Test report

FCC ID: RDR-BOX1

Test Report

Download: PDF
FCCID_3589050

                             Global United Technology Services Co., Ltd.

                                                                                  Report No.: GTS201707000208F02



                                       FCC REPORT
    Applicant:                        Dongguan Hele Electronics Co., Ltd.

    Address of Applicant:             Dalingya Industrial Zone, Daojiao Town, Dongguan City,
                                      Guangdong, China
    Manufacturer:                     Dongguan Hele Electronics Co., Ltd.

    Address of                        Dalingya Industrial Zone, Daojiao Town, Dongguan City,
    Manufacturer:                     Guangdong, China
    Equipment Under Test (EUT)

      Product Name:                   Bluetooth Speaker
      Model No.:                      BOX1
    FCC ID:                           RDR-BOX1
    Applicable standards:             FCC CFR Title 47 Part 15 Subpart C Section 15.249:2017

    Date of sample receipt:           June 30, 2017

    Date of Test:                     July 03-06, 2017

    Date of report issued:            July 07, 2017

    Test Result :                     PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




      Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.


                                                                               Report No.: GTS201707000208F02

2      Version

           Version No.                                  Date                            Description
                 00                                July 07, 2017                          Original




Prepared By:                                                       Date:                 July 07, 2017

                                     Project Engineer


Check By:                                                          Date:                 July 07, 2017

                                          Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 2 of 24


                                                                                                             Report No.: GTS201707000208F02

3         Contents
                                                                                                                                                           Page
1     COVER PAGE ............................................................................................................................................ 1

2      VERSION .................................................................................................................................................. 2

3      CONTENTS .............................................................................................................................................. 3

4      TEST SUMMARY ..................................................................................................................................... 4
    4.1        MEASUREMENT UNCERTAINTY ............................................................................................................ 4
5      GENERAL INFORMATION ...................................................................................................................... 5
    5.1        GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.2        TEST MODE ........................................................................................................................................ 7
    5.3        DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7
    5.4        TEST FACILITY.................................................................................................................................... 7
    5.5        TEST LOCATION ................................................................................................................................. 7
    5.6        OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 7
6      TEST INSTRUMENTS LIST ..................................................................................................................... 8

7      TEST RESULTS AND MEASUREMENT DATA...................................................................................... 9
    7.1     ANTENNA REQUIREMENT ..................................................................................................................... 9
    7.2     CONDUCTED EMISSIONS ................................................................................................................... 10
    7.3     RADIATED EMISSION METHOD ........................................................................................................... 13
       7.3.1 Field Strength of The Fundamental Signal ................................................................................ 15
       7.3.2 Spurious emissions .................................................................................................................... 16
       7.3.3 Bandedge emissions.................................................................................................................. 20
    7.4     20DB OCCUPY BANDWIDTH .............................................................................................................. 21
8      TEST SETUP PHOTO ............................................................................................................................ 23

9      EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 24




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                     Page 3 of 24


                                                                               Report No.: GTS201707000208F02

4      Test Summary
                 Test Item                             Section in CFR 47                     Result
          Antenna requirement                                 15.203                          Pass
    AC Power Line Conducted Emission                          15.207                          Pass
Field strength of the fundamental signal                    15.249 (a)                        Pass
           Spurious emissions                         15.249 (a) (d)/15.209                   Pass
                Band edge                               15.249 (d)/15.205                     Pass
        20dB Occupied Bandwidth                             15.215 (c)                        Pass
Pass: The EUT complies with the essential requirements in the standard.
Remark: Test according to ANSI C63.10: 2013 and ANSI C63.4: 2014.


4.1 Measurement Uncertainty
            Test Item                      Frequency Range                Measurement Uncertainty       Notes
        Radiated Emission                     9kHz ~ 30MHz                         4.34dB               (1)
        Radiated Emission                  30MHz ~ 1000MHz                         4.24dB               (1)
        Radiated Emission                   1GHz ~ 26.5GHz                         4.68dB               (1)
    AC Power Line Conducted
                                            0.15MHz ~ 30MHz                        3.45dB               (1)
          Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 4 of 24


                                                                               Report No.: GTS201707000208F02

5      General Information
5.1 General Description of EUT
      Product Name:                      Bluetooth Speaker
      Model No.:                         BOX1
      Operation Frequency:               2402MHz~2480MHz
      Channel numbers:                   40
      Channel separation:                2MHz
      Modulation type:                   GFSK
      Antenna Type:                      PCB antenna
      Antenna gain:                      0dBi
      Power supply:                      Battery: DC 3.7V, 3.52Wh, 950mAh




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 5 of 24


                                                                                 Report No.: GTS201707000208F02


Operation Frequency each of channel
 Channel       Frequency        Channel       Frequency       Channel          Frequency   Channel        Frequency
     1          2402MHz            11         2422MHz            21            2442MHz       31           2462MHz
     2          2404MHz            12         2424MHz            22            2444MHz       32           2464MHz
   .
   ..…



                   .
                   ..…



                                 .
                                 ..…



                                                 .
                                                 ..…



                                                                .
                                                                ..…



                                                                                 .
                                                                                 ..…



                                                                                            .
                                                                                            ..…



                                                                                                            .
                                                                                                            ..…
     9          2418MHz            19         2438MHz            29            2458MHz       39           2478MHz
    10          2420MHz            20         2440MHz            30            2460MHz       40           2480MHz
Note:
In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
middle frequency, and the highest frequency of channel were selected to perform the test, and the selected
channel see below:
         Channel                        Frequency
   The lowest channel                   2402MHz
   The middle channel                   2440MHz
  The Highest channel                   2480MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 6 of 24


                                                                                Report No.: GTS201707000208F02


5.2 Test mode
       Transmitting mode                    Keep the EUT in continuously transmitting mode
       Remark: During the test, the dutycycle >98%, the test voltage was tuned from 85% to 115% of the
       nominal rated supply voltage, and found that the worst case was under the nominal rated supply
       condition. So the report just shows that condition’s data.


Per-test mode.
We have verified the construction and function in typical operation, The EUT was placed on three different
polar directions; i.e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
            Axis                            X                             Y                         Z
  Field Strength(dBuV/m)                 92.51                          93.01                    91.21
5.3 Description of Support Units
None

5.4 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ● FCC —Registration No.: 600491
       Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in files. Registration 600491, June 22, 2016.
       ● Industry Canada (IC) —Registration No.: 9079A-2
       The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
       Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
       No.: 9079A-2, August 15, 2016
5.5 Test Location
       All tests were performed at:
       Global United Technology Services Co., Ltd.
       Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road,
       Baoan District, Shenzhen, Guangdong, China 518102
       Tel: 0755-27798480
       Fax: 0755-27798960
5.6 Other Information Requested by the Customer
       None.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 7 of 24


                                                                                Report No.: GTS201707000208F02

6          Test Instruments list
Radiated Emission:
                                                                               Inventory      Cal.Date        Cal.Due date
Item         Test Equipment         Manufacturer           Model No.
                                                                                  No.        (mm-dd-yy)       (mm-dd-yy)
             3m Semi- Anechoic
 1                                ZhongYu Electron    9.2(L)*6.2(W)* 6.4(H)    GTS250       July 03 2015   July 02 2020
                 Chamber
 2            Control Room        ZhongYu Electron 6.2(L)*2.5(W)* 2.4(H)       GTS251           N/A            N/A
 3          Spectrum Analyzer         Agilent             E4440A               GTS533       June 28 2017   June 27 2018
 4          EMI Test Receiver     Rohde & Schwarz         ESU26                GTS203       June 28 2017   June 27 2018
                                  SCHWARZBECK
 5         BiConiLog Antenna                            VULB9163               GTS214       June 28 2017   June 27 2018
                                 MESS-ELEKTRONIK
         Double -ridged waveguide SCHWARZBECK
 6                                                      9120D-829              GTS208       June 28 2017   June 27 2018
                    horn         MESS-ELEKTRONIK
 7            Horn Antenna        ETS-LINDGREN             3160                GTS217       June 28 2017   June 27 2018
 8          EMI Test Software         AUDIX                  E3                 N/A             N/A            N/A
 9            Coaxial Cable             GTS                   N/A              GTS213       June 28 2017   June 27 2018
10           Coaxial Cable              GTS                  N/A               GTS211       June 28 2017   June 27 2018
11            Coaxial cable             GTS                  N/A               GTS210       June 28 2017   June 27 2018
12           Coaxial Cable              GTS                  N/A               GTS212       June 28 2017   June 27 2018
13       Amplifier(100kHz-3GHz)         HP                  8347A              GTS204       June 28 2017   June 27 2018
14       Amplifier(2GHz-20GHz)          HP                  8349B              GTS206       June 28 2017   June 27 2018
                                                         AFS33-18002
15         Amplifier (18-26GHz)   Rohde & Schwarz                              GTS218       June 28 2017   June 27 2018
                                                         650-30-8P-44
16             Band filter           Amindeon               82346              GTS219       June 28 2017   June 27 2018
17            Power Meter             Anritsu              ML2495A             GTS540       June 28 2017   June 27 2018
18            Power Sensor            Anritsu              MA2411B             GTS541       June 28 2017   June 27 2018


Conducted Emission:
                                                                                Inventory      Cal.Date       Cal.Due date
 Item          Test Equipment       Manufacturer            Model No.
                                                                                   No.        (mm-dd-yy)      (mm-dd-yy)
     1         Shielding Room      ZhongYu Electron    7.3(L)x3.1(W)x2.9(H)     GTS252       May.16 2014 May.15 2019
     2        EMI Test Receiver         R&S                   ESCI 7            GTS552       June 28 2017 June 27 2018
     3         Coaxial Switch      ANRITSU CORP               MP59B             GTS225       June 28 2017 June 27 2018
               Artificial Mains    SCHWARZBECK
     4                                                      NSLK8127            GTS226       June 28 2017 June 27 2018
                   Network              MESS
     5          Coaxial Cable           GTS                    N/A              GTS227           N/A          N/A
     6        EMI Test Software        AUDIX                   E3                N/A             N/A          N/A
     7          Thermo meter             KTJ                  TA328             GTS233       June 29 2017 June 28 2018


General used equipment:
                                                                               Inventory      Cal.Date        Cal.Due date
Item         Test Equipment         Manufacturer            Model No.
                                                                                  No.        (mm-dd-yy)       (mm-dd-yy)
 1              Barometer           ChangChun                DYM3              GTS257       June 28 2017      June 27 2018




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 8 of 24


                                                                                Report No.: GTS201707000208F02

7      Test results and Measurement Data
7.1 Antenna requirement
      Standard requirement:            FCC Part15 C Section 15.203
      15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
       party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a
       unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be
       replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
      EUT Antenna:

        The antenna is PCB antenna, the best case gain of the antenna is 0dBi




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 9 of 24


                                                                               Report No.: GTS201707000208F02


7.2 Conducted Emissions
      Test Requirement:                FCC Part15 C Section 15.207
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            150KHz to 30MHz
      Class / Severity:                Class B         Class B
      Receiver setup:                  RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                         Limit (dBuV)
                                          Frequency range (MHz)
                                                                          Quasi-peak              Average
                                                 0.15-0.5                   66 to 56*             56 to 46*
                                                  0.5-5                         56                   46
                                                   5-30                         60                   50
                                       * Decreases with the logarithm of the frequency.
      Test setup:




      Test procedure:                  1. The E.U.T and simulators are connected to the main power through a
                                          line impedance stabilization network (L.I.S.N.). This provides a
                                          50ohm/50uH coupling impedance for the measuring equipment.
                                       2. The peripheral devices are also connected to the main power through a
                                          LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                          termination. (Please refer to the block diagram of the test setup and
                                          photographs).
                                       3. Both sides of A.C. line are checked for maximum conducted
                                          interference. In order to find the maximum emission, the relative
                                          positions of equipment and all of the interface cables must be changed
                                          according to ANSI C63.10:2013 on conducted measurement.
      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Measurement data:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 10 of 24


                                                                               Report No.: GTS201707000208F02
Line:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 11 of 24


                                                                               Report No.: GTS201707000208F02


Neutral:




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak
     emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss
4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet
   both limits and measurement with the average detector receiver is unnecessary.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 12 of 24


                                                                                 Report No.: GTS201707000208F02


7.3 Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            30MHz to 25GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                    Frequency          Detector           RBW        VBW          Remark
                                           30MHz-         Quasi-peak       120KHz        300KHz   Quasi-peak Value
                                            1GHz
                                                              Peak             1MHz      3MHz        Peak Value
                                        Above 1GHz
                                                              Peak             1MHz       10Hz     Average Value
      Limit:                                    Frequency               Limit (dBuV/m @3m)             Remark
      (Field strength of the              2400MHz-2483.5MHz                      94.00             Average Value
      fundamental signal)
      Limit:                                    Frequency             Limit (dBuV/m @3m)            Remark
      (Spurious Emissions)                   30MHz-88MHz                      40.00            Quasi-peak Value
                                             88MHz-216MHz                     43.50            Quasi-peak Value
                                            216MHz-960MHz                     46.00            Quasi-peak Value
                                              960MHz-1GHz                     54.00            Quasi-peak Value
                                                                              54.00              Average Value
                                              Above 1GHz
                                                                              74.00               Peak Value
      Limit:                           Emissions radiated outside of the specified frequency bands, except for
      (band edge)                      harmonics, shall be attenuated by at least 50 dB below the level of the
                                       fundamental or to the general radiated emission limits in Section 15.209,
                                       whichever is the lesser attenuation.
      Test setup:                      Below 1GHz




                                       Above 1GHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 13 of 24


                                                                               Report No.: GTS201707000208F02




      Test Procedure:                  1. The EUT was placed on the top of a rotating table (0.8m for below
                                          1GHz and 1.5 meters for above 1GHz) above the ground at a 3 meter
                                          camber. The table was rotated 360 degrees to determine the position of
                                          the highest radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                          antenna, which was mounted on the top of a variable-height antenna
                                          tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                          ground to determine the maximum value of the field strength. Both
                                          horizontal and vertical polarizations of the antenna are set to make the
                                          measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                          and then the antenna was tuned to heights from 1 meter to 4 meters
                                          and the rota table was turned from 0 degrees to 360 degrees to find the
                                          maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                          Specified Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                          limit specified, then testing could be stopped and the peak values of the
                                          EUT would be reported. Otherwise the emissions that did not have
                                          10dB margin would be re-tested one by one using peak, quasi-peak or
                                          average method as specified and then reported in a data sheet.
      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Measurement data:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 14 of 24


                                                                                Report No.: GTS201707000208F02

7.3.1   Field Strength of The Fundamental Signal
Peak value:
                 Read         Antenna       Cable       Preamp                                   Over
Frequency                                                              Level      Limit Line
                 Level         Factor       Loss         Factor                                  Limit      polarization
  (MHz)                                                              (dBuV/m)     (dBuV/m)
                (dBuV)         (dB/m)        (dB)         (dB)                                   (dB)
  2402.00        94.05         27.58         5.39        34.01         93.01       114.00       -20.99        Vertical
  2402.00        87.76         27.58         5.39        34.01         86.72       114.00       -27.28      Horizontal
  2440.00        94.01         27.48         5.43        33.96         92.96       114.00       -21.04        Vertical
  2440.00        87.88         27.48         5.43        33.96         86.83       114.00       -27.17      Horizontal
  2480.00        92.32         27.52         5.47        33.92         91.39       114.00       -22.61        Vertical
  2480.00        86.37         27.52         5.47        33.92         85.44       114.00       -28.56      Horizontal
Average value:
                 Read         Antenna       Cable       Preamp                                   Over
Frequency                                                              Level      Limit Line
                 Level         Factor       Loss         Factor                                  Limit      polarization
  (MHz)                                                              (dBuV/m)     (dBuV/m)
                (dBuV)         (dB/m)        (dB)         (dB)                                   (dB)
  2402.00        83.67         27.58         5.39        34.01         82.63        94.00       -11.37        Vertical
  2402.00        78.32         27.58         5.39        34.01         77.28        94.00       -16.72      Horizontal
  2440.00        84.32         27.48         5.43        33.96         83.27        94.00       -10.73        Vertical
  2440.00        77.37         27.48         5.43        33.96         76.32        94.00       -17.68      Horizontal
  2480.00        83.48         27.52         5.47        33.92         82.55        94.00       -11.45        Vertical
  2480.00        77.73         27.52         5.47        33.92         76.80        94.00       -17.20      Horizontal


    NOTE: RBW 3MHz VBW 3MHz Peak detector is for PK value ,RMS detector is for AV value




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 15 of 24


                                                                                Report No.: GTS201707000208F02

7.3.2   Spurious emissions
    Below 1GHz
                 Read         Antenna       Cable       Preamp                                   Over
Frequency                                                              Level      Limit Line
                 Level         Factor       Loss         Factor                                  Limit      polarization
  (MHz)                                                              (dBuV/m)     (dBuV/m)
                (dBuV)         (dB/m)        (dB)         (dB)                                   (dB)
    102.72       34.16         12.10         1.22        29.79         17.69        43.50       -25.81        Vertical
    155.91       36.23          7.85         1.60        29.58         16.10        43.50       -27.40        Vertical
    181.92       37.82          8.80         1.75        29.48         18.89        43.50       -24.61        Vertical
    257.42       31.52         12.14         2.16        29.86         15.96        46.00       -30.04        Vertical
    300.37       32.97         13.50         2.36        30.20         18.63        46.00       -27.37        Vertical
    601.43       27.18         19.30         3.73        29.39         20.82        46.00       -25.18        Vertical
    75.45        32.67          7.35         0.99        29.94         11.07        40.00       -28.93      Horizontal
    95.76        31.88         11.35         1.16        29.82         14.57        43.50       -28.93      Horizontal
    143.83       32.03          7.37         1.53        29.62         11.31        43.50       -32.19      Horizontal
    167.82       35.02          8.33         1.67        29.53         15.49        43.50       -28.01      Horizontal
    216.02       30.34         10.78         1.93        29.52         13.53        46.00       -32.47      Horizontal
    414.72       27.12         15.80         2.92        29.59         16.25        46.00       -29.75      Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 16 of 24


                                                                               Report No.: GTS201707000208F02

     Above 1GHz
Test channel:                                                Lowest channel

Peak value:
                 Read        Antenna        Cable      Preamp                                    Over
Frequency                                                            Level      Limit Line
                 Level        Factor        Loss        Factor                                   Limit   polarization
  (MHz)                                                            (dBuV/m)     (dBuV/m)
                (dBuV)        (dB/m)        (dB)         (dB)                                    (dB)
    4804.00      37.07         31.78        8.60        32.09         45.36       74.00         -28.64        Vertical
    7206.00      31.67         36.15        11.65       32.00         47.47       74.00         -26.53        Vertical
    9608.00      31.33         37.95        14.14       31.62         51.80       74.00         -22.20        Vertical
 12010.00           *                                                             74.00                       Vertical
 14412.00           *                                                             74.00                       Vertical
    4804.00      41.30         31.78        8.60        32.09         49.59       74.00         -24.41       Horizontal
    7206.00      33.41         36.15        11.65       32.00         49.21       74.00         -24.79       Horizontal
    9608.00      30.73         37.95        14.14       31.62         51.20       74.00         -22.80       Horizontal
 12010.00           *                                                             74.00                      Horizontal
 14412.00       *                                                                 74.00                      Horizontal
Average value:
              Read           Antenna       Cable       Preamp                                    Over
Frequency                                                            Level      Limit Line
              Level           Factor       Loss        Factor                                    Limit   polarization
   (MHz)                                                           (dBuV/m)     (dBuV/m)
             (dBuV)           (dB/m)       (dB)          (dB)                                    (dB)
  4804.00     25.93            31.78       8.60         32.09        34.22        54.00         -19.78        Vertical
    7206.00      20.39         36.15        11.65       32.00        36.19        54.00         -17.81        Vertical
    9608.00      19.48         37.95        14.14       31.62        39.95        54.00         -14.05        Vertical
 12010.00          *                                                              54.00                       Vertical
 14412.00          *                                                              54.00                       Vertical
    4804.00      30.13         31.78        8.60        32.09        38.42        54.00         -15.58       Horizontal
    7206.00      22.54         36.15        11.65       32.00        38.34        54.00         -15.66       Horizontal
    9608.00      19.19         37.95        14.14       31.62        39.66        54.00         -14.34       Horizontal
 12010.00          *                                                              54.00                      Horizontal
 14412.00         *                                                             54.00                        Horizontal
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 17 of 24


                                                                               Report No.: GTS201707000208F02

Test channel:                                                Middle
Peak value:
                 Read        Antenna       Cable       Preamp                                    Over
Frequency                                                            Level      Limit Line
                 Level        Factor       Loss        Factor                                    Limit   polarization
  (MHz)                                                            (dBuV/m)     (dBuV/m)
                (dBuV)        (dB/m)       (dB)          (dB)                                    (dB)
  4880.00        36.97         31.85       8.67         32.12         45.37       74.00         -28.63        Vertical
  7320.00        36.98         31.85        8.67        32.12         45.38       74.00         -28.62        Vertical
  9760.00        31.61         36.37        11.72       31.89         47.81       74.00         -26.19        Vertical
 12200.00        31.27         38.35        14.25       31.62         52.25       74.00         -21.75        Vertical
 14640.00          *                                                              74.00                       Vertical
  4880.00          *                                                              74.00                      Horizontal
  7320.00        41.19         31.85        8.67        32.12         49.59       74.00         -24.41       Horizontal
  9760.00        33.34         36.37        11.72       31.89         49.54       74.00         -24.46       Horizontal
 12200.00        30.67         38.35        14.25       31.62         51.65       74.00         -22.35       Horizontal
 14640.00       *                                                                 74.00                      Horizontal
Average value:
              Read           Antenna       Cable       Preamp                                    Over
Frequency                                                            Level      Limit Line
              Level           Factor       Loss        Factor                                    Limit   polarization
   (MHz)                                                           (dBuV/m)     (dBuV/m)
             (dBuV)           (dB/m)       (dB)          (dB)                                    (dB)
  4880.00     25.86            31.85       8.67         32.12         34.26       54.00         -19.74        Vertical
  7320.00        20.34         36.37        11.72       31.89         36.54       54.00         -17.46        Vertical
  9760.00        19.44         38.35        14.25       31.62         40.42       54.00         -13.58        Vertical
 12200.00          *                                                              54.00                       Vertical
 14640.00          *                                                              54.00                       Vertical
  4880.00        30.06         31.85        8.67        32.12         38.46       54.00         -15.54       Horizontal
  7320.00        22.50         36.37        11.72       31.89         38.70       54.00         -15.30       Horizontal
  9760.00        19.14         38.35        14.25       31.62         40.12       54.00         -13.88       Horizontal
 12200.00          *                                                              54.00                      Horizontal
 14640.00         *                                                             54.00                        Horizontal
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 18 of 24


                                                                                     Report No.: GTS201707000208F02

Test channel:                                                      Highest
Peak value:
                   Read         Antenna         Cable       Preamp                                     Over
Frequency                                                                  Level      Limit Line
                   Level         Factor         Loss        Factor                                     Limit   polarization
  (MHz)                                                                  (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)         (dB)          (dB)                                     (dB)
     4960.00       36.15          31.93         8.73         32.16         44.65         74.00        -29.35        Vertical
     7440.00       31.06          36.59         11.79        31.78         47.66         74.00        -26.34        Vertical
     9920.00       30.79          38.81         14.38        31.88         52.10         74.00        -21.90        Vertical
 12400.00             *                                                                  74.00                      Vertical
 14880.00             *                                                                  74.00                      Vertical
     4960.00       40.20          31.93         8.73         32.16         48.70         74.00        -25.30       Horizontal
     7440.00       32.72          36.59         11.79        31.78         49.32         74.00        -24.68       Horizontal
     9920.00       30.10          38.81         14.38        31.88         51.41         74.00        -22.59       Horizontal
 12400.00             *                                                                  74.00                     Horizontal
 14880.00       *                                                                        74.00                     Horizontal
Average value:
              Read              Antenna         Cable       Preamp                                     Over
Frequency                                                                  Level      Limit Line
              Level              Factor         Loss        Factor                                     Limit   polarization
   (MHz)                                                                 (dBuV/m)     (dBuV/m)
             (dBuV)              (dB/m)         (dB)          (dB)                                     (dB)
  4960.00     25.23               31.93         8.73         32.16         33.73         54.00        -20.27        Vertical
     7440.00       19.92          36.59         11.79        31.78         36.52         54.00        -17.48        Vertical
     9920.00       19.06          38.81         14.38        31.88         40.37         54.00        -13.63        Vertical
 12400.00             *                                                                  54.00                      Vertical
 14880.00             *                                                                  54.00                      Vertical
     4960.00       29.34          31.93         8.73         32.16         37.84         54.00        -16.16       Horizontal
     7440.00       22.02          36.59         11.79        31.78         38.62         54.00        -15.38       Horizontal
     9920.00       18.70          38.81         14.38        31.88         40.01         54.00        -13.99       Horizontal
 12400.00             *                                                                  54.00                     Horizontal
 14880.00             *                                                                  54.00                     Horizontal
Remark:
1.    Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.    “*”, means this data is the too weak instrument of signal is unable to test.
3.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 19 of 24


                                                                               Report No.: GTS201707000208F02

7.3.3   Bandedge emissions
        All of the restriction bands were tested, and only the data of worst case was exhibited.
Test channel:                                                   Lowest channel
Peak value:
                 Read        Antenna       Cable       Preamp                                      Over
Frequency                                                             Level       Limit Line
                 Level        Factor       Loss         Factor                                     Limit       Polarization
  (MHz)                                                             (dBuV/m)      (dBuV/m)
                (dBuV)        (dB/m)        (dB)         (dB)                                      (dB)
 2390.00         45.12         27.59        5.38         30.18        47.91         74.00         -26.09       Horizontal
 2400.00         48.22         27.58        5.39         30.18        51.01         74.00         -22.99       Horizontal
 2390.00      45.88            27.59        5.38         30.18        48.67         74.00         -25.33         Vertical
 2400.00      44.50            27.58        5.39         30.18        47.29         74.00         -26.71         Vertical
Average value:
              Read           Antenna       Cable       Preamp                                      Over
Frequency                                                             Level       Limit Line
              Level           Factor       Loss         Factor                                     Limit       Polarization
  (MHz)                                                             (dBuV/m)      (dBuV/m)
             (dBuV)           (dB/m)        (dB)         (dB)                                      (dB)
 2390.00      35.16            27.59       5.38         30.18         37.95         54.00         -16.05       Horizontal
 2400.00      36.53            27.58       5.39         30.18         39.32         54.00         -14.68       Horizontal
 2390.00      35.26            27.59       5.38         30.18         38.05         54.00         -15.95        Vertical
 2400.00      38.39            27.58       5.39         30.18         41.18         54.00         -12.82        Vertical

Test channel:                                                   Highest channel
Peak value:
                 Read        Antenna       Cable       Preamp                                      Over
Frequency                                                             Level       Limit Line
                 Level        Factor       Loss         Factor                                     Limit       Polarization
  (MHz)                                                             (dBuV/m)      (dBuV/m)
                (dBuV)        (dB/m)        (dB)         (dB)                                      (dB)
 2483.50         47.49         27.53        5.47         29.93        50.56         74.00         -23.44       Horizontal
 2500.00         46.23         27.55        5.49         29.93        49.34         74.00         -24.66       Horizontal
 2483.50         48.70         27.53        5.47         29.93        51.77         74.00         -22.23         Vertical
 2500.00         47.44         27.55        5.49         29.93        50.55         74.00         -23.45         Vertical
Average value:
              Read           Antenna       Cable       Preamp
Frequency                                                            Level        Limit Line      Over
              Level           Factor       Loss        Factor                                                  Polarization
  (MHz)                                                            (dBuV/m)       (dBuV/m)      Limit (dB)
             (dBuV)           (dB/m)        (dB)        (dB)
 2483.50         38.01        27.53         5.47        29.93        41.08          54.00         -12.92       Horizontal
 2500.00         35.70        27.55         5.49        29.93        38.81          54.00         -15.19       Horizontal
 2483.50         39.41        27.53         5.47        29.93        42.48          54.00         -11.52         Vertical
 2500.00     35.80       27.55       5.49      29.93       38.91       54.00       -15.09                        Vertical
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 20 of 24


                                                                               Report No.: GTS201707000208F02

7.4 20dB Occupy Bandwidth
      Test Requirement:                FCC Part15 C Section 15.249/15.215
      Test Method:                     ANSI C63.10:2013
      Limit:                           Operation Frequency range 2400MHz~2483.5MHz
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Measurement Data
          Test channel                        20dB bandwidth(MHz)                           Result
               Lowest                                 1.197                                  Pass
               Middle                                 1.198                                  Pass
               Highest                                1.197                                  Pass


Test plot as follows:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 21 of 24


                                                                               Report No.: GTS201707000208F02




                                                  Lowest channel




                                                   Middle channel




                                                  Highest channel




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 22 of 24


                                                                               Report No.: GTS201707000208F02

8      Test Setup Photo
       Radiated Emission




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 23 of 24


                                                                               Report No.: GTS201707000208F02


       Conducted Emission




9      EUT Constructional Details
        Reference to the test report No. : GTS201707000208F01




                                                  ------End------




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 24 of 24



Document Created: 2017-09-25 17:15:17
Document Modified: 2017-09-25 17:15:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC