RF-Exposure

FCC ID: RI7LM960

RF Exposure Info

Download: PDF
FCCID_4165436

DEKRA Testing and Certification, Inc
405 Glenn Drive Suite #12
Sterling | Virginia 20164 | United States of America




              Environmental evaluation and exposure limit according to FCC CFR 47part 1,
                                           §1.1307, §1.1310



The calculation was done to confirm required safe distance for the end user device.

Limit for power density for general population/uncontrolled exposure is 1 mW/cm 2 for 1500 -100000 MHz
frequency range:

                                            2            2
The power density P (mW/cm ) = PT / 4π r , where PT is the maximum equivalent isotropically radiated power


(EIRP).

1) The selected power is the max allowed power level as per FCC for an end user device. The EIRP


calculation will include the total antenna gain. Please refer to “§96.41 General radio requirements” corresponds to

the equivalent isotropically radiated power (EIRP) for an end user device

                                                  FCC MAX EIRP 23 dBm, is equal to 199.5 mW

The minimum safe distance “r”, where RF exposure does not exceed FCC permissible limit, is

                                             r = sqrt { PT / (Px4π)} = sqrt {199.5 / 12.56} = 3.98 cm.


General public cannot be exposed to dangerous RF level, the user manual instructs the end user device is located
at least 20 cm from all persons.




Report No: RF Exposure Report                                                                            2018-12-17



Document Created: 2018-12-17 16:53:31
Document Modified: 2018-12-17 16:53:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC