RF Exposure

FCC ID: RD7-SENSOR4X

RF Exposure Info

Download: PDF
FCCID_3241791

    Company: NetScout Systems Inc.

    Test of: SENSOR4 Product Family
To: FCC CFR 47 Part 15 Subpart E 15.407

  Report No.: NTCT77-U4 MPE Rev A




            MPE REPORT


                MPE TEST REPORT
                                FROM




Test of: NetScout Systems Inc. SENSOR4 Product Family
                           to
      To: FCC CFR 47 Part 15 Subpart E 15.407
    Test Report Serial No.: NTCT77-U4 MPE Rev A
               This report supersedes: None

                    Applicant:        NetScout Systems Inc.
                                      178 E. Tasman Drive
                                      San Jose, CA. 95134
                                      USA
         Product Function:            Wireless LAN Client
                  Issue Date:         15th November 2016



     This Test Report is Issued Under the Authority of:

        MiCOM Labs, Inc.
        575 Boulder Court
        Pleasanton California 94566
        USA
        Phone: +1 (925) 462-0304
        Fax: +1 (925) 462-0306
        www.micomlabs.com

       MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


1. MAXIMUM PERMISSABLE EXPOSURE
Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm 2) = EIRP/(4*π*d2)
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)
Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is
1.0 mW/cm2

The calculations in the table below use the highest conducted power values together with the lowest
antenna gain specified for the EUT. These calculations represent worst case in terms of the exposure
levels.
                                               Peak                       Calculated
                         Ant    Numeric                                                        Minimum
                                             Output     Peak Output Power Density
  Freq. Band (MHz) Gain           Gain                                             2          Separation
                                              Power     Power (mW)       (mW/cm ) @
                        (dBi) (numeric)                                                     Distance (cm)
                                              (dBm)                          20cm
   2400.0 - 2483.5        2       1.58         24.14       259.66             0.08              20.00


    5150 – 5250        4.8       3.02        16.92          49.2              0.03              20.00
    5250 – 5350        4.8       3.02        23.14         206.1              0.12              20.00
    5470 - 5725        4.8       3.02        22.72         187.1              0.11              20.00
    5725 - 5850        4.8       3.02        22.37         172.6              0.12              20.00

Assessment for simultaneous operation:
                                              Peak                        Calculated
                       Ant     Numeric                                                       Minimum
                                             Output     Peak Output     Power Density
 Freq. Band (MHz)     Gain      Gain                                                        Separation
                                             Power      Power (mW)       (mW/cm2) @
                      (dBi)   (numeric)                                                    Distance (cm)
                                             (dBm)                          20cm
    5250 – 5350        4.8       3.02         23.14         206.1            0.12               20.00
  2400.0 - 2483.5       2        1.58         3.02         259.66             0.08              20.00

                                      EIRP TOTAL (mW/EIRP) : 625.47             0.2              20.00
Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if
calculations indicate the MPE distance to be less.

Specification
Maximum Permissible Exposure Limits



FCC §1.1310 Limit = 1mW / cm2 from 1.310 Table 1


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2017-12-20 03:38:09
Document Modified: 2017-12-20 03:38:09

© 2024 FCC.report