MPE

FCC ID: RKXZIK2

RF Exposure Info

Download: PDF
FCCID_2394853

               Parrot Zik 2.0 MPE calculation
                              Model number: Parrot Zik 2.0
                              FCC ID RKXZIK2.0
                              IC: 5119A-ZIK2.0


According to FCC §15.247(b)(4) and §1.1307(b)(1), systems operation under the
provisions of this section shall be operated in a manner that ensures that the public is not
exposed to radio frequency energy level in excess of the Commission’s guidelines.

MPE Prediction

                 Frequency range (MHz)       Power density (mW/cm²)
                      400 – 1500                     f/2000
                     1500 - 100000                 1 mW/cm²



Equation for calculation

                                                 πR²)
                                     S = P*G / (4π
Where:         S – Power density
               P – Power input to antenna
               G – Antenna gain relative to isotropic radiator
               R – Distance to antenna

Maximum peak output power at antenna terminal: +5.22 dBm (3.3 mW)
Antenna gain: -2.35 dBi
Prediction distance: 20cm
MPE limit for General Population/Uncontrolled Exposure: 1 mW/cm²

Final results:

MPE safe distance: 0.39 cm
Power density at 20cm distance: 0.0004 mW/cm²


Best Regards



Document Created: 2014-09-13 12:05:37
Document Modified: 2014-09-13 12:05:37

© 2024 FCC.report