                                              TEST REPORT
                                              No.: 6-0608-14-1-4b



                                                            According to:
                                                      FCC Regulations
                                                            Part 2.1091

                                                       IC-Regulations
                                                         RSS-102, Issue 5


                                                               for

                                      Telit Communications S.p.A.

                                                     3G module
                                                     UE866-N3G

                                            FCC-ID: RI7UE866N3
                                             IC: 5131A-UE866N3
                                                  PMN: UE866-N3G
                                                    HVIN: 0H0

                                           Laboratory Accreditation and Listings




                                                                                                   Voluntary Controls for
                                                                             Industry Canada    Electromagnetic Emissions
                                                                            Reg. No.: 3462D-1           Reg. No.:
                                                     Reg. No.: 736496       Reg. No.: 3462D-2
                                                     MRA US-EU 0003                                  R-2666 C-2914,
                                                                            Reg. No.: 3462D-3        T-1967, G-301




                                     accredited according to DIN EN ISO/IEC 17025


                                                     CETECOM GmbH
                              Laboratory Radio Communications & Electromagnetic Compatibility
                                          Im Teelbruch 116 • 45219 Essen • Germany
                                 Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                               Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                   E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                    Page 1 of 22
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without
the written approval of the testing laboratory                                  © Copyright: All rights reserved by CETECOM


Test Report 6-0608-14-1-4b, Page 2 of 22



Table of contents
1. SUMMARY OF TEST RESULTS...................................................................................................................... 3
  1.1. TX mode, tests overview FCC Part 2.1091 ..................................................................................................... 3
2. ADMINISTRATIVE DATA ............................................................................................................................... 4
  2.1. Identification of the testing laboratory ............................................................................................................. 4
  2.2. Test location .................................................................................................................................................... 4
  2.3. Organizational items ........................................................................................................................................ 4
  2.4. Applicant’s details ........................................................................................................................................... 4
  2.5. Manufacturer’s details ..................................................................................................................................... 4
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................. 5
  3.1. TECHNICAL DESCRIPTION OF MAIN EUT ............................................................................................. 5
  3.2. EUT: Type, S/N etc. and short descriptions used in this test report ................................................................ 6
  3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions .................................................................. 6
  3.4. EUT set-ups ..................................................................................................................................................... 6
  3.5. EUT operating modes .................................................................................................................................... 7
  3.6. Configuration of cables used for testing .......................................................................................................... 7
4. MEASUREMENTS ............................................................................................................................................. 8
  4.1. Radio Frequency Exposure Evaluation §2.1091 .............................................................................................. 8
  4.2. Results for fixed and mobile operations .......................................................................................................... 10
  4.3. Conclusion for maximum admissible antenna gain (FCC only) ...................................................................... 14
  4.4. Canada RSS-102, Issue 5 regulations .............................................................................................................. 15
  4.5. Measurement uncertainties .............................................................................................................................. 16
5. ABBREVIATIONS USED IN THIS REPORT ................................................................................................. 16
6. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ......................... 17
7. INSTRUMENTS AND ANCILLARY ................................................................................................................ 18
  7.1. Used equipment “CTC” ................................................................................................................................... 18
8. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ............................................................................. 22



Table of annex                                                                                                                                        Total pages


Annex 1: External EUT photographs – separate document TR6-0608-14-1-4a-A1                                                                                              5

The listed attachments are an integral part of this report.




TR6-0608-14-1-4b


                                                                                                                              Tm

Test Report 6—0608—14—1—4b, Page 3 of22                                                                ctrtcom


1. Summary of test results

The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does
not assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.




1.1. TX mode, tests overview FCC Part 2.1091
  No. of                                                    References & Limits                           EUT
  4                  Test                                                                        EUT
 Diagram                          Port              FCC                4              hok                 op—       Result
                    Cases                                      RSS Section      Test limits     set—up
   group                                       Standard                                                   mode
                                Antenna
              RF Power              ;           g                                                                   Passed
     ~         (conducted)      terminal        §2.1046             T               WA             2       142     Remark 1
                                (conducted)
                                                §2.1046       RSS—132: 5.4
     L        RFPower           Capimg,       §22.913@0@) SRSP—503: 5.13        |_=" WAtERP        ;      ;;,       Passed
                   (radiated)                  <              RSS—133:4.1/6.4                                      Remark 1
                                               §24.232(c)    LSRSP.S10:5.1.2    <2Watt (EIRP)
                Radio                                                                                                   ,
              frequency                         §                                   : &
     ——        Exposure         Cabinet         §e          RSS—102, Issue 5    Feg: §11310        3      1+2       Passed
                     ;                          §2.1091                            Table 1
              Evaluation
                   (MPE)
Remark: 1.) See separate test report TR6—0608—14—1—4a

This report does not take into consideration a possible collocation with other transmitters (ex. BT, Wi—Fi, etc.).
Lower antenna gain will be the result.




Dipl.—Ing. Rachid   Acharkaoui                                                            Dipl.Ing. Christian Lorenz
Responsible for test section                                                              Responsible for test report




TR6—0608—14—1—4b


Test Report 6-0608-14-1-4b, Page 4 of 22




2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report:                                          Martin Nunier
Responsible project leader:                                           Dipl.-Ing. N. Perez
Receipt of EUT:                                                       2015-02-09
Date(s) of test:                                                      2015-02-09 – 2015-03-31
Date of report:                                                       2015-04-20
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.01
2.4. Applicant’s details

Applicant’s name:                                                     Telit Communications S.p.A.
Address:                                                              Via Stazione di Prosecco, 5/B
                                                                      34010 SGONICO (TS)

                                                                      Italy
Contact person:                                                       Mr. Fabrizio Druscovich

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 5 of 22




3. Equipment under test (EUT)

3.1. TECHNICAL DESCRIPTION OF MAIN EUT
W-CDMA :

TX-frequency range                    FDD Band 2: 1852.4–1907.6 MHz (Uplink), 1930-1990 MHz (Downlink)
                                      FDD Band 5: 826.4-846.6 MHz (Uplink), 869-894 MHz (Downlink)
Type of modulation                    FDD-Mode Release99: QPSK
                                      FDD Mode Release 5+6: 16QAM additional
Number of channels                    FDD Band 2: UARFCN range 9262 – 9400 – 9538
                                      FDD Band 5: UARFCN range 4132 – 4183 – 4233
UMTS-HSPA connectivity                 Uplink speed: 5.76 Mb/s (category 6)
                                       Uplink speed:

                            Band II Channel 9262/ 9400/ 9538
      Test Channels
                            Band V Channel 4132/ 4183/ 4233

Emission designator(s)                Band II: 4M17F9W
                                      Band V: 4M17F9W
                                       Value: 2.14 dBi according data sheet
Antenna Gain Tx (main)
                                       No information from customer
Power supply                           3.8 V
Special EMI components                --
EUT sample type                        Production                 Pre-Production    Engineering
MAX PEAK Output Power:
Conducted         FDD-Mode 2          22.54 dBm (AV)
                  FDD-Mode 5          22.37 dBm (AV)




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 6 of 22



3.2. EUT: Type, S/N etc. and short descriptions used in this test report

Short
                                                                     S/N              HW                 SW
descrip-              EUT                     Type
                                                                serial number    hardware status    software status
tion*)
                                                                   IMEI
EUT A              UE866-N3G               3G module           359335059003              0              12.00.806
                                                                    548
*) EUT short description is used to simplify the identification of the EUT in this test report.



3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

   AE
                                                                     S/N              HW              SW
  short     Auxiliary Equipment               Type
                                                                serial number    hardware status software status
descrip-
 tion *)
  AE 1         Bearer Board #1                  -               1634900047               -                  -

  AE 2         Bearer Board #2                  -              113920140091              -                  -

                   Ktec
  AE 3                               KSAS0151200125D5                 --                 --                --
               AC/DC charger

  AE 4             USB cable          Highspeed USB 2.0               --                 --                --

                                                                                   900-1800-
                                                                                  UMTS Cable
  AE 5              Antenna                T-AT314-BU                 --                                   --
                                                                                  RG 174mm.
                                                                                     2500
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.4. EUT set-ups

EUT set-up
                       Combination of EUT and AE                                     Remarks
  no.*)

                   EUT A + AE 1 + AE 2 + AE 3 + AE 4 +
   set. 1                                                                     Used for radiated tests
                              AE 5 + AE 5

   set. 2                   EUT A + AE 1 + AE 2                              Used for conducted tests

   set. 3                         EUT A                               Not tested: used for MPE calculation
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 7 of 22


3.5. EUT operating modes
3.5.1. EUT operating modes W-CDMA

EUT          Description of     Additional information:
operating    operating modes:
mode
no.*)
                              A communication link is established between the mobile station (UE) and the test
                              simulator. The transmitter is operated on its maximum rated output
          FDD-Band 2          power class: 24dBm nominal.
   op. 1                      The input signal to the receiver is modulated with normal test modulation.
          12.2 kbps RMC       The wanted RF input signal level to the receiver of the mobile station is set to a
                              level to provide a stable communication link according Table E5.1/Table E5.1A as
                              described in 3GPP TS34.121, Annex E.
                              A communication link is established between the mobile station (UE) and the test
                              simulator. The transmitter is operated on its maximum rated output
          FDD-Band 5          power class: 24dBm nominal.
   op. 2                      The input signal to the receiver is modulated with normal test modulation.
          12.2 kbps RMC       The wanted RF input signal level to the receiver of the mobile station is set to a
                              level to provide a stable communication link according Table E5.1/Table E5.1A as
                              described in 3GPP TS34.121, Annex E.
*) EUT operating mode no. is used to simplify the test report.


3.6. Configuration of cables used for testing
 Cable
                                                                 S/N             HW            Cable length
number              Item                    Type
                                                            serial number   hardware status
Cable 1              --                      --                  --                --               --
Remark: no cable used




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 8 of 22




4. Measurements

 4.1. Radio Frequency Exposure Evaluation §2.1091
4.1.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location    CETECOM Essen (Chapter. 2.2.1)          Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
                For Evaluation instruments are not needed. Results are determined by calculation.



4.1.2. Requirements
                            The criteria used for the evaluation of human exposure to radio frequency radiation is table 1 according FCC
                            §1.1310 and table chapter 4.2 of RSS-102 standard and it is subject for evaluation of the RF exposure prior to
     FCC: §1.1310           equipment authorization.
                            As the mobile equipment is authorized under Part 22 (Subpart H) and Part 24 of the FCC Rules, it is subject
                            for evaluation of the RF exposure prior to equipment authorization.
                            Further information on evaluating compliance with these limits can be found in the FCC’s OST/OET Bulletin
                            Number 65, ‘‘Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radiofrequency
                            Radiation.’’
                            For purposes of these requirements mobile devices are defined by the FCC as transmitters designed to be used
     FCC § 2.1091           in other than fixed locations and to generally be used in such a way that a separation distance of at least 20
                            centimeters is normally maintained between radiating structures and the body of the user or nearby persons.
                            These devices are normally evaluated for exposure potential with relation to the MPE limits given in Table 1
                            of Appendix A.




 Table 1: LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
     Frequency range         Electric field strength       Magnetic field strength           Power density             Averaging time
          [MHz)                      [V/m]                         [A/m]                      [mW/cm²]                   [minutes]
         30 - 300                     61.4                         0.163                          1.0                        6
        300 - 1500                      -                                                        f/300                       6
      1500 - 100,000                    -                                                          5                         6
                                         (B) Limits for General Population / Uncontrolled Exposure
        0.3 – 1.34                     614                          1.63                        *(100)                        30
         1.34 – 30                    824/f                        2.19/f                      *(180/f²)                      30
         30 - 300                     27.5                         0.073                          0.2                         30
        300 - 1500                      -                             -                         f/1500                        30
       1500 – 100,0                     -                             -                           1.0                         30

For given power density limit at a single frequency (accord. Table 1 Limits) the maximum antenna gain can be
calculated.

The used equation to predict the power density in the far-field of one single radiating antenna can be made by
following equation:

       EIRP P  G
S          
       4R 2 4R 2

                S  4R 2
GNUMERIC 
                    P




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 9 of 22


4.1.3. FCC General Limits:

                       Cellular Radiotelephone Service (subpart H of part 22)
    FCC: §1.1307       Non-building-mounted antennas: height above ground level to lowest point of antenna < 10 m and total power
                       of all channels > 1000 W ERP (1640 W EIRP)
                       Personal Communications Services (part 24)
    FCC §1.1307        Broadband PCS (subpart E): non-building-mounted antennas: height above ground level to lowest point of
                       antenna < 10 m and total power of all channels > 2000 W ERP (3280 W EIRP)
                        LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                       Table 1(B) Limits for General Population/Uncontrolled Exposure
    FCC §1.1310        300–1500 MHz: f/1500 mW/cm²
                       1500–100,000 MHz: 1.0 mW/cm²
                       Subject to routine evaluation is required when the device operate at frequencies of 1.5 GHz or below and their
    FCC §2.1091        effective radiated power (ERP) is 1.5 watts or more, or if they operate at frequencies above 1.5 GHz and their
                       ERP is 3 watts or more.

                       (a) Base stations are limited to 1640 watts peak equivalent isotropically radiated power (e.i.r.p.) with an
    FCC §24.232        antenna height up to 300 meters HAAT.
                       b) Mobile/portable stations are limited to 2 watts e.i.r.p. peak power, …

                       (a) Maximum ERP. The effective radiated power (ERP) of base transmitters and cellular repeaters must not
    FCC §22.913        exceed 500 Watts. The ERP of mobile transmitters and auxiliary test transmitters must not exceed 7 Watts.
     FCC §27.50
                       (10) Portable stations (hand-held devices) are limited to 3 watts ERP
      (C )(10)
                       (4) Fixed, mobile, and portable (hand-held) stations operating in the 1710-1755 MHz band are limited to 1
    FCC §27.50(d)      watt EIRP.
                       (2) Mobile and other user stations. Mobile stations are limited to 2.0 watts EIRP. All user stations are limited
    FCC §27.50(h)      to 2.0 watts transmitter output power.




4.1.4. Measurement method

Valid for W-CDMA Mode:

• The power was checked on 3 frequencies (lowest/middle/highest) within the operable FDD-band (see separate
report for W-CDMA technology) and the results compared to applicant’s declared power values (tune-up info).
A RMS detector was used.
• No duty-cycle correction factor is applicable

Please find in the following tables the calculations based on applicants tune-up information (document Power
Tune up procedure for UE866 Products Family, Rel. 1, dated 2015-01-12, Internal Telit Code:
30439NT11303A) for the power values.

Also the maximum admissible allowed antenna gain for shown application is calculated not exceeding the MPE
limit for fixed and mobile operations.




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 10 of 22


4.2. Results for fixed and mobile operations
4.2.1. Results for lower operational band: WCDMA Band V
4.2.1.1. MPE results for FCC

For MPE calculations the declared conducted output power are used. See Tune-up declaration from manufacture
(document Power Tune up procedure for UE866 Products Family, Rel. 1, dated 2015-01-12).

     Operating       Frequency      Declared          Max.       Maxim um    Duty Declared Equivalent
       Mode          on channel    m axim um        positive   output pow er cycle Maxim um conducted
                                   conducted       tolerance    (declared+         conducted   output
                                     output        according     Tune-up)            output    pow er
                                     pow er       m anfacturer                       pow er  (m axim um
                                                                                             conducted
                        (MHz)                                     (dBm )               [W]     output
                                      (dBm )          (dB)                                     pow er
                                      23.00                        24.00                       includ.
      WCDMA             826.4                                                        0.2512    251.19
     FDD Band 5         836.4         23.00           1.00           24.00   100%   0.2512     251.19
    (RMS-Value)                       23.00                          24.00
                        846.6                                                       0.2512     251.19


        Maxim um calculated MPE value:

     MPE-Lim it:        0.551      [m W/cm ^2]
   Highest MPE
                        0.050      [m W/cm ^2]
      value:
  Margin to lim it      0.501      [m W/cm ^2]

Remark: based on 0dBd antenna gain and additional path loss of 0dB




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 11 of 22


4.2.1.2. Max. antenna gain calculations accord. FCC-regulations

Based on valid limits on ERP/EIRP and max. MPE the maximum antenna gain which can be used for the
specific application is calculated.

                                 Maximum antenna gain considerations for fixed/mobile operations for complying with limits:


                                  Maximum pow er delivery at RF-Pad from Module incl. Duty cycle [m W]:
       POUT                                                                                                                   251.19
                                                       (Avg. Burst Pow er or RMS)

     Atten-Pad                                             Attenuation - Path Loss                                             0.0

       PANT                                  Resulting delivered Pow er at antenna input [m W]                                251.19

         R                                                 Safety distance [cm ]:                                             20.00
                                MPE limit acc. §1.1310 and RSS-102 for uncontrolled exposure [m W/cm ²]:
         S                                                                                                                     0.55
                                                     (FCC use mW/cm² & IC use W/m²)
         G1                                Maximum Antenna gain to comply w ith MPE limit [dBi]:                              10.42
(For G1 the low est measured channel to reach minimum ant. Gain selected)


                                      ERP pow er limit according to §2.1091 [W]:
                                                                                                                               1.50
                                            (Avg. Burst Pow er or RMS)
         G2                             Max. Antenna gain to comply w ith limit incl. Duty cycle [dBi]:                        9.91

(For G2 select the max. Avg. Burst Pow er or RMS value incl. Duty cycle)


                                    ERP pow er limit according to §22.913 [W ERP]:                                             7.00
         G3                                Max. Antenna gain to comply w ith limit [dBi]:                                     16.55
(For G3 select the max. Average burst pow er value excluding Duty cycle)


    G 850MHz-Band                                          Min (G1, G2, G3) [dBi]                                              9.91




          Sum m arized              The max. ant. gain for mobile operation at 850 MHz band to comply w ith MPE and
                                                                                                                               7.76
            results:                ERP limits incl. External path loss for show n application shall not exceed [dBd]:




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 12 of 22


4.2.2. Results for upper operational band: WCDMA Band II
4.2.2.1. MPE FCC results

For MPE calculations the declarated conducted output power are used. See Tune-up declaration from
manufacture (document Power Tune up procedure for UE866 Products Family, Rel. 1, dated 2015-01-12).

  Operation    Frequency       Declared     Max. positive      Declared     Duty cycle     Declared       Equivalent
    Mode       on channel     m axim um      tolerance        m axim um                    Maxim um    conducted output
                              conducted      according      output pow er                 conducted pow er (m axim um
                                output      m anfacturer     (Measured+                  output pow er conducted output
                                pow er                        Tune-up)                                   pow er x duty
                                                                                                            cycle)
                                                                                                            (m W)
                   (MHz)        (dBm )           (dB)            (dBm )                       (W)
                   1852.4        23.0                            24.00                       0.251           251
   W-CDMA
  FDD Band 2       1880.0        23.0            1.00            24.00        100%           0.251           251
 (RMS-Value)                                                     24.00
                   1907.6        23.0                                                        0.251           251


    Maxim um calculated MPE value:
 MPE-Lim it:         1       [m W/cm ^2]
Highest MPE
                   0.050     [m W/cm ^2]
   value:
  Margin to
                   0.950     [m W/cm ^2]
    lim it
Remark: based on 0dBi antenna gain and additional path loss of 0dB




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 13 of 22


4.2.2.2. Max. antenna gain calculations accord. FCC-regulations

Based on valid limits on ERP/EIRP and max. MPE the maximum antenna gain which can be used for the
specific application is calculated.

                                    Maxim um antenna gain considerations for fixed/m obile operations for com plying w ith lim its:


                                       Maximum pow er delivery at RF-Pad from Module incl. Duty cycle (mW):
     POUT                                                                                                                             251
                                                           (Avg. Burst Pow er or RMS)

  Atten-Pad                                                     Attenuation - Path Loss                                                0.0

     PANT                                         Resulting delivered Pow er at antenna input [m W]                                   251
      R                                                          Safety distance [cm ]                                                 20
                                     MPE limit acc. §1.1310 and RSS-102 for uncontrolled exposure (m W/cm ²):
      S                                                                                                                               1.00
                                                          (FCC use mW/cm² & IC use W/m²)
      G1                                        Maximum Antenna gain to comply w ith MPE limit (dBi):                                 13.01
(For G1 the low est measured channel to reach minimum ant. Gain selected)


                                              ERP pow er limit according to §2.1091 [W]:
                                                                                                                                      3.00
                                                    (Avg. Burst Pow er or RMS)
      G2                                   Max. Antenna gain to comply w ith this limit incl. Duty cycle (dBi):                       12.92

(For G2 select the max. Avg. Burst Pow er or RMS value incl. Duty cycle)


                                              EIRP pow er limit according to §24.232 [W]:                                             2.00
      G3                             Max. Antenna gain to comply w ith this limit (dBi):                                              9.01
(For G3 select the max. Average burst pow er value excluding Duty cycle)


G 1900MHz-Band                                                  Min (G1, G2, G3) (dBi)                                                9.01




       Sum m arized               The max. ant. gain for mobile operation at 1900 MHz band to comply with MPE and EIRP
                                                                                                                                      9.01
         results:                              limits incl. External path loss for shown application shall not exceed (dBi):




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 14 of 22


4.3. Conclusion for maximum admissible antenna gain (FCC only)

   Max. Gain in Lower operational band (850MHz)
                                                                    7.76 dBd (9.91 dBi)
                                            [dBd]
 Max. Gain in Higher operational band (1900MHz)
                                                                          9.01 dBi
                                             [dBi]
Remark: calculations does not include other may be nearby situated second transmitter (Co-location)




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 15 of 22


4.4. Canada RSS-102, Issue 5 regulations
4.4.1. Exemption Limits:

Exemption Limits for Routine Evaluation — RF Exposure Evaluation

RF exposure evaluation is required if the separation distance between the user and/or bystander and the
device’s radiating element is greater than 20 cm, except when the device operates as follows:

         below 20 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
          than 1 W (adjusted for tune-up tolerance);
         at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum e.i.r.p. of the
          device is equal to or less than 4.49/ƒ0.5 W (adjusted for tune-up tolerance), where ƒ is in MHz;
         at or above 48 MHz and below 300 MHz and the source-based, time-averaged maximum e.i.r.p. of the
          device is equal to or less than 0.6 W (adjusted for tune-up tolerance);
         at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of
          the device is equal to or less than 1.31 x 10 -2 ƒ0.6834 W (adjusted for tune-up tolerance), where ƒ is
          in MHz;
         at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or
          less than 5 W (adjusted for tune-up tolerance).

In these cases, the information contained in the RF exposure technical brief may be limited to information
that demonstrates how the e.i.r.p. was derived.


4.4.1.1. Exemption Limits 850MHz Band:
    Operating       Frequency              Declared             Max.       Maxim um    Duty Declared      Equivalent             Lim it for   Check for
      Mode          on channel            m axim um           positive   output pow er cycle Maxim um    conducted               devices      Exem ption
                                          conducted          tolerance    (declared+         conducted output pow er            operating
                                            output           according     Tune-up)            output    (m axim um             betw een
                                            pow er          m anfacturer                       pow er    conducted             300MHz and
                                                                                                       output pow er               6GHz
                          (MHz)                                             (dBm )              (W)     includ. duty
                                            (dBm )              (dB)                                        cycle)
                                                                                                            (m W)                  (m W)

     WCDMA                826,4              23,0                                24,0                 0,2512       251,19         1290,86        Yes
    FDD Band 5            836,4              23,0               1,0              24,0          100%   0,2512       251,19         1301,51        Yes
   (RMS-Value)
                          846,6              23,0                                24,0                 0,2512       251,19         1312,34        Yes




4.4.1.2. Exemption Limits 1900MHz Band:
 Operation     Frequency      Declared        Max. positive         Declared        Duty cycle      Declared       Equivalent      Lim it for Check for
   Mode        on channel    m axim um         tolerance           m axim um                        Maxim um    conducted output   devices    Exem ption
                             conducted         according         output pow er                     conducted pow er (m axim um operating
                               output         m anfacturer        (Measured+                      output pow er conducted output betw een
                               pow er                              Tune-up)                                       pow er x duty  300MHz and
                                                                                                                     cycle)          6GHz

                 (MHz)            (dBm )             (dB)             (dBm )                          (W)            (m W)          (m W)

   W-CDMA        1852,4            23,0                                24,0                           0,251           251          2241,00       Yes
  FDD Band 2     1880,0            23,0              1,0               24,0             100%          0,251           251          2263,76       Yes
 (RMS-Value)
                 1907,6            23,0                                24,0                           0,251           251          2286,42       Yes




4.4.2. Conclusion: for applications where minimum distance to radiating element is 20cm Annex C of RSS-102
                   should be filled out.




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 16 of 22



4.5. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account
and it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                Calculated uncertainty based
           RF-Measurement                Frequency range                                                   Remarks:
                                                                on a confidence level of 95%
Power Output conducted                   9 kHz .. 20 GHz                    1.0 dB                             --
Power Output radiated                    30 MHz .. 4 GHz                   3.17 dB                   Substitution method
Conducted emissions on antenna ports     9 kHz .. 20 GHz                    1.0 dB                             --
                                        150 kHz .. 30 MHz                   5.0 dB                      Magnetic field
Radiated emissions enclosure             30 MHz .. 1 GHz                    4.2 dB                         E-Field
                                         1 GHz .. 20 GHz                   3.17 dB                   Substitution method
                                          9 kHz .. 4 GHz          0.1272 ppm (Delta Marker )           Frequency error
Occupied bandwidth
                                                                            1.0 dB                           Power
                                            9 kHz .. 4 GHz        0.1272 ppm (Delta Marker)              Frequency error
Emission bandwidth
                                                                            1.0 dB                           Power
Frequency stability                      9 kHz .. 20 GHz                 0.0636 ppm                            --
Conducted emissions                      9 kHz .. 150 kHz                   4.0 dB                             --
on AC-mains port (UCISPR)               150 kHz .. 30 MHz                   3.6 dB

Table: measurement uncertainties, valid for conducted/radiated measurements




5. Abbreviations used in this report
The abbreviations
ANSI                 American National Standards Institute
AV , AVG, CAV        Average detector
EIRP                 Equivalent isotropically radiated power, determined within a separate measurement
EGPRS                Enhanced General Packet Radio Service
EUT                  Equipment Under Test
FCC                  Federal Communications Commission, USA
IC                   Industry Canada
n.a.                 not applicable
Op-Mode              Operating mode of the equipment
PK                   Peak
RBW                  resolution bandwidth
RF                   Radio frequency
RSS                  Radio Standards Specification, Documents from Industry Canada
Rx                   Receiver
TCH                  Traffic channel
Tx                   Transmitter
QP                   Quasi peak detector
VBW                  Video bandwidth
ERP                  Effective radiated power




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 17 of 22



6. Accreditation details of CETECOM’s laboratories and test sites

Ref.-   Accreditation                Valid for laboratory area or test site
No.      Certificate                                                                    Accreditation Body
-          D-PL-                                                                  DAkkS, Deutsche
                        All laboratories and test sites of CETECOM GmbH, Essen
        12047-01-01                                                               Akkreditierungsstelle GmbH
337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                  FCC, Federal Communications
487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
     (MRA US-EU                                                                   Commission
558                 Radiated Measurements above 1 GHz, 3 m (FAR)
         0003)                                                                    Laboratory Division, USA
348                 Mains Ports Conducted Interference Measurements
348                 Telecommunication Ports Conducted Interference Measurem.
337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)              IC, Industry Canada Certification
550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)               and Engineering Bureau
558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                  VCCI, Voluntary Control Council
550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                  for Interference by Information
348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                  Technology Equipment, Japan
348     T-1967      Telecommunication Ports Conducted Interference Measurem.
OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 18 of 22




7. Instruments and Ancillary

7.1. Used equipment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


7.1.1. Test software and firmware of equipment
 Ref.-No.




                           Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
264         Spectrum Analyzer                         FSEK 30                  826939/005          Bios=2.1, Analyzer= 3.20
                                                                                                   UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295         Racal Digital Radio Test Set              6103                     1572
                                                                                                   SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                   R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                   all band used
323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
331         Climatic Test Chamber -40/+80 Grad        HC 4055                  43146               TSI 1.53
335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
383         Signal Generator                          SME 03                   842 828 /034        Firm.= 4.61
389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                   Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                   4.52#002
                                                                                                   R&S Test Firmware Base=5.14, Mess-Software=
436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                   GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                      System CTC-FAR-EMI-
443         CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 8.53
                                                      RSE
444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 8.40
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
460         Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489         EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491         ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524         Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526         Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527         Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528         Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
546         Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                   R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547         Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                   f. all band used, GSM = 5.14 WCDMA: = 5.14
584         Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                   R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597         Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                   not installed, Mainboard= µP1=V.850
598         Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620         EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642         Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
                                                                                                   CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692         Bluetooth Tester                          CBT 32                   100236
                                                                                                   RF)




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 19 of 22



7.1.2. Single instruments and test systems
 Ref.-No.




                                                                                                                              calibration
                                                                                                                              Interval of



                                                                                                                                                Remark
                            Equipment                            Type                   Serial-No.        Manufacturer                                       Cal
                                                                                                                                                             due

001         EMI Test Receiver                         ESS                          825132/017        Rohde & Schwarz          12 M          -            31.05.2015
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                      861741/005        Rohde & Schwarz          12 M          -            31.05.2015
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                      892563/002        Rohde & Schwarz          12 M          -            31.05.2015
009         Power Meter (EMS-radiated)                NRV                          863056/017        Rohde & Schwarz          24 M          -            31.05.2015
016         Line Impedance Simulating Network         Op. 24-D                     B6366             Spitzenberger+Spies      36 M          -            31.03.2016
020         Horn Antenna 18 GHz (Subst 1)             3115                         9107-3699         EMCO                     36/12 M       -            31.03.2017
021         Loop Antenna (H-Field)                    6502                         9206-2770         EMCO                     36 M          -            31.05.2015
030         Loop Antenna (H-field)                    HFH-Z2                       879604/026        Rohde & Schwarz          36 M          -            31.05.2015
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                      879581/18         Rohde & Schwarz          24 M          -            31.05.2015
057         relay-switch-unit (EMS system)            RSU                          494440/002        Rohde & Schwarz          pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                     B6363             Spitzenberger+Spies      -             3
                                                      WRCT 1900/2200-5/40-
066         notch filter (WCDMA; FDD1)                                             5                 Wainwright GmbH          12 M          1g           31.07.2015
                                                      10EEK
086         DC - power supply, 0 -10 A                LNG 50-10                    -                 Heinzinger Electronic    pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S                    -                 Elektro Automatik        pre-m         2
                                                      Helmholtz coil: 2x10 coils
090         Helmholtz coil: 2x10 coils in series                                   -                 RWTÜV                    12 M          4            31.05.2015
                                                      in
091         USB-LWL-Converter                         OLS-1                        007/2006          Ing. Büro Scheiba        -             4
099         passive voltage probe                     ESH2-Z3                      299.7810.52       Rohde & Schwarz          36 M          -            31.05.2015
100         passive voltage probe                     Probe TK 9416                without           Schwarzbeck              36 M          -            31.05.2015
110         USB-LWL-Converter                         OLS-1                        -                 Ing. Büro Scheiba        -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                          G60547            BOCONSULT                36 M          -            31.03.2016
136         adjustable dipole antenna (Dipole 1)      3121C-DB4                    9105-0697         EMCO                     36 M          -            31.05.2015
140         Signal Generator                          SMHU                         831314/006        Rohde & Schwarz          24 M          -            31.03.2016
248         attenuator                                SMA 6dB 2W                   -                 Radiall                  pre-m         2
249         attenuator                                SMA 10dB 10W                 -                 Radiall                  pre-m         2
252         attenuator                                N 6dB 12W                    -                 Radiall                  pre-m         2
256         attenuator                                SMA 3dB 2W                   -                 Radiall                  pre-m         2
257         hybrid                                    4031C                        04491             Narda                    pre-m         2
260         hybrid coupler                            4032C                        11342             Narda                    pre-m         2
261         Thermal Power Sensor                      NRV-Z55                      825083/0008       Rohde & Schwarz          24 M          -            31.03.2016
262         Power Meter                               NRV-S                        825770/0010       Rohde & Schwarz          24 M          -            31.03.2016
263         Signal Generator                          SMP 04                       826190/0007       Rohde & Schwarz          36 M          -            31.03.2016
264         Spectrum Analyzer                         FSEK 30                      826939/005        Rohde & Schwarz          12 M          -            31.05.2015
265         peak power sensor                         NRV-Z33, Model 04            840414/009        Rohde & Schwarz          24 M          -            31.03.2016
266         Peak Power Sensor                         NRV-Z31, Model 04            843383/016        Rohde & Schwarz          24 M          -            31.03.2016
267         notch filter GSM 850                      WRCA 800/960-6EEK            9                 Wainwright GmbH          pre-m         2
270         termination                               1418 N                       BB6935            Weinschel                pre-m         2
271         termination                               1418 N                       BE6384            Weinschel                pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                     BF6239            Weinschel                pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                     BF9229            Weinschel                pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W        BG0321            Weinschel                pre-m         2
275         DC-Block                                  Model 7003 (N)               C5129             Weinschel                pre-m         2
276         DC-Block                                  Model 7006 (SMA)             C7061             Weinschel                pre-m         2
279         power divider                             1515 (SMA)                   LH855             Weinschel                pre-m         2
287         pre-amplifier 25MHz - 4GHz                AMF-2D-100M4G-35-10P         379418            Miteq                    12 M          1c           31.07.2015
291         high pass filter GSM 850/900              WHJ 2200-4EE                 14                Wainwright GmbH          12 M          1c           31.07.2015
298         Univ. Radio Communication Tester          CMU 200                      832221/091        Rohde & Schwarz          pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                      892 239/020       Rohde & Schwarz          12 M          -            31.05.2015
301         attenuator (20 dB) 50W, 18GHz             47-20-33                     AW0272            Lucas Weinschel          pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                     155               Schwarzbeck              36 M          -            31.03.2017
303         horn antenna 40 GHz (Subst 1)             BBHA9170                     156               Schwarzbeck              36 M          -            31.03.2017
341         Digital Multimeter                        Fluke 112                    81650455          Fluke                    24 M          -            31.03.2016
342         Digital Multimeter                        Voltcraft M-4660A            IB 255466         Voltcraft                24 M          -            31.05.2015
347         laboratory site                           radio lab.                   -                 -                        -             5
348         laboratory site                           EMI conducted                -                 -                        -             5
354         DC - Power Supply 40A                     NGPE 40/40                   448               Rohde & Schwarz          pre-m         2
355         Power Meter                               URV 5                        891310/027        Rohde & Schwarz          24 M          -            31.03.2016
356         power sensor                              NRV-Z1                       882322/014        Rohde & Schwarz          24 M          -            31.05.2015
357         power sensor                              NRV-Z1                       861761/002        Rohde & Schwarz          24 M          -            31.05.2015
371         Bluetooth Tester                          CBT32                        100153            R&S                      24 M          -            31.03.2016
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                      100535            Rohde & Schwarz          24 M          -            31.03.2016
376         Horn Antenna 6 GHz                        BBHA9120 E                   BBHA 9120 E 179   Schwarzbeck              12 M          -            31.05.2015
377         EMI Test Receiver                         ESCS 30                      100160            Rohde & Schwarz          12 M          -            31.05.2015
389         Digital Multimeter                        Keithley 2000                0583926           Keithley                 24 M          -            31.05.2015
392         Radio Communication Tester                MT8820A                      6K00000788        Anritsu                  12 M          -            31.05.2015
431         Model 7405                                Near-Field Probe Set         9305-2457         EMCO                     -             4
436         Univ. Radio Communication Tester          CMU 200                      103083            Rohde & Schwarz          12 M          -            31.05.2015
439         UltraLog-Antenna                          HL 562                       100248            Rohde & Schwarz          36 M          -            31.03.2017
                                                      System CTC-FAR-EMI-                            ETS-Lindgren /
443         CTC-FAR-EMI-RSE                                                        -                                          12 M          5            31.07.2015
                                                      RSE                                            CETECOM
448         notch filter WCDMA_FDD II                 WRCT 1850.0/2170.0-          5                 Wainwright Instruments   12 M          1c           31.07.2015


TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 20 of 22


 Ref.-No.




                                                                                                                                  calibration
                                                                                                                                  Interval of



                                                                                                                                                    Remark
                             Equipment                           Type                     Serial-No.              Manufacturer                                   Cal
                                                                                                                                                                 due

                                                      5/40-                                               GmbH
                                                      WRCT 824.0/894.0-5/40-
449         notch filter WCDMA FDD V                                              1                       Wainwright              12 M          1c           31.07.2015
                                                      8SSK
454         Oscilloscope                              HM 205-3                    9210 P 29661            Hameg                   -             4
456         DC-Power supply 0-5 A                     EA 3013 S                   207810                  Elektro Automatik       pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50               910722                  Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester          CMU 200                     108901                  Rohde & Schwarz         12 M          -            31.05.2015
463         Universal source                          HP3245A                     2831A03472              Agilent                 -             4
466         Digital Multimeter                        Fluke 112                   89210157                Fluke USA               24 M          -            31.03.2016
467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA               36 M          -            31.05.2015
468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA               36 M          -            31.05.2015
477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink   -             3
480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz         24 M          -            31.05.2015
482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)           -             1d
                                                      AMF-5D-02501800-25-
484         pre-amplifier 2,5 - 18 GHz                                            1244554                 Miteq                   12 M          -            31.07.2015
                                                      10P
                                                      System EMI field (SAR)                              ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                   -                                               24 M          -            30.06.2015
                                                      NSA                                                 CETECOM
489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz         12 M          -            31.05.2015
                                                      WRCG 1709/1786-
502         band reject filter                                                    SN 9                    Wainwright              pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright              pre-m         2
                                                      WRCA 800/960-02/40-
512         notch filter GSM 850                                                  SN 24                   Wainwrght               12 M          1c           31.07.2015
                                                      6EEK
517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                pre-m         2
523         Digital Multimeter                        L4411A                      MY46000154              Agilent                 24 M          -            31.05.2015
529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel               pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                       pre-m         2
546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                     12 M          -            12.02.2015
547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz         12 M          -            31.05.2015
548         Digital-Barometer                         GBP 2300                    without                 Greisinger GmbH         36 M          -            30.06.2015
549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz         36/12 M       -            31.05.2015
552         high pass filter 2,8-18GHz                WHKX 2.8/18G-10SS           4                       Wainwright              12 M          1c           31.07.2015
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                                 -                       CTC                     24 M          -            31.07.2015
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia               36/12 M       -            31.03.2016
584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz         pre-m         -
597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz         36 M          -            31.03.2016
598         Spectrum Analyzer                         FSEM 30 (Reserve)           831259/013              Rohde & Schwarz         24 M          -            13.01.2015
600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz         24 M          -            31.05.2015
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz         24 M          -            31.05.2015
602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz         24 M          -            31.05.2015
611         DC power supply                           E3632A                      KR 75305854             Agilent                 pre-m         2
612         DC power supply                           E3632A                      MY 40001321             Agilent                 pre-m         2
613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                 pre-m         2
616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                   24 M          -            31.03.2016
617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits           -             2
618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA      -             2
619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA     -             3
620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz           12 M          -            31.05.2015
621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz         pre-m         2
625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                 -             2
                                                                                  201.0999.9302.6.4.1.4
627         data logger                               OPUS 1                                              G. Lufft GmbH           36 M          -            30.05.2015
                                                                                  3
634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz         pre-m         2
636         Thermal Imaging camera                    Ti32                        Ti32-12060213           Fluke Corporation       36 M          -            31.07.2015
                                                      HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                -             2
                                                      1m
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                -             2
642         Wideband Radio Communication Tester       CMW 500                     126089                  Rohde&Schwarz           12 M          -            31.05.2015
644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits           -             -
670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz         12 M          -            31.05.2015
671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik       pre-m         2
678         Power Meter                               NRP                         101638                  Rohde&Schwarz           pre-m         -
                                                                                                          Narda Safety Test
686         Field Analyzer                            EHP-200A                    160WX30702                                      24 M          -            18.07.2015
                                                                                                          Solutions
688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                   pre-m         -
692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz         12 M          -            31.05.2015
693         TS8997                                    CTC-Radio Lab 1_TS8997      -                       Rohde&Schwarz           12 M          5            31.05.2015




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 21 of 22


7.1.3. Legend
Note / remarks                      Calibrated during system calibration:
                          1a        System CTC-SAR-EMS (Ref.-No. 442)
                          1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                          1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                          1d        System CTC-SAR-EMI (Ref.-No . 441)
                          1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                          1f        System CTC-CTIA-OTA (Ref.-No . 420)
                          1g        System CTC-FAR-EMS (Ref.-No . 444)
                          2         Calibration or equipment check immediately before measurement
                          3         Regulatory maintained equipment for functional check or support purpose
                          4         calibration of this equipment
                                    Ancillary equipment   without has no effect
                                                                  calibration   onmechanical
                                                                              e.g. measuring result
                                                                                             equipment or monitoring equipment
                          5         Test System


Interval of calibration   12 M      12 month
                          24 M      24 month
                          36 M      36 month
                          24/12 M   Calibration every 24 months, between this every 12 months internal validation
                          36/12 M   Calibration every 36 months, between this every 12 months internal validation
                          Pre-m     Check before starting the measurement
                          -         Without calibration




TR6-0608-14-1-4b


Test Report 6-0608-14-1-4b, Page 22 of 22


7.1.4. Legend
Note / remarks                       Calibrated during system calibration:
                           1a        System CTC-SAR-EMS (Ref.-No. 442)
                           1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                           1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                           1d        System CTC-SAR-EMI (Ref.-No . 441)
                           1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                           1f        System CTC-CTIA-OTA (Ref.-No . 420)
                           1g        System CTC-FAR-EMS (Ref.-No . 444)
                           2         Calibration or equipment check immediately before measurement
                           3         Regulatory maintained equipment for functional check or support purpose
                           4         calibration of this equipment
                                     Ancillary equipment   without has no effect
                                                                   calibration   onmechanical
                                                                               e.g. measuring result
                                                                                              equipment or monitoring equipment
                           5         Test System


Interval of calibration    12 M      12 month
                           24 M      24 month
                           36 M      36 month
                           24/12 M   Calibration every 24 months, between this every 12 months internal validation
                           36/12 M   Calibration every 36 months, between this every 12 months internal validation
                           Pre-m     Check before starting the measurement
                           -         Without calibration




8. Versions of test reports (change history)

      Version             Applied changes                                                                                         Date of release
        --                Initial release                                                                                          2015-04-20




TR6-0608-14-1-4b



Document Created: 2015-05-06 16:13:55
Document Modified: 2015-05-06 16:13:55

© 2024 FCC.report