MPE

FCC ID: RAXWN7111A

RF Exposure Info

Download: PDF
FCCID_1469846

                                               Report No.: FR141904




            Appendix C. Maximum Permissible Exposure




FCC ID: RAXWN7111A                            Page No.   : C1 of C3


                                                                                                   Report No.: FR141904



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures that the
      public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure.
      In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a
      mobile device whereby a distance of 0.25 m normally can be maintained between the user and the
      device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                                       Averaging Time
       Frequency Range               Electric Field     Magnetic Field         Power Density (S)
                                                                                                        |E|²,|H|² or S
             (MHz)                Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                          (minutes)
             0.3-3.0                     614                 1.63                    (100)*                   6
             3.0-30                    1842 / f             4.89 / f                (900 / f)*                6
             30-300                     61.4                 0.163                     1.0                    6
            300-1500                                                                  F/300                   6
         1500-100,000                                                                     5                   6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                                       Averaging Time
       Frequency Range               Electric Field     Magnetic Field        Power Density (S)
                                                                                                        |E|²,|H|² or S
             (MHz)                Strength (E) (V/m)   Strength (H) (A/m)        (mW/ cm²)
                                                                                                          (minutes)
            0.3-1.34                    614                  1.63                    (100)*                  30
             1.34-30                    824/f                2.19/f                  (180/f)*                30
             30-300                     27.5                 0.073                     0.2                   30
            300-1500                                                                 F/1500                  30
         1500-100,000                                                                  1.0                   30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

      E (V/m) =
                     30  P  G                   Power Density:      Pd (W/m²) =
                                                                                    E2
                         d                                                          377
      E = Electric field (V/m)
      P = Peak RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to

      Pd =
             30  P  G
              377  d 2
      From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain
      of the used antenna, the RF power density can be obtained.

FCC ID: RAXWN7111A                                                                               Page No.   : C2 of C3


                                                                                     Report No.: FR141904


1.3. Calculated Result and Limit

      Antenna Type : PCB
      Max Conducted Power for IEEE 802.11b/g: 26.1 dBm
                                   Peak Output                  Power Density Limit of Power
      Antenna Gain Antenna Gain                  Peak Output
                                      Power                          (S)        Density (S)    Test Result
          (dBi)      (numeric)                   Power ( mW )
                                      (dBm)                       (mW/cm²)      (mW/cm²)
           0.83        1.2106        26.1000      407.3803        0.098164          1          Complies




FCC ID: RAXWN7111A                                                                 Page No.    : C3 of C3



Document Created: 2011-05-18 15:15:59
Document Modified: 2011-05-18 15:15:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC