RF Exposure_LE910C1-ST

FCC ID: RI7LE910C1ST

RF Exposure Info

Download: PDF
FCCID_4214588

DEKRA Testing and Certification S.A.U.TCB
Parque Tecnológico de Andalucía
Severo Ochoa, 2 & 6
29590 Málaga
Spain

Date: December 19th, 2018
Report: 58506_LE910C1-ST

                  RF exposure analysis for the equipment – Maximum Antenna Gain

Model: LE910C1-ST                      FCC ID: RI7LE910C1ST                                IC: 5131A-LE910C1ST

The device Telit LE910C1-ST is a module designed to be installed in other devices. This device is to be used
only for fixed and mobile applications. If the final product after integration is intended for portable use, new
applications and FCC and IC are required.

The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm
from all the persons and must not be co-located or operating in conjunction with any other antenna or
transmitter except as under the conditions described KDB 447498 D01 General RF Exposure Guidance.


MPE exposure limits

The table below is excerpted from Table 1B of 47 CFR 1.1310 titled Limits for Maximum Permissible Exposure
(MPE), Limits for General Population/Uncontrolled Exposure:

          Frequency Range (MHz)                     Power density (mW/cm2)                    Averaging time (minutes)
                   300 – 1500                               f (MHz) /1500                                        30
                 1500 – 100.000                                    1,0                                           30

The table below is excerpted from RSS-102, Issue 5, 4, titled “Table 4: RF Field Strength Limits for Devices
Used by the General Public”:

          Frequency Range (MHz)                       Power density (W/m2)                    Averaging time (minutes)
                   300 – 6000                               0.02619·f 0.6834                                     6


EIRP limits

                                         Maximum
                       Frequency         conducted
                                                           FCC MPE           IC MPE           FCC/IC             FCC EIRP    IC EIRP
                          (MHz)            output
      Band                                                   limit             limit         MPE limit             limit       limit
                         (Lowest         power (per
                                                           (mW/cm2)         (mW/cm2)         (mW/cm2)               (W)         (W)
                       Frequency)         tune-up)
                                           (dBm)
     FDD 71               663,0             25,00             0,442               -           0,44200                 4,92      -
     FDD 12               699,0             25,00             0,466            0,230          0,23017                 4,92    5,00
      FDD 4              1710,0             25,00             1,000            0,424          0,42419                 1,00    1,00
     FDD 66              1710,0             25,00             1,000            0,424          0,42419                 1,00    1,00
      FDD 2              1850,0             25,00             1,000            0,448          0,44763                 2,00    2,00


                               PG
Using the equation     S              to calculate the exposure to electromagnetic fields
                             4R 2
        where:    S = power density (in appropriate units, e.g. mW/cm 2)
                  P = power input to the antenna (in appropriate units, e.g., mW)
                  G = power gain of the antenna in the direction of interest relative to an isotropic radiator
                  R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


The maximum antenna gain that can be used in the LE910C1-ST is shown in the following table:

                               Maximum                                                                                       Evaluation                                                      Maximun        Maximun antenna
                Frequency                                                                                                                 Antenna gain to Antenna gain to Antenna gain to
                              conducted                  FCC MPE                  FCC/IC MPE                                distance for                                                  antenna gain to gain to meet all the
                   (MHz)                   Duty cicle              IC MPE limit              FCC EIRP limit IC EIRP limit                  meet FCC/IC meet FCC EIRP meet IC EIRP
       Band                  output power                  limit              2      limit                                compliance with                                                   meet all the  limits per frequency
                 (Low est                     (%)                  (mW/cm )                       (W)            (W)                         MPE  limit        limit           limit
                             (per tune-up)              (mW/cm2)                   (mW/cm2)                                  MPE limits                                                       limits              band
                Frequency)                                                                                                                     (dBi)           (dBi)           (dBi)
                                (dBm)                                                                                           (cm)                                                           (dBi)              (dBi)

   FDD 71         663,0         25,00       100,0%       0,442          -          0,44200         4,92            -             20             8,46            11,91            -             8,46
                                                                                                                                                                                                                  5,63
   FDD 12         699,0         25,00       100,0%       0,466        0,230        0,23017         4,92          5,00            20             5,63            11,91          11,98           5,63
       FDD 4     1710,0         25,00       100,0%       1,000        0,424        0,42419         1,00          1,00            20             8,28            5,00            5,00           5,00
                                                                                                                                                                                                                  5,00
   FDD 66        1710,0         25,00       100,0%       1,000        0,424        0,42419         1,00          1,00            20             8,28            5,00            5,00           5,00
       FDD 2     1850,0         25,00       100,0%       1,000        0,448        0,44763         2,00          2,00            20             8,52            8,01            8,01           8,01               8,01




And according to these maximum antenna gains calculated, the spectral power density for each band is
shown in the table below:

                                 Maximum                                                                                                                            Evaluation
                    Frequency
                                conducted                               Antenna        FCC/IC MPE                                                    FCC/IC        distance for                 PG
        Band
                       (MHz)
                               output power
                                             Duty cicle
                                                                          gain            limit
                                                                                                  FCC EIRP limit              IC EIRP limit
                                                                                                                                                   EIRP limit      compliance
                                                                                                                                                                                       S                     MPE Ratio
                     (Low est
                               (per tune-up)
                                                (%)
                                                                         (dBi)          (mW/cm 2)
                                                                                                       (W)                         (W)
                                                                                                                                                      (W)            with MPE                  4R 2         (S/MPE limit)
                    Frequency)
                                  (dBm)                                                                                                                             limits (cm)
       FDD 71         663,0               25,00           100,0%            5,63          0,44200             4,92                   -                 4,92               20               0,23000              0,52036
       FDD 12         699,0               25,00           100,0%            5,63          0,23017             4,92                 5,00                4,92               20               0,23000              0,99926
        FDD 4         1710,0              25,00           100,0%            5,00          0,42419             1,00                 1,00                1,00               20               0,19894              0,46899
       FDD 66         1710,0              25,00           100,0%            5,00          0,42419             1,00                 1,00                1,00               20               0,19894              0,46899
        FDD 2         1850,0              25,00           100,0%            8,01          0,44763             2,00                 2,00                2,00               20               0,39786              0,88881


According to the tables above, the maximum gain allowed to be compliant to the Normative Document is 5.63
dBi for the 600 MHz band, 5.00 dBi for 1700 MHz band and 8.01 dBi for the 1800 MHz band, based on a 20
cm distance between antenna and human body.

Yours sincerely,
P.A.




_______________________________
By:     Ken Bednasz
Title: VP Application Engineer
Company: Telit Communications S.p.A.
Telephone: 1-919-415-1517
e-mail: Ken.Bednasz@telit.com



Document Created: 2018-12-28 13:58:46
Document Modified: 2018-12-28 13:58:46

© 2024 FCC.report