MPE REPORT

FCC ID: RAXWG4005G

RF Exposure Info

Download: PDF
FCCID_652273

FCC ID. : RAXWG4005G                                                   Report No.: EME-060370
                                                                               Page 1 of 5




      Maximum Permissible Exposure (MPE)
              Evaluation Report

              Report No.     : EME-060250
              Model No.      : F5D7230-4, USR805463, USR015463,
                               USR5463, SMCWBR14-G2
              Issued Date    : Apr. 14, 2006




    Applicant     : Arcadyan Technology Corporation
                    4F, No. 9, Park Avenue II, Science-based Industrial Park,
                    Hsinchu 300, Taiwan

    Test By       : Intertek Testing Services Taiwan Ltd.
                    No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li,
                    Shiang-Shan District, Hsinchu City, Taiwan



   This test report consists of 5 pages in total. It may be duplicated completely
    for legal use with the allowance of the applicant. It shall not be reproduced
   except in full, without the written approval of Intertek Laboratory. The test
   result(s) in this report only applies to the tested sample(s).




     Project Engineer                               Reviewed By




      Jerry Liu                                        Kevin Chen


   FCC ID. : RAXWG4005G                                                                                         Report No.: EME-060370
                                                                                                                        Page 2 of 5


                                                        Table of Contents

Summary of Tests ............................................................................................................. 3

1. Introduction .................................................................................................................. 4

2. RF Exposure Limit ....................................................................................................... 4

3. RF Exposure calculations ............................................................................................. 5

4. Test results .................................................................................................................... 5


 FCC ID. : RAXWG4005G                                             Report No.: EME-060370
                                                                          Page 3 of 5


Summary of Tests

MPE Evaluation meet FCC OET No. 65: 1997/ IEEE C95.1-1999

                        Wireless G Router -Model: F5D7230-4
                              FCC ID: RAXWG4005G

      Test                          Reference                       Results
 MPE Evaluation    FCC Guidelines for Human Exposure IEEE C95.1    Complies


  FCC ID. : RAXWG4005G                                                     Report No.: EME-060370
                                                                                   Page 4 of 5

1. Introduction

The EUT operates in the 2.4GHz ISM band. Due to the EUT (include antenna) at its normal
operation distance is at least 20 cm from the human body, the EUT was defined as a Mobile
Device.


The reason to do the MPE Evaluation is to avoid the RF hazard to human body. The
maximum output power and gain of the antenna were used to calculate the limited Power
density (S) at 20cm distance away from the product. The limit for Maximum Permissible
Exposure (MPE) specified in FCC 1.1310 is followed.


2. RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
environmental impact of human exposure to radio-frequency (RF) radiation as specified in
1.1307(b).

                      Limits for Maximum Permissible Exposure (MPE)

   Frequency       Electric Field Magnetic Field
                                                     Power Density       Average Time
     Range           Strength         Strength
                                                       (mW/cm2)           (minutes)
     (MHz)            (V/m)            (A/m)
                   (A) Limits for Occupational / Control Exposures
     30-300             61.4             0.163               1.0                6
   300-1500               -                 -              F/300                6
 1500-100,000             -                 -                 5                 6
               (B) Limits for General Population / Uncontrolled Exposure
     30-300             27.5             0.073               0.2               30
   300-1500               -                 -              F/1500              30
 1500-100,000             -                 -                1.0               30

F= Frequency in MHz


  FCC ID. : RAXWG4005G                                                  Report No.: EME-060370
                                                                                Page 5 of 5

3. RF Exposure calculations

From §FCC 1.1310 table 1, the maximum permissible RF exposure for an
uncontrolled environment is 1mW/(cm2)
Power density (S) is calculated by the following formula:

S = (P * G)/4πR2

where, S = Power density (mW/cm2)
       P = Output power to antenna (mW)
       R = Distance between radiating structure and observation point (cm)
       G = Gain of antenna in numeric
       π = 3.1416

Example:
        Assume a mobile device operates at 2412MHz and its maximum output power is
50mW, and the maximum gain of antenna is 1 (numeric) /0dBi.

then the power density (S) = (50 * 1)/4*π*202 = 0.00995 (mW/cm2)

4. Test results


     Test Mode: 802.11b (DSSS Modulation) operating mode

                   Channel     Maximum Output power Power density Limit of
   Channel        Frequency   antenna gain to antenna            power density
                    (MHz)      (numeric)     (mW)     (mW/cm2)    (mW/cm2)
       1             2412         1.58        55.98    0.01765       1.0
       6             2437         1.58        56.86    0.01793       1.0
      11             2462         1.58        51.64    0.01628       1.0


     Test Mode: 802.11g (OFDM Modulation) operating mode

                   Channel     Maximum Output power Power density Limit of
   Channel        Frequency   antenna gain to antenna            power density
                                                              2
                    (MHz)      (numeric)     (mW)     (mW/cm )    (mW/cm2)
       1             2412         1.58        56.49    0.01781       1.0
       6             2437         1.58        58.48    0.01844       1.0
      11             2462         1.58        55.59    0.01753       1.0

The Notice in Installation Manual has been stated as below:
While installing and operating this transmitter, the radio frequency exposure limit of
1mW/(cm*cm) may be exceeded at distances close to the transmitter. therefore, the user must
maintain a minimum distance of 20 cm from the device at all time.



Document Created: 2006-04-27 16:25:25
Document Modified: 2006-04-27 16:25:25

© 2024 FCC.report