TEST REPORT

FCC ID: RQQHLT-3000

Test Report

Download: PDF
FCCID_385214

EMC TEST REPORT



        FCC EVALUATION REPORT FOR CERTIFICATION

                                    KOREA Standard Technology

                                      Test report No.: KST-FCC0314



Manufacturer’s Name : Hyundai Corporation
Manufacturer’s Address : 140-2, Kye-Dong, Chongro-Gu, Seoul, 110-973, Korea

EUT’s:
 FCC ID                       :     RQQHLT-3000
 Product Name                :      LCD Monitor
 Model Number(s)               :    HLT-3000
 Product Options               :    N/A
 Category                     :     FCC Part 15 subpart B
                                                     Class B Computing Digital Device




Supplementary Information
The device bearing the brand name and FCC ID specified above has been shown to comply with the applicable
    technical standards as indicated in the measurement report and was tested in accordance with measurement
    procedures specified in ANSI C63.4-1992.
 I attest to the accuracy of data and all measurements reported herein were performed by or were made under my
    supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the
    completeness of these measurements and vouch for the qualifications of all persons taking them.

 Date : December 27, 2003.


                                                         Approved by:
 Tested by:


                                   Kim, Ha-Hyoung                                       Lee, Weon-Woo


EMC TEST REPORT
Report reference No: KST-FCC0314




                                                   Contents

     1. Description of Device

     2. Test Facility

     3. MAP

     4. Test system configuration

     5. Description of E.U.T.

     6. Summary of test results.

     7. Test results.

     8. Photographs.


Appendix. Schematics

            Specifications.




KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea      Page : 2of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                      December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314




     1. Description of Device

1) Kind of equipment:                               LCD Monitor
2) FCC ID:                                          RQQHLT-3000
3) Model Name:                                      HLT-3000
4) Serial No.:                                      None
5) Type of Sample Tested:                           Pre-production
6) High Frequency Used:                             8.000 / 12.000 / 13.500 MHz
                                                    18.432 / 20.250 / 25.000 MHz

7) Adapter                                          Model name: None
                                                    Manufacturer: None
                                                    Serial no: None

8) Power Rating:                                    1phase AC100-240V, 50/60Hz, 280W
                                                    Output: -

9) Tested Power supply:                             1phase AC120V, 60Hz
10) Date of Manufacture:                            November, 2003
11) Manufacture:                                    Hyundai Corporation


12) Description of Operating:                       Scroll All “H” Character
                                                    Resolution 1024*768 , Vertical Frequency: 75Hz


13) Dates of Test:                                  December 22, 2003
14) Place of Tests:                                 Korea Standard Technology EMC site
15) Test Report No:                                 KST-FCC0314




KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea                                      Page : 3of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                                                      December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314




     2. Test Facility

The open field test site and conducted measurement facility are used for these testing, where are
located following address and drawing. This site was fully described in a report dated November 14,
2002, that was submitted to the FCC.


Korea Standard Technology ( KOSTEC Co., Ltd)


Head office:
302 City Bild, 1600-3 Kwanyang-dong, Dongan-gu, Anyang-shi, Kyunggi-do, Korea
Telephone No : 82-31-388-2051
Facsimile No: 82-31-388-2052


Test Lab
:180-254, Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea
Telephone No : 82-31-222-4251
Facsimile No: 82-31-222-4252

MIC(Ministry of Information and Communication) No: KR0042

FCC Filing No. : 525762

VCCI Membership Number : 2005


VCCI Registration Number : R-1657 / C-1763




KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea                             Page : 4of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                                             December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314




     3. MAP
Korea




Hwasung-shi (open area test site)




                                                     KOSTEC Co., Ltd




KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea             Page : 5of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                             December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314




4. Test System Configuration
Operation Environment


                                                Temperature           Humidity
 Ambient                                                                               Pressure ( hPa )
                                                  ( °C )               (%)
 10m Open Area site                                  8.5                 38                  1019

 Shielded room:                                     13.8                 42                  1018



          Test site
          These testing were performed following locations ;

          Shielded room : Conducted Emission,

          10m Open Area Site: Radiated Emission



Measurement Uncertainty

          All measurements involve certain levels of uncertainties, especially in field of EMC.
          The factors contributing to uncertainties are test receiver, Cable loss, antenna factor calibration,
          Antenna directivity, antenna factor variation with height, antenna phase center variation,
          antenna frequency interpolation, measurement distance variation, ite imperfection, mismatch,
          and system repeatability.
          Based on NIS 80,81, The measurement uncertainty level with a 95% confidence level were
          applied.

sample calculation

           Conducted emission

          The field strength is calculated by adding the LISN factor, cable loss from the measured
          reading.
          The sample calculation is as follows:

          FS = MR + LF + CL
               MR = Meter Reading
               LF = LISN Factor
              CL = Cable Loss

          If MR is 30dB, LISN Factor 1dB, CL 1dB
          The result (MR) is
          30 + 1 + 1 = 32dBuV



KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea                                       Page : 6of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                                                       December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314



5. Description of E.U.T.

Product Description

Manufactured By:             Hyundai Corporation
Address:                     140-2, Kye-Dong, Chongro-Gu, Seoul, 110-973, Korea
Model:                       HLT-3000
Serial Number:               None

Configuration of EUT

     Description                   Manufacturer                  Model / Part #         Serial Number
     LCD Panel                  LG.PHILIPS LCD                    LC300W01             30034P3N02495
     Main Board               Hyundai Corporation                   LCD30                   None
    Power Board             Hae Pyung Eleactronics              U200-M30LZ10/B         H037ALA15020
   Inverter Board                        K.T.Y                     KLS-300                   2921
     OSD Board                Hyundai Corporation                       None                None
 Component Board                         K.J.Y                     LC-30IE10                None
    Tuner Board                          H.Y.J                     LC-30IU10                030819
       Speaker                Hyundai Corporation                       None                None
  Remote Control              Hyundai Corporation                       None                None


EUT Used cables

                                Length                                         Connection    Connection
Cable Type         Shield                        Ferrite   Connector
                                 (m)                                            Point 1       Point 2
                                                                               Main power
  POWER               Y            1.5              -      AC INLET                             EUT
                                                                                 source
  VGA In              Y            1.5            yes           D-sub             EUT           PC
  S-Video             Y            1.0             -             Din              EUT            -
    DVI               Y            1.0            Yes           D-sub             EUT            -
   Audio              Y            1.5             -            Jack              EUT         Speaker


Operating conditions

           The operating mode/system were as follows in details:

           Operating: After Connected from personal comput to E.U.T by RGB cable(D-sub 15 pin).
                      And then use to “H” pattern program for data transmission and continuously ‘H’
                      pattern displayed on the LCD Monitor.
KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea                                           Page : 7of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                                                           December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314




Peripherals
No            Description                     Manufacturer              Model / Part #        Serial Number
1               LCD TV                 Hyundai Corporation               HLT-3000                None
2              Speaker                  Hyundai Corporation                 None                  None
3          Remote Controller            Hyundai Corporation                 None                  None
4                 PC                             Hanmi                     HT-901                 None
5               Printer                           HP                      C2605A              SG55M1B0RN
6            Ac/dc adapter                        HP                     Deskwriter               None
7              Keyboard                        Samsung                   SEM-DT35              19063587
8               Mouse                          A4TECH                      OK-720                 None


E.U.T Test Configuration (example)




                                          1                                               2
                                                                4



                                                                    6
                                                                               5




                                                                                      8
                                3                  7




6. Summary of test results
Modification to the E.U.T.

      -    None


Result :    - PASS

KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea                                          Page : 8of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                                                          December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314



7. TEST RESULTS
7.1 Conducted emission

Measurement procedure

Mains
The measurements were performed in a shielded room. EUT was placed on a non-metallic table height
of 0.4m above the reference ground plane. They were folded back and forth forming a bundle 30cm to
40Cm long and were hanged at a 40cm height to the ground plane.
Each EUT power lead, except ground (safety) lead, were individually connected through a LISN to input
power source.
Both lines of power cord, hot and neutral, were measured.

Used equipment

                                                                                      Next
   Equipment             Model no.            Serial no.        Makers                               Used
                                                                                    cal date
  Test receiver            ESPI3               100109             R&S              2003.03.21          ⅹ
                         ESH2-Z5               100044             R&S              2003.04.25          ⅹ
     L.I.S.N.
                         ESH2-Z5               100147             R&S              2003.04.25          ⅹ

Measurement uncertainty

          Conducted Emission measurement                    : ± 2.4 (K=2)


Test data
  FREQ .          L E V E L (d B ㎶ )    L IN E     L o ss       L IM IT (d B ㎶ )        M AR G IN (d B ㎶ )

   (M H z)        QP           AV        Pol       (d B )       QP         AV            QP          AV

  0.154         54.35        50.01        N        0.08     66.00        56.00         11.73        6.07

  0.182         46.78        29.53        N        0.06     66.00        56.00         19.28       26.53

  0.306         46.34        32.86        L        0.29     66.00        56.00         19.95       23.43

  0.542         30.86        28.63        L        0.08     56.00        46.00         25.22       17.45

 12.346         33.38        28.04        L        0.43     60.00        50.00         27.05       22.39

 20.562         37.68        32.93        N        1.77     60.00        50.00         24.09       18.84

 24.674         34.30        29.64        N        2.20     60.00        50.00         27.90       22.56

* Level = test receiver reading value
* Loss = LISN insertion Loss + Cable Loss




KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea                                                Page : 9of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                                                                December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314



Conducted emission test graph
                                                Line. Live




                                              Line. Neutral




KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea    Page : 10of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                      December 27, 2003
http://www.kosteclab.com


EMC TEST REPORT
Report reference No: KST-FCC0314



7.2 Radiated Emission

Measurement procedure

A pretest was performed at 3m distances in a semi-anechoic chamber for searching correct frequency.
The final test was done at a 10m open area test site with a quasi-peak detector.
EUT was placed on a non-metallic table height of 0.8m above the reference ground plane.
Cables connected to EUT were fixed to cause maximum emission.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization.
The measurement antenna was varied in height above the conducting ground plane to obtain the
maximum signal strength.

Used equipment
                                                                                                             Next
               Equipment                        Model no.              Serial no.           Makers
                                                                                                            cal date
           Test receiver                        ESCS30                  100111              R&S            2004.3.17
    Ultra broadband antenna                      HL562                  100075              R&S            2004.3.18
        Matching network                          RAM                 358.5414.02           R&S                 -
          Antenna Mast                           AT14                    none             Daeil EMC             -
            Turn Table                           TT15                    none             Daeil EMC             -
       10m Open area site                         none                   none            KOSTEC Lab             -
          chamber(3m)                            none                    none            FRANCONIA              -

Measurement uncertainty
       Radiated Emission measurement      :
                                  30-300MHz +3.96dB / -4.04dB
                                  300-1000MHz +3.04dB / -3.00dB

Test data : ( “H” pattern scroll ) – PC Mode


   F re q       R e a d in g   P        H         A      A n te n n a C a b le L o s s     R e s u lt    L im it    M a rg in

  (M H z )     (d B u V /m ) (H /V )   (m )      ( . )     (d B )          (d B )        (d B u V /m )   (d B )       (d B )
  7 5 .3 6        1 9 .1 0     V       2 .0 0    260        7 .7 0         3 .0 0          2 9 .8 0      4 0 .0     1 0 .2 0

  1 6 1 .0 2      1 3 .9 4     H       3 .6 0    180        7 .4 8         4 .4 8          2 5 .9 0      4 3 .5     1 7 .6 0

  1 9 4 .0 5      1 5 .4 4     H       3 .2 0    170        7 .2 0         4 .8 6          2 7 .5 0      4 3 .5     1 6 .0 0

  3 7 7 .9 4      1 4 .6 7     H       3 .0 0    280       1 2 .9 1        7 .2 2          3 4 .8 0      4 6 .0     1 1 .2 0

  4 3 1 .9 2      1 3 .0 6     H       2 .7 0    160       1 4 .1 3        7 .7 1          3 4 .9 0      4 6 .0     1 1 .1 0

  6 0 0 .0 0       9 .6 0      V       1 .8 0    180       1 7 .0 0        9 .3 0          3 5 .9 0      4 6 .0     1 0 .1 0

  7 0 0 .0 0       9 .4 0      H       1 .9 0    220       1 8 .4 0       1 0 .0 0         3 7 .8 0      4 6 .0      8 .2 0
  8 0 0 .0 0       7 .1 0      H       1 .6 0    160       1 9 .6 0       1 0 .8 0         3 7 .5 0      4 6 .0      8 .5 0
Reading = Test receiver reading / P= antenna Polarization / H=antenna H
A=turn table Angle / Antenna = antenna factor / Cable loss = used cable loss
Result = reading + antenna + loss / Margin = Limit - result
* Receiving Antenna Mode: Horizontal, Vertical / * Test site: 3m Open area site



KOSTEC Co.,Ltd.
180-254,Annyung-Ri, Taean-Yup, Hwasung-shi, Kyunggi-do, Korea                                                       Page : 11of 25
Tel : +82-31-222-4251 Fax: +82-31-222-4252                                                                         December 27, 2003
http://www.kosteclab.com