18_Leica DISTO Sigma3 RFExp

FCC ID: RFF-LD1BT

RF Exposure Info

Download: PDF
FCCID_2884222

                                     RF-EXPOSURE ASSESSMENT REPORT
                                                          FCC 47 CFR Part 2.1093
                                                         Industry Canada RSS-102
                                      RF-Exposure evaluation of portable equipment

Report Reference No. ..................... :              G0M-1508-4977-TFC093PE-V02

Testing Laboratory ......................... :            Eurofins Product Service GmbH

Address............................................. :    Storkower Str. 38c
                                                          15526 Reichenwalde
                                                          Germany

Accreditation ..................................... :




                                                          A2LA Accredited Testing Laboratory, Certificate No.: 1983.01
                                                          FCC Filed Test Laboratory, Reg.-No.: 96970
                                                          IC OATS Filing assigned code: 3470A

Applicant’s name ............................ :           Leica Geosystems AG
Address............................................. :    Heinrich Wild Strasse
                                                          9435 Heerbrugg
                                                          SWITZERLAND
Test specification:
Standard ........................................... :    47 CFR 1.1310 / 47 CFR 2.1091 / 47 CFR 2.1093
                                                          OET Bulletin 65:1997
                                                          KDB 447498 D01 v05r02:2014-02-07
                                                          RSS-102, Issue 5:2015-03
                                                          Safety Code 6:2015-03
Equipment under test (EUT):
Product description                                       Laser Distance Meter
Model No.                                                 Leica DISTO Sigma3
Additional Model(s)                                       LD 250 BT
Brand Name(s)                                             Leica DISTO
Hardware version                                          V04
Firmware / Software version                               0309
                                                          FCC-ID: RFF-LD1BT                IC: 3177A-LD1BT
Test result                                               Passed




                                     Test Report No.: G0M-1508-4977-TFC093PE-V02
                                                     Eurofins Product Service GmbH
                                       Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                             Page 1 of 12


«* eurofins ‘
                                   | Product Service



Possible test case verdicts:

— neither @ssesSed NOF t@§ted ..............scscceeeeeee l           N/N

— required by standard but not appl. to test object........:         N/A
— required by standard but not tested..............c.c.c.c..ll       NT
— not required by standard for the test object ..                    NR

— test object does meet the requirement....                          P (Pass)

— test object does not meet the requirement.................:        F (Fail)
Testing:

Date Of r@C@Ipt Of t@St It@M .............c..scsceeenl              2015—08—18

Dat® ($) Of @SS@SSM@Nt.............scccmeeeemeeeeel.                2016—11—10

COMDIBA BY .mm mm rcmmmensmmmene :               Christian Weber

Assessed by (+ signature) ............... ;
(Responsible for Assessment)                     Christian Weber                    ...z Imammufe oummnnmenie


Approved by (+ signature) ............... :      Toralf Jahn

DBI8 Of IBEU80 :: mmummmmpmemmmenmen :0          2015—11—10

Total number of pages ..................... 5    2

General remarks:

The test results presented in this report relate only to the object tested.
The results contained in this report reflect the results for this particular model and serial
number. It is the responsibility of the manufacturer to ensure that all production models meet
the intent of the requirements detailed within this report.

This report shall not be reproduced, exceptin full, without the written approval of the Issuing testing
laboratory.

Additional comments:




                               Test Report No.: GOM—1508—4977—TFCO93PE—VO2
                                                Eurofins Product Service GmbH
                                Storkower Str. 38c, D—15526 Reichenwalde, Germany
                                                                                                  Page 2 of 12


Version History
 Version   Issue Date       Remarks                                         Revised by
 01        2015-10-13       Initial Release

 02        2015-11-10       Reference documents updated                     C. Weber




                    Test Report No.: G0M-1508-4977-TFC093PE-V02
                                      Eurofins Product Service GmbH
                        Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                               Page 3 of 12


REPORT INDEX


1     EQUIPMENT (TEST ITEM) DESCRIPTION                                                 5

1.1   Reference Documents                                                               6
1.2   Radiation Sources                                                                 7

2     RESULT SUMMARY                                                                    8

3     RF-EXPOSURE CLASSIFICATIONS                                                       9

4     ASSESSMENT                                                                       10

4.1   SAR Exemption Assessment –FCC KDB447498 / RSS-102                                10




                          Test Report No.: G0M-1508-4977-TFC093PE-V02
                                        Eurofins Product Service GmbH
                          Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                              Page 4 of 12


1    Equipment (Test item) Description

Description                       Laser Distance Meter
Model                             Leica DISTO Sigma3
Additional Model(s)               LD 250 BT
Brand Name(s)                     Leica DISTO
Serial number                     None
Hardware version                  V04
Software / Firmware version       0309
FCC-ID                            RFF-LD1BT
IC                                3177A-LD1BT
Equipment type                    End product




                       Test Report No.: G0M-1508-4977-TFC093PE-V02
                                      Eurofins Product Service GmbH
                        Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                            Page 5 of 12


1.1    Reference Documents


      Document type               Document No.                           Issued by               Date

  FCC 15.247 test report   G0M-1508-4977-TFC247BL-V02         Eurofins Product Service GmbH    2015-11-10




                           Test Report No.: G0M-1508-4977-TFC093PE-V02
                                         Eurofins Product Service GmbH
                           Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                              Page 6 of 12


1.2     Radiation Sources


      Mode #                                             Description

                Frequency range [MHz]                                           2402 – 2480
                Channels                                                            40
 Bluetooth LE   Modulations                                                       GFSK
                Maximum conducted power [dBm]                                      -1.59
                Maximum transmission duty cycle [%]                                100




                        Test Report No.: G0M-1508-4977-TFC093PE-V02
                                          Eurofins Product Service GmbH
                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                              Page 7 of 12


  2    Result Summary


                           FCC 47 CFR Part 2.1093, KDB447498, IC RSS-102

 Product Specific
                                             Requirement                          Result    Remarks
 Standard Section
   47 CFR 2.1093
                    SAR evaluation exemption : Bluetooth LE                       PASS
    KDB447498

   RSS-102 2.5.1    SAR evaluation exemption : Bluetooth LE                       PASS

Remarks:




                             Test Report No.: G0M-1508-4977-TFC093PE-V02
                                            Eurofins Product Service GmbH
                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                           Page 8 of 12


3   RF-Exposure Classifications

                                             Device Types
                      A fixed device is defined as a device physically secured at one fixed location
Fixed
                      and cannot be easily re-located.
                      A mobile device is defined as a transmitting device designed to be used in other
                      than fixed locations and to generally be used in such a way that a separation
Mobile                distance of at least 20 centimeters is normally maintained between the
                      transmitter's radiating structure(s) and the body of the user or nearby persons.
                      (47 CFR 2.1091)
                      A portable device is defined as a transmitting device designed to be used so
Portable              that the radiating structure(s) of the device is/are within 20 centimeters of the
                      body of the user. (47 CFR 2.1093)


                                        Exposure Categories
                      Limits apply in situations in which persons are exposed as a consequence of
                      their employment provided those persons are fully aware of the potential for
Occupational /        exposure and can exercise control over their exposure. Limits for
Controlled            occupational/controlled exposure also apply in situations when an individual is
                      transient through a location where occupational/controlled limits apply provided
                      he or she is made aware of the potential for exposure.
                     Exposures apply in situations in which the general public may be exposed, or in
General population / which persons that are exposed as a consequence of their employment may
uncontrolled         not be fully aware of the potential for exposure or cannot exercise control over
                     their exposure.




                         Test Report No.: G0M-1508-4977-TFC093PE-V02
                                        Eurofins Product Service GmbH
                          Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                          Page 9 of 12


  4         Assessment

  4.1        SAR Exemption Assessment –FCC KDB447498 / RSS-102


Low Power Exclusion acc. to FCC KDB447498                                                         Verdict: PASS

             Assessment according                                        Reference Method
                 to reference                           KDB447498 & 2.1093 / RSS-102 & Safety Code 6
                   Device type                                                 portable
               Exposure category                                         General population
                                                 FCC/IC SAR Limits
                                                   Occupational SAR values            General public SAR values
                      Region
                                                            [W/kg]                             [W/kg]
                   Whole-body
          SAR averaging mass = entire body
                                                               0.4                              0.08

                   Partial-body
             SAR averaging mass = 1g
                                                               8.0                               1.6

           Hands, Wrists, Feet and Ankles
            SAR averaging mass = 10g
                                                                20                               4

                                              FCC SAR test exclusion
Excerpt from KDB 447498:

Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body
and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or
numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed
below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum
conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the
minimum test separation distance required for the exposure conditions.

The minimum test separation distance is determined by the smallest distance from the antenna and
radiating structures or outer surface of the device, according to the host form factor, exposure conditions
and platform requirements, to any part of the body or extremity of a user or bystander

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:


                                                                        √                 {

            f [GHz] is the RF channel transmit frequency in GHz
            Power and distance are rounded to the nearest mW and mm before calculation
            The result is rounded to one decimal place for comparision

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm is applied to determine SAR test exclusion.


                                  Test Report No.: G0M-1508-4977-TFC093PE-V02
                                                Eurofins Product Service GmbH
                                  Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                  Page 10 of 12


                                    IC SAR evaluation exemptions
Excerpt from RSS-102 Issue 5:

SAR evaluation is required if the separation distance between the user and the radiating element of the
device is less than or equal to 20 cm, except when the device operates at a power level below the
following threshold limits:




                                         Assessment procedure
For the radiation source included into the device the output power is taken from a corresponding RF test
report. If needed the output power is converted to source based, time-averaged output power. Finally the
output power is compared to the FCC and IC low power SAR evaluation exemption level.




                            Test Report No.: G0M-1508-4977-TFC093PE-V02
                                          Eurofins Product Service GmbH
                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                         Page 11 of 12


                                             Assessment results
Transmission mode
Operating mode frequency range [MHz]                                         2402 – 2480
Assessment frequency [MHz]                                                        2480
Transmission duty cycle [%]                                                       100
Peak conducted power [dBm]                                                        -1.59
Minimum separation distance [mm]                                                  5.0
Source-based, time averaged power
Duty cycle correction [dB]                                                        0.0
Averaged conducted power [dBm]                                                    -1.59
Averaged conducted power [mW]                                                     0.69
Averaged radiated power
Antenna gain [dBi]                                                                -0.5
Averaged radiated power [dBm e.i.r.p.]                                            -2.09
Averaged radiated power [mW e.i.r.p.]                                             0.62
SAR evaluation exemption power levels

FCC SAR test exclusion condition                                         √                   → PASS

IC SAR test exclusion condition                                                           → PASS
Verdict
            The source-based, time-averaged output power of the EUT fulfills the SAR test exclusion
                         requirements according to FCC KDB447498 and IC RSS-102
Comments: