Test report

FCC ID: RI7ME910C1P2

Test Report

Download: PDF
FCCID_4393546

DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




                                                      FCC LISTED, REGISTRATION
                                                      NUMBER: 2764.01                       Test report No:
                                                      ISED LISTED REGISTRATION              2528ERM.002
                                                      NUMBER: 23595-1



                                                Test report
         FCC Rules and Regulations CFR 47, Part 15, Subpart B (10-1-18 Edition)
                                         &
                       ICES-003 ISSUE 6 – Update April (2017)


          Identification of item tested
                                                          Module ME910C1-P2 assembled on interface board


          Trademark                                       Telit


          Model and /or type reference                    ME910C1-P2

          Other identification of the product             FCC ID: RI7ME910C1P2
                                                          IC: 5131A-ME910C1P2
          Features                                        LTE CAT/NB.IOT with 2G Fallback


          Manufacturer                                    TELIT COMMUNICATIONS SPA
                                                          Via Stazione di Prosecco 5/B - (TS) Italy


          Test method requested, standard                 FCC Rules and Regulations CFR 47, Part 15, Subpart B
                                                          (10-1-18 Edition)
                                                          ICES-003 ISSUE 6 – Update April (2017)

          Summary                                         IN COMPLIANCE


          Approved by (name / position & signature)       Domingo Galvez                              Digitally signed by Domingo
                                                                                                      Galvez
                                                          EMC&RF Lab Manager                          DN: cn=Domingo Galvez,
                                                                                                      o=DEKRA Certification Inc.,
                                                                                                      ou=Regulatory Lab,
                                                                                                      email=dgalvez@dekra.com,
                                                                                                      c=US
                                                                                                      Date: 2019.05.29 18:04:47
                                                                                                      -04'00'

          Date of issue                                   2019-05-01

          Report template No                              FDT08_21




Report No: 2528ERM.002                                                                                                      2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




                                                                   Index
   Competences and guarantees .................................................................................................... 3
   General conditions ...................................................................................................................... 3
   Uncertainty ................................................................................................................................. 3
   Data provided by the client.......................................................................................................... 4
   Usage of samples ....................................................................................................................... 4
   Test sample description .............................................................................................................. 5
   Identification of the client............................................................................................................. 6
   Testing period and place ............................................................................................................. 6
   Document history ........................................................................................................................ 6
   Environmental conditions ............................................................................................................ 7
   Remarks and comments ............................................................................................................. 7
   Testing verdicts........................................................................................................................... 8
   Summary .................................................................................................................................... 8
   List of equipment used during the test......................................................................................... 8
   Appendix A: Test results ............................................................................................................. 9




Report No: 2528ERM.002                                               Page 2 of 15                                                            2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Competences and guarantees
   DEKRA Certification Inc. is a testing laboratory accredited by A2LA (The American Association for Laboratory
   Accreditation), to perform the tests indicated in the Certificate 2764.01
   DEKRA Certification Inc. is a testing laboratory competent to carry out the tests described in this report.
   In order to assure the traceability to other national and international laboratories, DEKRA Certification Inc. has a
   calibration and maintenance program for its measurement equipment.
   DEKRA Certification Inc. guarantees the reliability of the data presented in this report, which is the result of the
   measurements and the tests performed to the item under test on the date and under the conditions stated on
   the report and, it is based on the knowledge and technical facilities available at DEKRA Certification at the time
   of performance of the test.
   DEKRA Certification Inc. is liable to the client for the maintenance of the confidentiality of all information related
   to the item under test and the results of the test.
   The results presented in this Test Report apply only to the particular item under test established in this
   document.
   IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
   except in full, without the previous written permission of DEKRA Certification Inc.


General conditions
       1. This report is only referred to the item that has undergone the test.
       2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
          or competent Authorities.
       3. This document is only valid if complete; no partial reproduction can be made without previous written
          permission of DEKRA Certification Inc.
       4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
          previous written permission of DEKRA Certification Inc. and the Accreditation Bodies.


Uncertainty
   Uncertainty (factor k=2) was calculated according to the DEKRA Certification internal document PODT000.


                                                       Frequency (MHz) U(k=2)       Units
                              Conducted emission          0,009 - 30    2.69        dB
                                                            30-180      3.82        dB
                                                          180-1000      2.61        dB
                              Radiated emission
                                                         1000-18000     2.92        dB
                                                        18000-40000     2.15        dB




Report No: 2528ERM.002                                Page 3 of 15                                            2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Data provided by the client
   LTE module CAT M and NB-IOT with 2G Fallback
   DEKRA declines any responsibility with respect to the information provided by the client and that may affect the
   validity of results.


Usage of samples
   Samples undergoing test have been selected by: The client.
   Sample S/01 is composed of the following elements:

                                                                                                   Date of
     Control Nº                Description               Model               Serial Nº
                                                                                                  reception

       2428.02              Telit ME910C1-P2    Telit ME910C1-P2        35580910003321             4/23/2019

       2428.08              Magnetic Base LTE   700-960/1710-2700               -                  4/23/2019
                                Antenna

       2428.15              Magnetic BaseLTE    700-960/1710-2700               -                  4/23/2019
                                Antenna

   Following accessories were used with Sample S/01 to perform the testing

                                                                                                   Date of
     Control Nº                Description               Model               Serial Nº
                                                                                                  reception

       2428.05               Telit ME910C1-       Evaluation Kit2          090007745               4/23/2019
                            P2_Evaluation Kit
                             DC Power cable
       2428.12                                           -                      -                  4/23/2019


   Sample S/01 was used in following testing: Radiated Emission




Report No: 2528ERM.002                                Page 4 of 15                                       2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Test sample description
Ports………………………………. :                                                                              Cable

                                                Port name and description        Specified   Attached during    Shielded
                                                                                  length           test
                                                                                    [m]

                                                No Data Provided




Supplementary information to the
                                                No Data Provided
ports………………………………. :
Rated power supply .................... :                                                    Reference poles
                                                Voltage and Frequency
                                                                                 L1    L2    L3            N       PE

                                                     AC: 230Vac / 50Hz.
                                                     AC:
                                                     DC:
                                                     DC:
Rated Power ............................... :   No Data Provided
Clock frequencies ....................... :     No Data Provided
Other parameters ........................ :     No Data Provided
Software version ......................... :    M0B.950004
Hardware version ........................ :     HW 0.0
Dimensions in cm (L x W x D) .... :             No Data Provided
Mounting position ........................ :          Table top equipment
                                                      Wall/Ceiling mounted equipment
                                                      Floor standing equipment
                                                      Hand-held equipment
                                                      Other:
Modules/parts ............................. :   Module/parts of test item                    Type         Manufacturer

                                                No Data provided




Report No: 2528ERM.002                                      Page 5 of 15                                       2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Accessories (not part of the test                      Description                    Type                            Manufacturer
item) ............................................ :

Documents as provided by the                           Description                    File name                       Issue date
applicant ...................................... :
                                                       Equipment                      FDT30_15_Declaration_Equipment_ -
                                                       declaration data               Data ME910C1-P2

                                                              Copy of marking plate:




Identification of the client
   TELIT COMMUNICATIONS SPA
   Via Stazione Prosecco 5/B – (TS) Italy.


Testing period and place
      Test Location                 DEKRA Certification, Inc
        Date (start)                2019-04-26
       Date (finish)                2019-04-26


Document history
  Report number                         Date                                                 Description
   2528ERM.002                    2019-05-01           First release




Report No: 2528ERM.002                                                 Page 6 of 15                                       2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Environmental conditions

   In the control chamber, the following limits were not exceeded during the test:


                                                      Min. = 15 ºC
             Temperature
                                                      Max. = 35 ºC
                                                      Min. = 30 %
             Relative humidity
                                                      Max. = 75 %
                                                      Min. = 860 mbar
             Air pressure
                                                      Max. = 1060 mbar


   In the semi anechoic chamber, the following limits were not exceeded during the test.


                                                      Min. = 15 ºC
             Temperature
                                                      Max. = 35 ºC
                                                      Min. = 30 %
             Relative humidity
                                                      Max. = 75 %
                                                      Min. = 860 mbar
             Air pressure
                                                      Max. = 1060 mbar


   In the chamber for conducted measurements, the following limits were not exceeded during the test:


             Temperature                              Min. = 15 ºC
                                                      Max. = 35 ºC
             Relative humidity                        Min. = 30 %
                                                      Max. = 60 %
             Air pressure                             Min. = 860 mbar
                                                      Max. = 1060 mbar


Remarks and comments
The tests have been performed by the technical personnel: Koji Nishimoto & Poojita Bhattu




Report No: 2528ERM.002                               Page 7 of 15                                       2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Testing verdicts


                            Not applicable :                                          N/A

                            Pass    :                                                 P

                            Fail    :                                                 F

                            Not measured :                                            N/M



Summary
                                                        Emission Test
 Report                                    Requirement – Test case
                                                                                              Verdict       Remark
 Section
    A.1.       Radiated emission electromagnetic field test (30 MHz – 1000 MHz)                     P          N/A
    A.1.       Radiated emission electromagnetic field test (1 GHz – 18 GHz)                        P        Refer 1
     -.        Radiated emission electromagnetic field test (18 GHz – 40 GHz)                   N/A          Refer 1
     -.        Conducted emission test (150 kHz to 30 MHz)                                      N/A          Refer 2
Supplementary information and remarks:
      1)   As per standard 47 CFR §15.33 due to the highest frequency generated or used in the device is above 1000MHz
           the upper frequency of measurement range is up to 5th harmonic of the highest frequency or 40GHz, whichever is
           lower.
      2)   DUT is a module and not the final product.




List of equipment used during the test
 CONTROL                                                                                 LAST                 NEXT
                       DESCRIPTION             MANUFACTURER               MODEL
 NUMBER                                                                               CALIBRATION          CALIBRATION
                                                   BONN                  BLNA 0360-
     0980                   Preamplifier                                                    2017/05            2019/05
                                                ELEKTRONIK                  01N
                                                   BONN
     0981                   Preamplifier                             BLMA 0118-2A           2018/10            2020/10
                                                ELEKTRONIK
     0982                                          BONN
                            Preamplifier                             BLMA1840-1M            2018/10            2020/10
                                                ELEKTRONIK
                                                 ROHDE &
     1012            EMI Test Receiver                                     ESR26            2018/09            2020/09
                                                 SCHWARZ
                    EMC measurement              ROHDE &
     1017                                                            EMC32 V9.01              ---                 ---
                        software                 SCHWARZ
     1039                                        ROHDE &
                       Signal Analyser                                     FSV40            2018/10            2020/10
                                                 SCHWARZ
     1055              Horn Antenna            ETS LINDGREN                3116C            2016/12            2019/12
     1058              Horn Antenna            ETS LINDGREN                 3115            2017/03            2020/03
     1065            Biconilog Antenna         ETS LINDGREN                3142E            2017/03            2020/03




Report No: 2528ERM.002                                    Page 8 of 15                                           2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




     Appendix A: Test results




Report No: 2528ERM.002      Page 9 of 15   2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




                                      Appendix A Content

   DESCRIPTION OF THE OPERATION MODES ........................................................................ 11
   A.1.RADIATED EMISSION. ELECTROMAGNETIC FIELD TEST ............................................. 12




Report No: 2528ERM.002                               Page 10 of 15                                           2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




DESCRIPTION OF THE OPERATION MODES
The operation modes described in this paragraph constitute a functionality of the sample under test for itself.
Every operation mode takes failure criteria for the immunity test that they were applying to it and a monitoring
to guarantee performance of the same ones.
The operation modes used by the samples to which the present report refers, are shown in the following table:


          OPERATION                                      DESCRIPTION
            MODE
                            EUT ON. Idle mode (No cellular Tx) w/ GPS Rx ON. Powered by 12Vdc, Both
              OM#01*
                            Polarizations
         *Worst configurations detected




Report No: 2528ERM.002                              Page 11 of 15                                          2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




A.1.RADIATED EMISSION. ELECTROMAGNETIC FIELD TEST
                                                           FCC CFR 47, Part 15, Subpart B (10-1-18 Edition), Secs. 15.109
                            Product standard:
                                                           & ICES-003 Issue 6 – Update April (2017)
    LIMITS:
                                                           FCC CFR 47, Part 15, Subpart B (10-1-18 Edition), Secs. 15.109
                               Test standard:
                                                           & ICES-003 Issue 6 – Update April (2017); ANSI C63.4 (2014)

Limits of interference Class B
The applied limit for radiated emissions, 3 m distance, according with the requirements of FCC Rules and
Regulations 47 CFR Part 15, Subpart B (10-01-18 Edition), Secs. 15.109 & ICES-003 Issue 6 – Update April
(2017) in the frequency range 30 MHz to 40 GHz for class B equipment.

                                                Frequency range                       QP Limit for 3 m
                                                     (MHz)                         (V/m)        (dBV/m)
                                                    30 to 88                         100            40
                                                   88 to 216                         150           43.5
                                                   216 to 960                        200            46
                                                   Above 960                         500            54

                                    Frequency range               AVG Limit for 3 m              PK Limit for 3 m (1)
                                         (MHz)                  (V/m)     (dBV/m)                  (dBV/m)
                                      Above 1000                  500          54                        74
                            Frequencies above 1 GHz, the limit on peak radio frequency emissions is 20 dB above the maximum permitted
                            average emission limit applicable to the equipment under test, as per §15.35(b




                TEST SETUP


All radiated tests were performed in a semi-anechoic chamber. The measurement antenna is situated at a
distance of 3 m for the frequency range 30-1000 MHz (Bilog antenna) and at a distance of 1m for the frequency
range 1-40 GHz (1 GHz-18 GHz and 18 GHz-40 GHz Double ridge horn antennas).
For radiated emissions in the range 1-40 GHz that is performed at a distance closer than the specified distance,
an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for determining
compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation
and orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna
height was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyzer.
This correction factor includes antenna factor, cable loss and pre-amplifiers gain.




Report No: 2528ERM.002                                                  Page 12 of 15                                                   2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




          TEST SETUP (Cont.)




           TESTED SAMPLES:                                                   S/01
   TESTED OPERATION MODES:                                               OM#01
                                          CRmmnnxx: CR, Radiation Condition; mm: Sample number; nn:
             TEST RESULTS:
                                          Operation mode.,xx:Range,




            CRmmnnxx                             Description                              Result
           CR0101LR         Range: 30 MHz - 1000 MHz Horizontal Polarization                P

           CR0101LR         Range: 30 MHz - 1000 MHz Vertical Polarization                  P

           CR0101HR1        Range: 1-18 GHz Horizontal Polarization                         P

           CR0101HR1        Range: 1-18 GHz Vertical Polarization                           P




Report No: 2528ERM.002                               Page 13 of 15                                    2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America




Radiated Emission. CR0101LR


  Project:                                         02528ERM002
  Company:                                         Telit
  Sample:                                          S/01
  Operation mode:                                  OM#01
  Description:                                     EUT ON. IDLE. Powered by 12Vdc. Both polarizations.
                            Level in dBµV/m




                                                              Final_Result

                                              Frequency      MaxPeak     QuasiPeak    Pol   Azimuth
                                                (MHz)        (dBµV/m)    (dBµV/m)            (deg)
                                                 95.329500        18.4          5.6   V          2.0
                                                104.835500        19.0          6.1   V        -42.0
                                                177.634000        21.3          8.8   H       -129.0
                                                256.980000        23.9         11.9   H        132.0
                                                383.565000        29.0         16.3   H         87.0
                                                543.615000        34.9         21.7   V       -180.0




Report No: 2528ERM.002                                            Page 14 of 15                          2019-05-01


DEKRA Certification, Inc.
405 Glenn Dr. Suite 12,
Sterling, VA 20164
United States of America


Radiated Emission. CR0101HR1



  Project:                     02528ERM002
  Company:                     Telit
  Sample:                      S/01
  Operation mode:              OM#01
  Description:                 EUT ON. IDLE. Powered by 12Vdc. Both polarizations.




                                             Final_Result
                            Frequency       PK+_MAXH     AVG_MAXH      Pol   Azimuth
                               (MHz)         (dBµV/m)     (dBµV/m)            (deg)
                              1559.406250        29.28         20.57   V       -180.0
                              1799.531250        30.58         21.87   V       -180.0
                              8436.968750        35.52         27.61   V       -180.0
                             13165.093750        37.68         28.28   V        180.0




Report No: 2528ERM.002                           Page 15 of 15                          2019-05-01



Document Created: 2019-05-29 18:04:47
Document Modified: 2019-05-29 18:04:47

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC