MPE

FCC ID: RIW-ZWA-G220

RF Exposure Info

Download: PDF
FCCID_825547

                                               Report No.: FR761102




            Appendix C. Maximum Permissible Exposure




FCC ID: RIW-ZWA-G220                          Page No.   : 1 of 3


                                                                                                 Report No.: FR761102



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures that the
      public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In
      accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile
      device whereby a distance of 0.2 m normally can be maintained between the user and the device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                                     Averaging Time
        Frequency Range             Electric Field       Magnetic Field      Power Density (S)
                                                                                                      |E|²,|H|² or S
              (MHz)              Strength (E) (V/m)     Strength (H) (A/m)      (mW/ cm²)
                                                                                                        (minutes)
              0.3-3.0                   614                   1.63                    (100)*                6
              3.0-30                  1842 / f               4.89 / f             (900 / f)*                6
              30-300                   61.4                   0.163                    1.0                  6
            300-1500                                                                  F/300                 6
          1500-100,000                                                                  5                   6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                                     Averaging Time
        Frequency Range             Electric Field      Magnetic Field       Power Density (S)
                                                                                                      |E|²,|H|² or S
              (MHz)              Strength (E) (V/m)    Strength (H) (A/m)       (mW/ cm²)
                                                                                                        (minutes)
             0.3-1.34                  614                    1.63                 (100)*                  30
             1.34-30                   824/f                 2.19/f               (180/f)*                 30
              30-300                   27.5                  0.073                     0.2                 30
            300-1500                                                              F/1500                   30
          1500-100,000                                                                 1.0                 30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

      E (V/m) =
                   30 × P × G                    Power Density:   Pd (W/m²) =
                                                                                E2
                       d                                                        377
      E = Electric field (V/m)
      P = Peak RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to

      Pd =
              30 × P × G
               377 × d 2
      From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain
      of the used antenna, the RF power density can be obtained.



FCC ID: RIW-ZWA-G220                                                                           Page No.   : 2 of 3


                                                                                     Report No.: FR761102


1.3. Calculated Result and Limit

      Antenna Type : Dipole
      Max Conducted Power for IEEE 802.11b/g : 26.65dBm
                                   Peak Output                  Power Density Limit of Power
      Antenna Gain Antenna Gain                  Peak Output
                                      Power                          (S)        Density (S)    Test Result
          (dBi)      (numeric)                   Power ( mW )
                                      (dBm)                       (mW/cm²)      (mW/cm²)
             3          1.9953       26.6500      462.3810        0.183633          1          Complies