Test report

FCC ID: RI7ME910C1WW

Test Report

Download: PDF
FCCID_4391036

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                                                                   Test report No:
                                                                                                 NIE: 60375REM.001



          Test report
          FCC Rules and Regulations CFR 47, Part 15,
          Subpart B (10-1-16 Edition) & ICES-003 Issue 6
          (Updated 04-2017)
          (*) Identification of item tested                  LTE Module CATM and NB-IOT


          (*) Trademark                                      Telit


          (*) Model and /or type reference tested            ME910C1-WW


          Other identification of the product                FCC ID: RI7ME910C1WW
                                                             IC: 5131A-ME910C1WW
                                                             IMEI TAC: 35308109
          (*) Features                                       LTE CATM/NB-IOT /Quad Band 2G


          Manufacturer                                       Telit Communications S.p.A
                                                             Via Stazione di Prosecco 5/B, 34010 Sgonico,
                                                             Trieste - ITALY
          Test method requested, standard                    FCC CFR 47, Part 15, Subpart B (10-1-16 Edition)
                                                             & ICES-003 (Updated 04-2017)

          Summary                                            IN COMPLIANCE

          Approved by (name / position & signature)          Rafael López                               RAFAEL LÓPEZ
                                                                                                        MARTÍN
                                                             EMC LAB Manager                            2019.07.02
                                                                                                        14:35:11 +02'00'
          Date of issue                                      2019-06-21


          Report template No                                 FDT08_22
                                                             (*) “Data provided by the client”




Report No: (NIE) 60375REM.001                                                                                          2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                                   Index


   Competences and guarantees .................................................................................................... 3
   General conditions ...................................................................................................................... 3
   Uncertainty ................................................................................................................................. 3
   Data provided by the client.......................................................................................................... 4
   Usage of samples ....................................................................................................................... 4
   Test sample description .............................................................................................................. 5
   Identification of the client............................................................................................................. 6
   Testing period and place ............................................................................................................. 6
   Document history ........................................................................................................................ 6
   Environmental conditions ............................................................................................................ 7
   Remarks and comments ............................................................................................................. 8
   Testing verdicts........................................................................................................................... 8
   Summary .................................................................................................................................... 8
   Appendix A: Test results ............................................................................................................. 9




Report No: (NIE) 60375REM.001                                        Page 2 of 16                                                            2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Competences and guarantees
   DEKRA Testing and Certification is a testing laboratory accredited by the National Accreditation Body (ENAC -
   Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
   DEKRA Testing and Certification is a FCC recognized accredited testing laboratory with appropriate scope of
   accreditation that include testing performed in this test report, FCC designation number ES0004.
   In order to assure the traceability to other national and international laboratories, DEKRA Testing and
   Certification has a calibration and maintenance program for its measurement equipment.
   DEKRA Testing and Certification guarantees the reliability of the data presented in this report, which is the
   result of the measurements and the tests performed to the item under test on the date and under the conditions
   stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and
   Certification at the time of performance of the test.
   DEKRA Testing and Certification is liable to the client for the maintenance of the confidentiality of all information
   related to the item under test and the results of the test.
   The results presented in this Test Report apply only to the particular item under test established in this
   document.
   IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
   except in full, without the previous written permission of DEKRA Testing and Certification.


General conditions
       1. This report is only referred to the item that has undergone the test.
       2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
          or competent Authorities.
       3. This document is only valid if complete; no partial reproduction can be made without previous written
          permission of DEKRA Testing and Certification.
       4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
          previous written permission of DEKRA Testing and Certification and the Accreditation Bodies.


Uncertainty
   Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification internal document
   PODT000.

   The total uncertainty of the measurement system for the measured conducted disturbance characteristics of
   EUT from 150kHz to 30 MHz is I = ± 3,9 dB for quasi-peak measurements, I = ± 3,2 dB for average
   measurements (k = 2)

   The total uncertainty of the measurement system for the measured radio disturbance characteristics of EUT
   from 30 MHz to 1000 MHz is I = ± 4,9 dB for quasi-peak measurements, I = ± 4,6 dB for peak measurements (k
   = 2)

   The total uncertainty of the measurement system for the measured radio disturbance characteristics of EUT
   from 1000 MHz to 26 GHz is I = ± 2,6 dB for peaks and average measurements (k = 2)




Report No: (NIE) 60375REM.001                                Page 3 of 16                                    2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Data provided by the client
   The sample consists of a LTE module CAT M and NB-IOT with 2G Fallback.
   DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by
   the client and that may affect the validity of results.


Usage of samples
   Samples under test have been selected by: The client.
   Sample S/01 is composed of the following elements:

                                                                                                                   Date of
     Control Nº              Description                       Model                    Serial Nº
                                                                                                                  reception

     60375B/001                  Module                      ME910C1-WW               IMEI: 35308109             2019-02-07

     60375B/003              LTE antenna                         ---                        ---                  2019-02-07



   Auxiliary elements used with the tested sample:

     Control Nº               Description                                Model                    Serial Nº   Date of reception
     60375B/002                EVK Board                                   ---                       ---         2019-02-07




Report No: (NIE) 60375REM.001                                          Page 4 of 16                                     2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Test sample description
Ports………………………………. :                                                                                     Cable
                                                     Port name and description
                                                                                         Specified        Attached         Shielded
                                                                                        length [m]       during test

                                                     Not provided data




Supplymentary information to the                     Not provided data
ports………………………………. :
Rated power supply .................... :                                                            Reference poles
                                                     Voltage and Frequency
                                                                                         L1      L2        L3          N       PE

                                                             AC:

                                                             AC:

                                                             DC: 3.8Vdc.

                                                             DC:

Rated Power ............................... :        Not provided data
Clock frequencies ....................... :          Not provided data
Other parameters ........................ :          Not provided data
Software version ......................... :         M0B.800004
Hardware version ........................ :          0.0
Dimensions in mm (W x H x D)... :                    Not provided data
Mounting position ........................ :                 Table top equipment
                                                             Wall/Ceiling mounted equipment
                                                             Floor standing equipment
                                                             Hand-held equipment
                                                             Other: Module
Modules/parts ............................. :        Module/parts of test item                Type                Manufacturer

                                                     Not provided data




Report No: (NIE) 60375REM.001                                      Page 5 of 16                                             2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


 Accessories (not part of the test                      Description                    Type            Manufacturer
 item) ............................................ :
                                                        Not provided data




 Documents as provided by the                           Description                    File name       Issue date
 applicant ...................................... :
                                                        Not provided data




Identification of the client
TELIT COMMUNICATIONS
Via Stazione di Prosecco 5/B, 34010 Sgonico,
Trieste – ITALY.


Testing period and place
       Test Location                 DEKRA Testing and Certification S.A.U.
         Date (start)                2019-02-07
        Date (finish)                2019-02-08


Document history
   Report number                         Date                                            Description
   60375REM.001                    2019-06-21           First release




Report No: (NIE) 60375REM.001                                           Page 6 of 16                         2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




Environmental conditions


   In the control chamber, the following limits were not exceeded during the test:


                                                              Min. = 15 ºC
             Temperature
                                                              Max. = 35 ºC
                                                              Min. = 30 %
             Relative humidity
                                                              Max. = 75 %
                                                              Min. = 860 mbar
             Air pressure
                                                              Max. = 1060 mbar




   In the semianechoic chamber, the following limits were not exceeded during the test.


                                                             Min. = 15 ºC
             Temperature
                                                             Max. = 35 ºC
                                                             Min. = 30 %
             Relative humidity
                                                             Max. = 75 %
                                                             Min. = 860 mbar
             Air pressure
                                                             Max. = 1060 mbar




   In the chamber for conducted measurements, the following limits were not exceeded during the test:


             Temperature                                      Min. = 15 ºC
                                                              Max. = 35 ºC
             Relative humidity                                Min. = 30 %
                                                              Max. = 60 %
             Air pressure                                     Min. = 860 mbar
                                                              Max. = 1060 mbar




Report No: (NIE) 60375REM.001                                Page 7 of 16                               2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Remarks and comments
The test have been performed by the technical personnel: Jesús García & Lorena Oviedo.
DEKRA declines any responsibility with respect to the information provided by the client and that may affect the
validity of results.


Testing verdicts

                          Not applicable :                                                N/A

                          Pass       :                                                    P

                          Fail       :                                                    F

                          Not measured :                                                  N/M



Summary

                                                             Emission Test
                                         Requirement – Test case                                 Verdict    Remark
 Radiated emission. Electromagnetic field measure (30 KHz – 1000 MHz)                               P          ---
 Radiated emission. Electromagnetic field measure (1 GHz – 18 GHz)                                  P          ---
 Continuous conducted emission (150 KHz – 30 MHz)                                                   N/A        (1)
 Supplymentary information and remarks:
       (1) Equipment DC powered. Test applicable only in AC port.




Control                                                                                                    Next
                    Description                                Model              Manufacturer
Number                                                                                                     Calibration

2942                EMI TEST RECEIVER 20Hz-40GHz               ESU40              ROHDE AND SCHWARZ        2020-06-19

                    ETHERNET TEMPERATURE AND
3556                                                           TR-72W             T&D                      2019-04-11
                    HUMIDITY LOGGER

                                                                                  SCHWARZBECK MESS-
4612                HORN ANTENNA 1-18GHz                       BBHA 9120 D                                 2021-06-14
                                                                                  ELEKTRONIK

6120                PRE-AMPLIFIER G>38dB 30MHz-6GHz            BLNA 0360-01N      BONN ELEKTRONIK          2019-07-27

                                                               AMF-7D-01001800-
6196                PRE-AMPLIFIER G>55dB 1-18GHz                                  NARDA                    2019-12-10
                                                               22-10P

6815                HYBRID BILOG ANTENNA 30MHz-6GHz            3142E              ETS LINDGREN             2022-02-01




Report No: (NIE) 60375REM.001                                  Page 8 of 16                                    2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




     Appendix A: Test results




Report No: (NIE) 60375REM.001                                Page 9 of 16   2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                APPENDIX A CONTENT

   DESCRIPTION OF THE OPERATION MODES ........................................................................ 11
   RADIATED EMISSION. ELECTROMAGNETIC FIELD MEASURE ........................................... 12




Report No: (NIE) 60375REM.001                                Page 10 of 16                                   2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



DESCRIPTION OF THE OPERATION MODES
The operation modes used by the samples to which the present report refers, are shown in the following table:


        OPERATION                                                 DESCRIPTION
          MODE
            OM#01                   EUT ON. NB-IoT Band 12 in IDLE mode. Power supply: 3.8Vdc. (worst case)




Report No: (NIE) 60375REM.001                                Page 11 of 16                                    2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




RADIATED EMISSION. ELECTROMAGNETIC FIELD MEASURE


                         Product standard:               FCC CFR 47, Part 15, Subpart B (10-1-16 Edition) & ICES-003
                                                         (Updated 04-2017)
    LIMITS:
                           Test standard:                FCC CFR 47, Part 15, Subpart B (10-1-16 Edition) & ICES-003
                                                         (Updated 04-2017)
Limits of interference Class B
The applied limit for radiated emissions, 3 m distance, according with the requirements of FCC Rules and
Regulations 47 CFR Part 15, Subpart B (10-1-16 Edition), Secs. 15.109 & ICES-003 Issue 6 (Updated 04-
2017) in the frequency range 30 MHz to 26 GHz for class B devices.




                                                       Setup for measurements < 1GHz.




                                                       Setup for measurements > 1GHz.

Report No: (NIE) 60375REM.001                                    Page 12 of 16                                  2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                TESTED SAMPLE:                                                          S/01

       TESTED OPERATION MODES:                                                       OM#01
                                                             CRmmnnRRPP: CR, Radiated Condition; mm: Sample number; nn:
                 TEST RESULTS:
                                                                    Operation mode; RR: Range; PP: Polarization.




          CRmmnnRRPP                                           Description                                  Result
            CR0101LR                     Range: 30 MHz - 1000 MHz.                                            P
          CR0101HR1_H                    Range: 1 GHz - 18 GHz. Horizontal polarization.                      P
          CR0101HR1_V                    Range: 1 GHz - 18 GHz. Vertical polarization.                        P
          CR0101HR1_H                    Range: 18 GHz - 26 GHz. Horizontal polarization.                     P
          CR0101HR1_V                    Range: 18 GHz - 26 GHz. Vertical polarization.                       P




Report No: (NIE) 60375REM.001                                    Page 13 of 16                                 2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Radiated Emission. CR0101LR




  Project:                                         60375REM.001
  Company:                                         TELIT COMMUNICATIONS S.P.A.
  Sample:                                          S/01
  Operation mode:                                  OM#01
  Description:                                     EUT ON. LTE OFF. Power Supply: 3.8 Vdc.




Maximizations
     Frequency          QuasiPeak       MaxPeak          Limit     Margin    Height    Pol   Azimuth
       (MHz)            (dBµV/m)        (dBµV/m)       (dBµV/m)     (dB)      (cm)            (deg)
        30.510450            16.15          22.88          40.00     23.85     223.0   V       -128.0
       156.842500            12.01          18.16          43.50     31.49     101.0   V         56.0
       204.092500            12.96          19.29          43.50     30.54     184.0   V       -169.0
       545.222500            25.02          31.26          46.00     20.98     168.0   V        149.0
       763.597500            28.16          34.12          46.00     17.84     330.0   H        -60.0
       929.280000            30.65          37.45          46.00     15.35     285.0   H         39.0




Report No: (NIE) 60375REM.001                                      Page 14 of 16                        2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Radiated Emission. CR0101HR1_H




  Project:                                                   60375REM.001
  Company:                                                   TELIT COMMUNICATION S.P.A.
  Sample:                                                    S/01
  Operation mode:                                            OM#01
  Description:                                               EUT ON. LTE OFF. Power Supply: 3.8 Vdc. Horizontal polarization

ER EMI FCC 15 Class B (1-18GHz)

                            80
                                                                                     FCC Part 15 Class B Electric Field Strength PK
                            70

                            60
                                                                              FCC Part 15 Class B Electric Field Strength QP+AV
          Level in dBµV/m




                            50

                            40

                            30

                            20

                            10

                            0
                             1G                         2G        3G       4G        5G     6        8     10G                18G
                                                                       Frequency in Hz

                                 Av erage Sc an
                                 Peak Sc an
                                 FCC Part 15 Class B Electric Field Strength PK
                                 FCC Part 15 Class B Electric Field Strength QP+AV



Subrange Maxima
      Frequency                         PK+_CLRWR        AVG_CLRWR
        (MHz)                            (dBµV/m)         (dBµV/m)

        2202.800000                              26.5           13.5
        4396.400000                              31.0           17.7
        6065.200000                              33.4           20.2
        7355.600000                              38.6           25.2
        9399.200000                              40.7           27.7
       10830.400000                              43.4           29.6
       12880.400000                              42.4           29.8
       14487.200000                              44.1           30.4
       14872.000000                              44.0           30.6
       17948.800000                              54.2           40.7




Report No: (NIE) 60375REM.001                                               Page 15 of 16                                             2019-06-21


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Radiated Emission. CR0101HR1_V




  Project:                                                   60375REM.001
  Company:                                                   TELIT COMMUNICATION S.P.A.
  Sample:                                                    S/01
  Operation mode:                                            OM#01
  Description:                                               EUT ON. LTE OFF. Power Supply: 3.8 Vdc.Vertical polarization

ER EMI FCC 15 Class B (1-18GHz)

                            80
                                                                                     FCC Part 15 Class B Electric Field Strength PK
                            70

                            60
                                                                              FCC Part 15 Class B Electric Field Strength QP+AV
          Level in dBµV/m




                            50

                            40

                            30

                            20

                            10

                            0
                             1G                         2G        3G       4G        5G     6        8     10G                18G
                                                                       Frequency in Hz

                                 Av erage Sc an
                                 Peak Sc an
                                 FCC Part 15 Class B Electric Field Strength PK
                                 FCC Part 15 Class B Electric Field Strength QP+AV



Subrange Maxima
      Frequency                         PK+_CLRWR        AVG_CLRWR
        (MHz)                            (dBµV/m)         (dBµV/m)

        1801.200000                              26.7           11.0
        4387.200000                              30.8           17.8
        6053.200000                              34.0           20.2
        7318.800000                              38.7           25.1
        9285.200000                              41.3           27.9
       10831.200000                              42.9           29.8
       12870.000000                              42.6           30.0
       13966.800000                              44.1           30.8
       14889.600000                              44.2           31.1
       17987.600000                              54.1           41.2




Report No: (NIE) 60375REM.001                                               Page 16 of 16                                             2019-06-21



Document Created: 2019-07-02 14:35:11
Document Modified: 2019-07-02 14:35:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC