RF Exposure Info-SAR report part 2

FCC ID: RQQHLT-L553TA

RF Exposure Info

Download: PDF
FCCID_4484666

Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 101 of 163

Appendix D. DASY System Calibration Certificate


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 102 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 103 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 104 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 105 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 106 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 107 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 108 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 109 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 110 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 111 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 112 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 113 of 163


Anbotek Begc.Iof
oo rasseip         Anbotek Testing



                              fi in Conba-n'onewem

                                                       CAuBRraNoN LABORATORY
                            Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
                            Tel: +86—10—62304633—2512     Fax: +86—10—62304633—2504
                            E—mail: cttl@chinattl.com      Hitp://www.chinattl.en


                   DC Voltage Measurement
                         A/D — Converter Resolution nominal
                             High Range:       1LSB =       6.1uV , full range =    —100... +300 mV
                             Low Range:        1LSB =       61nV ,  full range =    —1....... +3mV
                         DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec


                          Calibration Factors                   X                               Y               2

                          High Range                  406.354 + 0.15% (k=2) 406.056 + 0.15% (k=2) 406.182 + 0.15% (k=2)

                          Low Range                   3.98644 +0.7% (k=2)          3.99365 +0.7% (k=2)   3.99469+0.7% (k=2)


                  Connector Angle

                         Connector Angle to be used in DASY system                                           1044 *




                  Certificate No: Z19—60066                                  Page 3 of 3




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:D, Sogood Science and Technology Park, SanweiCommunity,                                                @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                                                °/ 400—003—0500
Tel:(86)755—26066440—~      Fax:(86)755—26014772                  Email:service@anbotek.com                                   www.anbotek.com


Anbotek B¥ ETF¢]]
Lcb e G3)          Anbotek Testing




                                                   id‘m
                                                   *      In Collaboration with
                                                                                                                                  tAEAAT
                                     TTL s_p_e_a_g 8‘                                                                             Aray.
                                                          eauunenion cAcommons                  S
                             Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, Ching ”.,f\\\f
                                                                                                               RACNAS#:
                                                                                                                      CALIBRATION
                             Tel: +86—10—62304633—2070      P+86—10—62304633—2504               "Aliclat®                        CNAS LO570
                             E—mail: cttl@chinatl.com           tpswowschinati.en
                       Client           Anbotek (Aucen)                                      Certificate No:      218—97089

                 CALIBRATION CERTIFICATE

                 Object                                    DB35V2 — SN: 40154

                 Calibration Procedure(s)                  ipmmasresa
                                                           Calibration Procedures fordipole validation kits

                 Calibration date                          Jun 16, 2018

                 This calibration Certificate documents the traceability to national standards, which realize the physical units of
                 measurements(S1). The measurements and the uncertainties with confidence probability are given on the following
                 pages and are part of the certificate.


                 All calibrations have been conducted in the closed laboratory facility: environment temperature(@213)‘C and
                 humidity<70%.

                 Calibration Equipment used (M&TE critical for calibration)


                 Primary Standards                ID #                Cal Date(Calibrated by, Certificate No.)       Scheduled Calibration
                  Power Meter    NRP2             101919               01—Jul—17 (CTTL, No.J17X04256)                       Jun—18
                  Power sensor NRP—291            101547               01—Jul—17 (CTTL, No.J17X04256)                         Jun—18
                  Reference Probe EX3DV4          SN 7307              19—Feb—18(SPEAG,No.EX3—7307_Feb18)                     Feb—19
                  DAE4                            SN 771               02—Feb—18(CTTL—SPEAG,No.Z13—97011)                     Feb—19

                  Secondary Standards             ID #                 Cal Date(Calibrated by, Certificate No.)      Scheduled Calibration
                  Signal Generator E4438C         MY49071430           O1—Feb—18 (CTTL, No.J18X00893)                         Jan—19
                  Network Analyzer E5071C         MY46110673            26—Jan—18 (CTTL, No.J18X00894)                        Jan—19



                                                  Name                            Function                               Signature
                 Calibrated by:                  Zhao Jing                  SAR Test Engineer                             %{/

                 Reviewed by:                    Qi Dianyuan                 SAR Project Leader                    _..q;;.fi%/

                 Approved by:                    Lu Bingsong                 Deputy Director of the laboratory ;f} m(?; ¢ d

                                                                                                  Issued: Jun 17,    2018
                 This calibration certificate shall not be reproduced except in full without written approval of the fabsratory. —



                     Certificate No: Z18—97089                            Page 1 of 8




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                                                        @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                                                          2/ 400—003—0500
Tel:(86)755—26066440—       Fax:(86)755—26014772     Email:service@anbotek.com                                                         www.anbotek.com


Anbotek B¥ ET F¢]]
ebAO$               Anbotek Testing




                                  TT sbt.
                                     24—
                                 Add: No.51 Xueyuan Road, Haidian District, Beijing. 100191, China
                                 Tel: +86—10—62304633—2079      Fax: +86—10—62304633—2504
                                 E—mail: ettl@chinattl.com      Hitp:/Avwwchinattl.cn


                           Glossary:
                           TSL                    tissue simulating liquid
                           ConvF                   sensitivity in TSL / NORMx,y,z
                           N/A                    not applicable or not measured


                          Calibration is Performed According to the Following Standards:
                          a) IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak
                             Spatial—Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
                             Communications Devices: Measurement Techniques", June 2013
                          b) IEC 62209—1, "Procedure to measure the Specific Absorption Rate (SAR) For hand—held
                             devices used in close proximity to the ear (frequency range of 300MHz to 3GHz)", February
                             2005
                          6) IEC 62209—2, "Procedure to measure the Specific Absorption Rate (SAR) For wireless
                             communication devices used in close proximity to the human body (frequency range of
                             30MHz to 6GHz)", March 2010
                          d) KDB865664, SAR Measurement Requirements for 100 MHz to 6 GHz


                          Additional Documentation:
                          e) DASY4!5 System Handbook


                       Methods Applied and Interpretation of Parameters:
                       + Measurement Conditions: Further details are available from the Validation Report at the end
                          of the certificate. All figures stated in the certificate are valid at the frequency indicated.
                      * Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
                          point exactly below the center marking of the flat phantom section, with the arms oriented
                          parallel to the body axis.
                      * Feed Point impedance and Return Loss: These parameters are measured with the dipole
                          positioned under the liquid filled phantom. The impedance stated is transformed from the
                          measurement at the SMA connector to the feed point. The Return Loss ensures low
                          reflected power. No uncertainty required.
                      * Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
                          No uncertainty required.
                      «_ SAR measured: SAR measured at the stated antenna input power.
                          SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
                             connector.
                      «_     SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
                             nominal SAR result.


                            The reported uncertainty of measurement is stated as the standard uncertainty of
                            Measurement multiplied by the coverage factor k=2, which for a normal distribution
                            Corresponds to a coverage probability of approximately 95%.



                      Certificate No: Z18—97089                               Page 2 of 8




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                                  @ Hotline
Hangcheng Street, Bao‘an District, Shenzhen, Guangdong, China.                                                   °/ 400—003—0500
Tel:(86)755—26066440.—~      Fax:(86)755—26014772                   Email:service @anbotek.com                   www.anbotek.com


Anbotek B¥ ETF¢]]
Lcb e G3)          Anbotek Testing




                                                   s      In Collaboration with

                                      TTIL. _4
                                                          CALIBRATION LABORATORY

                            Add: No.51 Xugyuan Road, Haidian District, Beijing, 100191, Ching
                            Tel:   +86—10—62304633—2079      Fax:   +86—10—62304633—2504
                                    cttl@chinatil.com        Hitp:/www.chinatten


                     Measurement Conditions
                       DASY system confiquration, as far as not given on page 1.
                         DASY Version                                         DASY52                                       52.8.8.1258
                         Extrapolation                                Advanced Extrapolation

                         Phantom                                      Triple Flat Phantom 5.1C

                         Distance Dipole Center — TSL                         15 mm                                      with Spacer

                         Zoom Scan Resolution                             dx, dy. dz = 5 mm
                         Frequency                                        835 MHz & 1 MHz


                     Head TSL parameters
                       The following parameters and calculations were applied.
                                                                                  Temperature             Permittivity           Conductivity
                         Nominal Head TSL parameters                               22.0°C                    41.5                0.90 mho/m

                         Measured Head TSL parameters                         (22.0 2 0.2) °C              41.0 + 6 %          0.89 mho/m 4 6 %
                         Head TSL temperature change during test                   «1.0 °C                    ——                       —

                     SAR result with Head TSL
                         SAR averaged over 1 _Cm"_(1 g) of Head TSL                          Condition
                         SAR measured                                                  250 mW input power                    2.30 mW /q
                         SAR for nominal Head TSL parameters                              normalized to 1W          9.24 mW 1g + 20.8 % (k=2)

                         SAR averaged over 10. Cm1" (10 g) of Head TSL                       Condition
                         SAR measured                                                  250 mW input power                    1.50 mW /g

                         SAR for nominal Head TSL parameters                              normalized to 1W          6.02 mW Ig # 20.4 % (k=2)


                     Body TSL parameters
                       The following parameters and calculations were applied.
                                                                                  Temperature             Permittivity           Conductivity
                         Nominal Body TSL parameters                               22.0 °C                   55.2                0.97 mho/m
                         Measured Body TSL parameters                         (22.0 £0.2) °C               554 +6 %            0.99 mho/m + 6 %

                         Body TSL temperature change during test                   «10 °C                     ——                       —

                     SAR result with Body TSL
                         SAR averaged over 1_cm"_(1 g) of Body TSL                            Condition
                         SAR measured                                                  250 mW input power                    243 mW /g

                         SAR for nominal Body TSL parameters                               normalized to 1W         9.57 mW 1g * 20.8 % (k=2)

                         SAR averaged over 10 Cm" (10 g) of Body TSL                          Gondition
                         SAR measured                                                  250 mW input power                    161 mW /g
                         SAR for nominal Body TSL paramaters                               normalized to 1W         6.36 mW 1g £ 20.4 % (k=2)

                     Certificate No: Z18—97089                              Page 3 of 8




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                                                                 @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                                                                   2
                                                                                                                                                    400—003—0500
Tel:(86)755—26066440—       Fax:(86)755—26014772     Email:service@anbotek.com                                                                  www.anbotek.com


Anbotek B¥ ETF¢]]
Lcb e G3)          Anbotek Testing




                             i7777 a
                              *\
                            Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
                            Tel: +86—10—62304633—2079      Fuxc+86—10—62304633—2504
                            E—mail: eitl@chinattl.com      Hitpo//wwas chinattl.en


                     Appendix

                     Antenna Parameters with Head TSL

                         Impedance, transformed to feed point                                   49.20— 31110
                         Retum Loss                                                               —29.80B


                     Antenna Parameters with Body TSL

                         Impedance, transformed to feed point                                   46.60—2.3310

                         Return Loss                                                              —27.408


                     General Antenna Parameters and Design

                         Electrical Delay (one direction)                                         1.508 ns




                     After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can
                     be measured

                     The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly
                     connected to the second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some
                     of the dipoles, small end caps are added to the dipole arms in orderto improve matching when loaded
                     according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not
                     affected by this change. The overall dipole length is still according to the Standard.
                     No excessive force must be applied to the dipole arms, because they mignt bend orthe soldered
                     connections near the feedpoint may be damaged.



                     Additional EUT Data

                         Manufactured by                                                             SPEAG




                     Certificate No: 718—97089                             Page 4 of 8




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                                          @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                                            2
                                                                                                                             400—003—0500
Tel:(86)755—26066440—       Fax:(86)755—26014772     Email:service@anbotek.com                                           www.anbotek.com


Anbotek B¥ ET F¢]]
M Semeiip          Anbotek Testing



                                                         In Collaboration with
                                                         s       p       e       a      q
                                                         CALIBRATION LABORATORY

                             Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
        |                    Tel: +86—10—62304633—2079      Fax: +86—10—62304633—2504
        |                    E—mail: cttl@chinattl.com       Hitp://www.chinattl.en

                     DASYS Validation Report for Head TSL                                Date: 06.16.2018
                     Test Laboratory: CTTL., Beijing, China
                     DUT: Dipole 835 MHz; Type: D835V2; Serial; D835V2 — SN: 40154
                        Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
                        Medium parameters used: f= 835 MHz: a= 0.891 $/m; s = 40.97; p= 1000 kg,’nrxj
                        Phantom section: Right Section
                        Measurement Standard: DASYS (IEEE/IEC/ANSI €63.19—2007)
                     DASYS Configuration:

                                  «    Probe: EX3DV4 — SN7307; ConvP(10.01, 10.01,10.01); Calibrated: 2/19/2018;
                                  «+   Sensor—Surface: 2mm (Mechanical Surface Detection)
                                  *    Electronics: DAE4 Sn771; Calibrated: 2018—02—02
                                  +    Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA: Serial: 1161/1
                                  +    Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7372)

                             Dipole Calibration/Zoom Sean (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm,
                             dy=5mm, dz=Smm
                             Reference Value = 58.14¥/m; Power Drift = 0.02 dB
                             Peak SAR (extrapolated) = 3.41 W/kg
                             SAR(I g) =2.3 W/kg: SAR(IO g) = 1.5 W/kg
                              Maximum value of SAR (measured) = 2.91 W/kg

                                 d
                                 0


                                 213


                                 ~4.25


                                  —6.38


                                  —8.50


                                                t L
                                  —10.63                                                         F—
                                             0 dB =2.91 W/kg =4.64 dBW/kg




                       Certificate No: 218—97089                              Page 5 of8




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                                          »\   Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                                      °/        400—003—0500
Tel:(86)755—26066440      Fax:(86)755—26014772                    Email:service @anbotek.com                       www.anbotek.com


Anbotek B¥ET/
ebAO$               Anbotek Testing




                                Ti ies
                              Add: No.31 Xueyuan Rond, Haidian District, Beijing, 100191, China
                              Tel: +86—10—62304633—2070      Fax: +86—10—62304633—2504
                              E—mail: ctl@chinatt.com         Hitp!/wwwchinattl.en




                               Impedance Measurement Plot for Head TSL


                          Tri sif tog mag 10.00087 ner 0. ooods
                                                             [Fi]
                            s0.00 37— #35. 00000 wer —25. 785 do
                            46. 00
                            30. 00
                            20. 0o
                            10. 00
                            0.000
                           —10.00
                           —20.00
                           —30.c0
                            40. 00

                           —50.00
                          MBR stt smith (@+]x) scale 1.0000 [6l bel]
                            »1. 835,00000 mz 49. 186 n —3.3105 o 6«1.2'7}-(7771*-._




                      Certificate No: 218—97089                               Page 6 of 8




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building—D, Sogood Science and Technology Park, SanweiCommunity,                    @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                     2/ 400—003—0500
Tel:(86)755—26066440.—~      Fax:(86)755—26014772                   Email:service@anbotek.com     www.anbotek.com


Anbotek B¥ ET F¢]]
oo rasseiP         Anbotek Testing



        ‘                      %                         ;wtuborauonemm a




                             Add: No.51 Xueyuan Road, Haidian District, Beijing. 100191, China
                             Tel: +86—10—62304633—2079       Fasc: +86—10—62304633—2504
                             E—mail: cttl@chinattl.com       Hup://wwwchinattl en




        |             DASYS Validation Report for Body TSL                                       Date: 06.16.2018
        |            Test Laboratory: CTTL, Beijing, China
        |             DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 — SN: 44154
        |               Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1;1
                        Mediumparameters used: f= $35 MHz: 0 =0.991 $/m; s = 55.41; p = 1000 kg/m‘
                        Phantom section: Center Section
                        Measurement Standard: DASY3S (IEEE/IEC/ANSI C63.19—2007)
                      DASYS Configuration:

                                 +    Probe: EX3DV4 — SN7307; ConvF(9.83,9.83, 9.83); Calibrated: 2/19/2018;
                                 +    Sensor—Surface: 2mm (Mechanical Surface Detection)
                                 +    Electronics: DAE4 Sn771; Calibrated: 2018—02—02
                                 +    Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1161/1
                                 +    Measurement SW: DASY32, Version 52.8 (8); SEMCAD X Version 14.6.10 (7372)

                             Dipole Calibration/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurementgrid: dx=5mm,
                             dy=5mm.,dz=5mm
                             Reference Value = 54.01 V/m; Power Drift= 0.01 dB
                             Peak SAR (extrapolated) = 3.53 W/kg
                             SAR(I g) =2.43 Wikg: SAR(1O g) = L.61 W/kg
                             Maximum value of SAR (measured) = 3.04 W/kg


                                dB
                                0


                                 —1.99


                                 —3.98


                                 —5.96


                                 —7.95


                                 —9.94
                                            0 dB = 3.04 W/kg = 4.83 dBW/kg




                     Certificate No: Z18—97089                              Page 7 of8




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                                     @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                                          400—003—0500
Tel:(86)755—26066440.—~"    Fax:(86)755—26014772    Email:service@anbotek.com                                       www.anbotek.com


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 122 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 123 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 124 of 163


Report No.: SZAWW191010019-01   FCC ID:RQQHLT-L553TA   Page 125 of 163



Document Created: 2019-10-21 07:26:04
Document Modified: 2019-10-21 07:26:04

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC