Test report c

FCC ID: RK7193-00

Test Report

Download: PDF
FCCID_4259871

FCC Measurement/Technical Report on

111 kHz Transceiver Wireless Power
Transfer

WCH-193c, 9J1.035.504.A



FCC ID: RK7193-00
IC:   4774A-19300



Report Reference:               MDE_LAIRD_1812_FCCa_rev1




 Test Laboratory:
 7layers GmbH
 Borsigstrasse 11
 40880 Ratingen
 Germany

 Note:
 The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
 without the written approval of the test laboratory.

 7layers GmbH                       Geschäftsführer/
 Borsigstraße 11                    Managing Directors:                Registergericht/registered:                           a Bureau Veritas
 40880 Ratingen, Germany            Frank Spiller                      Düsseldorf HRB 75554                                  Group Company
 T +49 (0) 2102 749 0               Bernhard Retka                     USt-Id.-Nr./VAT-No. DE203159652
 F +49 (0) 2102 749 350             Alexandre Norré-Oudard             Steuer-Nr./TAX-No. 147/5869/0385                      www.7layers.com


 Commerzbank AG     Account No. 303 016 000 Bank Code 300 400 00    IBAN DE81 3004 0000 0303 0160 00 Swift Code COBADEFF


Table of Contents
1     Summary                                                      3
      1.1    Technical Report Summary                              3
      1.2    FCC-IC Correlation Table                              4
      1.3    Measurement Summary / Signatures                      5
      1.4    Revision History                                      6
2     Administrative Data                                          7
      2.1    Testing Laboratory                                    7
      2.2    Project Data                                          7
      2.3    Applicant Data                                        7
      2.4    Manufacturer Data                                     7

3     Test object Data                                             8
      3.1    General EUT Description                               8
      3.2    EUT Main components                                   9
      3.3    Ancillary Equipment                                   9
      3.4    Auxiliary Equipment                                   9
      3.5    EUT Setups                                           10
      3.6    Operating Modes                                      10
      3.7    Special software used for testing                    10
      3.8    Product labelling                                    10

4     Test Results                                               11
      4.1    Spurious radiated emissions                          11
      4.2    Peak power output                                    18
      4.3    Occupied bandwidth                                   20
5     Test equipment                                             22
6     Antenna Factors, Cable Loss and Sample Calculations        25
      6.1    LISN R&S ESH3-Z5 (150 kHz – 30 MHz)                  25
      6.2    Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)                 26
      6.3    Antenna R&S HL562 (30 MHz – 1 GHz)                   27
      6.4    Antenna R&S HF907 (1 GHz – 18 GHz)                   28
      6.5    Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)             29
      6.6    Antenna EMCO 3160-10 (26.5 GHz – 40 GHz)             30
7     Setup Drawings                                             31
8     Measurement uncertainty                                    31
9     Photo Report                                               31




Test report reference: MDE_LAIRD_1812_FCCa_rev1             Page 2 of 31


1    Summary
1.1 Technical Report Summary

Type of Authorization

Certification for an intentional radiator: 111 kHz transmitter and load modulation system

Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR
Ch.1 Parts 2 and 15 (10-1-17 Edition). The following subparts are applicable to the results in
this test report.

Part 2, Subpart J – Equipment Authorization Procedures, Certification


Part 15, Subpart C – Intentional Radiators

§ 2.1049   Occupied bandwidth

§ 15.205   Restricted bands of operation

§ 15.207   Conducted limits

§ 15.209   Radiated emission limits; general requirements



Note:
ANSI C63.10-2013 is applied.




Summary Test Results:

The EUT complied with all performed tests as listed in sub-clause 1.3 Measurement
Summary / Signatures.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                     Page 3 of 31


1.2 FCC-IC Correlation Table


WPT Devices


Measurement                       FCC reference       IC reference
Conducted emissions on AC         § 15.207            RSS-216 Issue 2: 6.2.2.1
Mains                                                 ICES-001 Issue 4: 4, 5, 7.1.1
                                                      CAN/CSA-CEI/IEC CISPR 11:04
Transmitter spurious radiated     § 15.209            RSS-216 Issue 2: 6.2.2.2
emissions                                             ICES-001 Issue 4: 4, 5, 7.1.1
                                                      CAN/CSA-CEI/IEC CISPR 11:04
Restricted Bands                  § 15.205            RSS-Gen Issue 5: 8.10
                                                      RSS-216 Issue 2: 6.2.3
Wanted Emission (Carrier)         § 15.209            RSS-216 Issue 2: 6.2.2.2
                                                      ICES-001 Issue 4: 4, 5, 7.1.1
                                                      CAN/CSA-CEI/IEC CISPR 11:04
Other requirements, e.g.          –                   RSS-Gen Issue 5: 6.11/8.11
Transmitter frequency stability
Receiver spurious emissions       –                   RSS-216 Issue 2: 6.2.2.1
                                                      ICES-001 Issue 4: 4, 5, 7.1.1
                                                      CAN/CSA-CEI/IEC CISPR 11:04
Occupied bandwidth                § 2.1049            RSS-Gen Issue 5: 6.7


Notes:
This EUT is classified as WPT Transmitter Type 1.
Precise / exhaustive versions of the Standards:
ICES-001: ICES-001, Issue 4, June 2006, updated November 2014
CISPR 11: CAN/CSA-CEI/IEC CISPR 11:04 (R2013): “This National Standard of Canada is
equivalent to International Standard CEI/IEC CISPR 11:2003.”
Publish date: 2004-06-01, Reaffirmed: 2013-09-11
Applied Standard: IEC CISPR 11:2003 + A1:2004, Edition 4.1, 2004-06




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                Page 4 of 31


1.3 Measurement Summary / Signatures

47 CFR Chapter I FCC Part 15, Subpart C     §15.209
Radiated Emissions
The measurement was performed according to ANSI C63.10
OP-Mode            Setup         Port                               Final Result
WPT_act            Setup_02      Enclosure                          passed

47 CFR Chapter I FCC Part 15, Subpart C     §15.209
Peak Output Power
The measurement was performed according to ANSI C63.10
OP-Mode           Setup          Port                               Final Result
WPT_act           Setup_02       Enclosure                          passed

47 CFR Chapter I FCC Part 15, Subpart C        §15.207
Conducted Emissions AC Power line
The measurement shall be performed according to ANSI C63.10
OP-Mode            Setup          Port                              Final Result
‒                  ‒              ‒                                 N/A (1)

47 CFR Chapter I FCC Part 2, Subpart J       §2.1049
Occupied Bandwidth
The measurement was performed according to ANSI C63.10
OP-Mode            Setup         Port                               Final Result
WPT_act            Setup_02      Enclosure                          performed

RSS-Gen                                        6.11/8.11
Frequency Stability
The measurement shall be performed according to ANSI C63.10
OP-Mode             Setup         Port                              Final Result
‒                   ‒             ‒                                 N/A (2)

Notes:

N/A = Not applicable
(*)    Tested in the frequency range 9 kHz to 30 MHz.
(1)    The EUT is DC powered. It is only intendent for the use in vehicles.
(2)    Not required per 8.11.
performed = no limit is applicable to the test result.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                    Page 5 of 31


                                                                                     layers
                                                                                     A Bureau Veritas Group Company


1.4 Revision History


 Version           Release date      Change Description                               Version validity
 initial           2019—02—15        —=                                               invalid
 revi              2019—04—25        e Note added to the EUT setups                   valid
                                        explaining the usage of a "spacer" to
                                          represent possible worst—case
                                          conditions.
                                     *    Removal of ping mode and all related
                                          items, as requested by the TCB, i.e.:
                                          Removal of Setup_01, EUT A and the
                                          related results.
                                     «_   Change of WPT Transmitter Type from
                                          3 to 1, as declared by ISED answer on
                                          2016—04—13 to an inquiry to
                                          "ConsultationRadioStandards—
                                          ConsultationNormesRadio (IC)".
                                     e    Adding ISED CAB Identifier at
                                          Administrative Data




Responsible for         b@       )             ~    Responsible              Q
Accreditation Scope:         ‘                      for Test Report:             ©




                                          7layers
                                              7 layers GmbH, Borsigstr. 11
                                              40880 Ratingen, Germany
                                              Phone +49 (0)2102 749 0




Test report reference: MDE_LAIRD_1812_FCCa_revi                                                   Page 6 of 31


2    Administrative Data
2.1 Testing Laboratory
Company Name:                            7layers GmbH

Address:                                 Borsigstr. 11
                                         40880 Ratingen
                                         Germany

This facility has been fully described in a report submitted to the FCC and accepted under
the registration number 96716 and IC(ISED) under the registration number: Site# 3699A-1
The test facility is also accredited by the following accreditation organisation:
Laboratory accreditation no:             DAkkS D-PL-12140-01-00

FCC Designation Number:                  DE0015

FCC Test Firm Registration:              929146

ISED CAB Identifier                      DE0007

Responsible for accreditation scope:     Dipl.-Ing. Daniel Gall


Report Template Version:                 2019-01-22

2.2 Project Data
Responsible for testing and report:      Dipl.-Ing. Andreas Petz

Employees who performed the tests:       documented internally at 7Layers

Date of Report:                          2019-04-25

Testing Period:                          2019-01-04 to 2019-02-11

2.3 Applicant Data
Company Name:                            Laird Dabendorf GmbH

Address:                                 Märkische Strasse 72
                                         15806 Zossen
                                         Germany
Contact Person:                          Mr. Heiko Dörschel

2.4 Manufacturer Data
Company Name:                            please see applicant data

Address:


Contact Person:




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                     Page 7 of 31


3    Test object Data
3.1 General EUT Description

Equipment under Test                Wireless Power Transfer System, Power
                                    Transmitter
Product Name                        Wireless Charger WCH-193c, 9J1.035.504.A
Type Designation:                   WCH-193
Kind of Device:                     111 kHz Transceiver Wireless Power Transfer
Voltage Type:                       DC
Voltage level:                      12 V nominal and tested voltage


3.1.1. General product description:

The EUT is a wireless power transmitter operating as transceiver according to the Qi-Standard
on 111 kHz. It will be integrated by professionals in vehicles in vertical position.


According to applicant's information:

WCH-193c is a Wireless Charging Unit (WCU), i.e. a phone cradle which provides wireless
charging technology in accordance with the WPC Qi 1.3 standard and antenna coupling to a
mobile phone. The charging function is started after the WCU has obtained a successful
response from the receiver towards a ping cycle initiated by the WCU. A ping cycle can be
started immediately from the WCU due to object changing detected by a proximity sensor (CAP
sensor) or after a certain, defined time (1 minute), depending on the state of the WCU. After a
successful response the mobile phone has communicated to the WCU that it is chargeable
according to the Qi wireless charging standard.


3.1.2. Specific product description for the EUT:

For a detailed description please refer to the documentation provided by the applicant.


3.1.3. The EUT provides the following ports:

   Enclosure
   DC connector
   CAN bus
   FAKRA output from passive antenna coupler
   KESSY signal




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                     Page 8 of 31


3.2 EUT Main components

Type, S/N, Short Descriptions etc. used in this Test Report

Short Description Equipment under Type Designation               Serial No.    HW Status      SW Status
                         Test
  EUT B (Code:     Wireless Charger   WCH-193                   000002B70018     H03             0002
 DE1340001ad01)      WCH-193c,
                    9J1.035.504.A

Note: The short description is used to simplify the identification of the EUT in this test report.



3.3 Ancillary Equipment

For the purposes of this test report, ancillary equipment is defined as equipment which is used
in conjunction with the EUT to provide operational and control features to the EUT. It is
necessary to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Ancillary Equipment can influence the test results.

Short Description Equipment under Type Designation               Serial No.    HW Status      SW Status
                       Test
        –               –                –                           –             –                  –



3.4 Auxiliary Equipment

For the purposes of this test report, auxiliary equipment is defined as equipment which is used
temporarily to enable operational and control features especially used for the tests of the EUT
which is not used during normal operation or equipment that is used during the tests in
combination with the EUT but is not subject of this test report. It is necessary to configure the
system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

Short Description          Device         Type Designation       Serial No.    HW Status      SW Status
      AUX 1          WPT Test Receiver Novero, EMC WCH            SN 0003        V.3.4            –
                     with 5 W artificial     testreceiver
                            load             DAB15131E
      AUX 2         Bias-Tee incl. loads: Mini-Circuits ZFBT-   R UU34901805       –                  –
                      50 ohm at RF &              6G+
                       10 kohm at DC




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                      Page 9 of 31


3.5 EUT Setups

This chapter describes the combination of EUTs and equipment used for testing. The rationale
for selecting the EUTs, ancillary and auxiliary equipment and interconnecting cables, is to test
a representative configuration meeting the requirements of the referenced standards.

  Setup No.        Combination of EUTs                          Description and Rationale
  Setup_02         EUT B + AUX 1 + AUX 2         EUT B has a special firmware variant providing “charging”
                                                  mode for the test purpose (the power receiver does not
                                                 contain any kind of battery, charging current is constant);
                                                            AUX 2 terminates the port “FAKRA”


Note:
The tests have been carried out using an additional “spacer” between the EUT and AUX1:
Close contact to power transmitter, central position, separated by dedicated plastic support
and for test purpose additional 6 mm spacer (pressboard).
This setup has been chosen in order to represent the “worst-case” positioning (max. distance
between EUT and AUX1) that generates the highest, “worst-case” emissions, simulating if a
smartphone is used together with a customer-added protective bag (pouch, case, sleeve, flip
case, cover, outdoor bumper), which has not been excluded by the applicant.
The same “worst-case” set-up is used as requested by ETSI EN 303 417 V1.1.1 (2017-09).


3.6 Operating Modes

This chapter describes the operating modes of the EUTs used for testing.

Op. Mode      Description of Operating Modes          Remarks
WPT_act       Maximum power is transferred from the   EUT is transmitting continuously at 111 kHz and
              EUT to AUX 1                            information between the AUX 1 and the EUT is
                                                      exchanged by load modulation



3.7 Special software used for testing

Variants of the normal firmware are used to provide the desired operating modes without the
necessity of maintaining a CAN bus connection.


3.8 Product labelling

Please refer to the documentation of the applicant.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                   Page 10 of 31


4    Test Results
4.1 Spurious radiated emissions

Standard FCC Part 15, Subpart C

The test was performed according to: ANSI C63.10

4.1.1. Test Description

The test set-up was made in accordance to the general provisions of ANSI C63.10 in a typical
installation configuration. The Equipment Under Test (EUT) was set up on a non-conductive
table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT support table that
is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software EMC32 from R&S.
(Exploratory) Tests are performed at 2 orthogonal EUT orientations (vertical and horizontal) to
determine the worst-case EUT orientation. In combination with the turntable rotation,
emissions of at least 3 orthogonal axes are detected.

1. Measurement up to 30 MHz
The Loop antenna HFH2-Z2 is used.

Step 1: pre measurement
• Anechoic chamber
• Antenna distance: 3 m
• Antenna height: 1 m (lowest part to ground)
• Detector: Peak-Maxhold
• Frequency range: 0.009 - 0.15 MHz and 0.15 – 30 MHz
• Frequency steps: 0.05 kHz and 2.25 kHz
• IF–Bandwidth: 0.2 kHz and 9 kHz
• Measuring time / Frequency step: 100 ms (FFT-based)
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: final measurement
For the relevant emissions determined in step 1, an additional measurement will be performed
with the following changed settings. Intention of this step is to find the maximum emission
level.
• Detector: Quasi-Peak besides 9–90 kHz and 110–490 kHz: Average and Peak
• Measuring time / Frequency step: 1 s




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                     Page 11 of 31


2. Measurement above 30 MHz and up to 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
• Antenna distance: 3 m
• Detector: Peak-Maxhold / Quasipeak (FFT-based)
• Frequency range: 30 – 1000 MHz
• Frequency steps: 30 kHz
• IF–Bandwidth: 120 kHz
• Measuring time / Frequency step: 100 ms
• Turntable angle range: –180° to 90°
• Turntable step size: 90°
• Height variation range: 1 – 3 m
• Height variation step size: 2 m
• Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 45° around this value. During this action,
the value of emission is continuously measured. The turntable azimuth at the highest emission
will be recorded and adjusted. In this position, the antenna height will also slowly vary by ±
100 cm around the antenna height determined. During this action, the value of emission is
also continuously measured. The antenna height of the highest emission will also be recorded
and adjusted.
• Detector: Peak – Maxhold
• Measured frequencies: in step 1 determined frequencies
• IF – Bandwidth: 120 kHz
• Measuring time: 100 ms
• Turntable angle range: ± 45 ° around the determined value
• Height variation range: ± 100 cm around the determined value
• Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with QP detector
With the settings determined in step 2, the final measurement will be performed:
EMI receiver settings for step 3:
• Detector: Quasi-Peak (< 1 GHz)
• Measured frequencies: in step 1 determined frequencies
• IF – Bandwidth: 120 kHz
• Measuring time: 1 s

After the measurement a plot will be generated. It contains a diagram with the results of the
preliminary scan and a chart with the frequencies and values of the results of the final
measurement.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                     Page 12 of 31


4.1.2. Test Requirements / Limits

1) FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

                                       Measurement
Frequency in MHz   Limit (µV/m)                        Limit (dBµV/m)
                                       distance (m)
0.009 – 0.49       2400/F(kHz)@300m    3               (48.5 – 13.8)@300m
0.49 – 1.705       24000/F(kHz)@30m    3               (33.8 – 23.0)@30m
1.705 – 30         30@30m              3               29.5@30m


The measured values are corrected with an inverse linear distance extrapolation factor (40
dB/decade) according FCC §15.31 (2).

                                       Measurement
Frequency in MHz   Limit (µV/m)                        Limit (dBµV/m)
                                       distance (m)
30 – 88            100@3m              3               40.0@3m
88 – 216           150@3m              3               43.5@3m
216 – 960          200@3m              3               46.0@3m
960 - 26000        500@3m              3               54.0@3m
26000 - 40000      500@3m              1               54.0@3m


§15.35(b)
..., there is also a limit on the radio frequency emissions, as measured using instrumentation
with a peak detector function, corresponding to 20 dB above the maximum permitted average
limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)


2) RSS-216, 6.2.2.2, Radiated Emission Limits

The raw values obtained at the measurement distance are extrapolated to the FCC’s definition
distance. The limits defined in RSS-216 are calculated for these FCC’s distances in order to
include the limits directly in one measurement plot and to demonstrate if compliance is
achieved. The verdict related to RSS-216 is basing on the margin which is constant for
different distances and i.e. is not altered by these linear transformations.

Limits CISPR 11, table 3b for induction cooking (group 2) equipment:
                    Limit (RSS-216)    Measurement     Limit (dBµV/m)
Frequency in MHz                                                              Frequency in MHz
                    (dBµA/m) @3m       distance (m)    @ FCC distance
0.009 – 0.070       69                 3               (40.5)@300m            0.009 – 0.070
0.070 – 0.1485      69 – 39 *)         3               (40.5 – 10.5)@300m     0.070 – 0.1485
0.1485 – 4.0        39 – 3 *)          3               (10.5 – -2.5)@300m     0.1485 – 0.49
                                                       (37.5 – 14.5)@30m      0.49 – 4.0
4.0 – 30.0          3                  3               (14.5)@30m             4.0 – 30.0


*) Decreasing linearly with logarithm of frequency

The alternate 60 cm loop test method and corresponding limits for small residential WPT
devices is used for the tests in the frequency range 9 kHz – 30 MHz.

The measured field strength is extrapolated to the distance specified using the formula
indicating that the field strength varies as the inverse distance square (40 dB per decade of
distance), according to RSS-Gen, 6.5.
For fractal values of definition and reference distance the factor of 40*LOG10(dref/ddef) applies.
Relation between electrical and magnetic field strength: dBµV = dBµA + 51.5 dB.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                       Page 13 of 31


Limits CISPR 11, table 4 for group 2 class B equipment (quasi-peak limits):
                    Limit (RSS-216)   Measurement    Limit (dBµV/m)
Frequency in MHz
                    (dBµV/m) @10m     distance (m)   @ FCC distance
30 – 80.872         30                3              40.5@3m
80.872 – 81.848     50                3              60.5@3m
81.848 – 134.786    30                3              40.5@3m
134.786 – 136.414   50                3              60.5@3m
136.414 – 230       30                3              40.5@3m
230 – 1000          37                3              47.5@3m


Transformation of the limit at 10 m to the distance of 3 m: 20*LOG10(10m/3m) = 10.5 dB




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                Page 14 of 31


4.1.3. Test Protocol

Temperature:         23 °C
Air Pressure:        1030 hPa
Humidity:            41 %

Measurement up to 30 MHz

Op. Mode             Setup                      Port
WPT_act              Setup_02                   Enclosure
Antenna      EUT         Fre-          Corrected value         Limit     Limit     Limit     Margin      Margin
 orien-     orien-      quency            dBµV/m              dBµV/     dBµV/     dBµV/       dB          dB
 tation     tation       MHz                                     m         m         m
                                    QP      Peak      AV        QP       Peak       AV      QP/Peak        AV
   –          –           –          –        –        –         –         –         –         –            –

Remark:   The margin is related to the FCC limits. Margin related to RSS-216 limits is given in sub-clause 4.1.4.


Measurement above 30 MHz

Op. Mode             Setup                      Port
WPT_act              Setup_02                   Enclosure
Antenna      EUT         Fre-          Corrected value         Limit     Limit     Limit     Margin      Margin
 orien-     orien-      quency            dBµV/m              dBµV/     dBµV/     dBµV/       dB          dB
 tation     tation       MHz                                     m         m         m
                                    QP      Peak      AV        QP       Peak       AV      QP/Peak        AV
   –          –           –          –        –        –         –         –         –         –            –

Remark:   None.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                         Page 15 of 31


4.1.4. Measurement Plots (worst case)

Below 30 MHz, Setup_02


                         70
                         60

                         50
                         40
                                FCC_15.209_Peak@300m_9kHz-490kHz
                                                              FCC_15.209_QP@300m@30m_90kHz-30MHz
                         30
                         20
                                 FCC_15.209_AV@300m_9kHz-490kHz RSS_216_QP@300m@30m_9kHz-30MHz
       Level in dBµV/m




                         10
                          0

                         -10                             332.50 kHz
                                                   -22.2 dBµV/m (23.9 dB)
                         -20

                         -30
                         -40

                         -50

                         -60

                         -70


                           9k      20 30   50   100k   200 300 500     1M   2M 3M   5M   10M   20 30M
                                                          Frequency in Hz


Note: The marker shows the margin to the RSS-216 limit (in brackets).




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                Page 16 of 31


Above 30 MHz, Setup_02


                         65

                         60

                         55                                          FCC_15.209_30M-1GHz@3m

                         50            RSS216_ICES001_CISPR11_EN55011_Group2_ClassB_QP@3m
                         45

                         40
       Level in dBµV/m




                         35

                         30

                         25

                         20

                         15

                         10

                         5

                         0


                         30M   50 60   80 100M           200       300   400 500     800   1G
                                                 Frequency in Hz




4.1.5. Test Equipment used
        - Radiated Emissions




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                       Page 17 of 31


4.2 Peak power output

Standard FCC Part 15, Subpart C

The test was performed according to: ANSI C63.10


4.2.1. Test Description
Please refer to sub-clause 4.1.1.


4.2.2. Test Limits
Please refer to sub-clause 4.1.2.


4.2.3. Test Protocol

Temperature:           23 °C
Air Pressure:          1030 hPa
Humidity:              41 %

Op. Mode               Setup                       Port
WPT_act                Setup_02                    Enclosure
 Antenna        EUT orien-    Frequency       Maximum radiated field strength at         Limit         Margin
  orien-          tation         kHz          fundamental frequency (corrected)         dBµV/m          dB
  tation                                                  dBµV/m
                                                          AV = PK                          AV             AV
  Parallel        Vertical      111.10                       12.2                         26.7           14.5

Remark:      The margin is related to the FCC limits. Margin related to RSS-216 limits is given in sub-clause 4.2.4.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                            Page 18 of 31


4.2.4. Measurement Plot (worst case)

Setup_02


                           70
                           60

                           50                                                              FCC_15.209_Peak@300m_9kHz-490kHz
                           40

                           30 FCC_15.209_QP@300m@30m_90kHz-30MHz                             FCC_15.209_AV@300m_9kHz-490kHz
                           20
                                                                                          RSS_216_QP@300m@30m_9kHz-30MHz
         Level in dBµV/m




                           10

                            0                111.10 kHz
                                        12.2 dBµV/m (9.8 dB)
                           -10
                           -20

                           -30
                           -40

                           -50

                           -60

                           -70


                             110               115                  120              125                130                 135                140
                                                                               Frequency in kHz


Final_Result
 Frequency                  MaxPeak          Average      Limit      Margin      Meas.     Bandwidth     Height       Pol    Azimu     Corr.
   (MHz)                    (dBµV/m)        (dBµV/m)     (dBµV/       (dB)       Time        (kHz)        (cm)                 th     (dB/m)
                                                           m)                    (ms)                                        (deg)
   0.111100                           ---       12.22       26.71      14.49     1000.0         0.200     100.0   V          -187.0     -59.6
   0.111100                        12.23           ---      46.71      34.48     1000.0         0.200     100.0   V          -187.0     -59.6


Note: The marker shows the margin to the RSS-216 limit (in brackets).



4.2.5. Test Equipment used
        - Radiated Emissions




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                                                        Page 19 of 31


4.3 Occupied bandwidth

Standard FCC Part 2, Subpart J, §2.1049

The test was performed according to: ANSI C63.10


4.3.1. Test Description
The Equipment Under Test (EUT) was setup in a shielded room to perform the occupied
bandwidth measurements.
The results recorded were measured with the modulation which produces the worst-case
(widest) occupied bandwidth.


4.3.2. Test Requirements / Limits
FCC Part 15, Subpart C, §15.209 does not contain any requirement related to the bandwidth.


4.3.3. Test Protocol

Temperature:       24 °C
Air Pressure:      1018 hPa
Humidity:          34 %

Op. Mode           Setup              Port
WPT_act            Setup_02           Enclosure
20 dBc bandwidth    99% occupied
                     bandwidth
    0.05 kHz          0.04 kHz




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                Page 20 of 31


4.3.4. Measurement Plot (worst case)

20 dBc Bandwidth and 99% Occupied Bandwidth, Setup_02




4.3.5. Test Equipment used
        - Radiated Emissions




Test report reference: MDE_LAIRD_1812_FCCa_rev1         Page 21 of 31


5     Test equipment

1     Radiated Emissions
      Lab to perform radiated emission tests

Ref. Device Name Description        Manufacturer Serial Number            Last     Calibration
No.                                                                    Calibration     Due
1.1   NRV-Z1        Sensor Head A Rohde & Schwarz       827753/005     2018-07    2019-07
                                   GmbH & Co. KG
1.2 MFS             Rubidium       Datum GmbH           002            2018-10    2019-10
                    Frequency
                    Normal MFS
1.3 Opus10 TPR      ThermoAirpres Lufft Mess- und       13936          2017-04    2019-04
     (8253.00)      sure           Regeltechnik GmbH
                    Datalogger 13
                    (Environ)
1.4 ESW44           EMI Test       Rohde & Schwarz      101603         2018-05    2019-05
                    Receiver       GmbH & Co. KG
1.5 Anechoic        10.58 x 6.38 x Frankonia            none           2018-06    2020-06
     Chamber        6.00 m³
1.6 FS-Z60          Harmonic       Rohde & Schwarz      100178         2016-12    2019-12
                    Mixer 40 - 60 Messgerätebau
                    GHz            GmbH
1.7 FS-Z220         Harmonic       Rohde & Schwarz      101005         2017-03    2020-03
                    Mixer 140 -    Messgerätebau
                    220 GHz        GmbH
1.8 SGH-05          Standard Gain                       075
                    / Pyramidal
                    Horn Antenna
                    (140 - 220
                    GHz)
1.9 HL 562          Ultralog new Rohde & Schwarz        830547/003     2018-07    2021-07
                    biconicals
1.10 5HC2700/12750 High Pass       Trilithic            9942012
     -1.5-KK        Filter
1.11 ASP 1.2/1.8-10 Antenna Mast Maturo GmbH            -
     kg
1.12 Fully Anechoic 8.80m x        Albatross Projects   P26971-647-001- 2018-06   2020-06
     Room           4.60m x                             PRB
                    4.05m (l x w x
                    h)
1.13 Fluke 177      Digital        Fluke Europe B.V.    86670383       2018-04    2020-04
                    Multimeter 03
                    (Multimeter)
1.14 NRVD           Power Meter Rohde & Schwarz         828110/016     2018-07    2019-07
                                   GmbH & Co. KG
1.15 HF 906         Double-ridged Rohde & Schwarz       357357/002     2018-09    2021-09
                    horn
1.16 JS4-18002600- Broadband       Miteq                849785
     32-5P          Amplifier 18
                    GHz - 26 GHz
1.17 FSW 43         Spectrum       Rohde & Schwarz      103779         2016-12    2018-12
                    Analyzer
1.18 3160-09        Standard Gain EMCO Elektronic       00083069
                    / Pyramidal    GmbH
                    Horn Antenna
                    26.5 GHz




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                    Page 22 of 31


Ref. Device Name Description           Manufacturer Serial Number            Last     Calibration
No.                                                                       Calibration     Due
1.19 SGH-19            Standard Gain                     093
                       / Pyramidal
                       Horn Antenna
                       (40 - 60 GHz)
1.20 WHKX 7.0/18G-     High Pass      Wainwright         09
     8SS               Filter
1.21 4HC1600/12750     High Pass      Trilithic          9942011
     -1.5-KK           Filter
1.22 Chroma 6404       AC Power       Chroma ATE INC.    64040001304
                       Source
1.23 JS4-00102600-     Broadband      Miteq              619368
     42-5A             Amplifier 30
                       MHz - 26 GHz
1.24 TT 1.5 WI         Turn Table     Maturo GmbH        -
1.25 HL 562 Ultralog   Log.-per.      Rohde & Schwarz    100609           2016-04    2019-04
                       Antenna
1.26 HF 906            Double-ridged Rohde & Schwarz     357357/001       2018-03    2021-03
                       horn
1.27 FS-Z325           Harmonic       Rohde & Schwarz    101006           2017-03    2020-03
                       Mixer 220 -    Messgerätebau
                       325 GHz        GmbH
1.28 3160-10           Standard Gain EMCO Elektronic     00086675
                       / Pyramidal    GmbH
                       Horn Antenna
                       40 GHz
1.29 SGH-08            Standard Gain                     064
                       / Pyramidal
                       Horn Antenna
                       (90 - 140
                       GHz)
1.30 SGH-12            Standard Gain                     326
                       / Pyramidal
                       HornAntenna
                       (60 - 90 GHz)
1.31 5HC3500/18000     High Pass      Trilithic          200035008
     -1.2-KK           Filter
1.32 FS-Z140           Harmonic       Rohde & Schwarz    101007           2017-02    2020-02
                       Mixer 90 -140 Messgerätebau
                       GHz            GmbH
1.33 HFH2-Z2           Loop Antenna Rohde & Schwarz      829324/006       2018-01    2021-01
1.34 Opus10 THI        ThermoHygro Lufft Mess- und       12482            2017-03    2019-03
     (8152.00)         Datalogger 12 Regeltechnik GmbH
                       (Environ)
1.35 ESR 7             EMI Receiver / Rohde & Schwarz    101424           2019-01    2020-01
                       Spectrum
                       Analyzer
1.36 JS4-00101800-     Broadband      Miteq              896037
     35-5P             Amplifier 30
                       MHz - 18 GHz
1.37 AS 620 P          Antenna mast HD GmbH              620/37
1.38 Tilt device       Antrieb        Maturo GmbH        TD1.5-
     Maturo            TD1.5-10kg                        10kg/024/37907
     (Rohacell)                                          09
1.39 SGH-03            Standard Gain                     060
                       / Pyramidal
                       Horn Antenna
                       (220 - 325
                       GHz)



Test report reference: MDE_LAIRD_1812_FCCa_rev1                                       Page 23 of 31


Ref. Device Name Description             Manufacturer Serial Number           Last     Calibration
No.                                                                        Calibration     Due
1.40 FS-Z90            Harmonic         Rohde & Schwarz     101686        2017-03     2020-03
                       Mixer 60 - 90    Messgerätebau
                       GHz              GmbH
1.41   ESIB 26         Spectrum         Rohde & Schwarz     830482/004    2018-01     2020-01
                       Analyzer
1.42   PAS 2.5 - 10 kg Antenna Mast     Maturo GmbH         -
1.43   AFS42-          Broadband        Miteq               2035324
       00101800-25-S- Amplifier 25
       42              MHz - 18 GHz
1.44   AM 4.0          Antenna mast     Maturo GmbH         AM4.0/180/1192
                                                            0513
1.45 HF 907            Double-ridged Rohde & Schwarz        102444         2018-07    2021-07
                       horn



2      R&S TS8997
       Lab to perform bandwidth test

Ref. Device Name Description             Manufacturer Serial Number           Last     Calibration
No.                                                                        Calibration     Due
2.1    SMB100A         Signal           Rohde & Schwarz     107695        2017-07     2020-07
                       Generator 9
                       kHz - 6 GHz
2.2    MFS             Rubidium         Datum-Beverly       5489/001      2018-07     2019-07
                       Frequency
                       Standard
2.3    1515 / 93459    Broadband        Weinschel           LN673
                       Power Divider    Associates
                       SMA (Aux)
2.4    FSV30           Signal           Rohde & Schwarz     103005        2018-04     2020-04
                       Analyzer 10
                       Hz - 30 GHz
2.5    Fluke 177       Digital          Fluke Europe B.V.   86670383      2018-04     2020-04
                       Multimeter 03
                       (Multimeter)
2.6    VT 4002         Temperature      Vötsch              58566002150010 2018-04    2020-04
                       Chamber
2.7    A8455-4         4 Way Power                          -
                       Divider (SMA)
2.8    Opus10 THI      ThermoHygro      Lufft Mess- und   7482            2017-03     2019-03
       (8152.00)       Datalogger 03    Regeltechnik GmbH
                       (Environ)
2.9    SMBV100A        Vector Signal    Rohde & Schwarz     259291        2016-10     2019-10
                       Generator 9
                       kHz - 6 GHz
2.10 OSP120            Switching Unit   Rohde & Schwarz     101158        2018-05     2021-05
                       with
                       integrated
                       power meter

The calibration interval is the time interval between “Last Calibration” and “Calibration Due”.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                        Page 24 of 31


6     Antenna Factors, Cable Loss and Sample Calculations
This chapter contains the antenna factors with their corresponding path loss of the used
measurement path for all antennas as well as the insertion loss of the LISN.

6.1 LISN R&S ESH3-Z5 (150 kHz – 30 MHz)
                                                        cable
                                             LISN        loss
                                          insertion   (incl. 10
                                             loss         dB
                                            ESH3-      atten-
 Frequency                 Corr.              Z5       uator)
    MHz                     dB                dB          dB
      0,15                   10,1               0,1        10,0
         5                   10,3               0,1        10,2
         7                   10,5               0,2        10,3
        10                   10,5               0,2        10,3
        12                   10,7               0,3        10,4
        14                   10,7               0,3        10,4
        16                   10,8               0,4        10,4
        18                   10,9               0,4        10,5
        20                   10,9               0,4        10,5
        22                   11,1               0,5        10,6
        24                   11,1               0,5        10,6
        26                   11,2               0,5        10,7
        28                   11,2               0,5        10,7
        30                   11,3               0,5        10,8

Sample calculation

 ULISN (dB µV) = U (dB µV) + Corr. (dB)
 U = Receiver reading
 LISN Insertion loss = Voltage Division Factor of LISN
 Corr. = sum of single correction factors of used LISN, cables, switch units (if used)
 Linear interpolation will be used for frequencies in between the values in the table.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                          Page 25 of 31


6.2 Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)
                                              cable        cable       cable       cable      distance     dLimit      dused
                                             loss 1       loss 2      loss 3       loss 4       corr.     (meas.      (meas.
                 AF                         (inside      (outside    (switch         (to      (-40 dB/   distance    distance
 Frequency    HFH-Z2)       Corr.          chamber)     chamber)       unit)     receiver)    decade)     (limit)     (used)
    MHz       dB (1/m)       dB                dB           dB          dB           dB          dB          m          m
     0,009      20,50        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,01      20,45        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,015      20,37        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,02      20,36        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,025      20,38        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,03      20,32        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,05      20,35        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,08      20,30        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,1      20,20        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,2      20,17        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,3      20,14        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,49      20,12        -79,6                0,1          0,1         0,1          0,1        -80        300            3
  0,490001      20,12        -39,6                0,1          0,1         0,1          0,1        -40          30           3
       0,5      20,11        -39,6                0,1          0,1         0,1          0,1        -40          30           3
       0,8      20,10        -39,6                0,1          0,1         0,1          0,1        -40          30           3
         1      20,09        -39,6                0,1          0,1         0,1          0,1        -40          30           3
         2      20,08        -39,6                0,1          0,1         0,1          0,1        -40          30           3
         3      20,06        -39,6                0,1          0,1         0,1          0,1        -40          30           3
         4      20,05        -39,5                0,2          0,1         0,1          0,1        -40          30           3
         5      20,05        -39,5                0,2          0,1         0,1          0,1        -40          30           3
         6      20,02        -39,5                0,2          0,1         0,1          0,1        -40          30           3
         8      19,95        -39,5                0,2          0,1         0,1          0,1        -40          30           3
        10      19,83        -39,4                0,2          0,1         0,2          0,1        -40          30           3
        12      19,71        -39,4                0,2          0,1         0,2          0,1        -40          30           3
        14      19,54        -39,4                0,2          0,1         0,2          0,1        -40          30           3
        16      19,53        -39,3                0,3          0,1         0,2          0,1        -40          30           3
        18      19,50        -39,3                0,3          0,1         0,2          0,1        -40          30           3
        20      19,57        -39,3                0,3          0,1         0,2          0,1        -40          30           3
        22      19,61        -39,3                0,3          0,1         0,2          0,1        -40          30           3
        24      19,61        -39,3                0,3          0,1         0,2          0,1        -40          30           3
        26      19,54        -39,3                0,3          0,1         0,2          0,1        -40          30           3
        28      19,46        -39,2                0,3          0,1         0,3          0,1        -40          30           3
        30      19,73        -39,1                0,4          0,1         0,3          0,1        -40          30           3

Sample calculation

 E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
 U = Receiver reading
 AF = Antenna factor
 Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
 distance correction = -40 * LOG (dLimit/ dused)
 Linear interpolation will be used for frequencies in between the values in the table.
 Table shows an extract of values




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                             Page 26 of 31


6.3 Antenna R&S HL562 (30 MHz – 1 GHz)
(dLimit = 3 m)
                                              cable        cable       cable      cable      distance     dLimit       dused
                    AF                       loss 1       loss 2      loss 3      loss 4       corr.     (meas.       (meas.
                   R&S                      (inside      (outside    (switch        (to      (-20 dB/   distance     distance
 Frequency        HL562     Corr.          chamber)     chamber)       unit)    receiver)    decade)     (limit)      (used)
    MHz          dB (1/m)    dB                dB           dB          dB          dB          dB          m           m
        30           18,6      0,6               0,29         0,04       0,23         0,02        0,0            3           3
        50            6,0      0,9               0,39         0,09       0,32         0,08        0,0            3           3
       100            9,7      1,2               0,56         0,14       0,47         0,08        0,0            3           3
       150            7,9      1,6               0,73         0,20       0,59         0,12        0,0            3           3
       200            7,6      1,9               0,84         0,21       0,70         0,11        0,0            3           3
       250            9,5      2,1               0,98         0,24       0,80         0,13        0,0            3           3
       300           11,0      2,3               1,04         0,26       0,89         0,15        0,0            3           3
       350           12,4      2,6               1,18         0,31       0,96         0,13        0,0            3           3
       400           13,6      2,9               1,28         0,35       1,03         0,19        0,0            3           3
       450           14,7      3,1               1,39         0,38       1,11         0,22        0,0            3           3
       500           15,6      3,2               1,44         0,39       1,20         0,19        0,0            3           3
       550           16,3      3,5               1,55         0,46       1,24         0,23        0,0            3           3
       600           17,2      3,5               1,59         0,43       1,29         0,23        0,0            3           3
       650           18,1      3,6               1,67         0,34       1,35         0,22        0,0            3           3
       700           18,5      3,6               1,67         0,42       1,41         0,15        0,0            3           3
       750           19,1      4,1               1,87         0,54       1,46         0,25        0,0            3           3
       800           19,6      4,1               1,90         0,46       1,51         0,25        0,0            3           3
       850           20,1      4,4               1,99         0,60       1,56         0,27        0,0            3           3
       900           20,8      4,7               2,14         0,60       1,63         0,29        0,0            3           3
       950           21,1      4,8               2,22         0,60       1,66         0,33        0,0            3           3
      1000           21,6      4,9               2,23         0,61       1,71         0,30        0,0            3           3

(dLimit = 10 m)
          30        18,6       -9,9             0,29         0,04        0,23        0,02       -10,5          10           3
          50         6,0       -9,6             0,39         0,09        0,32        0,08       -10,5          10           3
         100         9,7       -9,2             0,56         0,14        0,47        0,08       -10,5          10           3
         150         7,9       -8,8             0,73         0,20        0,59        0,12       -10,5          10           3
         200         7,6       -8,6             0,84         0,21        0,70        0,11       -10,5          10           3
         250         9,5       -8,3             0,98         0,24        0,80        0,13       -10,5          10           3
         300        11,0       -8,1             1,04         0,26        0,89        0,15       -10,5          10           3
         350        12,4       -7,9             1,18         0,31        0,96        0,13       -10,5          10           3
         400        13,6       -7,6             1,28         0,35        1,03        0,19       -10,5          10           3
         450        14,7       -7,4             1,39         0,38        1,11        0,22       -10,5          10           3
         500        15,6       -7,2             1,44         0,39        1,20        0,19       -10,5          10           3
         550        16,3       -7,0             1,55         0,46        1,24        0,23       -10,5          10           3
         600        17,2       -6,9             1,59         0,43        1,29        0,23       -10,5          10           3
         650        18,1       -6,9             1,67         0,34        1,35        0,22       -10,5          10           3
         700        18,5       -6,8             1,67         0,42        1,41        0,15       -10,5          10           3
         750        19,1       -6,3             1,87         0,54        1,46        0,25       -10,5          10           3
         800        19,6       -6,3             1,90         0,46        1,51        0,25       -10,5          10           3
         850        20,1       -6,0             1,99         0,60        1,56        0,27       -10,5          10           3
         900        20,8       -5,8             2,14         0,60        1,63        0,29       -10,5          10           3
         950        21,1       -5,6             2,22         0,60        1,66        0,33       -10,5          10           3
        1000        21,6       -5,6             2,23         0,61        1,71        0,30       -10,5          10           3

Sample calculation
 E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
 U = Receiver reading
 AF = Antenna factor
 Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
 distance correction = -20 * LOG (dLimit/ dused)
 Linear interpolation will be used for frequencies in between the values in the table.
 Tables show an extract of values.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                            Page 27 of 31


6.4 Antenna R&S HF907 (1 GHz – 18 GHz)
                                                                        cable
                                              cable                    loss 3
                                             loss 1                   (switch
                                            (relay +       cable        unit,
                 AF                           cable       loss 2      atten-        cable
                R&S                          inside      (outside     uator &     loss 4 (to
 Frequency     HF907        Corr.          chamber)     chamber)     pre-amp)     receiver)
    MHz       dB (1/m)       dB                dB           dB            dB          dB
      1000        24,4       -19,4               0,99         0,31       -21,51        0,79
      2000        28,5       -17,4               1,44         0,44       -20,63        1,38
      3000        31,0       -16,1               1,87         0,53       -19,85        1,33
      4000        33,1       -14,7               2,41         0,67       -19,13        1,31
      5000        34,4       -13,7               2,78         0,86       -18,71        1,40
      6000        34,7       -12,7               2,74         0,90       -17,83        1,47
      7000        35,6       -11,0               2,82         0,86       -16,19        1,46

                                                                                     cable
                                                                                    loss 4
                                              cable                                (switch
                                             loss 1        cable        cable        unit,                  used
                 AF                          (relay       loss 2       loss 3      atten-        cable      for
                R&S                          inside      (inside      (outside     uator &     loss 5 (to   FCC
 Frequency     HF907        Corr.          chamber)     chamber)     chamber)     pre-amp)     receiver)    15.247
    MHz       dB (1/m)       dB                dB           dB           dB            dB          dB
      3000        31,0       -23,4               0,47         1,87         0,53       -27,58        1,33
      4000        33,1       -23,3               0,56         2,41         0,67       -28,23        1,31
      5000        34,4       -21,7               0,61         2,78         0,86       -27,35        1,40
      6000        34,7       -21,2               0,58         2,74         0,90       -26,89        1,47
      7000        35,6       -19,8               0,66         2,82         0,86       -25,58        1,46

                                              cable
                                             loss 1        cable        cable        cable        cable       cable
                 AF                          (relay       loss 2       loss 3       loss 4       loss 5       loss 6
                R&S                          inside       (High         (pre-      (inside      (outside        (to
 Frequency     HF907        Corr.          chamber)       Pass)        amp)       chamber)     chamber)     receiver)
    MHz       dB (1/m)       dB                dB           dB            dB          dB           dB           dB
      7000        35,6       -57,3               0,56         1,28       -62,72         2,66         0,94         1,46
      8000        36,3       -56,3               0,69         0,71       -61,49         2,84         1,00         1,53
      9000        37,1       -55,3               0,68         0,65       -60,80         3,06         1,09         1,60
     10000        37,5       -56,2               0,70         0,54       -61,91         3,28         1,20         1,67
     11000        37,5       -55,3               0,80         0,61       -61,40         3,43         1,27         1,70
     12000        37,6       -53,7               0,84         0,42       -59,70         3,53         1,26         1,73
     13000        38,2       -53,5               0,83         0,44       -59,81         3,75         1,32         1,83
     14000        39,9       -56,3               0,91         0,53       -63,03         3,91         1,40         1,77
     15000        40,9       -54,1               0,98         0,54       -61,05         4,02         1,44         1,83
     16000        41,3       -54,1               1,23         0,49       -61,51         4,17         1,51         1,85
     17000        42,8       -54,4               1,36         0,76       -62,36         4,34         1,53         2,00
     18000        44,2       -54,7               1,70         0,53       -62,88         4,41         1,55         1,91

Sample calculation

 E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
 U = Receiver reading
 AF = Antenna factor
 Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
 Linear interpolation will be used for frequencies in between the values in the table.
 Tables show an extract of values.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                              Page 28 of 31


6.5 Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)
                                              cable       cable       cable        cable      cable
                 AF                          loss 1      loss 2      loss 3       loss 4      loss 5
               EMCO                         (inside       (pre-     (inside      (switch        (to
 Frequency    3160-09       Corr.          chamber)      amp)      chamber)        unit)    receiver)
    MHz       dB (1/m)       dB                dB          dB          dB           dB          dB
     18000        40,2       -23,5               0,72     -35,85         6,20        2,81         2,65
     18500        40,2       -23,2               0,69     -35,71         6,46        2,76         2,59
     19000        40,2       -22,0               0,76     -35,44         6,69        3,15         2,79
     19500        40,3       -21,3               0,74     -35,07         7,04        3,11         2,91
     20000        40,3       -20,3               0,72     -34,49         7,30        3,07         3,05
     20500        40,3       -19,9               0,78     -34,46         7,48        3,12         3,15
     21000        40,3       -19,1               0,87     -34,07         7,61        3,20         3,33
     21500        40,3       -19,1               0,90     -33,96         7,47        3,28         3,19
     22000        40,3       -18,7               0,89     -33,57         7,34        3,35         3,28
     22500        40,4       -19,0               0,87     -33,66         7,06        3,75         2,94
     23000        40,4       -19,5               0,88     -33,75         6,92        3,77         2,70
     23500        40,4       -19,3               0,90     -33,35         6,99        3,52         2,66
     24000        40,4       -19,8               0,88     -33,99         6,88        3,88         2,58
     24500        40,4       -19,5               0,91     -33,89         7,01        3,93         2,51
     25000        40,4       -19,3               0,88     -33,00         6,72        3,96         2,14
     25500        40,5       -20,4               0,89     -34,07         6,90        3,66         2,22
     26000        40,5       -21,3               0,86     -35,11         7,02        3,69         2,28
     26500        40,5       -21,1               0,90     -35,20         7,15        3,91         2,36

Sample calculation

 E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
 U = Receiver reading
 AF = Antenna factor
 Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
 Linear interpolation will be used for frequencies in between the values in the table.
 Table shows an extract of values.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                            Page 29 of 31


6.6 Antenna EMCO 3160-10 (26.5 GHz – 40 GHz)
                                              cable        cable       cable      cable     distance      dLimit       dused
                 AF                          loss 1       loss 2      loss 3      loss 4      corr.      (meas.       (meas.
               EMCO                         (inside      (outside    (switch        (to     (-20 dB/    distance     distance
 Frequency    3160-10       Corr.          chamber)     chamber)       unit)    receiver)   decade)      (limit)      (used)
    GHz       dB (1/m)       dB                dB           dB          dB          dB         dB           m           m
      26,5        43,4       -11,2                4,4                                            -9.5            3           1
      27,0        43,4       -11,2                4,4                                            -9.5            3           1
      28,0        43,4       -11,1                4,5                                            -9.5            3           1
      29,0        43,5       -11,0                4,6                                            -9.5            3           1
      30,0        43,5       -10,9                4,7                                            -9.5            3           1
      31,0        43,5       -10,8                4,7                                            -9.5            3           1
      32,0        43,5       -10,7                4,8                                            -9.5            3           1
      33,0        43,6       -10,7                4,9                                            -9.5            3           1
      34,0        43,6       -10,6                5,0                                            -9.5            3           1
      35,0        43,6       -10,5                5,1                                            -9.5            3           1
      36,0        43,6       -10,4                5,1                                            -9.5            3           1
      37,0        43,7       -10,3                5,2                                            -9.5            3           1
      38,0        43,7       -10,2                5,3                                            -9.5            3           1
      39,0        43,7       -10,2                5,4                                            -9.5            3           1
      40,0        43,8       -10,1                5,5                                            -9.5            3           1

Sample calculation

 E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
 U = Receiver reading
 AF = Antenna factor
 Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
 Linear interpolation will be used for frequencies in between the values in the table.
 distance correction = -20 * LOG (dLimit/ dused)
 Linear interpolation will be used for frequencies in between the values in the table.
 Table shows an extract of values.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                                            Page 30 of 31


7    Setup Drawings




Drawing 1: Setup in the Anechoic chamber:
           Measurements below 1 GHz: Semi-anechoic, conducting ground plane.
           Measurements above 1 GHz: Fully-anechoic, absorbers on all surfaces.




8    Measurement uncertainty

    Test Case                                     Parameter       Uncertainty
    Peak power output                             Fieldstrength   ± 5.5 dB
    Occupied bandwidth                            Power           ± 2.9 dB
                                                  Frequency:      ± 0.125 kHz
    Spurious radiated emissions                   Fieldstrength   ± 5.5 dB
                                                  Frequency:      ± 11.2 kHz
    AC Power Line                                 Power           ± 3.4 dB




9    Photo Report

Photos are included in an external report.




Test report reference: MDE_LAIRD_1812_FCCa_rev1                                 Page 31 of 31



Document Created: 2019-04-26 12:10:55
Document Modified: 2019-04-26 12:10:55

© 2024 FCC.report