58611RAN.002s

FCC ID: RI7WE866C3

RF Exposure Info

Download: PDF
FCCID_4301952

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                                                            Test report No:
                                                                                         NIE: 58611RAN.002


          Assessment report
          RF EXPOSURE REPORT ACCORDING TO
          FCC 47 CFR Part 2.1091
          ISED RSS-102 Issue 5:2015
          IEEE Std C95.3TM -2002 (R2008)
           Identification of item tested                     Companion module

           Trademark                                         Telit

           Model and /or type reference                      WE866C3-P

           Other identification of the product               FCC ID: RI7WE866C3
                                                             IC ID: 5131A–WE866C3
                                                             HW version: CS1929a-A
                                                             SW Version: Host SW V_25.20.000-B010
           Features                                          BT BR/EDR/LE 4.2 + Wifi a/b/g/n/ac (wave 1=> Max
                                                             BW= 80 MHz)

           Manufacturer                                      TELIT AUTOMOTIVE SOLUTIONS
                                                             Esplanade Anton Philips 14460 Colombelles, France

           Test method requested, standard                   IEEE Std C95.3TM -2002 (R2008). IEEE Recommended
                                                             Practice for Measurements and Computations of Radio
                                                             Frequency Electromagnetic Fields With Respect to
                                                             Human Exposure to Such Fields, 100 kHz–300 GHz
                                                             FCC 47 CFR Part 2.1091 Radiofrequency radiation
                                                             exposure evaluation: mobile devices.
                                                             ISED RSS-102 Issue 5 (2015-03) – Radio Frequency
                                                             Exposure      Compliance     of   Radiocommunication
                                                             Apparatus (All Frequency Bands)

           Summary                                           IN COMPLIANCE

           Approved by (name / position & signature)         Miguel Lacave                        MIGUEL LACAVE
                                                             Antennas Lab Manager                 GARCÍA
                                                                                                  2019.05.03
                                                                                                  12:00:04 +02'00'

           Date of issue                                     2019-05-03

           Report template No                                FAN36_00




Report No: (NIE) 58611RAN.002                                                                                    2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    Index
    Competences and guarantees .................................................................................................... 3
    General conditions ...................................................................................................................... 3
    Data provided by the client.......................................................................................................... 3
    Identification of the client............................................................................................................. 3
    Document history ........................................................................................................................ 3
    General description of the device under evaluation ..................................................................... 4
    Assessment summary................................................................................................................. 5
    Appendix A: FCC RF Exposure................................................................................................... 6
         FCC RF Exposure evaluation for mobile devices.................................................................... 7
         FCC MPE Evaluation Results ................................................................................................. 8
    Appendix B: ISED RF Exposure................................................................................................ 10
         ISED RF Exposure evaluation for mobile devices................................................................. 11
         ISED MPE Evaluation Results .............................................................................................. 12




 Report No: (NIE) 58611RAN.002                                      Page 2 of 13                                                          2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




Competences and guarantees
    In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and
    maintenance program for its measurement equipment.
    DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements
    and the tests performed to the item under test on the date and under the conditions stated on the report and, it
    is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test.
    DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under
    test and the results of the test.
    The results presented in this Assessment Report apply only to the particular item under test established in this
    document.
    IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
    except in full, without the previous written permission of DEKRA.


General conditions
         1. This report is only referred to the item that has undergone the assessment.
         2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
            or competent Authorities.
         3. This document is only valid if complete; no partial reproduction can be made without previous written
            permission of DEKRA.
         4. This assessment report cannot be used partially or in full for publicity and/or promotional purposes
            without previous written permission of DEKRA and the Accreditation Bodies.


Data provided by the client
    The device under evaluation consist of a companion module, supporting Wi-Fi 802.11 a/b/g/n/ac (wave 1) and
    BT (BR/EDR/LE(4.2)). It supports single RF antenna port for both technologies Wifi and BT. SDIO and HCI I/F,
    respectively for Wi-Fi and BT control. Module is controlled via a host Telit module, LE920A4 or LE910C1
    DEKRA declines any responsibility with respect to the information provided by the client and that may affect the
    validity of results.


Identification of the client
    TELIT AUTOMOTIVE SOLUTIONS
    Esplanade Anton Philips 14460 Colombelles, France


Document history
   Report number                     Date                                            Description
    58611RAN.002                 2019-05-03           First release




 Report No: (NIE) 58611RAN.002                                        Page 3 of 13                            2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




General description of the device under evaluation
   The device under evaluation consist of a companion module, supporting Wi-Fi 802.11 a/b/g/n/ac (wave 1) and
   BT (BR/EDR/LE(4.2)). It supports single RF antenna port for both technologies Wifi and BT. SDIO and HCI
   I/F, respectively for Wi-Fi and BT control. Module is controlled via a host Telit module, LE920A4 or LE910C1.

   According to the manufacturer, during its normal use, the separation distance between the device and the body
   of nearby users will be greater than 20 cm. In order to perform the assessment a conservative separation
   distance of 20 cm has been used.
   The equipment specifications declared by the manufacturer for each supported technology and band are:

                                                                             Maximum RF
                                                                                              Max.     Maximum
                          Band                                               output power
                                              Technology*              Band                  Antenna    E.I.R.P.
                          (MHz)                                             (incl. tune-up)
                                                                                            gain (dBi)  (dBm)
                                                                                 (dBm)
                       2412-2480   Wi-Fi 802.11b/g/n ISM                              18.0       +2.5    20.5
                       5170-5725 Wi-Fi 802.11a/n/ac  U-NII                            16.5       +4.5    21.0
                       2402-2480 Bluetooth BR/RDR/LE ISM                               3.9       +2.5     6.4
                                                             Table 1: Equipment specifications

   *Note: Only the maximum output power mode has been taken into account as a worst case mode for
   technologies with different transmission modes that use the same module and antenna at the same
   transmission frequency range.




 Report No: (NIE) 58611RAN.002                                         Page 4 of 13                                2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Assessment summary

                                                 Radiofrequency radiation exposure limits

                                       FCC 47 CFR § 2.1091 & ISED RSS-102 Issue 5 (2015-03)

                                           Band                                              VERDICT
                 Assessment                                    Technology            Band
                                           (MHz)                                            (Pass/Fail)
                          1                 2450                   Wi-Fi          ISM          Pass
                          2                 5000                   Wi-Fi         U-NII         Pass
                          3                 2450                Bluetooth         ISM          Pass
                                                             Table 2: Assessment summary




 Report No: (NIE) 58611RAN.002                                        Page 5 of 13                        2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




      Appendix A: FCC RF Exposure




 Report No: (NIE) 58611RAN.002                               Page 6 of 13   2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




FCC RF Exposure evaluation for mobile devices
   Devices operating in standalone mobile device exposure conditions may contain a single transmitter or multiple
   transmitters that do not transmit simultaneously. A minimum test separation distance ≥ 20 cm is required
   between the antenna and radiating structures of the device and nearby persons to apply mobile device
   exposure limits. The distance must be at least 20 cm and fully supported by the operating and installation
   configurations of the transmitter and its antenna(s), according to the source-based time-averaged maximum
   power requirements of § 2.1091(d)(2). In cases where cable losses or other attenuations are applied to
   determine compliance, the most conservative operating configurations and exposure conditions must be
   evaluated. The minimum test separation distance required for a device to comply with mobile device exposure
   conditions must be clearly identified in the installation and operating instructions, for all installation and
   exposure conditions, to enable users and installers to comply with RF exposure requirements. For mobile
   devices that have the potential to operate in portable device exposure conditions, similar to the configurations
   described in § 2.1091(d)(4), a KDB inquiry is required to determine the SAR test requirements for
   demonstrating compliance.
   When a device qualifies for the categorical exclusion provision of § 2.1091(c), the minimum test separation
   distance may be estimated, when applicable, by simple calculations according to plane-wave equivalent
   conditions, to ensure the transmitter and its antenna(s) can operate in manners that meet or exceed the
   estimated distance. The source-based time-averaged maximum radiated power, according to the maximum
   antenna gain, must be applied to calculate the field strength and power density required to establish the
   minimum test separation distance. When the estimated test separation distance becomes overly conservative
   and does not support compliance, MPE measurement or computational modeling may be used to determine the
   required minimum separation distance.
   According to §1.1310 Radiofrequency radiation exposure limits, paragraph (e), the limits for Maximum
   Permissible Exposure (MPE) to radiofrequency electromagnetic fields are:




 Report No: (NIE) 58611RAN.002                               Page 7 of 13                                 2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




FCC MPE Evaluation Results
   Each supported transmission technology will be evaluated to determine if it is in compliance with limits for
   Maximum Permissible Exposure (MPE) to radiofrequency electromagnetic fields.

   In order to perform the assessment, the following equations have been used for the calculations; these
   equations are accurate in the far-field of an antenna and will over-predict power density in the near field, where
   they could be used for making a "worst case" or conservative prediction:

                                               PE .I .R.P. [mW ]
   Power density: S[mW / cm 2 ] 
                                                4R[cm]2


                                                                    PE .I .R.P. [mW ]
   Minimum compliance distance: R min [cm] 
                                                                   4S[mW / cm 2 ]

   Where:
    S = power density
    PE . I . R.P. = Equivalent isotropically radiated power
    R = distance to the center of radiation of the antenna (evaluation distance)
    Rmin = distance to the center of radiation of the antenna




 Report No: (NIE) 58611RAN.002                                          Page 8 of 13                        2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


   Assessment 1 – Wi-Fi 2.45 GHz Band

     Maximum output power (dBm):                                             18.0
     Maximum antenna Gain (dBi):                                              2.5
     Minimum use distance (cm):                                              20.0
     Worst Case Frequency (MHz):                                            2412.0
     Maximum EIRP (dBm):                                                     20.5
     Maximum EIRP (mW):                                                     112.2
     General population - Power density limit (mW/cm 2):                      1.0

   Power density at minimum use distance:
    Power density (mW/cm 2):                                                 0.22
    General population - Power density limit (mW/cm 2):                       1.0
    Verdict for general population:                                         PASS

   The power density level for this transmission mode is below general population exposure power density limit.


   Assessment 2 – Wi-Fi 5 GHz Band

     Maximum output power (dBm):                                             16.5
     Maximum antenna Gain (dBi):                                              4.5
     Minimum use distance (cm):                                              20.0
     Worst Case Frequency (MHz):                                            5170.0
     Maximum EIRP (dBm):                                                     21.0
     Maximum EIRP (mW):                                                     125.89
     General population - Power density limit (mW/cm 2):                      1.0

   Power density at minimum use distance:
    Power density (mW/cm 2):                                                0.025
    General population - Power density limit (mW/cm 2):                      1.0
    Verdict for general population:                                         PASS

   The power density level for this transmission mode is below general population exposure power density limit.


   Assessment 3 – Bluetooth 2.45 GHz Band

     Maximum output power (dBm):                                              3.9
     Maximum antenna Gain (dBi):                                              2.5
     Minimum use distance (cm):                                              20.0
     Worst Case Frequency (MHz):                                            2402.0
     Maximum EIRP (dBm):                                                      6.4
     Maximum EIRP (mW):                                                      4.37
     General population - Power density limit (mW/cm 2):                      1.0

   Power density at minimum use distance:
    Power density (mW/cm 2):                                                0.00087
    General population - Power density limit (mW/cm 2):                        1.0
    Verdict for general population:                                          PASS

   The power density level for this transmission mode is below general population exposure power density limit.
 Report No: (NIE) 58611RAN.002                               Page 9 of 13                                 2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




      Appendix B: ISED RF Exposure




 Report No: (NIE) 58611RAN.002                               Page 10 of 13   2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




ISED RF Exposure evaluation for mobile devices
   According to RSS-102 Issue 5, Paragraph “4. Exposure Limits”, Industry of Canada has adopted the RF field
   strength limits established in Health Canada’s RF exposure guideline, Safety code 6:




 Report No: (NIE) 58611RAN.002                               Page 11 of 13                             2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




ISED MPE Evaluation Results
   Each supported transmission technology will be evaluated to determine if it is in compliance with RSS-102
   Issue 5, RF Field Strength Limits for devices used by the General Public.

   In order to perform the assessment, the following equations have been used for the calculations; these
   equations are accurate in the far-field of an antenna and will over-predict power density in the near field, where
   they could be used for making a "worst case" or conservative prediction:



                                          PE .I .R. P.[W ]
   Power density: S [W / m 2 ] 
                                          4R[m]2
                                                              PE . I . R. P. [W ]
   Minimum compliance distance: Rmin [ m] 
                                                             4 S [W / m 2 ]

   Where:
    S = power density
    PE . I . R.P. = Equivalent isotropically radiated power
    R = distance to the center of radiation of the antenna (evaluation distance)
    Rmin = distance to the center of radiation of the antenna




 Report No: (NIE) 58611RAN.002                                       Page 12 of 13                          2019-05-03


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


   Assessment 1 – Wi-Fi 2.45 GHz Band

     Maximum output power (dBm):                                              18.0
     Maximum antenna gain (dBi):                                               2.5
     Minimum use distance (m):                                                 0.2
     Worst Case Frequency (MHz):                                             2412.0
     Maximum EIRP (dBm):                                                      20.5
     Maximum EIRP (W):                                                        0.11
     General public - Power density limit (W/m 2):                           5.366

   Power density at minimum use distance:
    Power density (W/m 2):                                                   0.223
    General public - Power density limit (W/m 2):                            5.366
    Verdict for general public:                                              PASS

   The power density level for this transmission mode is below general public power density limit.


   Assessment 2 – Wi-Fi 5 GHz Band

     Maximum output power (dBm):                                              16.5
     Maximum antenna gain (dBi):                                               4.5
     Minimum use distance (m):                                                 0.2
     Worst Case Frequency (MHz):                                             5170.0
     Maximum EIRP (dBm):                                                      21.0
     Maximum EIRP (W):                                                        0.13
     General public - Power density limit (W/m 2):                           9.035

   Power density at minimum use distance:
    Power density (W/m 2):                                                   0.250
    General public - Power density limit (W/m 2):                            9.035
    Verdict for general public:                                              PASS

   The power density level for this transmission mode is below general public power density limit.


   Assessment 3 – Bluetooth 2.45 GHz Band

     Maximum output power (dBm):                                               3.9
     Maximum antenna gain (dBi):                                               2.5
     Minimum use distance (m):                                                 0.2
     Worst Case Frequency (MHz):                                             2402.0
     Maximum EIRP (dBm):                                                       6.4
     Maximum EIRP (W):                                                       0.004
     General public - Power density limit (W/m 2):                            5.35

   Power density at minimum use distance:
    Power density (W/m 2):                                                   0.009
    General public - Power density limit (W/m 2):                             5.35
    Verdict for general public:                                              PASS

   The power density level for this transmission mode is below general public power density limit.
 Report No: (NIE) 58611RAN.002                               Page 13 of 13                           2019-05-03



Document Created: 2019-05-03 12:00:04
Document Modified: 2019-05-03 12:00:04

© 2024 FCC.report