency       Electric Field   Magnetic Field
                                                        Power Density       Average Time
     Range         Strength; rms    Strength; rms
                                                           (W/m2)            (minutes)
     (MHz)             (V/m)            (A/m)
    0.003-1             280              2.19                  -                   6
      1-10             280/f             2.19/f                -                   6
     10-30              28               2.19/f                -                   6
    30-300              28               0.073                2*                  30
                              0.5                 0.5
   300-1500          1.585f           0.0042f               F/150                 30
  1500-15000           61.4              0.163                10                  30
 15000-150000          61.4              0.163                10             616000/f 1.2
150000-300000       0.158 f 0.5     4.21 × 10-4 f 0.5    6.67 × 10-5 f       616000/f 1.2

* Power density limit is applicable at frequencies greater than 100 MHz.
Notes: 1. Frequency, f, is in MHz.
       2. A power density of 10W/m2 is equivalent to 1 mW/cm2.
       3. A magnetic field strength of 1 A/m corresponds to 1.257 microtesla (μT) or 12.57
          milligauss (mG).


3. RF Exposure calculations

From §FCC 1.1310 table 1 and §Safety Code 6 table 5, the maximum permissible RF
exposure for an uncontrolled environment is 1mW/(cm2) (or 10 W/m2)*
      * 10 W/m2 = 1mW/ (cm2)
Power density (S) is calculated by the following formula:

S = (P * G)/4πR2

where, S = Power density (mW/cm2)
       P = Output power to antenna (mW)
       R = Distance between radiating structure and observation point (cm)
       G = Gain of antenna in numeric
       π = 3.1416

Example:
        Assume a mobile device operates at 2412MHz and its maximum output power is
50mW, and the maximum gain of antenna is 1 (numeric) /0dBi.

then the power density (S) = (50 * 1)/4*π*202 = 0.00995 (mW/cm2) (or = 0.0995 W/m2)


                                                                        FCC ID. : RRKGLM100
                                                                     Report No.: EME-061171/02
                                                                                 Page 6 of 6

4. Test results

     Test Mode: 802.11b mode
                Channel      Maximum Output power           Power density Limit of
   Channel     Frequency antenna gain to antenna                        power density
                 (MHz)       (numeric)  (mW)                 (mW/cm2)    (mW/cm2)
  1 (lowest)      2412           2     40.8319              0.012874493     1.0
  6 (middle)      2437          2      34.8337              0.010983232     1.0
 11 (highest)     2462           2     31.6957              0.009993788     1.0

     Test Mode: 802.11g mode
                 Channel     Maximum Output power           Power density Limit of
   Channel      Frequency antenna gain to antenna                       power density
                  (MHz)      (numeric)   (mW)                (mW/cm2)    (mW/cm2)
  1 (lowest)       2412         2       80.5378             0.025393943     1.0
  6 (middle)       2437         2       60.9537             0.019218972     1.0
 11 (highest)      2462         2       61.6595             0.019441517     1.0


The Notice in Installation Manual has been stated as below:
While installing and operating this transmitter, the radio frequency exposure limit of 1mW/
(cm2) may be exceeded at distances close to the transmitter. therefore, the user must maintain
a minimum distance of 20 cm from the device at all time.



Document Created: 2009-03-27 09:31:00