14a_DISTO S910 TestRep 15Brev

FCC ID: RFF-LD5PS

Test Report

Download: PDF
FCCID_2563065

                                                         EMC TEST REPORT
                                                          FCC 47 CFR Part 15B
                                                        Industry Canada RSS-Gen
                                  Electromagnetic compatibility - Unintentional radiators

Report Reference No. .................... : G0M-1407-4002-EF0115B-V01

Testing Laboratory ........................ : Eurofins Product Service GmbH

Address ............................................ : Storkower Str. 38c
                                                       15526 Reichenwalde
                                                       Germany

Accreditation .................................... :




                                                       A2LA Accredited Testing Laboratory, Certificate No.: 1983.01
                                                       FCC Filed Test Laboratory, Reg.-No.: 96970
                                                       IC OATS Filing assigned code: 3470A

Applicant’s name ........................... : Leica Geosystems AG

Address ............................................ : Heinrich Wild Strasse
                                                       9435 Heerbrugg
                                                       SWITZERLAND

Test specification:

Standard ........................................... : 47 CFR Part 15 Subpart B
                                                       RSS-Gen, Issue 3, 2010-12
                                                       ANSI C63.4:2009

Equipment under test (EUT):

Product description                                    Laser Distance Meter

Model No.                                              Leica DISTO S910

Additional Models                                      None

Hardware version                                       V15

Firmware / Software version                            2332

Contains                                               FCC-ID: RFF-LD5PS                     IC: 3177A-LD5PS

Test result                                            Passed




                                         Test Report No.: G0M-1407-4002-EF0115B-V01
                                                       Eurofins Product Service GmbH
                                         Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                               Page 1 of 27


   <= eurofins
                                         Product Service



Possible test case verdicts:

— not applicable to test object...                                N/A

— test object does meet the requirement.......................:   P (Pass)

— test object does not meet the requirement.................:     F (Fail)

Testing:

Dat@ Of r@C@IPt Of t@St It@M ..............cscsceemeeeee?         2014—08—04

Date (s) of performance Of tests .......................          2014—08—04 — 2014—10—17

COMPiI@U DY .......cccceeeemmereeen es :        Steffen Zunke

Tested by (+ signature).................... :   Steffen Zunke                          ...C?A .................

Approved by (+ signature) ............... :     Marcus Klein                           Wé—....................

DAIG OFIBSL® :s smm cmmmmmeenermmmeress :0      2014—10—27

Total number of pages ..................... n   27

General remarks:

The test results presented in this report relate only to the object tested.
The results contained in this report reflect the results for this particular model and serial number. It
is the responsibility of the manufacturer to ensure that all production models meet the intent of the
requirements detailed within this report.

This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.

Additional comments:




                                   Test Report No.: GOM—1407—4002—EF0115B—V01
                                                Eurofins Product Service GmbH
                                   Storkower Str. 38c, D—15526 Reichenwalde, Germany
                                                                                                    Page 2 of 27


Version History
Version   Issue Date      Remarks                                          Revised by
V01       2014-10-27      Initial Release




                       Test Report No.: G0M-1407-4002-EF0115B-V01
                                     Eurofins Product Service GmbH
                       Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                            Page 3 of 27


REPORT INDEX




1     EQUIPMENT (TEST ITEM) DESCRIPTION                                                   5

1.1   Photos – Equipment external                                                         7
1.2   Photos – Equipment internal                                                         8
1.3   Photos – Test setup                                                                12
1.4   Supporting Equipment Used During Testing                                           13
1.5   Operating Modes                                                                    14
1.6   Test Equipment Used During Testing                                                 15
1.7   Sample emission level calculation                                                  16

2     RESULT SUMMARY                                                                     17

3     TEST CONDITIONS AND RESULTS                                                        18

3.1   Test Conditions and Results – Radiated emissions                                   18
3.2   Test Conditions and Results – AC power line conducted emissions                    25




                            Test Report No.: G0M-1407-4002-EF0115B-V01
                                          Eurofins Product Service GmbH
                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                Page 4 of 27


1   Equipment (Test item) Description

Description                       Laser Distance Meter

Model                             Leica DISTO S910

Additional Models                 2332

Serial number                     None

Hardware version                  V15

Software / Firmware version       2332

Contains FCC-ID                   RFF-LD5PS

Contains IC                       3177A-LD5PS

Power supply                      3.6VDC via rechargeable Battery

                                  Model : KS044067
                                  Manufacturer : Ktec
AC/DC-Adaptor
                                  Input : 100-240VAC / 50-60Hz
                                  Output : 5VDC / 1.0A
                                  Type                     WLAN Module
                                  Model                    WF121-A
                                  Manufacturer             Blue Giga
Radio module                      HW Version               4
                                  SW Version               1.2.3-69
                                  FCC-ID                   QOQ-WF121
                                  IC                       5123A-BGTWF121
                                  Type                     Bluetooth Module
                                  Model                    nRF8001
                                  Manufacturer             Nordic Semiconductor
Radio module                      HW Version               1.4
                                  SW Version               1.2
                                  FCC-ID                   -
                                  IC                       -




                        Test Report No.: G0M-1407-4002-EF0115B-V01
                                      Eurofins Product Service GmbH
                        Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                  Page 5 of 27


                                  Flextronics International GmbH
                                  Friesacher Strasse 3
Manufacturer
                                  9330 Althofen
                                  AUSTRIA

Highest emission frequency        Fmax [MHz] = 2.49GHz

Device classification             Class B

Equipment type                    Tabletop

Number of tested samples          1




                        Test Report No.: G0M-1407-4002-EF0115B-V01
                                      Eurofins Product Service GmbH
                        Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                            Page 6 of 27


  1.4       Supporting Equipment Used During Testing


Product
                      Device                      Manufacturer             Model No.     Comments
 Type*
   AE                   IPad                         Apple                       -           -

   AE              Power Supply                       Ktec                 KS044067          -

*Note: Use the following abbreviations:
        AE : Auxiliary/Associated Equipment, or

        SIM : Simulator (Not Subjected to Test)

    CABL : Connecting cables




                                     Test Report No.: G0M-1407-4002-EF0115B-V01
                                                   Eurofins Product Service GmbH
                                     Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                           Page 13 of 27


 1.5     Operating Modes


Mode #                                               Description
          Measure mode with WLAN link to an IPad and charging
  1




                           Test Report No.: G0M-1407-4002-EF0115B-V01
                                         Eurofins Product Service GmbH
                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                               Page 14 of 27


 1.6    Test Equipment Used During Testing


                                        Measurement Software
       Description               Manufacturer                          Name                    Version
  EMC Test Software            Dare Instruments                     Radimation                2014.1.15


                                          Radiated emissions
   Description       Manufacturer          Model               Identifier        Cal. Date       Cal. Due
Biconical Antenna       R&S               HK 116               EF00012           2013-02          2016-02
  LPD-Antenne           R&S               HL 223               EF00187           2014-03         2017-03
  LPD-Antenna           R&S               HL 025               EF00327           2013-02         2016-02
EMI Test Receiver       R&S               ESU26                EF00887           2014-01         2015-01

                                         Conducted emissions
   Description       Manufacturer          Model               Identifier        Cal. Date       Cal. Due
       AMN              R&S              ESH2-Z5               EF00182           2012-10         2014-10
       AMN              R&S              ESH3-Z5               EF00036           2012-11         2014-11
EMI Test Receiver       R&S              ESCS 30               EF00295           2013-10         2014-10




                           Test Report No.: G0M-1407-4002-EF0115B-V01
                                         Eurofins Product Service GmbH
                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                             Page 15 of 27


1.7      Sample emission level calculation

The following is a description of terms and a sample calculation, as appears in the radiated emissions
data table. The numbers used in the calculation are for example only. There is no direct correlation to
the specific data taken for the product described in this document:

Reading:

This is the reading obtained on the spectrum analyzer in dBµV. Any external preamplifiers used are
taken into account through internal analyzer settings.

A.F.:

This is the antenna factor for the receiving antenna. It is a conversion factor, which converts electric
fields strengths to voltages, which can be measured directly on the spectrum analyzer. It is treated as
a loss in dB. Cable losses have been included with the A.F. to simplify the calculations. The antenna
factor is used in calculations as follows:

                 Reading on Analyzer (dBµV) + A.F. (dB) = Net field strength (dBµV/m)

Net:

This is the net field strength measurement (as shown above).

Limit:

This is the FCC Class B radiated emission limit (in units of dBµV/m). The FCC limits are given in units
of µV/m. The following formula is used to convert the units of µV/m to dBµV/m:

                                    Limit (dBµV/m) = 20*log (µV/m)

Margin:

This is the margin of compliance below the FCC limit. The units are given in dB. A negative margin
indicates the emission was below the limit. A positive margin indicates that the emission exceeds the
limit.

Example only:

          Reading + AF      =       Net Reading       :    Net reading - FCC limit = Margin
          21.5 dBµV + 26 dB =       47.5 dBµV/m       :    47.5 dBµV/m - 57.0 dBµV/m = -9.5 dB




                           Test Report No.: G0M-1407-4002-EF0115B-V01
                                         Eurofins Product Service GmbH
                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                          Page 16 of 27


  2    Result Summary


                             FCC 47 CFR Part 15B, Industry Canada RSS-Gen

 Product Specific                                                    Reference
                                  Requirement – Test                               Result          Remarks
    Standard                                                          Method
                                                                                             For measurement results
                                                                                             above 5GHz see relevant
   47 CFR 15.109
                      Radiated emissions                             ANSI C 63.4   PASS       radio technology report
 RSS-Gen 4.9 & 4.10
                                                                                            G0M-1407-4002-TFC247BL
                                                                                                      / WF.pdf
   47 CFR 15.107
                      AC power line conducted emissions              ANSI C63.4    PASS                 -
   RSS-Gen 7.2.4
Remarks:




                               Test Report No.: G0M-1407-4002-EF0115B-V01
                                             Eurofins Product Service GmbH
                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                  Page 17 of 27


  3      Test Conditions and Results

  3.1     Test Conditions and Results – Radiated emissions


Radiated emissions acc. FCC 47 CFR 15.109 / IC RSS-Gen                                                 Verdict: PASS
          Laboratory Parameters:                  Required prior to the test                    During the test
           Ambient Temperature                            15 to 35 °C                               25°C
             Relative Humidity                            30 to 60 %                                 48%

         Test according referenced                                         Reference Method
                 standards                                                   ANSI C63.4

  Sample is tested with respect to the                                     Equipment class
 requirements of the equipment class                                           Class B

Test frequency range determined from                               Highest emission frequency
      highest emission frequency                                     Fmax [MHz] = 2.49GHz

 Fully configured sample scanned over                                      Frequency range
      the following frequency range                                        30 MHz to 6 GHz
             Operating mode                                                          1
                                            Limits and results Class B
Frequency [MHz]       Quasi-Peak [dBµV/m] Result            Average [dBµV/m]             Result Peak [dBµV/m] Result
        30 – 88                   40              PASS                 -                               -           -
      88 – 216                   43.5             PASS                 -                               -           -
      216 – 960                   46              PASS                 -                               -           -
   960 – 1000                     54              PASS                 -                               -           -
        > 1000                     -                 -               54                  PASS         74          PASS
Comments:
Bluetooth mode was considered, but no relevant different disturbances were determined.




                                 Test Report No.: G0M-1407-4002-EF0115B-V01
                                               Eurofins Product Service GmbH
                                 Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                       Page 18 of 27


  Spurious emissions under normal conditions according to FCC 15B

  Project number: G0M-1407-4002

  Manufacturer:                                                   Leica Geosystems AG
  EUT Name:                                                       Laser Distance Meter
  Model:                                                          Leica DISTO S910
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 25°C, Unom: 3.6VDC via AC/DC Adapter
  Antenna:                                                        Rohde & Schwarz HK 116, Vertical
  Measurement distance:                                           3m, converted to 10m
  Mode:                                                           measure mode, charging, WLAN active
  Test Date:                                                      2014-09-09
  Note:
                                                                                                                                             Index 21

                                    FCC part 15B Class B QP        RBW: 120 kHz, Vertical Max Peak



                            60




                            50




                            40
Electrical Field (dBµV/m)




                            30




                            20




                            10




                            0




                             30 M              40 M                       60 M                  80 M     100 M    120 M   140 M   160 M     200 M

                                                                                        Frequency (Hz)




                                                              Test Report No.: G0M-1407-4002-EF0115B-V01
                                                                            Eurofins Product Service GmbH
                                                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                     Page 19 of 27


  Spurious emissions under normal conditions according to FCC 15B

  Project number: G0M-1407-4002

  Manufacturer:                                                   Leica Geosystems AG
  EUT Name:                                                       Laser Distance Meter
  Model:                                                          Leica DISTO S910
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Mr. Zunke
  Test Conditions:                                                Tnom: 25°C, Unom: 3.6VDC via AC/DC Adapter
  Antenna:                                                        Rohde & Schwarz HK 116, Horizontal
  Measurement distance:                                           3m, converted to 10m
  Mode:                                                           measure mode, charging, WLAN active
  Test Date:                                                      2014-09-09
  Note:
                                                                                                                                             Index 20

                                    FCC part 15B Class B QP        RBW: 120 kHz, Horizontal Max Peak



                            60




                            50




                            40
Electrical Field (dBµV/m)




                            30




                            20




                            10




                            0




                             30 M              40 M                       60 M                 80 M      100 M    120 M   140 M   160 M     200 M

                                                                                        Frequency (Hz)




                                                              Test Report No.: G0M-1407-4002-EF0115B-V01
                                                                            Eurofins Product Service GmbH
                                                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                     Page 20 of 27


  Spurious emissions under normal conditions according to FCC 15B

  Project number: G0M-1407-4002

  Manufacturer:                                                       Leica Geosystems AG
  EUT Name:                                                           Laser Distance Meter
  Model:                                                              Leica DISTO S910
  Test Site:                                                          Eurofins Product Service GmbH
  Operator:                                                           Mr. Zunke
  Test Conditions:                                                    Tnom: 25°C, Unom: 3.6VDC via AC/DC Adapter
  Antenna:                                                            Rohde & Schwarz HL 223, Vertical
  Measurement distance:                                               3m, converted to 10m
  Mode:                                                               measure mode, charging, WLAN active
  Test Date:                                                          2014-09-09
  Note:
                                                                                                                                                    Index 23

                                    FCC part 15B Class B QP           RBW: 120 kHz, Vertical Max Peak
                            65


                            60


                            55


                            50


                            45
Electrical Field (dBµV/m)




                            40


                            35


                            30


                            25


                            20


                            15


                            10


                            5
                            200 M                             300 M                   400 M                 500 M   600 M   700 M   800 M           1G

                                                                                           Frequency (Hz)




                                                               Test Report No.: G0M-1407-4002-EF0115B-V01
                                                                             Eurofins Product Service GmbH
                                                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                            Page 21 of 27


  Spurious emissions under normal conditions according to FCC 15B

  Project number: G0M-1407-4002

  Manufacturer:                                                       Leica Geosystems AG
  EUT Name:                                                           Laser Distance Meter
  Model:                                                              Leica DISTO S910
  Test Site:                                                          Eurofins Product Service GmbH
  Operator:                                                           Mr. Zunke
  Test Conditions:                                                    Tnom: 25°C, Unom: 3.6VDC via AC/DC Adapter
  Antenna:                                                            Rohde & Schwarz HL 223, Horizontal
  Measurement distance:                                               3m, converted to 10m
  Mode:                                                               measure mode, charging, WLAN active
  Test Date:                                                          2014-09-09
  Note:
                                                                                                                                                             Index 25

                                    FCC part 15B Class B QP           RBW: 120 kHz, Horizontal Max Peak
                            65


                            60


                            55


                            50

                                                                                        1
                            45
Electrical Field (dBµV/m)




                            40


                            35


                            30


                            25


                            20


                            15


                            10


                            5
                            200 M                             300 M                   400 M                  500 M        600 M     700 M    800 M           1G

                                                                                            Frequency (Hz)

  Frequency                                          Quasi-Peak                     Quasi-Peak Limit                 Quasi-Peak Difference   Quasi-Peak Status
  398,995 MHz                                        41,17 dBµV/m                   46 dBµV/m                        -4,83 dB                Pass




                                                               Test Report No.: G0M-1407-4002-EF0115B-V01
                                                                             Eurofins Product Service GmbH
                                                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                     Page 22 of 27


  Spurious emissions under normal conditions according to FCC 15B

  Project number: G0M-1407-4002

  Manufacturer:                                                     Leica Geosystems AG
  EUT Name:                                                         Laser Distance Meter
  Model:                                                            Leica DISTO S910
  Test Site:                                                        Eurofins Product Service GmbH
  Operator:                                                         Mr. Zunke
  Test Conditions:                                                  Tnom: 25°C, Unom: 3.6VDC via AC/DC Adapter
  Antenna:                                                          Rohde & Schwarz HL 025, Vertical
  Measurement distance:                                             3m, converted to 10m
  Mode:                                                             measure mode, charging, WLAN active
  Test Date:                                                        2014-09-09
  Note:
                                                                                                                                                            Index 32

                                   FCC part 15B Class B AV           FCC part 15B Class B Peak            RBW: 1 MHz, Vertical Max Average
                                   RBW: 1 MHz, Vertical Max Peak



                            100

                                                                                                           1
                            90


                            80


                            70
Electrical Field (dBµV/m)




                            60


                            50


                            40


                            30


                            20


                            10



                              1G                            1,5 G                     2G                  2,5 G            3G          3,5 G   4G           5G

                                                                                         Frequency (Hz)

  Frequency
  2,467 GHz WLAN carrier




                                                            Test Report No.: G0M-1407-4002-EF0115B-V01
                                                                          Eurofins Product Service GmbH
                                                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                    Page 23 of 27


  Spurious emissions under normal conditions according to FCC 15B

  Project number: G0M-1407-4002

  Manufacturer:                                                    Leica Geosystems AG
  EUT Name:                                                        Laser Distance Meter
  Model:                                                           Leica DISTO S910
  Test Site:                                                       Eurofins Product Service GmbH
  Operator:                                                        Mr. Zunke
  Test Conditions:                                                 Tnom: 25°C, Unom: 3.6VDC via AC/DC Adapter
  Antenna:                                                         Rohde & Schwarz HL 025, Horizontal
  Measurement distance:                                            3m, converted to 10m
  Mode:                                                            measure mode, charging, WLAN active
  Test Date:                                                       2014-09-09
  Note:
                                                                                                                                                          Index 33

                                   FCC part 15B Class B AV         FCC part 15B Class B Peak            RBW: 1 MHz, Horizontal Max Average
                                   RBW: 1 MHz, Horizontal Max Peak



                            100

                                                                                                        1
                            90


                            80


                            70
Electrical Field (dBµV/m)




                            60


                            50


                            40


                            30


                            20


                            10



                              1G                           1,5 G                     2G                 2,5 G           3G           3,5 G   4G           5G

                                                                                       Frequency (Hz)

  Frequency
  2,425 GHz WLAN carrier




                                                           Test Report No.: G0M-1407-4002-EF0115B-V01
                                                                         Eurofins Product Service GmbH
                                                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                  Page 24 of 27


  3.2     Test Conditions and Results – AC power line conducted emissions


Conducted emissions acc. FCC 47 CFR 15.107 / IC RSS-Gen                                                  Verdict: PASS
         Laboratory Parameters:                     Required prior to the test                     During the test
          Ambient Temperature                               15 to 35 °C                                25°C
            Relative Humidity                               30 to 60 %                                  48%

        Test according referenced                                          Reference Method
                standards                                                      ANSI C63.4

 Fully configured sample scanned over                                       Frequency range
      the following frequency range                                        0.15 MHz to 30 MHz

   Sample is tested with respect to the                                     Equipment class
  requirements of the equipment class                                            Class B
           Points of Application                                           Application Interface
                 AC Mains                                                         LISN
             Operating mode                                                          1
                                              Limits and results Class B
   Frequency [MHz]             Quasi-Peak [dBµV]                  Result         Average [dBµV]               Result
        0.15 to 5                    66 to 56*                    PASS               56 to 46*                PASS
         0.5 to 5                        56                       PASS                   46                   PASS
         5 to 30                         60                       PASS                   50                   PASS
Comments:
* Limit decreases linearly with the logarithm of the frequency.




                                 Test Report No.: G0M-1407-4002-EF0115B-V01
                                               Eurofins Product Service GmbH
                                 Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                         Page 25 of 27


 EMI voltage test in the ac-mains according to FCC 15B

 Project number: G0M-1407-4002

 Manufacturer:                                        Leica Geosystems AG
 EUT Name:                                            Laser Distance Meter
 Model:                                               Leica DISTO S910
 Test Site:                                           Eurofins Product Service GmbH
 Operator:                                            Mr. Zunke
 Test Conditions:                                     Tnom: 25°C, Unom: 120 VAC
 LISN:                                                ESH2-Z5 N
 Mode:                                                measure mode, charging, WLAN link
 Test Date:                                           2014-09-09
 Note:
                                                                                                                                     Index 15

                          FCC 15B AV     FCC 15B QP         RBW: 9 kHz, Neutral Max Average   RBW: 9 kHz, Neutral Max Peak



                 80


                 70


                 60


                 50
Voltage (dBµV)




                 40


                 30


                 20


                 10


                  0


                 -10




                  150 k          300 k   500 k600 k        1M               2M          3M    5M             10 M             20 M   30 M

                                                                       Frequency (Hz)




                                            Test Report No.: G0M-1407-4002-EF0115B-V01
                                                          Eurofins Product Service GmbH
                                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                             Page 26 of 27


 EMI voltage test in the ac-mains according to FCC 15B

 Project number: G0M-1407-4002

 Manufacturer:                                        Leica Geosystems AG
 EUT Name:                                            Laser Distance Meter
 Model:                                               Leica DISTO S910
 Test Site:                                           Eurofins Product Service GmbH
 Operator:                                            Mr. Zunke
 Test Conditions:                                     Tnom: 25°C, Unom: 120 VAC
 LISN:                                                ESH2-Z5 L
 Mode:                                                measure mode, charging, WLAN link
 Test Date:                                           2014-09-09
 Note:
                                                                                                                                   Index 16

                          FCC 15B AV     FCC 15B QP         RBW: 9 kHz, Line 1 Max Average   RBW: 9 kHz, Line 1 Max Peak



                 80


                 70


                 60


                 50
Voltage (dBµV)




                 40


                 30


                 20


                 10


                  0


                 -10




                  150 k          300 k   500 k600 k        1M               2M          3M   5M               10 M          20 M   30 M

                                                                       Frequency (Hz)




                                            Test Report No.: G0M-1407-4002-EF0115B-V01
                                                          Eurofins Product Service GmbH
                                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                           Page 27 of 27



Document Created: 2015-03-20 09:04:53
Document Modified: 2015-03-20 09:04:53

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC